| Plan Review Stops For Permit 06051228 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2006-07-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-07-13 |
Time |
10:10 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-07-13 |
Time |
10:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2006-06-21 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-06-21 |
Time |
13:00 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-06-21 |
Time |
12:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2006-07-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-07-15 |
Time |
13:09 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-07-15 |
Time |
12:41 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-06-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-06-12 |
Time |
07:31 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-06-12 |
Time |
07:12 |
Sent To |
|
|
| Notes |
| 2006-06-12 00:00:00 | **** UNSAT **** | | | | | | PLANS ARE GENERALLY IN GOOD SHAPE, | | | HOWEVER PLEASE SEE THE FOLLOWING FOR | | | SOME CORRECTIONS. | | | | | | 1) NOTE: PLEASE SEE RISER MENTIONS, FOR | | | CONDUCTORS TO BE VERIFIED ON SITE. THIS | | | SHOULD BE DONE AT THIS TIME. | | | PLEASE VERIFY THE #2 SHOWN FOR THE | | | EQUIPMENT GROUNDING CONDUCTOR. THIS SIZE | | | SEEMS MUCH LARGER THAN WHAT WOULD BE | | | REQUIRED. IF SHOWN AS THIS SIZE, THIS IS | | | WHAT WILL BE REQUIRED. EXISTING | | | CONDITION TO BE VERIFIED. | | | 215.5,250.122,310.16.240.4 | | | | | | 2) NOTE: PLEASE SEE FBC | | | 13-415.1.ABC.1.1,.1.2,.1.3 FOR ALL AREAS | | | AND LOCATIONS WHICH REQUIRE CONTROLS. | | | PLEASE SEE BATH RM, SEE WHEN THE EGRESS | | | PATH IS FROM THE FRONT OF THE STORE A | | | DEVICE IS REQUIRED EITHER AUTOMATICALLY | | | OR MANUAL OVER RIDE BY OCCUPANT. PLEASE | | | SEE A MOTION SENSOR IS SHOWN AT THE REAR | | | OF THE STORE, HOWEVER PLEASE PROVIDE | | | SPECS FOR THIS DEVICE AS, THE DISTANCE | | | AND LOCATION MAY REQUIRE ONE ADDITIONAL | | | DEVICE EITHER BY MOTION OR TIME SWITCH. | | | PLEASE ALSO SEE DIPLAY/ ACCENT | | | LTS(TRACK) LTS SHALL CONTAIN CONTROLS | | | ALSO. | | | | | | 3) NOTE: PLEASE SEE PANEL "A" ON PLANS | | | INDICATES "RELOCATE". PLEASE SHOW NEW | | | LOCATION OR IS THIS THE NEW LOCATION.? | | | 215.5 | | | | | | ** PLEASE SEE ANY POSSIBLE COMMENTS FROM | | | OTHER TRADES WHICH MAY AFFECT ELECTRICAL | | | PLANS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2006-07-14 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-07-14 |
Time |
11:11 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-07-14 |
Time |
11:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2006-06-15 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-06-15 |
Time |
11:17 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-06-15 |
Time |
11:17 |
Sent To |
|
|
| Notes |
| 2006-06-15 00:00:00 | WHEN PLANS ARE RESUBMITTED FOR OTHER | | | REVIEW COMMENTS, PLEASE INDICATE MINIMUM | | | INTERIOR FINISH CLASSIFICATION FOR WALLS | | | AND CEILING THAT IS SPECIFIC TO THIS | | | PROJECT. NOTE ON PLANS IS GENERAL CODE | | | REQUIREMENT. | | | | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-09-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-23 |
Time |
14:26 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-23 |
Time |
14:26 |
Sent To |
M |
|
| Notes |
| 2006-09-23 00:00:00 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-07-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-07-07 |
Time |
16:55 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-07-07 |
Time |
16:55 |
Sent To |
|
|
| Notes |
| 2006-07-12 00:00:00 | TO "BOB"#3 | | 2006-07-07 00:00:00 | WAITING FOR "BOB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-06-21 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-06-21 |
Time |
13:00 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-05-31 |
Time |
15:09 |
Sent To |
|
|
| Notes |
| 2006-05-31 00:00:00 | TO "BOB"#9 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2006-09-29 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-09-29 |
Time |
14:16 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2006-09-29 |
Time |
14:16 |
Sent To |
|
|
| Notes |
| 2006-09-29 00:00:00 | REVISION TO MECHANICAL PLANS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2006-07-13 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-07-13 |
Time |
13:46 |
Rev Time |
0.15 |
| Received By |
tgordon |
Date |
2006-07-13 |
Time |
13:46 |
Sent To |
|
|
| Notes |
| 2006-07-13 00:00:00 | RE-STAMP MECH. PLAN. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2006-06-01 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-06-01 |
Time |
08:49 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2006-06-01 |
Time |
08:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2006-07-13 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-07-13 |
Time |
12:45 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-07-13 |
Time |
12:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-06-12 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-06-12 |
Time |
14:47 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-06-12 |
Time |
14:47 |
Sent To |
|
|
| Notes |
| 2006-06-12 00:00:00 | DENIED; | | | 1.PLANS MUST BE REVIEWED AND APPROVED BY | | | THE DEPARTMENT OF BUSINESS AND | | | PROFESSIONAL REGULATION, DEVISION OF | | | HOTELS AND RESTAURANTS. PLEASE SUBMIT | | | APPROVAL PAPER WORK. WEB SITE | | | WWW.MYFLORIDA.COM/DBPR/HR/FORMS/INDEX.SH | | | WW.MYFLORIDA.COM/DBPR/HR/FORMS/INDEX.SHT | | | W.MYFLORIDA.COM/DBPR/HR/FORMS/INDEX.SHTM | | | .MYFLORIDA.COM/DBPR/HR/FORMS/INDEX.SHTML | | | 2.PLEASE CONTACT THE WEST PALM BEACH | | | UTILITY DEPARTMENT TO DETERMINE IS A | | | GREASE TRAP IS REQUIRED AT THIS | | | LOCATION. ORD.#3434. WHAT TYPE OF FOOD | | | IS TO BE PREPARED? | | | 3.HOW IS CONDENSATE FOR COOLER TO DRAIN? | | | FLOOR DRAIN TO SANITARY OR TO A DRY WELL | | | PLEASE SHOW ON PLANS. | | | 4.BRANCH DRAIN FOR AUTOMATIC CLOTHES | | | WASHER IS REQUIRED TO BE 3" PER FBC-2004 | | | PLUMBING SEC 406.3. A CLEANOUT IS | | | REQUIRED AT 48" AFF. | | | 5.WATER HEATER IS REQUIRED TO HAVE A | | | MEANS OF EXPANTION CONTROL SEE | | | SEC.607.3. SHOW WERE HEATER PLAN IS TO | | | DRAIN. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 | | | |
|
|