Plan Review Details - Permit 06051096
Plan Review Stops For Permit 06051096
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2007-08-20 Cont ID  
Sent By kconrad Date 2007-08-20 Time 17:03 Rev Time 0.00
Received By kconrad Date 2007-08-16 Time 18:56 Sent To I
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2007-03-02 Cont ID  
Sent By lmartine Date 2007-03-02 Time 17:08 Rev Time 0.00
Received By lmartine Date 2007-03-02 Time 17:08 Sent To  
Notes
2007-03-02 17:13:51 
 "PROVISO"
  
  
 SUBMIT CURRENT PRODUCT APPROVAL FOR 'TRACO ' WINDOW
 (SINGLE HUNG OR HORIZONTAL SLIDER).
  
  
  
  
  
  
  
 L.MARTINEZ
 805-6710

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2006-10-20 Cont ID  
Sent By alange Date 2006-10-20 Time 09:36 Rev Time 0.00
Received By alange Date 2006-10-20 Time 09:36 Sent To  
Notes
2006-10-20 09:39:51DENIED
  
  
 1. 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE RE-RECORDED IF
 THE DESCRIBED IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
 6.SUBMIT TWO COMPLETE SETS OF STATE
 PRODUCT APPROVALS WIH THE APPROPRIATE
 NOA.TRACO SH WINDOW MISSING MIAMI-DADE PRODUCT
 APPROVALS.SUBMIT TWO COPIES.
  
 7.THOSE PRODUCT APPROVALS WHICH ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.WPB
 AMENDMENT TO FBC 106.3.3.
  
 8.SUBMIT TWO SETS OF TRUSS DRAWINGS
 FOR REVIEW PER PRIOR TO INSTALLATION.
 2004 FBC R-802.10.1TRUSS DRAWINGS
 SHALL BE SIGNED AND SEALED.
  
 9.A DESIGN PROFESSIONAL OR AN OWNER
 MUST ELECT ONE OR A COMBINATION OF
 LEVELS OF ALTERATION PURSUANT TO
 SECTIONS 303, 304 AND 305 OF THIS CODE.
 SHOW HOW PLANS WILL COMPLY WITH THE
 SECTION(S) SELECTED.2004 FBC EXISTING
 BUILDING 301.5
  
 12.MINIMUM FOOTING DEPTH IS 12"
 R-403.1.4HAND DRAWN CHANGES NOT
 PERMITTED.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. SUBMIT ONE COPY OF
 OLD PAGES FOR REFERENCE . A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET
 OR SPECIFICATION PAGE WHERE THE CHANGES
 CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 ART LANGE
 CONSTRUCTION SERVICES DEPARTMENT
 BUILDING PLANS EXAMINER
 561-805-6672

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-09-29 Cont ID  
Sent By alange Date 2006-09-29 Time 08:11 Rev Time 1.00
Received By alange Date 2006-09-29 Time 08:11 Sent To Z
Notes
2006-09-29 00:00:00DENIED
  
  
 1. 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE RE-RECORDED IF
 THE DESCRIBED IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
 4.SIGN OWNER/AGENT ON ENERGY CALCS
 PER 2004 FBC.
  
 6.ALL PRODUCT APPROVALS SUBMITTED WITH
 QUALITY ASSURANCE SHALL HAVE THE
 FOLLOWING STATE APPROVAL ATTACHED.
  
 SUBMIT TWO COMPLETE SETS OF STATE
 PRODUCT APPROVALS WIH THE APPROPRIATE
 NOA.
 THERMA-TRU DOOR HAS INCORRECT STATE
 APPROVAL.
 TRACO SH WINDOW HAS A FIXED WINDOW STATE
 APPROVAL ATTACHED.
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A STATE PRODUCT APPROVAL
 SHEETS THAT LISTS THE PRODUCT IDENTITY
 NUMBER FROM THE STATE. IF THE PRODUCT
 DOES NOT HAVE STATEWIDE APPROVAL, SUBMIT
 AN APPLICATION FOR LOCAL PRODUCT
 APPROVAL OR SITE SPECIFIC FORM PER RULE
 9B-72. SEE ATTACHMENT.
 WWW.FLORIDABUILDING.ORG
  
 7.THOSE PRODUCT APPROVALS WHICH ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.WPB
 AMENDMENT TO FBC 106.3.3.
  
 8.SUBMIT TWO SETS OF TRUSS DRAWINGS
 FOR REVIEW PER PRIOR TO INSTALLATION.
 2004 FBC R-802.10.1TRUSS DRAWINGS
 SHALL BE SIGNED AND SEALED.
  
 9.A DESIGN PROFESSIONAL OR AN OWNER
 MUST ELECT ONE OR A COMBINATION OF
 LEVELS OF ALTERATION PURSUANT TO
 SECTIONS 303, 304 AND 305 OF THIS CODE.
 SHOW HOW PLANS WILL COMPLY WITH THE
 SECTION(S) SELECTED.2004 FBC EXISTING
 BUILDING 301.5
  
 11.SHOW SIZE AND TYPE OF BEDROOM
 WINDOW ADJACENT TO ROOM ADDITION SO THAT
 EMERGENCY ESCAPE RESCUE OPENING SIZES
 CAN BE CHECKED.
  
 12.MINIMUM FOOTING DEPTH IS 12"
 R-403.1.4HAND DRAWN CHANGES NOT
 PERMITTED.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. SUBMIT ONE COPY OF
 OLD PAGES FOR REFERENCE . A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET
 OR SPECIFICATION PAGE WHERE THE CHANGES
 CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 ART LANGE
 CONSTRUCTION SERVICES DEPARTMENT
 BUILDING PLANS EXAMINER
 561-805-6672

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-06-28 Cont ID  
Sent By alange Date 2006-06-28 Time 14:28 Rev Time 1.50
Received By alange Date 2006-06-28 Time 14:28 Sent To  
Notes
2006-06-28 00:00:00DENIED
  
  
 1. 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE
 RE-RECORDED IF THE DESCRIBED IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 3.BASED ON ICC BUILDING VALUATION DATA
 THE PERMIT VALUE HAS BEEN REVISED TO
 $46,127.ADDITIONAL PERMIT FEES ARE
 DUE.
  
 4.SUBMIT TWO COPIES OF ENERGY CALCS
 PER 2004 FBC.
  
 5.PRODUCT APPROVALS REQUIRED FOR
 IMPACT PROTECTION FOR DOOR.
  
 6.ALL PRODUCT APPROVALS SUBMITTED WITH
 QUALITY ASSURANCE SHALL HAVE THE
 FOLLOWING STATE APPROVAL ATTACHED.
  
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A STATE PRODUCT APPROVAL
 SHEETS THAT LISTS THE PRODUCT IDENTITY
 NUMBER FROM THE STATE. IF THE PRODUCT
 DOES NOT HAVE STATEWIDE APPROVAL, SUBMIT
 AN APPLICATION FOR LOCAL PRODUCT
 APPROVAL OR SITE SPECIFIC FORM PER RULE
 9B-72. SEE ATTACHMENT.
 WWW.FLORIDABUILDING.ORG
  
 7.THOSE PRODUCT APPROVALS WHICH ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.WPB
 AMENDMENT TO FBC 106.3.3.
  
 8.SUBMIT TWO SETS OF TRUSS DRAWINGS
 FOR REVIEW PER 2004 FBC R-802.10.1
  
 9.A DESIGN PROFESSIONAL OR AN OWNER
 MUST ELECT ONE OR A COMBINATION OF
 LEVELS OF ALTERATION PURSUANT TO
 SECTIONS 303, 304 AND 305 OF THIS CODE.
 SHOW HOW PLANS WILL COMPLY WITH THE
 SECTION(S) SELECTED.2004 FBC EXISTING
 BUILDING 301.5
  
 10.SUBMIT TWO ORIGONAL SIGNED AND
 SEALED SURVEYS.FS 472.025
  
 11.SHOW SIZE AND TYPE OF BEDROOM
 WINDOW ADJACENT TO ROOM ADDITION SO THAT
 EMERGENCY ESCAPE RESCUE OPENING SIZES
 CAN BE CHECKED.
  
 12.MINIMUM FOOTING DEPTH IS 12"
 R-403.1.4
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. SUBMIT ONE COPY OF
 OLD PAGES FOR REFERENCE . A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET
 OR SPECIFICATION PAGE WHERE THE CHANGES
 CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 ART LANGE
 CONSTRUCTION SERVICES DEPARTMENT
 BUILDING PLANS EXAMINER
 561-805-6672
  

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2007-07-06 Cont ID  
Sent By btrobaug Date 2007-07-06 Time 12:29 Rev Time 0.00
Received By btrobaug Date 2007-07-06 Time 12:15 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2007-01-31 Cont ID  
Sent By btrobaug Date 2007-01-31 Time 15:28 Rev Time 0.50
Received By btrobaug Date 2007-01-31 Time 15:07 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2006-10-19 Cont ID  
Sent By btrobaug Date 2006-10-19 Time 17:16 Rev Time 0.50
Received By btrobaug Date 2006-10-19 Time 17:04 Sent To B
Notes
2006-10-19 17:16:50 
  
 NONCOMPLIANT
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE
 COMPLIANCE AND RESUBMIT FOR REVIEW.
  
 THE ENGINEER MUST DATE THE SEAL PER 61G15-23.002 FAC.
 THE DATE FOR THE CHANGES FOR COMMENTS ON THE PLAN IS
 THE ORIGINAL DATE DRAWN, PLANS ARE TO BE DATED AS
 SEALED.
  
 COMMENT FROM PREVIOUS REVIEW:
  
 3} REMOVE OLD SHEETS AND REPLACE WITH A
 NEW, CORRECTED SET. ONE SET SUBMITTED
 FOR THIS REVIEW WAS THE REDLINED SET.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2006-09-20 Cont ID  
Sent By btrobaug Date 2006-09-20 Time 07:54 Rev Time 0.50
Received By btrobaug Date 2006-09-20 Time 07:27 Sent To B
Notes
2006-09-20 00:00:00 
  
  
 NONCOMPLIANT
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} ADD RECEPTACLES PER 210.52 AND
 LIGHTING PER 210.70. ONE BEDROOM HAS NO
 LIGHTING OUTLETS OR SWITCHES.
  
 2} A RECEPTACLE IS REQUIRED IN THE HALL
 PER 210.52(H). THIS WAS REDLINED ON PLAN
 , PREVIOUS REVIEW.
  
 3} REMOVE OLD SHEETS AND REPLACE WITH A
 NEW, CORRECTED SET. ONE SET SUBMITTED
 FOR THIS REVIEW WAS THE REDLINED SET.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-06-12 Cont ID  
Sent By btrobaug Date 2006-06-12 Time 18:57 Rev Time 0.50
Received By btrobaug Date 2006-06-12 Time 18:49 Sent To P
Notes
2006-06-12 00:00:00 
 NONCOMPLIANT
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} ADD RECEPTACLES PER 210.52 AND
 LIGHTING PER 210.70. ONE BEDROOM HAS
 NONE.
  
 2} SMOKE DETECTORS ARE REQUIRED INSIDE
 AND OUT OF BEDROOMS, SHOW ON PLAN,
 R313.1 FBC.
  
 3} THERE IS NO BATH CIRCUIT ON THE PANEL
 SCHEDULE, SEE 210.11(C)(3).
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 WILLIAM R. TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 CONSTRUCTION SERVICES DEPARTMENT
 561) 805-6718

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2007-07-02 Cont ID  
Sent By adarroug Date 2007-07-02 Time 08:51 Rev Time 0.00
Received By adarroug Date 2007-07-02 Time 08:51 Sent To E
Notes
2007-07-02 08:51:32TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2007-01-31 Cont ID  
Sent By adarroug Date 2007-01-31 Time 11:03 Rev Time 0.00
Received By adarroug Date 2007-01-31 Time 11:03 Sent To E
Notes
2007-01-31 11:04:08TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2007-01-22 Cont ID  
Sent By adarroug Date 2007-01-22 Time 09:00 Rev Time 0.00
Received By adarroug Date 2007-01-22 Time 09:00 Sent To  
Notes
2007-01-22 09:01:02TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-10-10 Cont ID  
Sent By adarroug Date 2006-10-10 Time 19:53 Rev Time 0.00
Received By adarroug Date 2006-10-10 Time 19:53 Sent To E
Notes
2006-10-10 19:54:24TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-10-05 Cont ID  
Sent By adarroug Date 2006-10-05 Time 09:53 Rev Time 0.00
Received By adarroug Date 2006-10-05 Time 09:53 Sent To Z
Notes
2006-10-05 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-09-14 Cont ID  
Sent By adarroug Date 2006-09-14 Time 15:42 Rev Time 0.00
Received By adarroug Date 2006-09-14 Time 15:41 Sent To S
Notes
2006-09-14 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-06-01 Cont ID  
Sent By adarroug Date 2006-06-01 Time 16:46 Rev Time 0.00
Received By adarroug Date 2006-06-01 Time 16:45 Sent To E
Notes
2006-06-01 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-06-28 Cont ID  
Sent By alange Date 2006-06-28 Time 14:28 Rev Time 0.00
Received By alange Date 2006-05-26 Time 14:04 Sent To  
Notes
2006-05-26 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2006-06-16 Cont ID  
Sent By tgordon Date 2006-06-16 Time 14:36 Rev Time 0.15
Received By tgordon Date 2006-06-16 Time 14:36 Sent To B
Notes
2006-06-16 00:00:00NO MECHANICAL PLANS SUBMITTED, AND NO
 MECHANICAL PERMIT NUMBER APPLIED FOR AT
 THIS TIME.

Review Stop P PLUMBING
Rev No 3 Status P Date 2007-07-09 Cont ID  
Sent By jleech Date 2007-07-09 Time 09:39 Rev Time 0.00
Received By jleech Date 2007-07-09 Time 09:39 Sent To B
Notes
2007-07-09 09:42:23REVISED RISER DIAGRAM

Review Stop P PLUMBING
Rev No 2 Status P Date 2007-02-12 Cont ID  
Sent By jleech Date 2007-02-12 Time 07:31 Rev Time 0.00
Received By jleech Date 2007-02-12 Time 07:31 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2006-06-16 Cont ID  
Sent By jleech Date 2006-06-16 Time 09:11 Rev Time 0.00
Received By jleech Date 2006-06-16 Time 09:11 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 5 Status P Date 2007-03-05 Cont ID  
Sent By jroach Date 2007-03-05 Time 13:54 Rev Time 0.00
Received By jroach Date 2007-03-05 Time 13:54 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 4 Status F Date 2007-01-30 Cont ID  
Sent By mmclean Date 2007-01-30 Time 15:48 Rev Time 0.00
Received By mmclean Date 2007-01-30 Time 15:26 Sent To I
Notes
2007-01-30 15:36:46DENIED,
 1. PLEASE MARK ON THE TWO COPIES OF SURVEYS THE REMOVAL
 OF THE EXISTING SHED AS INDICATED ON THE FOUNDATION
 PLAN.
 2. ANY FUTURE SHED MUST MEET THE 6FT SEPARATION FROM
 MAIN STRUCTURE.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720

Review Stop Z ZONING
Rev No 3 Status F Date 2006-10-10 Cont ID  
Sent By jroach Date 2006-10-10 Time 14:53 Rev Time 0.00
Received By jroach Date 2006-10-10 Time 14:53 Sent To I
Notes
2006-10-10 14:58:08***FAILED***
  
 1) WEST ELEVATION DOES NOT MATCH THE FLOOR PLAN.FLOOR
 PLAN INDICATES A DOORWAY INTO THE HALLWAY, WHICH IS NOT
 SHOWN ON THE ELEVATIONS.
  
 2) THE SIZE OF THE ADDITION SHOWN ON THE SURVEY DOES
 NOT MATCH THE FLOOR PLANS.
  
 3) PLEASE VERIFY THAT THE CARPORT AND THE SHED WILL BE
 DEMOLISHED...OR IS THE SHED REMAINING?
  
 QUESTIONS/COMMENTS, PLEASE CONTACT JOHN ROACH, SENIOR
 PLANNER, AT (561) 822-1435.

Review Stop Z ZONING
Rev No 2 Status F Date 2006-09-29 Cont ID  
Sent By mmclean Date 2006-09-29 Time 14:34 Rev Time 0.00
Received By mmclean Date 2006-09-29 Time 14:34 Sent To I
Notes
2006-09-29 00:00:00DENIED,
 1. THE PROPOSED WORK ON THE TWO COPIES
 OF SURVEYS DOES NOT MATCH THE FLOOR
 PLANS.
 2. THE SURVEYS SHOWS THE PROPOSED WORK
 NOT ATTACHED TO THE EXISTING STRUCTURE.
 3. FLOOR PLANS SHOWS THE PROPOSED
 ATTACHED TO THE MAIN STRUCTURE WITH
 INTERIOR ACCESS.
 4. NEED TO PROVIDE THE SIDE SETBACK OF
 THE PROPOSED FROM THE SIDE PROPERTY
 LINE. PLEASE MARK ON TWO COPIES OF
 SURVEYS.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720

Review Stop Z ZONING
Rev No 1 Status F Date 2006-05-27 Cont ID  
Sent By mmclean Date 2006-05-27 Time 17:14 Rev Time 0.00
Received By mmclean Date 2006-05-27 Time 17:14 Sent To I
Notes
2006-05-27 00:00:00DENIED,
 1. MUST SHOW THE LOCATION OF THE
 PROPOSED WORK ON TWO COPY OF SURVEY WITH
 SETBACKS
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720