Plan Review Details - Permit 06051051
Plan Review Stops For Permit 06051051
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2006-06-12 Cont ID  
Sent By rnuquist Date 2006-06-12 Time 19:03 Rev Time 0.00
Received By rnuquist Date 2006-06-12 Time 19:03 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2007-05-17 Cont ID  
Sent By btrobaug Date 2007-05-17 Time 16:19 Rev Time 0.33
Received By btrobaug Date 2007-05-17 Time 16:03 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-08-07 Cont ID  
Sent By btrobaug Date 2006-08-07 Time 13:24 Rev Time 0.50
Received By btrobaug Date 2006-08-07 Time 12:33 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2006-07-19 Cont ID  
Sent By jleahy Date 2006-07-18 Time 13:38 Rev Time 0.45
Received By jleahy Date 2006-07-18 Time 13:38 Sent To  
Notes
2006-07-19 00:00:00SEE 1ST REVIEW FOR GROUPING OF
 DISCONNECTS PER 230.71 AND 225.31, AND
 230.6JLEAHY

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-06-13 Cont ID  
Sent By btrobaug Date 2006-06-13 Time 16:14 Rev Time 0.50
Received By btrobaug Date 2006-06-13 Time 16:00 Sent To P
Notes
2006-06-13 00:00:00 
  
 NONCOMPLIANT
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} 225.31 DISCONNECTING MEANS.
 MEANS SHALL BE PROVIDED FOR
 DISCONNECTING ALL UNGROUNDED CONDUCTORS
 THAT SUPPLY OR PASS THROUGH THE BUILDING
 OR STRUCTURE. THIS MEANS ON THE
 BUILDING, NOT THE GENERATOR. SEE 225.36.
  
 225.32 LOCATION.
 THE DISCONNECTING MEANS SHALL BE
 INSTALLED EITHER INSIDE OR OUTSIDE OF
 THE BUILDING OR STRUCTURE SERVED OR
 WHERE THE CONDUCTORS PASS THROUGH THE
 BUILDING OR STRUCTURE. THE DISCONNECTING
 MEANS SHALL BE AT A READILY ACCESSIBLE
 LOCATION NEAREST THE POINT OF ENTRANCE
 OF THE CONDUCTORS. FOR THE PURPOSES OF
 THIS SECTION, THE REQUIREMENTS IN 230.6
 SHALL BE PERMITTED TO BE UTILIZED.
  
 230.72 GROUPING OF DISCONNECTS.
 (A) GENERAL. THE TWO TO SIX DISCONNECTS
 AS PERMITTED IN 230.71 SHALL BE GROUPED.
 EACH DISCONNECT SHALL BE MARKED TO
 INDICATE THE LOAD SERVED.
  
 PLEASE LOCATE ALL SERVICE EQUIPMENT ON
 THE PLAN, METER ENCLOSURE, DISCONNECTS
 AND PANELS, SO THAT COMPLIANCE WITH
 ARTICLES 225 AND 230 CAN BE REVIEWED.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 WILLIAM R. TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 CONSTRUCTION SERVICES DEPARTMENT
 561) 805-6718
  

Review Stop G GAS REVIEW
Rev No 1 Status P Date 2006-06-15 Cont ID  
Sent By mperson Date 2006-06-15 Time 08:05 Rev Time 0.33
Received By mperson Date 2006-06-15 Time 08:05 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2007-05-17 Cont ID  
Sent By adarroug Date 2007-05-17 Time 15:39 Rev Time 0.00
Received By adarroug Date 2007-05-17 Time 15:39 Sent To E
Notes
2007-05-17 15:41:28TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-07-05 Cont ID  
Sent By adarroug Date 2006-07-05 Time 14:14 Rev Time 0.00
Received By adarroug Date 2006-07-05 Time 14:14 Sent To E
Notes
2006-07-05 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-06-02 Cont ID  
Sent By adarroug Date 2006-06-02 Time 14:01 Rev Time 0.00
Received By adarroug Date 2006-06-02 Time 14:01 Sent To E
Notes
2006-06-02 00:00:00TO "GEN-RES" "E"

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-06-19 Cont ID  
Sent By tgordon Date 2006-06-19 Time 10:32 Rev Time 0.00
Received By tgordon Date 2006-05-25 Time 16:14 Sent To  
Notes
2006-05-25 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2006-06-19 Cont ID  
Sent By tgordon Date 2006-06-19 Time 10:29 Rev Time 0.15
Received By tgordon Date 2006-06-19 Time 10:29 Sent To  
Notes
2006-06-19 00:00:00*** PROVISO ***
 PER 2004 FBC, FUEL GAS - POWERED
 EQUIPMENT - PERMANENTLY INSTALLED
 EQUIPMENT POWERED BY INTERNAL COMBUSTION
 ENGINES SHALL BE INSTALLED IN ACCORDANCE
 WITH MANUFACTURE'S INSTALLATION
 INSTRUCTIONS AND NFPA 37.
  
 NFPA 37 INSTALLATION & USE OF STATIONARY
 COMBUSTION ENGINES & GAS TURBINES:
 4.1.4ENGINES (GENERATORS) LOCATED
 OUTDOORS SHALL BE MINIMUM OF 5 FT FROM
 OPENINGS IN WALLS & AT LEAST 5 FT FROM
 STRUCTURES HAVING COMBUSTIBLE WALLS.A
 MINIMUM CLEARANCE IS NOT REQUIRED WHEN
 (1) THE ADJACENT WALL HAS A MINIMUM FIRE
 RESISTANCE RATING OF 1 HOUR OR (2) THE
 WEATHERPROOF ENCLOSURE IS CONSTRUCTED OF
 NON-COMBUSTIBLE MATERIALS, AND IT HAS
 BEEN DEMONSTRATED THAT A FIRE WITHIN THE
 ENCLOSURE WILL NOT IGNITE COMBUSTIBLE
 MATERIALS OUTSIDE THE ENCLOSURE.
 A.8.2.3.1EXHAUST SYSTEMS SHOULD NOT
 TERMINATE UNDER STRUCTURES OR WHERE THE
 EXHAUST MIGHT BE DRAWN INTO THE
 VENTILATION INTAKES.
  
 2004 FMC 804.3.5 #3, WHERE THE
 TERMINATION IS LOCATED BELOW AN ADJACENT
 ROOF STRUCTURE, THE TERMINATION POINT
 SHALL BE LOCATED AT LEAST 3 FT FROM THE
 ROOF STRUCTURE.
  
 PLEASE NOTE, WHILE ZONING ALLOWS
 MECHANICAL EQUIPMENT TO ENCROACH 4 FT
 INTO THE SETBACK, GENERATORS SHALL
 MAINTAIN THE REQUIRED ABOVE MENTIONED
 CLEARANCES TO THE ADJACENT PROPERTY
 STRUCTURES, I.E. FENCE, BUILDING,
 WINDOWS, DOORS, OR OPENINGS.
  
 PROVIDE MANUFACTURE'S INSTALLATION
 INSTRUCTIONS AT THE JOBSITE FOR THE
 FIELD INSPECTOR.
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.
  

Review Stop P PLUMBING
Rev No 1 Status N Date 2006-06-15 Cont ID  
Sent By mperson Date 2006-06-15 Time 08:04 Rev Time 0.00
Received By mperson Date 2006-06-15 Time 08:04 Sent To G
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2006-05-27 Cont ID  
Sent By mmclean Date 2006-05-27 Time 22:16 Rev Time 0.00
Received By mmclean Date 2006-05-27 Time 22:16 Sent To I
Notes
2006-05-27 00:00:00NOTE: GENERATOR CAN ONLY ENCROACH 4FT
 INTO REQUIRED SETBACK


Account Summary | Usage Policy | Privacy Policy