Plan Review Details - Permit 06050971
Plan Review Stops For Permit 06050971
Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status P Date 2007-08-25 Cont ID  
Sent By amorse Date 2007-08-25 Time 12:00 Rev Time 0.00
Received By amorse Date 2007-08-25 Time 12:00 Sent To Z
Notes
2007-08-25 12:02:12 
  
 PASSED
  
 REVISION FOR AS BUILT CHANGES TO WALL SECTION ON A/2
 SENT TO CHRIS IN ZONING FOR CLARIFICATION
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2007-06-21 Cont ID  
Sent By amorse Date 2007-06-21 Time 16:57 Rev Time 0.00
Received By amorse Date 2007-06-21 Time 16:57 Sent To PC
Notes
2007-06-21 17:01:31 
  
 PASSED
  
 REVISION OK BUT ADDITIONS ARE CONSIDERED NEW
 CONSTRUCTION AND SUBJECT TO THE PROVISIONS OF THE
 FLORIDA BUILDING CODE, AS SUCH IMPACT PROTECTION IS
 REQUIRED FOR THE NEW WINDOW AND A SHUTTER PERMIT IS
 REQUIRED.
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2007-06-05 Cont ID  
Sent By amorse Date 2007-06-05 Time 17:21 Rev Time 0.00
Received By amorse Date 2007-06-05 Time 17:21 Sent To E
Notes
2007-06-05 17:34:43 
  
 DENIED
  
 1) PROVIDE 2 COPIES OF FLORIDA STATEWIDE PRODUCT
 APPROVAL FOR THE HORIZONTAL SLIDING WINDOW UNIT, IF TWO
 ARE CONNECTED TOGETHER A PRODUCT APPROVAL FOR MULLIONS
 WILL ALSO BE REQUIRED.
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2006-10-03 Cont ID  
Sent By amorse Date 2006-10-03 Time 16:44 Rev Time 0.00
Received By amorse Date 2006-10-03 Time 16:45 Sent To PC
Notes
2006-10-03 00:00:00 
  
 *****REVISION # 1******
  
 CHANGE OF FLOOR PLAN, OK AS REVISED

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2006-08-11 Cont ID  
Sent By amorse Date 2006-08-11 Time 10:35 Rev Time 0.00
Received By amorse Date 2006-08-11 Time 10:35 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-06-29 Cont ID  
Sent By amorse Date 2006-06-29 Time 13:44 Rev Time 1.00
Received By amorse Date 2006-06-29 Time 13:44 Sent To PC
Notes
2006-06-29 00:00:00 
  
 DENIED
  
 1) PROVIDE DETAIL ON ATTACHMENT OF 2X6
 LEDGER TO WALL
  
 2) CLARIFY WHETHER ROOF IS STICK FRAMED
 AS IN FRAMING PLAN 3/A1 OR TRUSSES AS ON
 WALL SECTION 3/A2. IF FRAMED PROVIDE
 MORE DETAILS (CEILING JOIST LAYOUT AND
 CONNETION, RIDGE BOARD CONNECTION, ATTIC
 ACCESS, ETC.)
  
 3) THE CLAIMED VALUATION ON THE PERMIT
 APPLICATION IS LOW. FOR PERMITTING
 PURPOSES, VALUATION OF BUILDINGS AND
 SYSTEMS SHALL BE THE TOTAL REPLACEMENT
 COST EXCLUDING LAND VALUE. OUR VALUATION
 REFERENCE IS ICC (BVD), MARSHALL-SWIFT
 AND MEANS COST ANALYSIS SERVICES PER
 108.3 FBC*
  
 4) THE STATE OF FLORIDA REQUIRES
 COLLECTION OF A RADON SURCHARGE ON ALL
 NEW CONSTRUCTION COMPUTED ON UNDER ROOF
 FLOOR SPACE PER 10D-91 FAC
  
 5) BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SETS OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561) 233-5025 FOR MORE
 INFORMATION.
  
 6) PROVIDE WOOD CONNECTOR TYPE AT DOUBLE
 TOP PLATE TO STUD CONNECTION
  
 7) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT IS REQUIRED PRIOR TO
 A PERMIT BEING ISSUED
  
 ****NOTE****
 THE PREFFERED METHOD FOR PRODUCT
 APPROVAL FOR WOOD CONNECTORS IS TO
 DOWNLOAD THE SIMPSON-TIE INDEX FOR
 FLORIDA APPROVALS AND MARK THE ONES
 USED. SEE ENCOSED PRODUCT APPROVAL.
 THIS SHOULD MAKE IT EASIER FOR FUTURE
 APPLICATIONS PLEASE HAVE DESIGNER
 APPROVE THESE NEW SUBMITTALS
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716
  
  
  
  
  
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2007-06-06 Cont ID  
Sent By btrobaug Date 2007-06-06 Time 08:44 Rev Time 0.50
Received By btrobaug Date 2007-06-06 Time 08:35 Sent To PC
Notes
2007-06-06 08:46:12 
  
 CALLED OWNER, SHE DOES NOT WANT PLUMBING REVIEWED, NO
 CHANGE FROM ORIGINAL PLAN./WRT.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2006-06-12 Cont ID  
Sent By btrobaug Date 2006-06-12 Time 18:29 Rev Time 0.33
Received By btrobaug Date 2006-06-12 Time 18:18 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2007-08-22 Cont ID  
Sent By adarroug Date 2007-08-22 Time 14:00 Rev Time 0.00
Received By adarroug Date 2007-08-22 Time 14:00 Sent To Z
Notes
2007-08-22 14:01:16TO "Z" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2007-06-20 Cont ID  
Sent By adarroug Date 2007-06-20 Time 11:33 Rev Time 0.00
Received By adarroug Date 2007-06-20 Time 11:33 Sent To M
Notes
2007-06-20 11:33:46TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2007-05-29 Cont ID  
Sent By adarroug Date 2007-05-29 Time 13:19 Rev Time 0.00
Received By adarroug Date 2007-05-29 Time 13:19 Sent To M
Notes
2007-05-29 13:20:06TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-10-03 Cont ID  
Sent By adarroug Date 2006-10-03 Time 14:05 Rev Time 0.00
Received By adarroug Date 2006-10-03 Time 14:05 Sent To B
Notes
2006-10-03 00:00:00TO "AMORSE" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-08-07 Cont ID  
Sent By adarroug Date 2006-08-07 Time 14:38 Rev Time 0.00
Received By adarroug Date 2006-08-07 Time 14:38 Sent To P
Notes
2006-08-07 00:00:00TO "P" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-07-28 Cont ID  
Sent By adarroug Date 2006-07-28 Time 15:59 Rev Time 0.00
Received By adarroug Date 2006-07-28 Time 15:59 Sent To B
Notes
2006-07-28 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-06-02 Cont ID  
Sent By adarroug Date 2006-06-02 Time 14:13 Rev Time 0.00
Received By adarroug Date 2006-06-02 Time 14:13 Sent To E
Notes
2006-06-02 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2006-06-29 Time   Rev Time 0.00
Received By adarroug Date 2006-05-24 Time 18:39 Sent To  
Notes
2006-05-24 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2007-06-20 Cont ID  
Sent By tgordon Date 2007-06-20 Time 16:00 Rev Time 0.25
Received By tgordon Date 2007-06-20 Time 16:00 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2007-05-29 Cont ID  
Sent By tgordon Date 2007-05-29 Time 14:26 Rev Time 0.25
Received By tgordon Date 2007-05-29 Time 14:26 Sent To B
Notes
2007-05-29 14:34:45*** DENIED ***
 1) PLEASE SHOW HOW MAKE-UP AIR IS BEING PROVIDED FOR
 CLOTHES DRYER, AS THEIR IS A GAS WATER HEATER IN THE
 SAME ROOM, SEE 2004 FBC/R M1701.2.
  
 2) PLEASE SHOW THE SIZE OF THE SUPPLY AIR GRILL ON THE
 PLANS.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2006-10-03 Cont ID  
Sent By tgordon Date 2006-06-14 Time 11:22 Rev Time 0.00
Received By amorse Date 2006-06-14 Time 16:43 Sent To  
Notes
2006-06-14 00:00:00NO MECHANICAL PLANS SUBMITTED, AND NO
 MECHANICAL PERMIT NUMBER APPLIED FOR AT
 THIS TIME.

Review Stop P PLUMBING
Rev No 2 Status P Date 2006-08-10 Cont ID  
Sent By jleech Date 2006-08-10 Time 08:44 Rev Time 0.00
Received By jleech Date 2006-08-10 Time 08:44 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2006-06-14 Cont ID  
Sent By jleech Date 2006-06-14 Time 09:18 Rev Time 0.00
Received By jleech Date 2006-06-14 Time 09:18 Sent To M
Notes
2006-06-14 00:00:00DENIED;
 A SANITARY RISER DIAGRAM IS REQUIRED
 PER.FBC-2004 CHAPTER 1,
 SEC.106.3.5.4(9).
 SHOW HOW W/M DRAIN WILL BE VENTED,SIZE
 OF DISCHARGE PIPE AND WHERE IT WILL TIE
 INTO THE SEWER. FBC-2004 PLUMBING
 SEC.406.3 REQUIRES W/M DRAIN TO BE 3"
 AND A CLEANOUT IS REQUIRED AT 48" ABOVE
 FINISH FLOOR.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop Z ZONING
Rev No 3 Status P Date 2007-08-23 Cont ID  
Sent By choops Date 2007-08-23 Time 18:23 Rev Time 0.00
Received By choops Date 2007-08-23 Time 18:23 Sent To B
Notes
2007-08-23 18:25:22***APPROVED******REVISION - AS BUILT CHANGES TO WALL
 A/2***
  

Review Stop Z ZONING
Rev No 2 Status P Date 2006-08-05 Cont ID  
Sent By mmclean Date 2006-08-05 Time 06:10 Rev Time 0.00
Received By mmclean Date 2006-08-05 Time 06:10 Sent To I
Notes
2006-08-05 00:00:00ADDITION OF LAUNDRY ONLY.

Review Stop Z ZONING
Rev No 1 Status F Date 2006-05-27 Cont ID  
Sent By mmclean Date 2006-05-27 Time 19:16 Rev Time 0.00
Received By mmclean Date 2006-05-27 Time 19:16 Sent To I
Notes
2006-05-27 00:00:00DENIED,
 1. MUST PROVIDE TWO COPY OF CURRENT
 SURVEY SHOWING THE LOCATION OF THE
 PROPOSED WORK WITH SETBACKS.
  
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720