Plan Review Details - Permit 06050873
| Plan Review Stops For Permit 06050873 |
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2006-06-08 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-06-08 |
Time |
08:20 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2006-06-08 |
Time |
08:20 |
Sent To |
PC |
|
| Notes |
| 2006-06-08 00:00:00 | IF DRYER ROOM IS A CONFINED SPACE, OPEN- | | | INGS REQUIRED PER SECTION 304.5 OR | | | SECTION 304.6 SHALL BE INSTALLED. | | | MINIMUM 1,100 CUBIC FEET REQUIRED. | | | | | | IF WATER HEATER ROOM IS A CONFINED | | | SPACE, OPENINGS REQUIRED PER SECTION | | | 304.5 OR SECTION 304.6 SHALL BE | | | INSTALLED. | | | MINIMUM 3,750 CUBIC FEET REQUIRED. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2006-06-01 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-06-01 |
Time |
09:41 |
Rev Time |
0.45 |
| Received By |
mperson |
Date |
2006-06-01 |
Time |
09:40 |
Sent To |
PC |
|
| Notes |
| 2006-06-01 00:00:00 | ******DENIED****** | | | REFERENCE: FBC-2004 FUEL GAS | | | FBC-2004 CHAPTER 1 | | | | | | THE FOLLOWING INFORMATION IS REQUIRED | | | FOR PLAN REVIEW FOR A GAS PERMIT: | | | | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2004 | | | FUEL GAS CODE. | | | 2. SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE BEING USED. | | | 3. PLEASE HAVE THE PERSON TAKING | | | RESPONSIBILITY OF THE DRAWING PRINT, AND | | | SIGN NAME, AND DATE DRAWING. | | | 4. PLEASE SEE CORRECTED DRAWING AND | | | ATTACHED CITY OF WEST PALM BEACH, GAS | | | PERMIT APPLICATION REQUIREMENTS FOR | | | REFERENCE FOR RESUBMITTAL | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-06-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-07 |
Time |
10:04 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-07 |
Time |
10:04 |
Sent To |
P |
|
| Notes |
| 2006-06-07 00:00:00 | TO "G" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-06-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-01 |
Time |
10:03 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-24 |
Time |
14:26 |
Sent To |
|
|
| Notes |
| 2006-05-24 00:00:00 | TO "G" BOX |
|
|
|