Plan Review Details - Permit 06050858
Plan Review Stops For Permit 06050858
Review Stop AD ADDRESSING
Rev No 3 Status P Date 2006-07-12 Cont ID  
Sent By lursu Date 2006-07-12 Time 10:58 Rev Time 0.00
Received By lursu Date 2006-07-12 Time 10:58 Sent To  
Notes
2006-07-12 00:00:00UNIT B 17 IS UNIT 140 FOR BOLUFE:
 700 S ROSEMARY AVE # 140UNDER PCN =
 74434321130020010

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2006-06-27 Cont ID  
Sent By lursu Date 2006-06-27 Time 08:16 Rev Time 0.00
Received By lursu Date 2006-06-26 Time 13:25 Sent To  
Notes
2006-06-26 00:00:00 
 EXT #0021 FOR 700 S ROSEMARY # 176 WAS
 CREATED .ON THE APPLICATION CORRECTION
 MUST BE DONE FOR THE UNIT NUMBER TO
 REFLECT 176 INSTAED OF 140 AND ALSO THE
 OWNER
 INFO( MAILING ADDRESS)MUST BE CORRECTED
 TO MATCH PAPA.
 ALSO THE SITE PLANS MUST INDICATE
 THE CORRECT SITE ADDRESS INSTEAD OF 600
 ROSEMARY UNIT B17A

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2006-08-09 Cont ID  
Sent By alange Date 2006-08-09 Time 13:07 Rev Time 0.00
Received By alange Date 2006-08-07 Time 11:37 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2006-07-11 Cont ID  
Sent By alange Date 2006-07-11 Time 14:41 Rev Time 0.00
Received By alange Date 2006-07-11 Time 14:41 Sent To AD
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-06-27 Cont ID  
Sent By alange Date 2006-06-27 Time 10:30 Rev Time 0.00
Received By alange Date 2006-06-27 Time 10:01 Sent To  
Notes
2006-06-27 00:00:00DENIED
  
  
 1. 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE
 RE-RECORDED IF THE DESCRIBED IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
 3. KAWNEER COMPANY SERIES 1600 HAS A
 STATE PRODUCT APPROVAL REQUIRED.
 ALL PRODUCT APPROVALS SUBMITTED WITH
 QUALITY ASSURANCE SHALL HAVE THE
 FOLLOWING STATE APPROVAL ATTACHED.
  
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A STATE PRODUCT APPROVAL
 SHEETS THAT LISTS THE PRODUCT IDENTITY
 NUMBER FROM THE STATE. IF THE PRODUCT
 DOES NOT HAVE STATEWIDE APPROVAL, SUBMIT
 AN APPLICATION FOR LOCAL PRODUCT
 APPROVAL OR SITE SPECIFIC FORM PER RULE
 9B-72. SEE ATTACHMENT.
 WWW.FLORIDABUILDING.ORG
  
 5.A DESIGN PROFESSIONAL OR AN OWNER
 MUST ELECT ONE OR A COMBINATION OF
 LEVELS OF ALTERATION PURSUANT TO
 SECTIONS 303, 304 AND 305 OF THIS CODE.
 SHOW HOW PLANS WILL COMPLY WITH THE
 SECTION(S) SELECTED.2004 FBC EXISTING
 BUILDING 301.5
  
 6.DRESSING ROOMS SHALL COMPLY WITH FBC
 11-4.35SHOW THE FOLLOWING.CLEAR
 FLOOR SPACE, BENCH AND MIRROR.
  
 7.SHOW SALES COUNTER COMPLIANCE WITH
 FBC 11-7.2.
  
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. SUBMIT ONE COPY OF
 OLD PAGES FOR REFERENCE. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET
 OR SPECIFICATION PAGE WHERE THE CHANGES
 CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 ART LANGE
 CONSTRUCTION SERVICES DEPARTMENT
 BUILDING PLANS EXAMINER
 561-805-6672
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-05-25 Cont ID  
Sent By alange Date 2006-05-25 Time 08:30 Rev Time 0.00
Received By alange Date 2006-05-25 Time 08:21 Sent To  
Notes
2006-05-25 00:00:00DENIED
  
  
 1. 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE
 RE-RECORDED IF THE DESCRIBED IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
 2.PRODUCT APPROVALS REQUIRED FOR STORE
 FRONT.
  
 3.ALL PRODUCT APPROVALS SUBMITTED WITH
 QUALITY ASSURANCE SHALL HAVE THE
 FOLLOWING STATE APPROVAL ATTACHED.
  
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A STATE PRODUCT APPROVAL
 SHEETS THAT LISTS THE PRODUCT IDENTITY
 NUMBER FROM THE STATE. IF THE PRODUCT
 DOES NOT HAVE STATEWIDE APPROVAL, SUBMIT
 AN APPLICATION FOR LOCAL PRODUCT
 APPROVAL OR SITE SPECIFIC FORM PER RULE
 9B-72. SEE ATTACHMENT.
 WWW.FLORIDABUILDING.ORG
  
 4.THOSE PRODUCT APPROVALS WHICH ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.WPB
 AMENDMENT TO FBC 106.3.3.
  
 5.A DESIGN PROFESSIONAL OR AN OWNER
 MUST ELECT ONE OR A COMBINATION OF
 LEVELS OF ALTERATION PURSUANT TO
 SECTIONS 303, 304 AND 305 OF THIS CODE.
 SHOW HOW PLANS WILL COMPLY WITH THE
 SECTION(S) SELECTED.2004 FBC EXISTING
 BUILDING 301.5
  
 6.DRESSING ROOMS SHALL COMPLY WITH FBC
 11-4.35SHOW THE FOLLOWING.CLEAR
 FLOOR SPACE, BENCH AND MIRROR.
  
 7.SHOW SALES COUNTER COMPLIANCE WITH
 FBC 11-7.2.
  
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. SUBMIT ONE COPY OF
 OLD PAGES FOR REFERENCE. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET
 OR SPECIFICATION PAGE WHERE THE CHANGES
 CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 ART LANGE
 CONSTRUCTION SERVICES DEPARTMENT
 BUILDING PLANS EXAMINER
 561-805-6672
  

Review Stop E ELECTRICAL
Rev No 6 Status P Date 2006-08-22 Cont ID  
Sent By btrobaug Date 2006-08-22 Time 17:46 Rev Time 0.75
Received By btrobaug Date 2006-08-22 Time 17:29 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 5 Status F Date 2006-08-05 Cont ID  
Sent By dpalmer Date 2006-08-05 Time 13:05 Rev Time 0.00
Received By dpalmer Date 2006-08-05 Time 13:01 Sent To  
Notes
2006-08-05 00:00:00****** UNSAT ********
  
 1) NOTE: PLEASE SEE ALL NEW LV , SPKRS,
 CAMERAS ETC ARE NOW BEING ADDED TO
 PLANS, HOWEVER THIS IS REQUIRED UNDER A
 SEPARATE AS THIS WAS NOT PART OF THE
 ORIGIANL PLANS.
 PLEASE PROVIDE ON SEPARATE PLANS AND
 PERMIT APPLICATION AND FEES FOR ALL
 LABOUR AND MATERIALS.
 FBC 106.1.2,108.3
  
  
 ** PLEASE KNOW, WHEN REVISING PLANS FOR
 LV , PLEASE BE SURE TO INDICATE THE HR
 LOCATION OF THE LV FOR CAMERAS ETC
  
 ** LV ON THESE PLANS MAY ONLY BE SHOWN
 AS A REFERENCE UNDER SEPARATE PERMIT
 ONCE THE OTHER LV PERMIT IS ISSUED.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2006-07-07 Cont ID  
Sent By dpalmer Date 2006-07-07 Time 18:21 Rev Time 0.00
Received By dpalmer Date 2006-07-07 Time 18:20 Sent To  
Notes
2006-07-07 00:00:00ELECTRICAL PLANS STAMPED.
 ADDRESSING STILL NEEDS TO BE CORRECTED.

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2006-06-23 Cont ID  
Sent By dpalmer Date 2006-06-23 Time 17:35 Rev Time 0.00
Received By dpalmer Date 2006-06-23 Time 17:16 Sent To  
Notes
2006-06-23 00:00:00*** UNSAT ***
  
 ** PLEASE KNOW, ELECTRICAL PLANS HAVE
 BEEN VOIDED. PLEASE SEE NOTES BELOW.
  
  
 1) NOTE: PLEASE SEE MISSING INFORMATION
 REQUIRED ON TITLE BLOCKS. PLEASE SEE
 MISSING THE PRINTED NAME OF ENGINEER AS
 REQUIRED PER FAC 61G15-23.002.
 PLEASE SEE ABOVE AND 61G1-16.004.
 PLEASE ALSO SEE ADDRESSING AND SUITE #
 ON PLANS ARE NOT CORRECT.
 PLEASE SEE FRONT COVER SHEET INDICATES
 600 S ROSEMARY WHEN SITE IS LOCATED AT
 700 S. ROSEMARY. PLEASE BE SURE ALL
 TITLE BLOCKS ARE REVISED.
 PLEASE ALSO SEE THE SUITE # OF B-17 IS
 NOT CURRENT.
 PLEASE KNOW, THIS IS REQUIRED FOR ALL
 TRADES AND FOR ALL SHEETS WHETHER OR NOT
 COMMENT IS MADE BY OTHER REVIEWER.
  
 2) NOTE; PLEASE SEE PLANS NOTES MENTIONS
 THE PLANS ARE DESIGNED UNDER THE 2004
 FBC, HOWEVER PLEASE SEE FBC 2004 CHAPTER
 13 FOR NEW REQUIREMENTS WHICH COULD BE
 LOCATED ON PLANS.
 PLEASE PROVIDE AUTOMATED LIGHTING
 CONTROLS AS REQUIRED PER
 13-415.1.ABC.1.1, .1.2 AND .1.3
 PLEASE LIST SCHEDULING, OVER-RIDE
 LOCATIONS AS REQUIRED ALONG WITH THE
 TIME LIMITS ON THE OVER-RIDE DEVICES
 USED IN CONJUNCTION WITH THE NEW
 LIGHTING CONTROL SYSTEM.
 PLEASE SEE 13-415.1.AB.1 AND
 13-415.2.ABC.1 FOR MIN CALCULATIONS
 REQUIRED FOR ALL LIGHTING IN AREAS AND
 THE MAX ALLOWED LIGHTING DENSITIES,
 PLEASE SEE TABLES AND DETAIL WHICH
 OPTION IS BEING USED.
 PLEASE SEE ALL OF 13-413/415
  
 3) NOTE: PLEASE SUBMIT AIC RATINGS FOR
 ALL NEW SERVICE EQUIPMENT BEING INSTALL-
 ED. MAINS/BRKRS AND PANELS ARE ALL TO BE
 RATED FOR THE AVAILABLE FAULT CURRENT.
 PER 110.9/215.5
 ** PLEASE SEE THE RATING OF 25K IS SHOWN
 FOR THE 120/208V "LV" PANEL, BUT NOT FOR
 "HV" OR THE NEW MAIN DISCONNECT ON THE
 LOAD SIDE OF THE METER IN MAIN
 ELECTRICAL ROOM.
  
 4) NOTE: PLEASE CORRELATE AHU LOADS AS
 PANEL SCHEDULE INDICATES 12,135VA, YET
 LOAD CALCULATIONS INDICATE 10KW?
 215.5
  
 ** PLEASE KNOW, IF PLANS COME BACK WITH
 OUT ANY OTHER COMMENTS FROM ANY TRADE(S)
 THEN A "RESUB" FEE WILL NOT BE REQUIRED.
 HOWEVER IF THERE ARE ANY COMMENTS, THEN
 THE RESUB FEE WILL BE ASSESSED.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-08-22 Cont ID  
Sent By btrobaug Date 2006-06-21 Time 19:21 Rev Time 0.33
Received By btrobaug Date 2006-06-21 Time 19:01 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-05-24 Cont ID  
Sent By btrobaug Date 2006-05-24 Time 11:57 Rev Time 1.00
Received By btrobaug Date 2006-05-23 Time 17:58 Sent To  
Notes
2006-05-24 00:00:00 
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} HAVING ADDED A DISCONNECTING MEANS
 AND A METER, PLEASE SHOW COMPLIANCE WITH
 230.71, NUMBER OF DICONNECTS, A RISER
 WILL SUFFICE.
  
 2} NOTE #7, SHEET E-2, INDICATESA 45
 KVA TRANSFORMER, THE SCHEMATIC /RISER,
 SHOWS 112.5 KVA TRANSFORMER, PLEASE
 CORRELATE.
  
 3} NOTE #3 INDICATES A 200 AMP
 DISCONNECT WITH 200 AMP FUSES. THE RISER
 SHOWS A 400 AMP DISCONNECT WITH 400 AMP
 FUSES (400/400) AND ALSO HAS 200 AMPS
 WRITTEN ON IT. PLEASE CORRECT.
  
 4} PLEASE INDICATE CIRCUIT NUMBERS ON
 THE EXIT AND EMERGENCY LIGHTS PER
 700.12.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2006-08-17 Cont ID  
Sent By mwennerg Date 2006-08-17 Time 14:33 Rev Time 0.00
Received By mwennerg Date 2006-08-17 Time 14:32 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2006-06-08 Cont ID  
Sent By mwennerg Date 2006-06-08 Time 10:52 Rev Time 0.00
Received By mwennerg Date 2006-06-08 Time 10:52 Sent To  
Notes
2006-06-08 00:00:00LIFE SAFETY SHALL COMPLY WITH NFPA 101,
 2003 EDITION.

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2006-08-21 Cont ID  
Sent By adarroug Date 2006-08-21 Time 10:12 Rev Time 0.00
Received By adarroug Date 2006-08-21 Time 10:12 Sent To M
Notes
2006-08-21 00:00:00TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2006-08-21 Cont ID  
Sent By adarroug Date 2006-08-21 Time 10:06 Rev Time 0.00
Received By adarroug Date 2006-08-21 Time 10:06 Sent To E
Notes
2006-08-21 00:00:00TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-08-05 Cont ID  
Sent By dpalmer Date 2006-08-05 Time 13:01 Rev Time 0.00
Received By dpalmer Date 2006-08-05 Time 13:01 Sent To  
Notes
2006-08-05 00:00:00TO BOB #15

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-07-24 Cont ID  
Sent By adarroug Date 2006-07-24 Time 10:57 Rev Time 0.00
Received By adarroug Date 2006-07-24 Time 10:57 Sent To  
Notes
2006-07-24 00:00:00WAITING FOR "BOB"-REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-07-06 Cont ID  
Sent By adarroug Date 2006-07-06 Time 11:39 Rev Time 0.00
Received By adarroug Date 2006-07-06 Time 11:39 Sent To  
Notes
2006-07-07 00:00:00TO "BOB"#10
2006-07-06 00:00:00WAITING FOR "BOB"

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-06-21 Cont ID  
Sent By adarroug Date 2006-06-21 Time 14:32 Rev Time 0.00
Received By adarroug Date 2006-06-21 Time 14:28 Sent To  
Notes
2006-06-21 00:00:00TO "BOB"#13

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-06-21 Cont ID  
Sent By adarroug Date 2006-06-08 Time 14:28 Rev Time 0.00
Received By adarroug Date 2006-05-23 Time 10:19 Sent To  
Notes
2006-05-23 00:00:00TO "BOB"#18

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2006-08-21 Cont ID  
Sent By tgordon Date 2006-08-21 Time 11:31 Rev Time 0.30
Received By tgordon Date 2006-08-21 Time 11:31 Sent To  
Notes
2006-08-21 00:00:00*** PROVISO ***
 1)SMOKE DETECTORS SHALL BE INSTALLED IN
 A/C SUPPLY SYSTEMS WITH A DESIGN
 CAPACITY GREATER THAN 2,000 CFM, IN THE
 SUPPLY AIR DUCT. 2004 FBC(M) 606.2.1OR
 UPON ACTIVATION, THE SMOKE DETECTORS
 SHALL SHUTDOWN THE AIR DISTRIBUTION
 SYSTEM. 2004 FBC(M) 606.4 .
 2) AIR DAMPERS REQUIRED AT GRILLS THAT
 DO NOT HAVE DUCT DAMPERS.
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2006-08-09 Cont ID  
Sent By tgordon Date 2006-08-09 Time 12:03 Rev Time 0.20
Received By tgordon Date 2006-08-09 Time 12:03 Sent To  
Notes
2006-08-09 00:00:00*** PROVISO ***
 1)SMOKE DETECTORS SHALL BE INSTALLED IN
 A/C SUPPLY SYSTEMS WITH A DESIGN
 CAPACITY GREATER THAN 2,000 CFM, IN THE
 SUPPLY AIR DUCT. 2004 FBC(M) 606.2.1OR
 UPON ACTIVATION, THE SMOKE DETECTORS
 SHALL SHUTDOWN THE AIR DISTRIBUTION
 SYSTEM. 2004 FBC(M) 606.4 .
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2006-05-31 Cont ID  
Sent By tgordon Date 2006-05-31 Time 12:09 Rev Time 0.30
Received By tgordon Date 2006-05-31 Time 12:09 Sent To  
Notes
2006-05-31 00:00:00*** PROVISO ***
 1)SMOKE DETECTORS SHALL BE INSTALLED
 SUPPLY SYSTEMS WITH A DESIGN CAPACITY
 GREATER THAN 2,000 CFM, IN THE SUPPLY
 AIR DUCT. 2004 FBC(M) 606.2.1OR
 UPON ACTIVATION, THE SMOKE DETECTORS
 SHALL SHUTDOWN THE AIR DISTRIBUTION
 SYSTEM. 2004 FBC(M) 606.4 .
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop P PLUMBING
Rev No 1 Status P Date 2006-06-06 Cont ID  
Sent By jleech Date 2006-06-06 Time 15:33 Rev Time 0.00
Received By jleech Date 2006-06-06 Time 15:33 Sent To  
Notes
***NONE***