| Plan Review Stops For Permit 06050625 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2006-07-11 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-07-11 |
Time |
14:07 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-07-11 |
Time |
14:07 |
Sent To |
|
|
| Notes |
| 2006-07-11 00:00:00 | RESTAMP NEW PAGES |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2006-05-24 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-05-24 |
Time |
11:56 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-05-24 |
Time |
11:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2006-09-07 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-09-07 |
Time |
17:59 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2006-09-07 |
Time |
17:24 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2006-08-03 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-08-03 |
Time |
16:16 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2006-08-03 |
Time |
14:03 |
Sent To |
|
|
| Notes |
| 2006-08-03 00:00:00 | | | | NONCOMPLIANT | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} THE 1" FEEDER TO PANEL "L2" IS TOO | | | SMALL FOR THE FEED CONDUCTORS. | | | | | | 2} PLEASE INDICATE THE LOCATION OF THE | | | OVERCURRENT PROTECTION FOR PANEL "L2", | | | AND SECONDARY PROTECTION FOR THE 30K | | | TRANSFORMER. | | | | | | 3} THE CIRCUIT NUMBERS FOR THE LIGHTS | | | AND ON THE PLAN AND THE PANEL SCHEDULE | | | DO NOT CORRELATE. | | | | | | 4} INDICATE THE LOCATIONS OF THE EXIT | | | AND EMERGENCY LIGHTING, AND LABEL SAME | | | WITH CIRCUIT NUMBERS. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-07-07 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-07-07 |
Time |
17:29 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2006-07-07 |
Time |
16:11 |
Sent To |
|
|
| Notes |
| 2006-07-07 00:00:00 | | | | | | | NONCOMPLIANT | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} THE SCOPE OF THIS WORK REQUIRES | | | ENGINEERING PER 471 FS. | | | PLEASE HAVE AN ENGINEER DESIGN THE PLAN | | | AND RESUBMIT. THE TERM "ENGINEER" | | | APPLIES TO A PERSON LICENSED UNDER | | | CHAPTER 471 FS. THE ARCHITECTDID NOT | | | SEAL PAGE E-2, WHICH IS INCEDENTAL TO | | | HIS DESIGN. HE, OR THE ENGINEER TAKING | | | RESPONSIBILITY FOR THE SERVICE DRAWING, | | | MUST SIGN AN DSEAL THIS SHEEET PR EITHER | | | 471 OR 481.FS | | | | | | 2} INCLUDE ALL EQUIPMENT (PANELS "L" AND | | | "H"), ON THE RISER. | | | | | | 3} PANEL SCHEDULE "H" DOES NOT SHOW A | | | FEED FOR THE 30 KVA TRANSFORMER. SHOW | | | PANEL "H" ON THE RISER. | | | | | | 4} PANEL "L2" IS LISTED AS "MLO", | | | THEREFORE THE TRANSFORMER FEEDING IT HAS | | | NO SECONDARY PROTECTION. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-05-17 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-05-17 |
Time |
18:37 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2006-05-17 |
Time |
18:10 |
Sent To |
|
|
| Notes |
| 2006-05-17 00:00:00 | | | | | | | THE SCOPE OF THIS WORK REQUIRES | | | ENGINEERING PER 471 FS. | | | PLEASE HAVE AN ENGINEER DESIGN THE PLAN | | | AND RESUBMIT. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2006-07-11 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2006-07-11 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2006-07-11 |
Time |
14:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2006-05-30 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-05-30 |
Time |
15:10 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-05-30 |
Time |
15:10 |
Sent To |
|
|
| Notes |
| 2006-05-30 00:00:00 | IN ADDITION TO FIRE SPRINKLER SYSTEM, | | | SEPARATE SHOP DRAWINGS AND PERMIT | | | REQUIRED FOR FIRE ALARM IF APPLICABLE | | | GREATER THAN (5) DEVICES. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-08-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-22 |
Time |
17:45 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-22 |
Time |
17:45 |
Sent To |
E |
|
| Notes |
| 2006-08-22 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-07-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-07-22 |
Time |
13:16 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-07-22 |
Time |
13:16 |
Sent To |
|
|
| Notes |
| 2006-08-01 00:00:00 | TO "BOB"#8 | | 2006-07-22 00:00:00 | WAITING FOR "BOB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-07-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-07-06 |
Time |
15:28 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-07-06 |
Time |
15:28 |
Sent To |
|
|
| Notes |
| 2006-07-07 00:00:00 | TO "BOB"#6 | | 2006-07-06 00:00:00 | WAITING FOR "BOB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-07-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-06 |
Time |
15:23 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-17 |
Time |
14:47 |
Sent To |
|
|
| Notes |
| 2006-05-17 00:00:00 | TO "BOB"#8 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2006-05-18 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-05-18 |
Time |
14:48 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2006-05-18 |
Time |
14:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2006-08-07 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-08-07 |
Time |
08:20 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-08-07 |
Time |
08:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2006-07-15 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-07-15 |
Time |
12:26 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-07-15 |
Time |
12:26 |
Sent To |
|
|
| Notes |
| 2006-07-15 00:00:00 | DENIED; | | | 1.HOSE BIBS WILL HAVE BACKFLOW | | | PROTECTION TO COMPLY WITH FBC-2004 | | | PLUMBING SECTION 608.15.4.2. | | | 2.THE EQUIPMENT DRAIN IS NOT SHOWN. IF | | | INDIRECT A FLOOR DRAIN IS REQUIRED WITH | | | AN AIR GAP, IF DIRECT SHOW ON PLANS. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-06-06 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-06-06 |
Time |
10:03 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-06-06 |
Time |
10:03 |
Sent To |
|
|
| Notes |
| 2006-06-06 00:00:00 | DENIED; | | | SUBMIT MANUFATURE'S SPECIFCATIONS FOR | | | PROC. NOT ENOUGH INFORMATION TO DO A | | | PLUMBING PLAN REVIEW. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|