| Plan Review Stops For Permit 06050590 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2007-02-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-02-27 |
Time |
15:54 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2007-02-27 |
Time |
15:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2006-09-15 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-09-15 |
Time |
11:24 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2006-09-15 |
Time |
11:24 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-06-02 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-06-02 |
Time |
09:32 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2006-06-02 |
Time |
09:32 |
Sent To |
|
|
| Notes |
| 2006-06-02 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 06050590 | | | ADD: 250 S AUSTRALIAN AVE | | | CONT: PROTON ELECTRIC | | | TEL: (561)543-6671 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) GENERATOR SLAB & ANCHOR REQUIREMENT | | | PLEASE PROVIDE SIZE OF GENERATOR(WXL), | | | PLUS PROVIDE PLANS WITH THE INFORMATION | | | DEPICTING HOLD DOWN BRACKETS, TYPE OF | | | FASTENER, AND THE MINIMUM EDGE DISTANCE | | | THE DEVICE REQUIRES WITHOUT LOAD | | | REDUCTION. | | | SECOND, PROVIDE INFORMATION ON THE | | | SLAB, THICKNESS, WIDTH AND LENGTH, IF | | | WIREMESH, FIBER MESH OR IF STEEL REBAR | | | WILL BEUSED. | | | THE NEW SLAB AND HOLD DOWN DETAILS: | | | 104.2.1* ALL INFORMATION, DRAWINGS, | | | SPECIFICATIONS AND ACCOMPANYING DATA | | | SHALL BEAR THE NAME AND SIGNATURE OF THE | | | PERSON RESPONSIBLE FOR THE DESIGN. | | | | | | 2) PLANS DO NOT INDICATE LOCATION OF | | | GENERATOR AND RELATIONSHIP TO THE REST | | | OF THE STRUCTURE OR STRUCTURES WITHIN | | | 10' OF GENERATOR. | | | PROVIDE PLANS ENOUGH TO VERIFY LOCATION | | | OF GENERATOR VERSES BUILDING OPENINGS | | | WINDOWS, DOORS OR SOFFIT TYPE VENTS, | | | ETC. | | | | | | MECHANICAL CODE | | | 804.3.4 HORIZONTAL TERMINATIONS. | | | HORIZONTAL TERMINATIONS SHALL COMPLY | | | WITH THE FOLLOWING REQUIREMENTS: | | | 1.WHERE LOCATED ADJACENT TO | | | WALKWAYS, THE TERMINATION OF MECHANICAL | | | DRAFT SYSTEMS SHALL BE NOT LESS THAN 7 | | | FEET (2134 MM) ABOVE THE LEVEL OF THE | | | WALKWAY. | | | 2.VENTS SHALL TERMINATE AT LEAST 3 | | | FEET (914 MM) ABOVE ANY FORCED AIR INLET | | | LOCATED WITHIN 10 FEET (3048 MM). | | | 3.THE VENT SYSTEM SHALL TERMINATE | | | AT LEAST 4 FEET (1219 MM) BELOW, 4 FEET | | | (1219 MM) HORIZONTALLY FROM OR 1 FOOT | | | (305 MM) ABOVE ANY DOOR, WINDOW OR | | | GRAVITY AIR INLET INTO THE BUILDING. | | | 4.THE VENT TERMINATION POINT SHALL | | | NOT BE LOCATED CLOSER THAN 3 FEET (914 | | | MM) TO AN INTERIOR CORNER FORMED BY TWO | | | WALLS PERPENDICULAR TO EACH OTHER. | | | 5.THE VENT TERMINATION SHALL NOT BE | | | MOUNTED DIRECTLY ABOVE OR WITHIN 3 FEET | | | (914 MM) HORIZONTALLY FROM AN OIL TANK | | | VENT OR GAS METER. | | | 6.THE BOTTOM OF THE VENT | | | TERMINATION SHALL BE LOCATED AT LEAST 12 | | | INCHES (305 MM) ABOVE FINISHED GRADE. | | | | | | 804.3.5 VERTICAL TERMINATIONS. | | | VERTICAL TERMINATIONS SHALL COMPLY WITH | | | THE FOLLOWING REQUIREMENTS: | | | 1.WHERE LOCATED ADJACENT TO | | | WALKWAYS, THE TERMINATION OF MECHANICAL | | | DRAFT SYSTEMS SHALL BE NOT LESS THAN 7 | | | FEET (2134 MM) ABOVE THE LEVEL OF THE | | | WALKWAY. | | | 2.VENTS SHALL TERMINATE AT LEAST 3 | | | FEET (914 MM) ABOVE ANY FORCED AIR INLET | | | LOCATED WITHIN 10 FEET (3048 MM). | | | 3.WHERE THE VENT TERMINATION IS | | | LOCATED BELOW AN ADJACENT ROOF | | | STRUCTURE, THE TERMINATION POINT SHALL | | | BE LOCATED AT LEAST 3 FEET (914 MM) FROM | | | SUCH STRUCTURE. | | | 4.THE VENT SHALL TERMINATE AT LEAST | | | 4 FEET (1219 MM) BELOW, 4 FEET (1219 MM) | | | HORIZONTALLY FROM, OR 1 FOOT (305 MM) | | | ABOVE ANY DOOR, WINDOW OR GRAVITY AIR | | | INLET FOR THE BUILDING. | | | 5.A VENT CAP SHALL BE INSTALLED TO | | | PREVENT RAIN FROM ENTERING THE VENT | | | SYSTEM. | | | 6.THE VENT TERMINATION SHALL BE | | | LOCATED AT LEAST 3 FEET (914 MM) | | | HORIZONTALLY FROM ANY PORTION OF THE | | | ROOF STRUCTURE. | | | | | | 501.2 OUTDOOR DISCHARGE. | | | | | | THE AIR REMOVED BY EVERY MECHANICAL | | | EXHAUST SYSTEM SHALL BE DISCHARGED | | | OUTDOORS AT A POINT WHERE IT WILL NOT | | | CAUSE A NUISANCE AND FROM WHICH IT | | | CANNOT AGAIN BE READILY DRAWN IN BY A | | | VENTILATING SYSTEM. AIR SHALL NOT BE | | | EXHAUSTED INTO AN ATTIC OR CRAWL SPACE | | | | | | 401.5 OPENING LOCATION. | | | OUTDOOR AIR EXHAUST AND INTAKE OPENINGS | | | SHALL BE LOCATED A MINIMUM OF 10 FEET | | | (3048 MM) FROM LOT LINES OR BUILDINGS ON | | | THE SAME LOT. WHERE OPENINGS FRONT ON A | | | STREET OR PUBLIC WAY, THE DISTANCE SHALL | | | BE MEASURED TO THE CENTERLINE OF THE | | | STREET OR PUBLIC WAY. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2007-02-06 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-02-06 |
Time |
12:55 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-02-06 |
Time |
11:56 |
Sent To |
|
|
| Notes |
| 2007-02-06 12:56:27 | ELEC OK, | | | | | | 3RD SET FO MECH AND BLDG SHEETS ARE PHOTO-COPIES OF | | | SIGNED AND SEALED PLANS. | | | THE ELECTRICAL SHEETS IN THE THIRD SET ARE ORIGINAL. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2006-11-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-11-17 |
Time |
15:15 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-11-17 |
Time |
14:53 |
Sent To |
|
|
| Notes |
| 2006-11-17 15:16:21 | **** UNSAT 3RD REVIEW **** | | | | | | ***PLEASE SEE SOME NOTE FROM PREVIOUS REVIEW(S). | | | | | | 1) NOTE:PLEASE SUBMIT PLANS SPECS/MANUFACTURE CUT | | | SHEETS INTO THREE COMPLETE SETS, AS THREE SETS OF | | | ELECTRICAL PLANS ARE BEING SUBMITTED, PLEASE ALSO | | | SUBMIT THREE SETS OF ALL FOR STAMPING. | | | PLEASE SUBMIT ALL PLANS IN A NEAT AND ORDERLY FASHION. | | | | | | ONLY ONE SET OF EACH OF THE OLD/VOIDED SHEETS SHOULD BE | | | SUBMITTED FOR REFERENCE. THESE SHALL BE LABELED | | | "VOIDED/OLD" AND SHOULD BE PLACED TOGETHER SEPARATE | | | FROM NEW SETS. | | | ANY COMMENT RESPONSE LETTERS FRO DESIGN PROFESSIONAL | | | SHALL BE KEPT SEPARATELY. | | | THIS WAS REQUESTED ON PREVIOUS REVIEW. | | | | | | 2) NOTE: PLEASE SEE AS STATED ON PREVIOUS REVIEWS, THE | | | ELECTRICAL CONTRACTOR HAS NOT SIGNED ON THE ELECTRICAL | | | LINE OF PERMIT APPLICATION FOR THE ELECTRICAL PERMIT AS | | | PART OF THIS PACKAGE. IF THIS ELECTRICAL CONTRACTOR IS | | | NOT DOING THE ELECTRICAL INSTALLATION AS SUBMITTED | | | WHICH IS HIGHLY UNLIKELY, THEN PLEASE KNOW SEPARATE | | | PERMIT APPLICATION WILL BE REQUIRED WITH SEPARATE FEES. | | | THIS IS THE LAST NOTICE WHICH WILL BE GIVEN TO THIS. | | | | | | 3) NOTE: PLEASE SEE FLOOR /SITE PLANS DO NOT CORRELATE | | | WITH RISER DIAGRAM SUBMITTED. PLEASE SEE FIRST FLOOR | | | ELECTRICAL ROOM IS NOT SHOWN ON E-2, AND THE FEEDERS DO | | | NOT SHOW THESE GOING TO ANY DISCONNECTING MEANS AT THIS | | | BUILDING WHICH IS PARTIALLY SHOWN ON RISER. | | | 225.31-225.39. | | | PLEASE SEE PREVIOUS NOTES. | | | | | | 4) NOTE: PLEASE SEE PREVIOUS NOTES FOR DETAILS WHICH IS | | | REQUIRED PER NFPA-110 PLEASE SEE SECTIONS BELOW AS | | | PLANS DO NOT PROVIDE ENOUGH INFORMATION FOR SEPARATION, | | | ISOLATION, ETC. FROM THE STRUCTURAL ELEMENTS OF THE | | | BUILDING. | | | PLEASE SEE NFPA-110 2002 7.3, .4, .5, .6, .7 ETC. | | | THIS WAS PAST BY THE BUILDING REVIEWER , HOWEVER IS | | | STILL REQUIRED. | | | | | | ** ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | **PLEASE SUBMIT THE ABOVE INFORMATION FOR REVIEW. | | | **IF THERE ARE ANY QUESTIONS, COMMENTSOR IF ANY OF | | | THE NOTES TYPEDWHICH ARE UNCLEAR IN ANY WAY, PLEASE | | | DO NOT HESITATEIN CONTACTING THIS REVIEWER. | | | | | | | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-08-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-08-16 |
Time |
18:31 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-08-16 |
Time |
17:46 |
Sent To |
|
|
| Notes |
| 2006-08-16 00:00:00 | *** UNSAT 2ND REVIEW *** | | | | | | 1) NOTE: PLEASE SEE MAINS AND | | | DISCONNECTING MEANS FOR FEEDERES AND | | | SEC'S SHALL BE GROUPED. THE MAINS ARE | | | NOT GROUPED AND HAVING A BREAKER ON THE | | | GEN IN THE GARAGE OR THE MAIN IN SB8 IS | | | NOT PERMITTED. | | | PLEASE SEE 225.31-225.39, 230.72 ETC. | | | PLEASE KNOW THAT A DISCONNECTING MEANS | | | FOR THE FEEDERS FROM THE GEN WILL BE | | | REQUIRED IN CLOSE PROXIMITY TO THE | | | EXISTING MAINS/DISCONNECTS. | | | PLEASE ALSO KNOW THAT THE ATS IS NOT | | | PERMITTED IN THE MECHANICAL EQUIPMENT | | | ROOM AND SHALL BE LOCATED IN THE | | | ELECTRICAL ROOM WITH OTHER ELECTRICAL | | | EQUIPMENT WHICH IS IS BEIGN FED FROM AND | | | WHICH IT IS FEEDING. | | | | | | | | | 2) NOTE: PLEASE SEE REVIEW COMMENTS FROM | | | OTHER TRADES AS THE LOCATION OF THE | | | GENERATOR IN THE PARKING GARAGE DOES NOT | | | PROVIDE ENOUGH INFORMATION FOR | | | SEPARATION, ISOLATION, ETC. | | | PLEASE SEE NFPA-110 2002 7.3,.4,.5,.6,.7 | | | ETC. | | | | | | 3) NOTE: PLEASE KNOW THAT ONLY TWO SETS | | | OF ELECTRICAL PLANS ARE REQUIRED, | | | HOWEVER THREE SETS ARE BEING SUBMITTED. | | | IF SUBMITTING THREE FOR STAMPING, THEN | | | PLEASE BE SURE THE THIRD SET IS SIGNED, | | | DATED AND SEALED. | | | FS 471.025, FAC 61G15-23.002 | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-06-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-11 |
Time |
09:20 |
Rev Time |
|
| Received By |
dpalmer |
Date |
2006-06-11 |
Time |
08:30 |
Sent To |
|
|
| Notes |
| 2006-06-11 00:00:00 | ********** UNSAT ************* | | | | | | ** PLEASE KNOW BESIDES THE BELOW | | | COMMENTS, PLANS ARE NOT COMPLETE AT THIS | | | TIME FOR COMPLETE REVIEW. | | | | | | | | | 1) NOTE: ATTENTION CONTRACTOR, IF PROTON | | | ELECTRICAL IS ALSO DOING THE ELECTRICAL | | | INSTALLATION FOR THE CONNECTIONS ON THE | | | GENERATOR, THEN PLEASE SIGN ON THE | | | ELECTRICAL LINE ON PERMIT APPLICATION SO | | | AN ELECTRICAL PERMIT CAN BE ESTABLISHED. | | | THIS WAS NOT | | | | | | 2) NOTE: PLEASE SUBMIT SPECS FOR FUEL | | | TANK. PLEASE SEE PLANS MUST INCLUDED | | | LOCATION, VENTILATION, FIRE RATINGS ETC | | | . | | | PLEASE SEE NOTE #5 BELOW, IF THE GEN | | | FEEDS ANY LEGALLY REQUIRED BACK UP | | | LTS/SYSTEMS, THE AMOUNT OF FUEL, AND RUN | | | TIMES SHALL BE CLEARLY INDICATED ON | | | PLANS. | | | PLEASE KNOW THERE IS NOTHING ON PLANS | | | FOR INSTALLATIONOF GEN, FUEL, LOCATION | | | ETC. | | | PLEASE SEE COMMENTS FROM OTHER TRADES | | | WHICH WILL AFFECT PLANS SUBMITTED. | | | PLEASE BE SURE ALL TANK SPECS CONTAIN | | | LISTING BY A NRTL. | | | 215.5 | | | | | | 3) NOTE: PLEASE SUBMIT A COMPLETEPLAN | | | SHOWING THE LAYOUT FOR THE GENERATOR. | | | PLEASE SEE THAT NO MEANS OF DISCOONECTS | | | ARE BEING SHOWN FOR GROUPING OF MAINS IN | | | THE BUILDING. | | | PLEASE SHOW THE LOCATION OF ALL THE | | | EXISTING GENERATORS FEEDING THIS | | | BUILDING THE MEANS OF DICONNECT LOCAITON | | | FOR ALL. | | | 230.72, 225.31-225.39, 230.2 | | | | | | 4) NOTE: PLEASE SEE THAT ALL SPECS | | | SUBMITTED FOR GEN, ATS ETC SHALL CLEARLY | | | BE HIGHLIGHTED FOR EACH UNIT EQUIPMENT | | | BEING USED ON THIS JOBSITE. | | | 215.5 | | | | | | 5) NOTE: PLEASE VERIFY IF THIS GENERATOR | | | WILL BE FEEDING ANY OF THE REQUIRED BACK | | | UP POWER FROM LIGHTING ETC. | | | PLEASE NOTE IF ALL LTS ARE BATTERY BACK | | | UP, OR ARE THEY FED FROM A LEGALLY | | | REQUIRED BACK UP SYSTEM NOW. | | | PLEASE SEE SYSTEM INSTALLATION | | | REQUIREMENTS PER 700,701, NFPA-110 ETC | | | | | | | | | 6) NOTE: PLEASE SEE PLANS INDICATE TWO | | | TRANSFORMERS BEING FED, YET PANEL SB8 | | | DOES NOT CORRELATE. | | | 215.5 | | | | | | 7) NOTE: PLEASE PLACE NOTES ON PLANS FOR | | | ALL SIGNAGE WHICH WILL BE REQUIRED. | | | 230.2E,702.8,701.9 ETC. | | | PLEASE KNOW, THE LOCATIONS OF SUCH | | | DISCONNECTS AND SYSTEMS HAVE NOT BEEN | | | APPROVED AT THIS TIME. | | | | | | 8) NOTE: PLEASE INDICATE THE OCP AT | | | GENERATOR. | | | 215.5 | | | | | | 9) NOTE: PLEASE SEE MULTIPLE PANELS ON | | | RISER WITH THE SAME IDENTIFICATION?? | | | | | | 10) NOTE: PLEASE SEE THAT ALL CONTINUOUS | | | LOADS SHALL BE SHOWN AT 125%. | | | 215.3,230.42 ETC | | | | | | 11) NOTE: PLEASE SEE MAX HEAT LOADS | | | SHALL BE FIGURED FOR THE AHU'S OR LOAD | | | SHEDDING IS PERMITTED. PLEASE PROVIDE A | | | COMPLETE DETAIL FOR LOAD SHEDDING IF | | | THIS OPTION IS TAKEN. | | | THE WIRING SCHEMATIC WILL BE REQUIRED ON | | | PLANS. | | | 702.5 ETC | | | | | | 12) NOTE: PLEASE SEE GEN ANNUNCIATOR | | | PANEL, CONTROLS,STATUS INDICATORS SHALL | | | ALSO BE LOCATED IN THE EXISTING FIRE | | | COMMAND ROOM WITH SIGNAGE AS REQUIRED. | | | NFPA-72, NFPA-101, NFPA-110 | | | | | | 13) NOTE: PLEASE KNOW, A FUEL TYPE | | | PERMIT MAY ALSO BE REQUIRED. SEE MECH | | | REVIEW. | | | | | | 14) NOTE: PLEASE SEE MISSING EQUIPMENT | | | GROUNDING CONDUCTORS. | | | 250.110,250.122,250.6,250.24. | | | PLEASE SEE NONE ARE BEING SHOWN AT THIS | | | TIME. PLEASE KNOW, IF USING ALL METAL | | | CONDUITS, THEN CONNECTORS ALL SHALL BE | | | LISTED FOR "EQUIPMENT GROUNDING". | | | STANDARD CONNECTORS ARE NO PERMITTED | | | UNLESS LISTED AS NOTED.OR | | | PLEASE INDICATE THE EQUIPMENT GROUNDING | | | CONDUCTOR SIZED PER 250.122 | | | | | | ** PLEASE SEE COMMENTS FROM OTHER TRADES | | | WHICH WILL AFFECT THE PLANS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2007-03-07 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-03-07 |
Time |
14:03 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-03-07 |
Time |
13:53 |
Sent To |
|
|
| Notes |
| 2007-03-07 14:03:36 | *****APPROVED***** | | | | | | | | | ALL COMMENTS FROM PREVIOUS FIRE PLAN REVIEWS HAVE BEEN | | | ADDRESSED.PLAN SHEET E3 WAS STAMPED, INITIALED, AND | | | DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
F |
Date |
2006-12-22 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2006-12-22 |
Time |
11:03 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2006-12-22 |
Time |
11:03 |
Sent To |
|
|
| Notes |
| 2006-12-22 11:07:29 | *****DENIED***** | | | | | | | | | | | | PLEASE REVIEW THE PREVIOUS TWO FIRE PLAN REVIEWS FOR | | | REFERENCE.TO EXPEDITE THE PLAN REVIEW PROCESS, | | | INCLUDE A RESPONSE LETTER INDICATING HOW/WHERE EACH | | | ITEM WAS ADDRESSED. | | | | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2006-09-15 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-09-15 |
Time |
11:08 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-09-15 |
Time |
11:08 |
Sent To |
|
|
| Notes |
| 2006-09-15 00:00:00 | ***DENIED*** | | | | | | PLEASE BE ADVISED THAT NO RESPONSE | | | LETTER WAS SUBMITTED FOR FIRST FIRE | | | REVIEW COMMENTS. IT WOULD APPEAR THAT | | | SOME INFORMATION IS NOW SHOWING HOWEVER | | | PLEASE RESPOND TO THE FOLLOWING: | | | | | | 1) NOTE (3) WILL CONTROL PANELS BE | | | PROVIDED IN THE FIRE COMMAND ROOM TO | | | ADVISE STATUS OF THE SYSTEM? | | | | | | 2) WHAT OTHER EQUIPMENT WILL BE | | | CONTAINED WITHIN THE ROOM WHERE THE | | | GENERATOR IS PLANNED? | | | | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2006-06-16 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2006-06-16 |
Time |
14:18 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2006-06-16 |
Time |
14:04 |
Sent To |
|
|
| Notes |
| 2006-06-16 00:00:00 | 1. THE PLANS INDICATE THAT A NEW | | | GENERATOR IS PLANNED FOR THE SECOND | | | FLOOR GENERATOR ROOM OF THE PARKING | | | GARAGE. INFORMATION INDICATES THAT THE | | | GENERATOR IS TO BE SUPPLIED BY NATURAL | | | GAS. NO DETAILS PROVIDED ON WHERE THE | | | PROPOSED INSTALLATION ROOM IS LOCATED | | | WITHIN THE GARAGE. | | | | | | 2. NO DETAILS PROVIDED WITH REGARDS TO | | | VENTING OF THE GENERATOR WHILE IT IS | | | RUNNING. THE TERMINATION POINT OF THE | | | EXHAUST IS TO BE SHOWN SO A BACK FEED OF | | | DANGEROUS FUMES DOES NOT OCCUR. | | | SOMETIMES ARCHITECTURAL ELEMENTS OF A | | | BUILDING CAN CAUSE THIS TO OCCUR. | | | | | | 3. WILL CONTROL PANELS BE PROVIDED IN | | | THE FIRE COMMAND ROOM TO ADVISE STATUS | | | OF THE SYSTEM. | | | | | | 4. WHAT OTHER EQUIPMENT WILL BE | | | CONTAINED WITHIN THE ROOM WHERE THE | | | GENERATOR IS PLANNED. | | | | | | 5. MORE DETAILS ARE NEEDED FOR THE PLAN | | | REVIEW PROCESS. | | | | | | MIKE CARSILLO, CHIEF FIRE PREVENTION | | | OFFICER | | | 804-4709 |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
5 |
Status |
P |
Date |
2007-03-30 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-03-30 |
Time |
16:50 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-03-30 |
Time |
16:50 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
4 |
Status |
F |
Date |
2007-02-21 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-02-21 |
Time |
08:02 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-02-21 |
Time |
08:02 |
Sent To |
|
|
| Notes |
| 2007-02-21 08:33:10 | DENIED | | | REFERENCE: FBC-2004 FUEL GAS | | | | | | FROM PREVIOUS REVIEWS: | | | | | | THE FOLLOWING INFORMATION IS REQUIRED | | | FOR THE SEPARATE GAS PERMIT: | | | | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2004 | | | FUEL GAS CODE. | | | ****OK | | | | | | 2. SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE BEING USED. | | | ****OK | | | | | | 3. BTU LOAD OF EACH APPLIANCE AND THE | | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | | THE FBC-2004 FUEL GAS CODE SECS. 401.8 | | | THRU 402.6.1 AND TABLES 402.4(1) THRU | | | 402.4(33). | | | ****RESPONSE NOTED, BUT THE BTU INFORMATION SUBMITTED | | | IS CONFLICTING FROM ONE PAGE TO THE OTHER. THE NEXT TO | | | LAST SHEET INDICATES THE BTU LOAD TO BE 905,000 BTU'S, | | | BUT THE FINAL PAGE INDICATES FUEL CONSUMPTION TO BE | | | 4200 CFH, (4,536,000 BTU'S). PLEASE CLARIFY AS THIS IS | | | A LARGE DISCREPENCY. | | | | | | 4. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES A.3.1(4). | | | ****OK | | | | | | 5. SUBMIT CALCULATIONS FOR COMBUSTION | | | AIR (IF APPLICABLE) PER FBC-2004 FUEL | | | GAS CODE SECTION 304. | | | ****NOT SUBMITTED. | | | | | | 6. INDICATE THE DELIVERY PRESSURE (PSI) | | | PER FBC-2004 FUEL GAS CODE SEC. 402.2. | | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. | | | ****OK | | | | | | 7. SUBMIT A DETAIL SHOWING THE TYPE, | | | LOCATION, SIZE AND TERMINATION OF THE | | | GAS VENTS PER FBC-2004 FUEL GAS CODE | | | SECS. 502 THRU 505. | | | ****OK | | | | | | 8. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2004 FUEL GAS CODE SEC 402.2. | | | MANUFACTURES INSTALLATION INSTRUCTIONS | | | REQUIRE TO SHOW MINIMUM CLEARANCES FROM | | | ALL STRUCTURES. | | | ****OK | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
F |
Date |
2007-01-06 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-01-06 |
Time |
18:06 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-01-06 |
Time |
18:06 |
Sent To |
|
|
| Notes |
| 2007-01-06 18:06:59 | DENIED | | | REFERENCE: FBC-2004 FUEL GAS | | | | | | THE FOLLOWING INFORMATION IS REQUIRED | | | FOR THE SEPARATE GAS PERMIT: | | | | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2004 | | | FUEL GAS CODE. | | | | | | 2. SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE BEING USED. | | | | | | 3. BTU LOAD OF EACH APPLIANCE AND THE | | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | | THE FBC-2004 FUEL GAS CODE SECS. 401.8 | | | THRU 402.6.1 AND TABLES 402.4(1) THRU | | | 402.4(33). | | | | | | 4. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES A.3.1(4). | | | | | | 5. SUBMIT CALCULATIONS FOR COMBUSTION | | | AIR (IF APPLICABLE) PER FBC-2004 FUEL | | | GAS CODE SECTION 304. | | | | | | 6. INDICATE THE DELIVERY PRESSURE (PSI) | | | PER FBC-2004 FUEL GAS CODE SEC. 402.2. | | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. | | | | | | 7. SUBMIT A DETAIL SHOWING THE TYPE, | | | LOCATION, SIZE AND TERMINATION OF THE | | | GAS VENTS PER FBC-2004 FUEL GAS CODE | | | SECS. 502 THRU 505. | | | | | | 8. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2004 FUEL GAS CODE SEC 402.2. | | | MANUFACTURES INSTALLATION INSTRUCTIONS | | | REQUIRE TO SHOW MINIMUM CLEARANCES FROM | | | ALL STRUCTURES. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2007-01-06 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-08-25 |
Time |
07:42 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-08-25 |
Time |
07:42 |
Sent To |
|
|
| Notes |
| 2006-08-25 00:00:00 | DENIED | | | REFERENCE: FBC-2004 FUEL GAS | | | | | | THE FOLLOWING INFORMATION IS REQUIRED | | | FOR THE SEPARATE GAS PERMIT: | | | | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2004 | | | FUEL GAS CODE. | | | | | | 2. SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE BEING USED. | | | | | | 3. BTU LOAD OF EACH APPLIANCE AND THE | | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | | THE FBC-2004 FUEL GAS CODE SECS. 401.8 | | | THRU 402.6.1 AND TABLES 402.4(1) THRU | | | 402.4(33). | | | | | | 4. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES A.3.1(4). | | | | | | 5. SUBMIT CALCULATIONS FOR COMBUSTION | | | AIR (IF APPLICABLE) PER FBC-2004 FUEL | | | GAS CODE SECTION 304. | | | | | | 6. INDICATE THE DELIVERY PRESSURE (PSI) | | | PER FBC-2004 FUEL GAS CODE SEC. 402.2. | | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. | | | | | | 7. SUBMIT A DETAIL SHOWING THE TYPE, | | | LOCATION, SIZE AND TERMINATION OF THE | | | GAS VENTS PER FBC-2004 FUEL GAS CODE | | | SECS. 502 THRU 505. | | | | | | 8. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2004 FUEL GAS CODE SEC 402.2. | | | MANUFACTURES INSTALLATION INSTRUCTIONS | | | REQUIRE TO SHOW MINIMUM CLEARANCES FROM | | | ALL STRUCTURES. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2006-06-27 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-06-27 |
Time |
11:17 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-06-27 |
Time |
11:17 |
Sent To |
|
|
| Notes |
| 2006-06-27 00:00:00 | DENIED | | | REFERENCE: FBC-2004 FUEL GAS | | | | | | THE FOLLOWING INFORMATION IS REQUIRED | | | FOR THE SEPARATE GAS PERMIT: | | | | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2004 | | | FUEL GAS CODE. | | | | | | 2. SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE BEING USED. | | | | | | 3. BTU LOAD OF EACH APPLIANCE AND THE | | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | | THE FBC-2004 FUEL GAS CODE SECS. 401.8 | | | THRU 402.6.1 AND TABLES 402.4(1) THRU | | | 402.4(33). | | | | | | 4. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES A.3.1(4). | | | | | | 5. SUBMIT CALCULATIONS FOR COMBUSTION | | | AIR (IF APPLICABLE) PER FBC-2004 FUEL | | | GAS CODE SECTION 304. | | | | | | 6. INDICATE THE DELIVERY PRESSURE (PSI) | | | PER FBC-2004 FUEL GAS CODE SEC. 402.2. | | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. | | | | | | 7. SUBMIT A DETAIL SHOWING THE TYPE, | | | LOCATION, SIZE AND TERMINATION OF THE | | | GAS VENTS PER FBC-2004 FUEL GAS CODE | | | SECS. 502 THRU 505. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2007-05-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-05-16 |
Time |
09:05 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-16 |
Time |
09:05 |
Sent To |
M |
|
| Notes |
| 2007-05-16 09:05:22 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2007-03-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-14 |
Time |
15:26 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-14 |
Time |
15:26 |
Sent To |
G |
|
| Notes |
| 2007-03-14 15:26:36 | TO "G" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-01-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-01-25 |
Time |
11:01 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-01-25 |
Time |
11:01 |
Sent To |
|
|
| Notes |
| 2007-02-06 10:55:41 | TO "COMM" BD#15 | | 2007-01-25 11:01:35 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-11-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-11-12 |
Time |
13:30 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-11-12 |
Time |
13:30 |
Sent To |
|
|
| Notes |
| 2006-11-14 10:14:26 | TO "COMM" BD#46 | | 2006-11-12 13:30:24 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-08-04 |
|
|
Cont ID |
|
| Sent By |
mmiller |
Date |
2006-08-04 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-04 |
Time |
13:45 |
Sent To |
|
|
| Notes |
| 2006-08-12 00:00:00 | TO "COMM" BD#27 | | 2006-08-07 00:00:00 | 8/7/06-WAITING FOR "COMM" BD | | 2006-08-04 00:00:00 | SENT "DP" DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-06-27 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-06-27 |
Time |
11:18 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-05-17 |
Time |
15:31 |
Sent To |
|
|
| Notes |
| 2006-06-01 00:00:00 | TO "COMM"BD#23 | | 2006-05-17 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2007-05-30 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2007-05-30 |
Time |
10:38 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2007-05-30 |
Time |
10:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2007-04-02 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2007-04-02 |
Time |
09:42 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2007-04-02 |
Time |
09:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2007-02-24 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2007-02-24 |
Time |
08:59 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2007-02-24 |
Time |
08:59 |
Sent To |
|
|
| Notes |
| 2007-02-24 09:01:44 | NATURAL GAS MECHANICAL NOT REQUIRED | | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2006-06-24 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2006-06-24 |
Time |
10:37 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2006-06-24 |
Time |
10:33 |
Sent To |
|
|
| Notes |
| 2006-06-24 00:00:00 | NATURAL GAS MECHANICAL NOT REQUIRED. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2006-06-27 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-06-27 |
Time |
10:40 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-06-27 |
Time |
10:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
N |
Date |
2006-11-16 |
|
|
Cont ID |
|
| Sent By |
kdfreema |
Date |
2006-11-16 |
Time |
08:14 |
Rev Time |
0.00 |
| Received By |
kdfreema |
Date |
2006-11-16 |
Time |
08:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
N |
Date |
2006-08-23 |
|
|
Cont ID |
|
| Sent By |
mflis |
Date |
2006-08-23 |
Time |
10:22 |
Rev Time |
0.00 |
| Received By |
mflis |
Date |
2006-08-23 |
Time |
10:22 |
Sent To |
|
|
| Notes |
| 2006-08-23 00:00:00 | NO CHANGES TO PARKING LAYOUT OR EXTERIOR | | | BUILDING. ANY EXPOSED CONDUIT SHOULD BE | | | PAINTED TO MATCH EXISTING BUILDING. | | | ZONING REVIEW NOT REQUIRED. | | | | | | MATTHEW FLIS |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2006-06-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-06-26 |
Time |
18:58 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|