| Plan Review Stops For Permit 06050526 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2007-01-12 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2007-01-12 |
Time |
11:48 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2007-01-12 |
Time |
11:48 |
Sent To |
|
|
| Notes |
| 2007-01-12 11:49:00 | REVISION #2 OK LM |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2006-10-06 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2006-10-06 |
Time |
14:22 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2006-10-06 |
Time |
14:22 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-09-26 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2006-09-26 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2006-09-26 |
Time |
15:50 |
Sent To |
M |
|
| Notes |
| 2006-09-26 00:00:00 | | | | | | | DENIED | | | | | | 1) NO PRODUCT APPROVALS WERE SUBMITTED | | | FOR THE SECTIONAL GARAGE DOORS #'S 103, | | | 104 AND 106 | | | | | | 2) CECO SWINGING DOORS ARE HOLLOW METAL | | | FOR #'S 100 AND 101 AND DRAWING STATES | | | WOOD PLEASE CORRECT | | | | | | 3) DRAWINGS SPECIFY IMPACT RESISTANT | | | WINDOWS AND THE PRODUCT APPROVALS THAT | | | ARE SUBMITTED ARE FOR NON IMPACT, PLEASE | | | CORRECT (FLORIDA COVER IS THE SAME) | | | | | | 4) PROVIDE TYPE OF ROOF COVERING AND | | | PRODUCT APPROVAL FOR BREEZEWAY | | | | | | 5) ONLY ONE COPY OF ROOFING PRODUCT | | | APPROVAL WAS SUBMITTED. PLEASE CONFIRM | | | THIS TYPE OF ROOF COVERING IS TO BE USED | | | AS IT IS FASTENED THROUGH THE MEMBRANE | | | AND INSULATION INTO DECK. THE RAS 117 | | | CALCULATIONS DO NOT MEET THE REQUIRED | | | AMOUNT OF FASTENERS (SEE PAGE 5 OF NOA) | | | FASTENERS AND PLATES ARE MECHANICALLY | | | ATTACHED SPACED AT 6" ON CENTER TO MEET | | | THE -45 PSF | | | | | | 6) PLEASE REMOVE ANY ROOM DESIGNATIONS | | | AND WALLS FROM DRAWINGS AS THE CITY CODE | | | STATES THAT THE GARAGE FLOOR IS EXEMPT | | | FROM BEING 6" ABOVE FLOOD ELEVATION WHEN | | | ITS SOLE USE IS FOR VEHICLE PARKING | | | | | | 7) PLEASE REMOVE ALL NON USED PRODUCT | | | APPROVALS FROM THE SUBMITTAL. ONLY RE | | | SUBMIT 2 COMPLETE SETS OF PRODUCT | | | APPROVALS AND DRAWINGS ALONG WITH THE | | | OLD PAGES THAT ARE CHANGED AND THE OLD | | | PAGES WITH THE IMPACT FEE STAMPS | | | | | | 8) PER 713.13(2) F.S. | | | IF THE IMPROVEMENT DESCRIBED IN THE NOC | | | HAS NOT COMMENCED WITHIN 90 DAYS OF | | | RECORDING THE NOTICE IS VOID | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-06-28 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2006-06-28 |
Time |
15:06 |
Rev Time |
2.00 |
| Received By |
amorse |
Date |
2006-06-28 |
Time |
15:06 |
Sent To |
PC |
|
| Notes |
| 2006-06-28 00:00:00 | | | | | | | DENIED | | | | | | 1) A CERTIFICATE OF AUTHORIZATION SHALL | | | BE REQUIRED FOR A CORPORATION, LIMITED | | | LIABILITY COMPANY, OR PARTNERSHIP, | | | OFFERING ARCHITECTURAL SERVICES TO THE | | | PUBLIC JOINTLY OR SEPARATELY. | | | PER 481.219(2) F.S. | | | | | | 2) WIND DESIGN CRITERIA SHALL CARRY | | | RVISED REFERENCE STANDARD 7-02 | | | | | | 3) THE STATE OF FLORIDA REQUIRES | | | COLLECTION OF A RADON SURCHARGE ON ALL | | | NEW CONSTRUCTION COMPUTED ON UNDER ROOF | | | FLOOR SPACE PER 10D-91 FAC | | | | | | 4) THE SURVEY FOR THE PROPOSED ADDITION | | | SHOWS THE NGVD BASE FLOOD ELEVATION AS | | | 7' THE CITY CODE REQUIRES THE FLOOR | | | ELEVATION TO BE 6" ABOVE THIS LEVEL. PER | | | CITY CODES THE EXISTING STRUCTURE MUST | | | ALSO MEET THIS REQUIREMENT WHEN THEIR IS | | | SUBSTANTIAL IMPROVEMENT (MORE THAN 50% | | | OF THE VALUE OF THE EXISTING STRUCTURE.) | | | SECTION 94-546 | | | | | | 5) BEFORE A CO IS ISSUED AN ELEVATION | | | CERTIFICATE WILL BE REQUIRED | | | | | | 6) IN AREAS OF QUESTIONABLE SOILS A SOIL | | | REPORT IS REQUIRED PER R401.1 FBC | | | | | | 7) THE FOLLOWING CORRECTION ARE REQUIRED | | | ON THE PRODUCT APPROVALS | | | A) GAF ROOFING: PROVIDE FASTENER SYSTEM | | | BEING USED AND CALCULATIONS FOR THE | | | ENHANCED FASTENING FOR PERIMITER ZONE 2 | | | AND CORNER ZONE 3 | | | B) CLOPAY GARAGE DOORS: NOA'S DO NOT | | | MEET THE DESIGN PRESSURES AS STATED IN | | | THE ENGINEERED DRAWINGS ON S/3. ALSO | | | BOTH NOA'S ARE FOR METAL DOORS AND | | | DRAWINGS HAVE WOOD AND ALUMINUM. DOORS | | | WITH GLAZING THE GLASS SHALL BE IMPACT | | | RATED | | | C) MADDEN MFG: SHUTTER PRODUCT APPROVALS | | | SHALL BE SUBMITTED WITH A KEY PLAN, | | | SCEDULE AND THE NOA DRAWING CLEARLY | | | MARKED/CIRCLED SHOWING THE COMPONENTS, | | | TYPE OF MOUNTING, TYPE OF ANCHOR, ETC | | | D) PGT WINDOWS: REQUIRE AN UPDATED | | | FLORIDA COVER AND NOA (FL#243-R3 & NOA# | | | 03-1105.01) | | | E) CECO DOORS: NOA STATES A MAXIMUM | | | HEIGHT OF 7'-0" AND DRAWING SPECIFY | | | 7'-6" ON THE DOOR AND WINDOW SCHEDULE ON | | | A/1. | | | | | | 8) WINDOW SCHEDULE SHOWS WINDOW A AS | | | CASEMENT, ELEVATION SHOWS FIXED, NO NOA | | | FOR CASEMENT, PLEASE CLARIFY | | | | | | 9) SECTION 05/S1 SHOWS TB2 AND ROOF | | | FRAMING PLAN SHOWS TB1 PLEASE CLARIFY, | | | ALSO THERE IS NO TB2 ON THE BEAM | | | SCHEDULE ON S/2 | | | | | | 10) PROVIDE DETAIL ON ATTACHMENT OF 4X10 | | | BEAM TO POST (ASSUME THERE IS POST UNDER | | | THE DECORATIVE WOOD POSTS) IF SO SHOW | | | PAD/FOOTING AND ATTACHMENT | | | | | | 11) ALSO CONFIRM WITH THE ENGINEER THAT | | | THE SPANS ON 4X10 BEAMS WITH OUTLOOKERS | | | WILL BE ADEQUATE AS THE UNSUPPORTED | | | SPANS ARE LARGER THAN WOULD BE ALLOWABLE | | | FOR BUILT UP BEAMS | | | | | | 12) SCTION 02/S1 AND 03/S1 SEEM SIMILAR | | | BUT BEAM ATTACHMENT DETAIL SHOULD BE | | | DIFFERENT AT EXISTING GARAGE WALL, | | | PLEASE CLARIFY | | | | | | 13) WEST ELEVATION ON A/2 STATES | | | DIFFERENT ROOFING APPLICATION THAN NORTH | | | ELEVATION AND BUILDING SECTIONS ON A/3 | | | PLEASE CLARIFY | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2006-09-22 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-09-22 |
Time |
14:22 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-09-22 |
Time |
13:18 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2006-06-08 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-06-08 |
Time |
13:24 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-06-08 |
Time |
12:09 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2007-01-02 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-01-02 |
Time |
12:20 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-01-02 |
Time |
12:20 |
Sent To |
P |
|
| Notes |
| 2007-01-02 12:22:44 | REVISION DELETED TANKLESS GAS HEATERS. TO RELOCATE OLD | | | GAS HEATERS. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2006-09-23 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-09-23 |
Time |
07:04 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-09-23 |
Time |
07:04 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2006-06-13 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-06-13 |
Time |
13:44 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-06-13 |
Time |
13:44 |
Sent To |
B |
|
| Notes |
| 2006-06-13 00:00:00 | DENIED; | | | | | | 1. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES A.3.1(4). INCLUDE | | | EXISTING GAS APPLIANCES AND THE LONGEST | | | RUN. NEW HEATERS AND DRYER WILL BE ADDED | | | TO OLD SYSTEM. | | | 2. INDICATE THE DELIVERY PRESSURE (PSI) | | | PER FBC-2004 FUEL GAS CODE SEC. 402.2. | | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. | | | 3. SUBMIT MANUFACTURE SHEETS FOR WATER | | | HEATERSTO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2004 FUEL GAS CODE SEC 402.2. MOST | | | INST. HOT HEATERS ARE AROUND 200,000 | | | BTU'S. | | | 4. UNDER GROUND GAS PIPE TO BE (PE) | | | POLYETHYLENE PLASTIC PIPE. | | | GAS PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2006-12-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-12-26 |
Time |
11:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-26 |
Time |
11:50 |
Sent To |
M |
|
| Notes |
| 2006-12-26 11:51:16 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-10-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-10-04 |
Time |
16:22 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-10-04 |
Time |
16:22 |
Sent To |
P |
|
| Notes |
| 2006-10-04 00:00:00 | TO "P" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-09-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-19 |
Time |
14:52 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-19 |
Time |
14:52 |
Sent To |
E |
|
| Notes |
| 2006-09-19 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-09-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-15 |
Time |
08:25 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-15 |
Time |
08:25 |
Sent To |
Z |
|
| Notes |
| 2006-09-15 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-08-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-18 |
Time |
14:48 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-18 |
Time |
14:48 |
Sent To |
Z |
|
| Notes |
| 2006-08-18 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-06-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-06 |
Time |
12:25 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-06 |
Time |
12:25 |
Sent To |
E |
|
| Notes |
| 2006-06-06 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2006-06-28 |
Time |
|
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-15 |
Time |
15:17 |
Sent To |
|
|
| Notes |
| 2006-05-15 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2006-09-27 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-09-27 |
Time |
09:39 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2006-09-27 |
Time |
09:39 |
Sent To |
|
|
| Notes |
| 2006-09-27 00:00:00 | NO MECHANICAL PLANS SUBMITTED, AND NO | | | MECHANICAL PERMIT NUMBER APPLIED FOR AT | | | THIS TIME. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-06-14 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-06-14 |
Time |
08:55 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-06-14 |
Time |
08:55 |
Sent To |
B |
|
| Notes |
| 2006-06-14 00:00:00 | *** DENIED *** | | | 1) ENERGY CALCULATIONS NEED TO BE ON | | | FORM 600A-04 (2004) PER FBC 13-600.3.A . | | | | | | 2) ENERGY CAL'S. NEED TO BE SIGNED BY | | | OWNER/AGENT, PER 2004 FBC 13-600.3.ABC.2 | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2007-01-02 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-01-02 |
Time |
12:23 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-01-02 |
Time |
12:22 |
Sent To |
B |
|
| Notes |
| 2007-01-02 12:24:32 | CHANGED LOCATION OF WASHER AND DRYER. REVISION |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2006-10-06 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-10-06 |
Time |
14:56 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-10-06 |
Time |
14:56 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2006-09-23 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-09-23 |
Time |
07:06 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-09-23 |
Time |
07:06 |
Sent To |
M |
|
| Notes |
| 2006-09-23 00:00:00 | DENIED; | | | 1.THE AUTOMATIC CLOTHES WASHER THAT IS | | | TO BE REMOVED MUST BE RELOCATED IN THE | | | HOUSE. MINIMUM REQUIRED PLUMBING | | | FIXTURES REQUIRES A WASHER HOOK UP. SEE | | | FBC-2004 PLUMBING TABLE 403.1(7)R-3. | | | WASHER IS NOT SHOWN ON ELECTRICAL PANEL | | | SCHEDULE. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-06-13 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-06-13 |
Time |
13:36 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-06-13 |
Time |
13:36 |
Sent To |
G |
|
| Notes |
| 2006-06-13 00:00:00 | DENIED; | | | 1.THE AUTOMATIC CLOTHES WASHER FIXTURE | | | DRAIN SHALL CONNECT TO A BRANCH DRAIN OR | | | DRANAGE STACK A MINIMUM OF 3" IN | | | DIAMETER. FHC-2004 PLUMBING SEC.406.3. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2006-10-06 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2006-10-06 |
Time |
16:44 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2006-09-15 |
Time |
17:56 |
Sent To |
|
|
| Notes |
| 2006-10-06 00:00:00 | SEE MICHELLE'S APPROVAL ON PLANSLM |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2006-08-21 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-08-21 |
Time |
18:57 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-08-21 |
Time |
18:57 |
Sent To |
|
|
| Notes |
| 2006-08-21 00:00:00 | DENIED, | | | 1. THE PROPOSED ACCESSORY STRUCTURE IS | | | OVER THE ZONING REQUIREMENTS OF 1000SQ | | | FT INCLUDING THE EXISTING GARAGE. SEC | | | 94-304 (B)(1) | | | | | | 2. APPLICANT MAY APPLY FOR A VARIANCE | | | FOR EXCEEDING THE SQUARE FOOTAGE | | | REQUIREMNTS. | | | 3. APPLICANT MAY ATTACH TO EXISTING | | | STRUCTURE AND PROPOSED TO THE EXISTING | | | MAIN STRUCTURE.THIS CAN BE ATTACHED | | | WITH A SOLID ROOF BREEZEWAY AND MUST | | | MEET THE SETBACKS FOR SF7 (FRONT SETBACK | | | 15FT, SIDE(BOTH SIDE TOTALLY 15FT) AND | | | REAR SETBACK 10% LOT DEPTH OR 15FT | | | WHICHEVER IS LESS. | | | 4. SITEPLAN DOES NOT SHOW THE LOCATION | | | OF THE PROPOSED A/C UNIT | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2006-06-05 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-06-05 |
Time |
15:51 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-06-05 |
Time |
15:51 |
Sent To |
|
|
| Notes |
| 2006-06-05 00:00:00 | DENIED, | | | 1. MUST PROVIDE THE FRONT SETBACK OF THE | | | PROPOSED TWO CAR GARAGE ON THE TWO SET | | | OF SITEPLANS CLEARLY (NOT CLEARLY SHOWN | | | ON THE SITEPLAN) | | | 2. THE NEW A/C MUST BE SHOWN ON THE TWO | | | SET OF SITEPLANS WITH THE SETBACK ON THE | | | SIDE (FROM A/C TO PROPERTY LINE) | | | | | | NOTE: SEC 94-303 MECHANICAL/POOL | | | EQUIPMENT/GENERATOR MAY NOT PROJECT MORE | | | THAN FOUR FEET INTO A SETBACK. | | | | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 | | | |
|
|