Plan Review Details - Permit 06050493
Plan Review Stops For Permit 06050493
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2006-07-11 Cont ID  
Sent By mjacobs Date 2006-07-11 Time 07:06 Rev Time 0.00
Received By mjacobs Date 2006-07-11 Time 06:15 Sent To P
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2006-06-15 Cont ID  
Sent By mjacobs Date 2006-06-15 Time 07:15 Rev Time 0.00
Received By mjacobs Date 2006-06-15 Time 06:16 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-07-10 Cont ID  
Sent By btrobaug Date 2006-07-10 Time 11:40 Rev Time 0.50
Received By btrobaug Date 2006-07-10 Time 11:31 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-06-02 Cont ID  
Sent By btrobaug Date 2006-06-02 Time 07:13 Rev Time 0.50
Received By btrobaug Date 2006-06-02 Time 07:02 Sent To P
Notes
2006-06-02 00:00:00 
  
 DENIED
  
 THE APPLICATIION AND SCHEMATICS DO NOT
 INDICATE A POOL HEATER. THERE IS LOAD
 CALCULATIONS AND HEAT PUMP
 SPECIFICATIONS SUBMITTED. PLEASE
 CLARIFY, REMOVE UNECESSARY DDOCUMENTS OR
 CHANGE THE DRAWINGS TO SHOW THE INTENDED
 SCOPE.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
  
  

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2006-06-05 Cont ID  
Sent By mperson Date 2006-06-05 Time 09:04 Rev Time 0.00
Received By mperson Date 2006-06-05 Time 09:04 Sent To B
Notes
2006-06-05 00:00:00NOTE: NO GAS HEATER

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-07-05 Cont ID  
Sent By adarroug Date 2006-07-05 Time 10:43 Rev Time 0.00
Received By adarroug Date 2006-07-05 Time 10:43 Sent To E
Notes
2006-07-05 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-06-28 Cont ID  
Sent By adarroug Date 2006-06-28 Time 11:09 Rev Time 0.00
Received By adarroug Date 2006-06-28 Time 11:09 Sent To Z
Notes
2006-06-28 00:00:00TO "Z" BOX/RESUB--NEW SHEETS

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-05-31 Cont ID  
Sent By adarroug Date 2006-05-31 Time 14:51 Rev Time 0.00
Received By adarroug Date 2006-05-31 Time 14:51 Sent To E
Notes
2006-05-31 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2006-06-15 Time   Rev Time 0.00
Received By adarroug Date 2006-05-15 Time 09:13 Sent To  
Notes
2006-05-15 00:00:00TO "Z" BOX

Review Stop P PLUMBING
Rev No 2 Status P Date 2006-07-10 Cont ID  
Sent By mperson Date 2006-07-10 Time 13:42 Rev Time 0.33
Received By mperson Date 2006-07-10 Time 13:42 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2006-06-05 Cont ID  
Sent By mperson Date 2006-06-05 Time 08:17 Rev Time 0.45
Received By mperson Date 2006-06-05 Time 08:16 Sent To G
Notes
2006-06-05 00:00:00******DENIED******
 REFERENCE: FBC-2004 SEC. 424.2 SWIMMING
 POOLS OR FBC-2004 RESIDENTIAL SEC.R4101
  
 THE FOLLOWING INFORMATION IS REQUIRED
 FROM PLUMBING PLAN REVIEW FOR A PERMIT:
  
 1) FBC-2004 SEC. 424.2.6.6.5, OR
 FBCR-2004 SEC. R4101.6.6.5 WHERE
 PROVIDED, THE VACUUM OR PRESSURE CLEANER
 FITTING SHALL BE LOCATED AT LEAST 6" AND
 NOT GREATER THAN 12" BELOW THE MINIMUM
 OPER- ATING WATER LEVEL OR AS AN
 ATTACHMENT TO THE SKIMMER.(MANUFACTURER
 CUT SHEETS REQUIRED OR ADD MAKE AND
 MODEL NUMBER TO PRINTS)
 2) FBC-2004 SEC. 424.6.6 OR FBC-2004
 RESIDENTIAL SEC. R4101.6.6: ENTRAPMENT
 PROTECTION FOR SUCTION INLETS. PLEASE
 SUBMIT AN ENGINEERED TABLE FOR "VENT
 PIPE MAXIMUM LENGTH" INDICATING PUMP
 SIZES, AVERAGE FLOW, AND MAXIMUM LENGTH
 OF THE1-1/2" PVC VENT PIPE, FROM WHERE
 IT STARTS TO WHERE IT ENDS UP, COMPLYING
 WITH THE THREE SECOND RELEASE.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721
  
  
  

Review Stop Z ZONING
Rev No 2 Status P Date 2006-07-02 Cont ID  
Sent By mmclean Date 2006-07-02 Time 18:56 Rev Time 0.00
Received By mmclean Date 2006-07-02 Time 18:56 Sent To I
Notes
2006-07-02 00:00:00REVISION - NEW PLANS.
 NOTE: THE PROPOSED DECK MUST NOT
 ENCROACH IN THE 3FT UTILITY EASEMENT IN
 THE REAR OF PROPERTY. (NO ROOF FOR DECK)

Review Stop Z ZONING
Rev No 1 Status P Date 2006-05-30 Cont ID  
Sent By mmclean Date 2006-05-30 Time 15:38 Rev Time 0.00
Received By mmclean Date 2006-05-30 Time 15:38 Sent To I
Notes
2006-05-30 00:00:00NOTE: THE PROPOSED DECK MUST NOT
 ENCROACH IN THE 6FT EASEMENT ON THE SIDE
 OF PROPERTY.