| Plan Review Stops For Permit 06050449 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
P |
Date |
2006-05-15 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2006-05-15 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2006-05-15 |
Time |
14:52 |
Sent To |
|
|
| Notes |
| 2006-05-15 00:00:00 | CREATE EXT# 0012 FOR THE UNIT #146 UNDER | | | THE MAIN ADDRESS 550 S ROSEMARY AVE |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2006-06-28 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2006-06-28 |
Time |
09:05 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2006-05-10 |
Time |
10:49 |
Sent To |
|
|
| Notes |
| 2006-05-10 00:00:00 | EXT REQUIRED FOR STE #146 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2006-10-31 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-10-31 |
Time |
13:16 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-10-31 |
Time |
12:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2006-06-28 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-06-28 |
Time |
09:13 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-06-28 |
Time |
09:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2006-05-24 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-05-24 |
Time |
09:37 |
Rev Time |
2.00 |
| Received By |
alange |
Date |
2006-05-24 |
Time |
09:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2007-02-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-02-18 |
Time |
16:34 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-02-18 |
Time |
16:22 |
Sent To |
|
|
| Notes |
| 2007-02-18 16:34:32 | ELEC OK,STAMPED |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2006-12-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-12-10 |
Time |
09:07 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-12-10 |
Time |
08:33 |
Sent To |
|
|
| Notes |
| 2006-12-10 09:08:43 | ******* UNSAT5TH REVIEW******** | | | | | | ** PLEASE KNOW THIS IS THE FIFTH TIME PLANS HAVE BEEN | | | REVIEWED, HOWEVER ONLY THE SECOND TIME ACTUALLY UNDER | | | PERMIT APPLICATION. PLEASE SEE NOTE BELOW WITH RESPECT | | | TO FLORIDA STATUTES WITH RESPECT TO DESIGN | | | PROFESSIONALS AND REPEAT COMMENTS FOR CODE COMPLIANCE. | | | | | | ** PLEASE SEE SOME NOTES FROM PREVIOUS REVIEWS WHICH | | | STILL NEED TO BE ADDRESSED. | | | | | | | | | | | | 1) NOTE: PLEASE INDICATE ALL CONTINUOUS LOADS AT 125%. | | | 215.3, 230.42 ETC. | | | PLEASE SEE LOAD SHOWN ON TRANSFORMER PLACES LOAD AT | | | 44.97KVA ON PREVIOUS PLANS AND NOW 47.92 WHICH | | | INDICATES LOADS EXCEEDING TRANSFORMER AS SHOWN. PLEASE | | | SEE ABOVE NOTES, AS CONTINUOUS LOADS WILL PLACE THIS | | | LOAD OVER RATING OF SAID 45KVA UNIT. | | | PLEASE CLARIFY WHAT APPEARS TO BE ADDITIONAL LOAD ON | | | "PA"? HOW, ARE THESE LOADS DIFFERENT OF THAT ON "DP"? | | | PLEASE SHOW COMPLETE LOAD CALCULATIONS PER ABOVE AND | | | 220.3, 220.10, 220.11, 220.13 | | | ETC. AND 215.3, 230.42 ETC | | | | | | 2) NOTE:PREVIOUS NOTES BELOW WHICH HAVE NOT BEEN | | | ADDRESSED. PLEASE SEE RESPONSE LETTER MENTIONS | | | OCCUPANCY SENSORS WERE ADDED HOWEVER THIS DOES NOT | | | COMPLETE COMMENTS FROM PREVIOUS REVIEWS. | | | PLEASE SEE MISSING SCHEDULING. | | | PLEASE SEE MAXIMUM TIMES FOR DEVICES. | | | PLEASE SEE TIME CLOCK STILL SHOWN, HOWEVER NO | | | CIRCUITING ETC. | | | PLEASE SEE NO LIGHTING POWER DENSITIES? | | | PLEASE KNOW BASED ON INFORMATION AS SUBMITTED A | | | COMPLETE REVIEW CAN NOT BE DONE. | | | ** PLEASE SEE 700.12E AS ALL EM/ EXT LTS SHALL BE | | | INDICATED AHEAD OF ANY OC/TIMER TYPE DEVIE. | | | | | | ** PREVIOUS REVIEW NOTES FROM THE TWO PREVIOUS REVIEWS | | | ALONE. ** | | | NO, PLEASE SEE CONTROLS FOR ALL SEPARATE SPACES DO NOT | | | SEEM TO BE INDICATED.(BATHRM) PLEASE SEE "S" ARE BEING | | | NOTED IN RESPONSE LTR AND SHOWN AS OC , HOWEVER IF | | | THESE DEVICES ARE LOCATED BEHIND WALL WHICH SEPARATES | | | STORAGE/BACK AREA FROM STORE SALES AREAS, HOW WOULD | | | THESE OCSENSOR TYPE SWITCHES BE EFFECTIVE. PLEASE | | | INDICATE THE NORMAL SCHEDULING TIME OF DAY. PLEASE | | | CLARIFY WHERE THE MAX TIMES PERMITTED ON THE DEVICES AS | | | CHOSEN IS LOCATED ON PLANS? (OC TYPE 30MINS) (TIMER | | | TYPE 4HRS MAX). | | | PLEASE SEE MISSING THE PERFORMANCE CALCULATIONS PER | | | 13-415.2, 13-415.2.ABC.1, TABLES, 415.2.C.1, 415.2.B.1 | | | PLEASE SHOW A BREAK DOWN ON MAX LIGHTING POWER | | | DENSITIES. | | | | | | ** PREVIOUS REVIEW NOTES** | | | PLEASE SEE FBC 2004 CHAPTER 13, 13-415.1.ABC.1.1, | | | .1.2, AND .1.3. | | | PLEASE SEE SPACE IS IN A BUILDING GREATER THAN 5000 SQ | | | FT AND CONTROLS FOR LIGHTING WILL BE REQUIRED (SHOWN), | | | HOWEVER PLEASE SEE .1.2, AND .1.3 AS CONTROLS FOR | | | SEPARATE SPACES WITH FLR TO CEILING PARTITIONS ARE | | | REQUIRED. PLEASE SEE PERMITTED TYPE OF DEVICES AS | | | "TIMER" TYPE OVER RIDES ARE ONLY PERMITTED TO OVER RIDE | | | NORMAL SCHEDULING A MAX OF 4HRS. PLEASE SEE ANY | | | OCCUPANCY SENSOR(S) TYPE DEVICES SHALL ONLY PERMIT A | | | MAX OF 30 MINS. PLEASE SHOW LOCATION OF THESE OVER | | | RIDES DEVICES AND PLEASE SEE THESE ARE REQUIRED AT THE | | | POINT OF ENTRANCE INTO SPACE SO THE OCCUPANT CAN | | | VISUALLY SEE LTS BEING CONTROLLED. PLEASE SEE EXCEPTION | | | FOR OCC SENSORS. PLEASE SEE BATH R, STOCK RM ETC,,, | | | IT IS NOTED BY THIS OFFICE THAT A TIME CLOCK IS BEING | | | PROVIDED, HOWEVER PLEASE SEE ABOVE FOR OTHER | | | REQUIREMENTS. | | | | | | 3) NOTE: PLEASE SEE NOTE #1, BASED ON THE UNCERTAINTY | | | OF LOADS ON THE TRANSFORMER, THE RISER MAY BE NEEDING | | | TO BE REVISED AS STATED ON PREVIOUS REVIEWS. THE | | | TRANSFORMER WAS CHANGED ONCE TO 75 KVA WHICH WAS OK, | | | HOWEVER NOT ALL AREAS OF PLANS WERE REVISED TO | | | CORRELATE WITH THIS. | | | | | | 4) NOTE:PLEASE SEE AS NOTED ON PREVIOUS REVIEWS, DO | | | NOT USE THE "RUBBER STAMP" WHICH CONTAINS THE WORDING | | | OF "CERTIFICATE" FOR SEAL. IT IS NOTED THAT A RAISED | | | SEAL IS BEING PLACED OVER THIS RUBBER STAMP. | | | THE RUBBER STAMP FOR USE IN THE STATE OF FLORIDA IS NOT | | | PERMITTED AND SEEING THAT IT WORDING IS NO LONGER | | | VALID, PLEASE DO NOT USE. | | | FAC 61G15-23.001, FS 471.025 | | | AS PREVIOUSLY NOTED. | | | | | | 5) NOTE: PLEASE SEE AS NOTED ABOVE, PLEASE SEE FLORIDA | | | STATUTES 553.80(2)(B) WITH RESPECT TO DESIGN | | | PROFESSIONALS AND REPEAT COMMENTS FOR CODE COMPLIANCE. | | | PLEASE SEE AS THIS IS ONLY THE 2ND REVIEW UNDER PERMIT | | | APPLICATION THE FEE AS MENTIONED IN THE ATTACHED SHEET | | | IS NOT ASSESSED, HOWEVER IF PLANS COME BACK WITH ANY OF | | | THE ITEMS IN THE NOTES ABOVE NOT ADDRESSED, A 4X FEE IS | | | ASSESSED TO THE DESIGN PROFESSIONAL BASED ON THE | | | PORTION OF BASE PERMIT FEE ATTRIBUTED TO PLAN REVIEW. | | | *** PLEASE KNOW AT THIS TIME, ONE SET OF ME PLANS WILL | | | BE RETAINED AND HELD IN FILE FOR POSSIBLE REVIEW BY THE | | | FLORIDA BOARD OF PROFESSIONAL ENGINEERS AND LEGAL | | | COUNSEL TO THE BOARD. | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2006-10-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-10-28 |
Time |
19:18 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-10-28 |
Time |
18:27 |
Sent To |
|
|
| Notes |
| 2006-10-28 19:18:36 | ******* UNSAT ******** | | | | | | ** PLEASE SEE THIS IS THE FIRST REVIEW UNDER PERMIT. | | | | | | | | | | | | 1) NOTE: OK. | | | | | | 2) NOTE: OK. | | | | | | 3) NOTE:OK. | | | | | | 4) NOTE: OK. | | | | | | 5) NOTE:NO/ OK, PLEASE SEE TRANSFORMER SIZE NOW SEEMS | | | TO HAVE BEEN CHANGED, HOWEVER PLEASE SEE ME-2.0 WHICH | | | STILL INDICATES A 45KVA UNIT (NOTE #11). | | | PLEASE SEEMIN OCP WHICH IS REQUIRED AS THE LOAD AT | | | 277/480V IS BEING SHOWN AT 75KVA, PLEASE SEE @THIS, | | | THE OCP WOULD BE JUST OVER 90A'S WHICH IS BEING SHOWN. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE INDICATE ALL CONTINUOUS | | | LOADS AT 125%. 215.3,230.42 ETC. | | | PLEASE SEE LOADSHOWN ON TRANSFORMER | | | PLACES LOAD AT 44.97KVA. PLEASE SEE | | | ABOVE NOTES, AS CONTINUOUS LOADS WILL | | | PLACE THIS LOAD OVER RATING OF SAID | | | 45KVA UNIT. | | | PLEASE CLARIFY WHAT APPEARS TO BE | | | ADDITIONAL LOAD ON "PA"? HOW, ARE THESE | | | LOADS DIFFERENT OF THAT ON "DP"? | | | PLEASE SHOW COMPLETE LOAD CALCULATIONS | | | PER ABOVE AND 220.3,220.10,220.11,220.13 | | | ETC. AND 215.3, 230.42 ETC | | | | | | 6) NOTE: OK. | | | | | | 7) NOTE:NO, PLEASE SEE CONTROLS FOR ALL SEPARATE | | | SPACES DO NOT SEEM TO BE INDICATED.(BATHRM) PLEASE SEE | | | "S" ARE BEING NOTED IN RESPONSE LTR AND SHOWN AS OC , | | | HOWEVER IF THESE DEVICES ARE LOCATED BEHIND WALL WHICH | | | SEPARATES STORAGE/BACK AREA FROM STORE SALES ARES, HOW | | | WOULD THESE OCSENSOR TYPE SWITCHES BE EFFECTIVE. | | | PLEASE INDICATE THE NORMAL SCHEDULING TIME OF DAY. | | | PLEASE CLARIFY WHERE THE MAX TIMES PERMITTED ON THE | | | DEVICES AS CHOSEN IS LOCATED ON PLANS? (OC TYPE 30MINS) | | | (TIMER TYPE 4HRS MAX). | | | PLEASE SEE MISSING THE PERFORMANCE CALCULATIONS PER | | | 13-415.2, 13-415.2.ABC.1, TABLES, 415.2.C.1, 415.2.B.1 | | | PLEASE SHOW A BREAK DOWN ON MAX LIGHTING POWER | | | DENSITIES. | | | | | | ** PREVIOUS REVIEW NOTES** | | | PLEASE SEE FBC 2004 CHAPTER 13, 13-415.1.ABC.1.1, | | | .1.2, AND .1.3. | | | PLEASE SEE SPACE IS IN A BUILDING | | | GREATER THAN 5000 SQ FT AND CONTROLS FOR | | | LIGHTING WILL BE REQUIRED (SHOWN), | | | HOWEVER PLEASE SEE .1.2, AND .1.3 AS | | | CONTROLS FOR SEPARATE SPACES WITH FLR TO | | | CEILING PARTITIONS ARE REQUIRED. PLEASE | | | SEE PERMITTED TYPE OF DEVICES AS "TIMER" | | | TYPE OVER RIDES ARE ONLY PERMITTED TO | | | OVER RIDE NORMAL SCHEDULING A MAX OF | | | 4HRS. PLEASE SEE ANY OCCUPANCY SENSOR(S) | | | TYPE DEVICES SHALL ONLY PERMIT A MAX OF | | | 30 MINS. PLEASE SHOW LOCATION OF THESE | | | OVER RIDES DEVICES AND PLEASE SEE THESE | | | ARE REQUIRED AT THE POINT OF ENTRANCE | | | INTO SPACE SO THE OCCUPANT CAN VISUALLY | | | SEE LTS BEING CONTROLLED. PLEASE SEE | | | EXCEPTION FOR OCC SENSORS. | | | PLEASE SEE BATH R, STOCK RM ETC,,, | | | IT IS NOTED BY THIS OFFICE THAT A TIME | | | CLOCK IS BEING PROVIDED , HOWEVER | | | PLEASE SEE ABOVE FOR OTHER REQUIREMENTS. | | | | | | 8) NOTE:OK, HOWEVER SEE NOTE ABOVE WITH RESPECT TO | | | THE SIZE AND OCP FOR UNIT. THESE MAY INDEED CHANGE. | | | | | | PLEASE SEE NOTES SHOW #8 FOR | | | FEED TO TRANSFORMER, HOWEVER A 60A BRKR | | | IS SHOWN. PLEASE SEE 310.16, 240.4, | | | 110.14, AS THE MAX OCP FOR THE #8' IS | | | 50A'S. PLEASE SEE 310.16 75 DEGREE | | | COLUMN AS THE #8'S ARE RATED AT 50A'S. | | | PLEASE ADJUST ONCE ALL CALCULATIONS ARE | | | DONE. | | | | | | *** NEW NOTE ** | | | 9) NOTE: PLEASE SEE RISER MENTIONS A NEW 150A | | | DISCONNECTAT LANDLORDS METER CENTER, IF PART OF THIS | | | PERMIT, PLEASE COMPLETE RISER SHOWING THIS. IF NOT | | | SEPARATE PERMIT AND PLANS WILL BE REQUIRED FOR THIS | | | INSTALLATION. | | | | | | 10) NOTE: PLEASE BE SURE NEW "E" SHEETS ONLY CONTAIN | | | THE RAISED SEAL PER FAC 61G15-23.001 FOR THE NEW | | | WORDING "LICENSE" . THE OLDER SEALS WITH THE WORDING OF | | | "CERTIFICATE ARE NO LONGER VALID. RULED PAST ON 2/04 | | | AND EXTENDED TO 12/31/05. | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2006-07-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-07-24 |
Time |
20:57 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-07-24 |
Time |
19:58 |
Sent To |
PC |
|
| Notes |
| 2006-07-24 00:00:00 | ******* UNSAT ******** | | | | | | ** PLEASE KNOW, ALL PLANS ARE REQUIRED | | | TO HAVE THE STAMPED FROM CITY PLACE ON | | | ALL SHEETS. PLEASE CONTACT CITY PLACE AT 561-820-0074 | | | PLEASE DO NOT SUBMIT WITHOUT STAMPS, AS | | | PLANS MAY BE REJECTED ON THAT ALONE. | | | | | | | | | ** PLEASE KNOW PLANS ARE STILL ONLY | | | BEING SUBMITTED FOR "PLAN REVIEW" AND | | | NOT FOR PERMIT. | | | | | | ** PLEASE SEE THE FOLLOWING COMMENTS ARE | | | BASED ON PLANS SUBMITTED FOR THIS REVIEW | | | ONLY AND PLANS DATED 7/6/06. | | | | | | 1) NOTE: PLEASE SEE TITLE SHEET IS | | | INDICATING A 2004 NATIONAL ELECTRICAL | | | CODE, HOWEVER PLEASE KNOW, THERE IS NO | | | 2004 NEC AND PLEASE KNOW AS PER CHAPTER | | | 27 OF THE 2004 FBC, THE 2002 NEC IS | | | CURRENTLY IN EFFECT. PLEASE REVISE AND | | | ADJUST. | | | | | | 2) NOTE: PLEASE SEE DESIGNATION BEHIND | | | RECEPT CIRCUITING ON E 2.0 PLANS SHOW | | | "E" AND "F" WHICH COULD NOT BE LOCATED | | | ON SYMBOL LIST/ | | | PLEASE CLARIFY. | | | 106.1.2 FBC ADMIN SECT. | | | | | | 3) NOTE: PLEASE SEE COLOR CODING FOR | | | 277/480V SHALL BE BROWN, PURPLE, YELLOW. | | | IT IS UNCLEAR WHERE BLACK AND YELLOW | | | STRIP COMES FROM? | | | PLEASE KNOW, AS PER CITY AND PALM BEACH | | | COUNTY LOCAL AMENDMENTSTHE ABOVE COLOR | | | CODING HAS BEEN IN EFFECT FOR 25 PLUS | | | YRS. PLEASE KNOW AS OF THE 2004 FBC | | | LOCAL TECHNICAL AMENDMENTS DO NOT EXIST, | | | HOWEVER COLOR CODING FOR CITY OF WEST | | | PALM BEACH AND PALM BEACH COUNTY SHALL | | | REMAIN THE SAME AS ALL CURRENT | | | ELECTRICAL SYSTEMS IN BUILDINGS ARE | | | CODED PER ABOVE ANDTHE NEC DOES NOT | | | PROVIDE COLOR CODING FOR 277/480A. | | | 90.4 | | | | | | 4) NOTE: PLEASE PROVIDE LOAD | | | CALCULATIONS INDICATING LOADS FOR TRACK | | | LIGHTING PER 220.12B. PLEASE SHOW. | | | | | | 5) NOTE: PLEASE INDICATE ALL CONTINUOUS | | | LOADS AT 125%. 215.3,230.42 ETC. | | | PLEASE SEE LOADSHOWN ON TRANSFORMER | | | PLACES LOAD AT 44.97KVA. PLEASE SEE | | | ABOVE NOTES, AS CONTINUOUS LOADS WILL | | | PLACE THIS LOAD OVER RATING OF SAID | | | 45KVA UNIT. | | | PLEASE CLARIFY WHAT APPEARS TO BE | | | ADDTIONAL LOAD ON "PA"? HOW, ARE THESE | | | LOADS DIFFERENT OF THAT ON "DP"? | | | PLEASE SHOW COMPLETE LOAD CALCULATIONS | | | PER ABOVE AND 220.3,220.10,220.11,220.13 | | | ETC. AND 215.3, 230.42 ETC | | | | | | 6) NOTE: PLEASE SEE GROUNDING NOTE FOR | | | TRANSFORMER MENTIONS TO GROUND UNIT TO | | | EITHER BUILDING STEEL "OR" COLD WATER. | | | PLEASE SEE 250.50, 250.66 , | | | 250.20,250.30 AS BOTH WILL BE REQUIRED. | | | PLEASE NOTE, THIS SHALL BE ATTACHED AND | | | PART OF THE BUILDINGS GE SYSTEM. | | | | | | 7) NOTE: PLEASE SEE FBC 2004 CHAPTER 13, | | | 13-415.1.ABC.1.1, .1.2, AND .1.3. | | | PLEASE SEE SPACE IS IN A BUIDLIGN | | | GREATER THAN 5000 SQ FT AND CONTROLS FOR | | | LIGHTING WILL BE REQUIRED (SHOWN), | | | HOWEVER PLEASE SEE .1.2, AND .1.3 AS | | | CONTROLS FOR SEPARATE SPACES WITH FLR TO | | | CEILING PARTITIONS ARE REQUIRED. PLEASE | | | SEE PERMITTED TYPE OF DEVICES AS "TIMER" | | | TYPE OVER RIDES ARE ONLY PERMITTED TO | | | OVER RIDE NORMAL SCHEDULING A MAX OF | | | 4HRS. PLEASE SEE ANY OCCUPANCY SENSOR(S) | | | TYPE DEVICES SHALL ONLY PERMIT A MAX OF | | | 30 MINS. PLEASE SHOW LOCATION OF THESE | | | OVER RIDES DEVICES AND PLEASE SEE THESE | | | ARE REQUIRED AT THE POINT OF ENTRANCE | | | INTO SPACE SO THE OCCUPANT CAN VISUALLY | | | SEE LTS BEING CONTROLLED. PLEASE SEE | | | EXCEPTION FOR OCC SENSORS. | | | PLEASE SEE BATH R, STOCK RM ETC,,, | | | IT IS NOTED BY THIS OFFICE THAT A TIME | | | CLOCK IS BEING PROIVIDED , HOWEVER | | | PLEASE SEE ABOVE FOR OTHER REQUIREMENTS. | | | | | | 8) NOTE: PLEASE SEE NOTES SHOW #8 FOR | | | FEED TO TRANSFORMER, HOWEVER A 60A BRKR | | | IS SHOWN. PLEASE SEE 310.16, 240.4, | | | 110.14, AS THE MEX OCP FOR THE #8' IS | | | 50A'S. PLEASE SEE 310.16 75 DEGREE | | | COLUMN AS THE #8'S ARE RATED AT 50A'S. | | | PLEASE ADJUST ONCE ALL CALCULATIONS ARE | | | DONE. | | | | | | | | | ** IMPORTANT** | | | | | | PLEASE SURE WHEN RESUBMITTING PLANS TO | | | COMPLETELY REMOVE ANY OLD/VOIDED SHEETS | | | AND ONLY INSERT NEW REVISED SHEETS INTO | | | TWO COMPLETE SETS FOR REVIEW AND | | | STAMPING. PLEASE ONLY SUBMIT ONE SET OF | | | THE OLD/VOIDED SHEETS FOR REFERENCE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-06-21 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-06-21 |
Time |
17:04 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2006-06-21 |
Time |
16:57 |
Sent To |
|
|
| Notes |
| 2006-06-21 00:00:00 | | | | NONCOMPLIANT | | | | | | | | | 1} PLEASE SEE THE EMERGENCY LIGHTS MUST | | | BE ON THE SAME CIRCUITS RTHE LIGHTING | | | IN THE AREA PER 700.12(E), 2002 NEC. | | | | | | "THE BRANCH CIRCUIT FEEDING THE UNIT | | | EQUIPMENT SHALL BE THE SAME BRANCH | | | CIRCUIT AS THAT SERVING THE NORMAL | | | LIGHTING IN THE AREA AND CONNECTED AHEAD | | | OF ANY LOCAL SWITCHES." | | | | | | THE EXCEPTION DOES NOT APPLY, THERE IS | | | ONLY ONE CIRCUIT IN THE STORAGE ROOM. | | | | | | 2} THE NOTE REGARDING THE 2005 CODE, | | | "REVIEW COMMENTS", SHOULD BE CHANGED TO | | | READ 2002 NEC, THE CURRENT NEC FOR THE | | | STATE OF FLORIDA. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-05-17 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-05-17 |
Time |
16:57 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-05-17 |
Time |
16:19 |
Sent To |
|
|
| Notes |
| 2006-05-17 00:00:00 | | | | | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} THE ENGINEER SEAL IS NOT CURRENT | | | 61G15-23.001 SEALS ACCEPTABLE TO THE | | | BOARD. | | | (1) PURSUANT TO SECTION 471.025, F.S., | | | THE BOARD HEREBY ESTABLISHES AS | | | INDICATED BELOW THE FORMS OF EMBOSSING | | | IMPRESSION SEALS | | | WHICH ARE ACCEPTABLE TO THE BOARD. SAID | | | SEAL SHALL BE A MINIMUM OF 1 7/8 INCHES | | | IN DIAMETER. ALL ENGINEERS MUST BE | | | UTILIZING A SEAL | | | AS ILLUSTRATED IN THIS RULE NO LATER | | | THAN JANUARY 1, 2006. | | | | | | 2} PLEASE SEE THE EMERGENCY LIGHTS MUST | | | BE ON THE SAME CIRCUITAS RTHE LIGHTING | | | IN THE AREA PER 700.12(EE), 2002 NEC. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2006-11-22 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-11-22 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-11-22 |
Time |
14:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2006-06-28 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2006-06-28 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2006-06-28 |
Time |
10:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2006-05-25 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-05-25 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-05-25 |
Time |
13:59 |
Sent To |
|
|
| Notes |
| 2006-05-25 00:00:00 | PLAN REVIEW ONLY | | | NOT FOR PERMITTING | | | | | | | | | 1) LIFE SAFETY TO COMPLY WITH NFPA 101, | | | 2003 EDITION. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2007-02-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-07 |
Time |
16:19 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-07 |
Time |
16:19 |
Sent To |
|
|
| Notes |
| 2007-02-18 16:22:53 | TO COMM BAORD #29 | | 2007-02-07 16:19:48 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-11-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-11-30 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-11-30 |
Time |
11:06 |
Sent To |
|
|
| Notes |
| 2006-12-10 08:33:54 | TO COMM BAORD #64 | | 2006-11-30 11:07:57 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-10-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-10-25 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-10-25 |
Time |
09:23 |
Sent To |
|
|
| Notes |
| 2006-10-26 13:15:13 | TO "COMM" BD#29 | | 2006-10-25 09:25:54 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-07-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-07-22 |
Time |
12:12 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-07-22 |
Time |
12:12 |
Sent To |
E |
|
| Notes |
| 2006-07-22 00:00:00 | TO "E" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-06-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-21 |
Time |
11:11 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-21 |
Time |
11:11 |
Sent To |
|
|
| Notes |
| 2006-06-21 00:00:00 | TO "BOB"#15 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-06-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-01 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-15 |
Time |
14:40 |
Sent To |
|
|
| Notes |
| 2006-05-15 00:00:00 | TO "BOB"#5 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
N |
Date |
2007-02-20 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-02-20 |
Time |
16:44 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2007-02-20 |
Time |
16:44 |
Sent To |
|
|
| Notes |
| 2007-02-20 16:45:43 | NO MECHANICAL WORK TO BE DONE, MECH. PERMIT # 06100828 | | | HAS BEEN VOIDED. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2006-12-12 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-12-12 |
Time |
14:07 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-12-12 |
Time |
14:07 |
Sent To |
|
|
| Notes |
| 2006-12-12 14:14:08 | *** DENIED *** | | | 1) PLANS PAGES ME-1.0, ME-2.0, AND ME-3.0 SHOW NO | | | MECHANICAL WORK TO BE DONE THAT REQUIRES A MECHANICAL | | | PERMIT. PLEASE SUBMIT MECHANICAL PLANS FOR REVIEW OR IF | | | NO MECHANICALWORK THAT REQUIRES A PERMIT IS TO BE | | | DONE, PLEASE VOID YOUR MECHANICAL PERMIT #06100828. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2006-10-31 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-10-31 |
Time |
09:41 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-10-31 |
Time |
09:41 |
Sent To |
|
|
| Notes |
| 2006-10-31 09:46:03 | *** DENIED *** | | | 1) NO MECHANICAL PLANS WERE SUBMITTED FOR REVIEW. | | | MECHANICAL PERMIT # 06100828 WAS APPLIED FOR PLEASE | | | SUBMIT MECHANICAL PLANS FOR REVIEW, PER 2004 FBC/ WPB | | | AMEND. 106.3.5.1.4. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-10-31 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-05-15 |
Time |
15:19 |
Rev Time |
0.15 |
| Received By |
tgordon |
Date |
2006-05-15 |
Time |
15:19 |
Sent To |
|
|
| Notes |
| 2006-05-15 00:00:00 | NO MECHANICAL PLANS SUBMITTED FOR | | | REVIEW. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
N |
Date |
2007-03-10 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-03-10 |
Time |
07:39 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-03-10 |
Time |
07:39 |
Sent To |
|
|
| Notes |
| 2007-03-10 07:40:04 | NO PLUMBING WORK SHOWN ON PLANS, |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2006-11-02 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-11-02 |
Time |
07:57 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-11-02 |
Time |
07:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
N |
Date |
2006-06-23 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-06-23 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-06-23 |
Time |
09:52 |
Sent To |
|
|
| Notes |
| 2006-06-23 00:00:00 | NO PLUMBING WORK SHOWN ON PLANS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2006-06-01 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-06-01 |
Time |
09:10 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-06-01 |
Time |
09:10 |
Sent To |
|
|
| Notes |
|
|