| Plan Review Stops For Permit 06050213 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2007-05-21 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2007-05-21 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2007-05-21 |
Time |
11:20 |
Sent To |
|
|
| Notes |
| 2007-05-21 11:20:57 | FOUNDATION REVISION. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2006-11-17 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-11-17 |
Time |
09:24 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-11-17 |
Time |
09:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-09-26 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-09-26 |
Time |
09:02 |
Rev Time |
1.50 |
| Received By |
alange |
Date |
2006-09-26 |
Time |
09:02 |
Sent To |
|
|
| Notes |
| 2006-09-26 00:00:00 | DENIED | | | | | | | | | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT | | | SHALL BE RECORDED AT PALM BEACH COUNTY | | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | | BLANK FORMS ARE AVAILABLE FROM THIS | | | OFFICE. | | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE | | | RE-RECORDED IF THE DESCRIBED IMPROVEMENT | | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | | 90 DAYS OF RECORDING. | | | | | | 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 3.BASED ON ICC BUILDING VALUATION DATA | | | THE PERMIT VALUE HAS BEEN REVISED TO | | | $73,382.ADDITIONAL PERMIT FEES ARE | | | DUE. | | | | | | | | | ART LANGE | | | CONSTRUCTION SERVICES DEPARTMENT | | | BUILDING PLANS EXAMINER | | | 561-805-6672 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-06-09 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-06-09 |
Time |
08:20 |
Rev Time |
2.00 |
| Received By |
alange |
Date |
2006-06-09 |
Time |
08:20 |
Sent To |
|
|
| Notes |
| 2006-06-09 00:00:00 | DENIED | | | | | | | | | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT | | | SHALL BE RECORDED AT PALM BEACH COUNTY | | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | | BLANK FORMS ARE AVAILABLE FROM THIS | | | OFFICE. | | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE | | | RE-RECORDED IF THE DESCRIBED IMPROVEMENT | | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | | 90 DAYS OF RECORDING. | | | | | | 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 3.BASED ON ICC BUILDING VALUATION DATA | | | THE PERMIT VALUE HAS BEEN REVISED TO | | | $73,382.ADDITIONAL PERMIT FEES ARE | | | DUE. | | | | | | 4.PRODUCT APPROVALS REQUIRED FOR ALL | | | EXTERIOR DOORS, WINDOWS, IMPACT | | | PROTECTION, ROOFING, STRAPS AND TIE | | | DOWNS AND LINTELS IN USED. | | | | | | 5.ALL PRODUCT APPROVALS SUBMITTED WITH | | | QUALITY ASSURANCE SHALL HAVE THE | | | FOLLOWING STATE APPROVAL ATTACHED. | | | | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A STATE PRODUCT APPROVAL | | | SHEETS THAT LISTS THE PRODUCT IDENTITY | | | NUMBER FROM THE STATE. IF THE PRODUCT | | | DOES NOT HAVE STATEWIDE APPROVAL, SUBMIT | | | AN APPLICATION FOR LOCAL PRODUCT | | | APPROVAL OR SITE SPECIFIC FORM PER RULE | | | 9B-72. SEE ATTACHMENT. | | | WWW.FLORIDABUILDING.ORG | | | | | | 6.THOSE PRODUCT APPROVALS WHICH ARE | | | REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL | | | FOR JURISDICTIONAL APPROVAL.WPB | | | AMENDMENT TO FBC 106.3.3. | | | | | | 7.SUBMIT TWO SETS OF TRUSS DRAWINGS | | | FOR REVIEW PER 2004 FBC R-802.10.1 | | | | | | 8.A DESIGN PROFESSIONAL OR AN OWNER | | | MUST ELECT ONE OR A COMBINATION OF | | | LEVELS OF ALTERATION PURSUANT TO | | | SECTIONS 303, 304 AND 305 OF THIS CODE. | | | SHOW HOW PLANS WILL COMPLY WITH THE | | | SECTION(S) SELECTED.2004 FBC EXISTING | | | BUILDING 301.5 | | | | | | 9.ARCHITECTS SEAL AND SIGNATURE NOT ON | | | ALL PAGES. | | | | | | 10.R401.3 DRAINAGE. | | | SURFACE DRAINAGE SHALL BE DIVERTED TO A | | | STORM SEWER CONVEYANCE OR OTHER APPROVED | | | POINT OF COLLECTION SO AS TO NOT CREATE | | | A HAZARD. LOTS SHALL BE GRADED SO AS TO | | | DRAIN SURFACE WATER AWAY FROM FOUNDATION | | | WALLS. THE GRADE AWAY FROM FOUNDATION | | | WALLS SHALL FALL A MINIMUM OF 6 INCHES | | | WITHIN THE FIRST 10 FEET. | | | | | | 11.R403.1.4 MINIMUM DEPTH. | | | ALL EXTERIOR FOOTINGS SHALL BE PLACED AT | | | LEAST 12 INCHES BELOW THE UNDISTURBED | | | GROUND SURFACE. | | | | | | | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. SUBMIT ONE COPY OF | | | OLD PAGES FOR REFERENCE. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET | | | OR SPECIFICATION PAGE WHERE THE CHANGES | | | CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | ART LANGE | | | CONSTRUCTION SERVICES DEPARTMENT | | | BUILDING PLANS EXAMINER | | | 561-805-6672 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2006-12-21 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-12-21 |
Time |
10:27 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-12-20 |
Time |
18:13 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2006-11-16 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-11-16 |
Time |
07:15 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-11-15 |
Time |
17:24 |
Sent To |
M |
|
| Notes |
| 2006-11-16 07:15:36 | | | | | | | | | | | | | NONCOMPLIANT | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} THE ENGINEERING FIRM SHALL INDICATE | | | THE CERTIFICATE OF AUTHORIZATIONNUMBER | | | ALONG WITH OTHER INFORMATION REQUIRED BY 61G15-23.002 | | | FLORIDA ADMINISTRATIVE | | | CODE | | | | | | 2} THE BATH CIRCUIT REQUIRED BY 210.11(C)(3) DOES NOT | | | APPEAR ON THE PANEL SCHEDULE. PLEASE INCLUDE. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW. | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-09-11 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-09-11 |
Time |
09:58 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2006-09-11 |
Time |
07:25 |
Sent To |
M |
|
| Notes |
| 2006-09-11 00:00:00 | | | | | | | | | | | | | NONCOMPLIANT | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} THE ENGINEERING FIRM SHALL INDICATE | | | THE CERTIFICATE OF AUTHORIZATIONNUMBER | | | ALONG WITH OTHER INFORMATION REQUIRED BY 61G15-23.002 | | | FLORIDA ADMINISTRATIVE | | | CODE. | | | | | | 2} SHEET SP-1 INDICATES THE EXISTING A/C | | | UNIT TO REMAIN AND ADDING A/C-2. THERE | | | IS ONLY ONE SYSTEM ON THE ELECTRICAL | | | PLAN, PLEASE CLARIFY, CORRECT THE PANEL | | | SCHEDULE AND LOAD CALCS IF NECESSARY. | | | | | | 3} THE DRYER CIRCUIT INDICATES A #12 | | | CONDUCTOR ON THE 25 AMP BREAKER. THE | | | CONDUCTOR MUST BE #10 TO COMPLY WITH | | | 240.4(D). | | | | | | 4} RESEPTACLES MUST BE ADDED IN THE | | | DINING AND MASTER BED ROOMS PER 210.52. | | | | | | 5} PLEASE PROVIDE A PANEL SCHEDULE SO | | | THAT BRANCH/FEEDER CIRCUIT CONDUCTOR AND | | | OVER CURRENT PROTECTION COMPLIANCE MAY | | | BE REVIEWED. | | | NOTE: A LOAD CALCULATION AND PANEL | | | SCHEDULE ARE REQUIRED PER 106.3.5.4, FBC | | | AS AMENDED. | | | | | | 6} TWO COMPLETE SETS OF DOCUMENTS ARE | | | REQUIRED TO BE SUBMITTED FOR REVIEW PER | | | 106.1 FBC, AS AMENDED. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-05-26 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-05-26 |
Time |
12:52 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-05-26 |
Time |
12:11 |
Sent To |
P |
|
| Notes |
| 2006-05-26 00:00:00 | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} PLEASE PROVIDE A PANEL SCHEDULE SO | | | THAT BRANCH/FEEDER CIRCUIT CONDUCTOR AND | | | OVER CURRENT PROTECTION COMPLIANCE MAY | | | BE REVIEWED. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
5 |
Status |
P |
Date |
2007-01-25 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-01-25 |
Time |
14:05 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2007-01-25 |
Time |
14:05 |
Sent To |
Z |
|
| Notes |
| 2007-01-25 14:16:49 | NOTE: SEPERATE GAS PERMIT REQUIRED |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
4 |
Status |
F |
Date |
2006-12-27 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-12-27 |
Time |
09:48 |
Rev Time |
0.45 |
| Received By |
mperson |
Date |
2006-12-27 |
Time |
09:48 |
Sent To |
M |
|
| Notes |
| 2006-12-27 09:54:11 | DENIED 4TH TIME | | | REFERENCE: FBC-2004 FUEL GAS | | | | | | THE FOLLOWING CORRECTIONS ARE REQUIRED ON THE | | | RESUBMITTED DRAWINGS TO MEET CODE COMPLIANCE: | | | | | | 1. PLEASE REFERENCE PLUMBING COMMENTS NUMBERS 5 AND 7 | | | FOR THE RESUBMITTAL. | | | | | | 2. SHEETS P-1 AND E-1 INDICATE AN ELECTRIC DRYER AND | | | SHEET P-2 INDICATES A GAS DRYER, THIS IS CONFUSING, | | | PLEASE CORRELATE THE DRAWINGS ON THE RESUBMITTAL. | | | PLEASE NOTE IF THERE IS TO BE A GAS DRYER IT ALSO NEEDS | | | TO BE ADDED TO THE GAS RISER DIAGRAM ON SHEET P-1. | | | | | | 3. SHEET P-1 GAS RISER DIAGRAM STATES IN CLOUDED AREA | | | "APPROXIMATE DISTANCE OF 25' FROM METER TO NEW SERVICE | | | ENTRANCE" AND THERE APPEARS TO BE A NATURAL GAS METER | | | INDICATED ON THE RISER DIAGRAM, THIS IS CONFUSING, | | | PLEASE INDICATE ON THE RESUBMITTED GAS RISER DIAGRAM | | | ONLY ONE NATURAL GAS METER AND DELETE ALL OTHERS. | | | | | | **IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING, | | | PLEASE REPLACE ONLY SHEETS | | | WHICH HAVE CHANGED, PLEASE INCLUDE A | | | TRANSMITTAL LETTER INDICATING HOW EACH | | | ITEM WAS ADDRESSED AND PROVIDE ONE COPY | | | OF ALL OLD/VOIDED SHEETS FOR REFERENCE | | | ONLY. NOTE: ONLY ONE CORRECTED DRAWING | | | IN RED INK FOR REFERENCE FOR | | | RESUBMITTAL. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
F |
Date |
2006-11-27 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-11-27 |
Time |
13:19 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2006-11-27 |
Time |
13:19 |
Sent To |
B |
|
| Notes |
| 2006-11-27 14:29:13 | UNSAT 3RD TIME | | | REFERENCE: FBC-2004 FUEL GAS | | | | | | THE FOLLOWING CORRECTIONS ARE REQUIRED FOR GAS PLAN | | | REVIEW TO MEET CODE COMPLIANCE: | | | | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2004 | | | FUEL GAS CODE. | | | NOTE: NOT ALL CUT SECTIONS OF PIPE HAVE CORRESPONDING | | | LENGTHS INDICATED. | | | | | | 2. PLEASE NOTE THAT THE INDICATED MATERIAL ON SHEET P-1 | | | IS SCH. 40 BLK STEEL PIPE, WITH A TOTAL DEVELOPED | | | LENGTH OF OVER 30' WHEN ALL CUT SECTIONS OF PIPE ARE | | | ACCOUNTED FOR AND A TOTAL BTU LOAD OF 96,000 NOT | | | 121,000 AS THE DRAWING INDICATES. PER FBC-2004 FUEL | | | GAS, TABLE 402.4 (2)GAS SYSTEM IS SIZED WRONG, PLEASE | | | REFERENCE THE CORRECTED GAS RISER AND TOTAL BTU LOAD IN | | | RED FOR THE RESUBMITTAL. | | | | | | 3. PER FBC-2004 FUEL GAS SECTION 404.11 PIPING | | | UNDERGROUND BENEATH BILDING. PLEASE PROVIDE A DETAIL OF | | | THIS INSTALLATION. | | | NOTE: AS AN ALTERNATIVE IT IS SUGGESTED TO PIPE GAS | | | OVERHEAD INSTEAD OF UNDERGROUND. | | | | | | 4. PLEASE INDICATE ON THE RESUBMITTAL COMPLIANCE WITH | | | FBC-2004 FUEL GAS, SECTIONS 404.8 AND 404.8.1 | | | PROTECTION AGAINST CORROSION. | | | | | | **IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING, | | | PLEASE REPLACE ONLY SHEETS | | | WHICH HAVE CHANGED AND PROVIDE ONE COPY | | | OF ALL OLD/VOIDED SHEETS FOR REFERENCE | | | ONLY. NOTE: ONLY ONE CORRECTED DRAWING | | | IN RED INK FOR REFERENCE FOR | | | RESUBMITTAL. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 | | | | | | | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2006-09-23 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-09-23 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-09-23 |
Time |
13:44 |
Sent To |
P |
|
| Notes |
| 2006-09-23 00:00:00 | GAS REVIEW DENIED; | | | 1.TYPE OF PIPING MATERIAL NOT ON PLAN. | | | IS GAS PIPE MOUNTED ON WALL, RUN IN | | | ATTIC OR UNDER GROUND? | | | 2.GAS ISOMETRIC SHOWS 2 APPLIANCES, W/H | | | AND STOVE, FLOOR PLAN SHOWS DRIER IS GAS | | | ALSO. PLEASE CLARIFY. | | | 3.GAS PIPE TO BE SLEEVED IF RUN THRU | | | WALL SHOW ON PLANS. | | | GAS PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2006-06-05 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-06-05 |
Time |
14:23 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-06-05 |
Time |
14:23 |
Sent To |
M |
|
| Notes |
| 2006-06-05 00:00:00 | 1. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2004 | | | FUEL GAS CODE. | | | 2. SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE BEING USED. | | | 3. TYPE OF GAS, (LP OR NATURAL) | | | 4. INDICATE THE DELIVERY PRESSURE (PSI) | | | PER FBC-2004 FUEL GAS CODE SEC. 402.2. | | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. | | | GAS PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2008-03-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-03-11 |
Time |
10:24 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-03-11 |
Time |
10:24 |
Sent To |
M |
|
| Notes |
| 2008-03-11 10:24:53 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2008-02-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-02-08 |
Time |
16:44 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-02-08 |
Time |
16:44 |
Sent To |
M |
|
| Notes |
| 2008-02-08 16:44:18 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2007-01-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-01-20 |
Time |
12:51 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-01-20 |
Time |
12:51 |
Sent To |
Z |
|
| Notes |
| 2007-01-20 12:51:31 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-11-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-11-08 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-11-08 |
Time |
14:01 |
Sent To |
E |
|
| Notes |
| 2006-11-08 14:01:49 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-10-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-10-26 |
Time |
14:07 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-10-26 |
Time |
14:07 |
Sent To |
Z |
|
| Notes |
| 2006-10-26 14:07:40 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-09-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-05 |
Time |
09:44 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-05 |
Time |
09:44 |
Sent To |
E |
|
| Notes |
| 2006-09-05 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-08-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-26 |
Time |
15:18 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-26 |
Time |
15:18 |
Sent To |
Z |
|
| Notes |
| 2006-08-26 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-05-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-22 |
Time |
15:47 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-22 |
Time |
15:47 |
Sent To |
E |
|
| Notes |
| 2006-05-22 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-06-09 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-06-09 |
Time |
08:20 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-05-05 |
Time |
13:20 |
Sent To |
|
|
| Notes |
| 2006-05-05 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
7 |
Status |
P |
Date |
2008-03-11 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-03-11 |
Time |
11:16 |
Rev Time |
0.35 |
| Received By |
tgordon |
Date |
2008-03-11 |
Time |
11:16 |
Sent To |
|
|
| Notes |
| 2008-03-11 11:17:03 | REVISION TO MECH. PLAN. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
F |
Date |
2008-02-11 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-02-11 |
Time |
10:29 |
Rev Time |
0.40 |
| Received By |
tgordon |
Date |
2008-02-11 |
Time |
10:29 |
Sent To |
|
|
| Notes |
| 2008-02-11 10:59:40 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | ** REVISION TO MECHANICAL PLAN ** | | | *** DENIED *** | | | 1) PLEASE SUBMIT A NEW LETTER FROM THE ENGINEER WITH | | | THE JOB ADDRESS AND PERMIT NUMBER 06050213 ON IT. | | | | | | 2) PROVIDE COMBUSTION AIR OR MAKE UP AIR FOR THE GAS | | | WATER HEATER IN THE LAUNDRY ROOM, SEE 2004 FBC/R | | | G2407.1 AND G2407.4. | | | | | | 3) PROVIDE FOR RETURN AIR IN THE NEW MASTER SUITE, SEE | | | 2004 FBC/R M1602.4. | | | | | | 4) SHOW THE CFM'S AT ALL NEW SUPPLY AIR GRILLS ON | | | MECHANICAL PLAN, SEE 2004 WPB AMEND. 106.3.5.4 (10). | | | | | | 5) SHOW WERE THE CLOTHES DRYER VENT WILL TERMINATE AT | | | ON THE MECHANICAL PLAN, SEE 2004 FBC/R M303.4.2. | | | | | | 6) SHOW ANY NEW BATHROOM EXHAUST FANS BEING INSTALLED, | | | ON THE MECHANICALPLAN, SEE 2004 FBC/R R303.3. | | | | | | 7) SHOW THE HEATER KW IN THE A/C EQUIPMENT SCHEDULE, | | | SEE 2004 WPB AMEND. 106.3.5.4 (10). | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2007-01-24 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-01-24 |
Time |
12:10 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-01-24 |
Time |
12:09 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2006-12-27 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-12-27 |
Time |
14:35 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2006-12-27 |
Time |
14:35 |
Sent To |
|
|
| Notes |
| 2006-12-27 14:46:41 | *** DENIED *** | | | 1) MANUAL N CAL'S ARE SHOWING ON PAGE 6, 1870 SQ. FT. | | | AREA. PLANS ARE SHOWING 1534 SQ. FT. AREA, PLEASE | | | CORRECT MANUAL N CAL'S.. | | | | | | 2) 12" RETURN AIR TRANSFER GRILL TO MASTER BEDROOM | | | SUITE NEEDS TO BE 16". | | | BALANCED RETURN AIR MAY BE ACHIEVED BY. | | | (A)TRANSFER DUCTS MAY ACHIEVE THIS BY | | | INCREASING THE RETURN TRANSFER ONE AND | | | ONE HALF TIMES THE CROSS SECTIONAL AREA | | | (SQUARE INCHES) OF THE SUPPLY DUCT | | | ENTERING THE ROOM OR SPACE IT'S SERVING | | | AND THE DOOR HAVING AT LEAST AN | | | UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE | | | PROPER RETURN AIR BALANCE. | | | (C)HABITABLE ROOMS ONLY SHALL BE | | | REQUIRED TO MEET THESE REQUIREMENTS FOR | | | PROPER BALANCED RETURN AIR EXCLUDING | | | BATHROOMS, CLOSETS, STORAGE ROOMS AND | | | LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY | | | AIR INTO THE MASTER SUITE SHALL BE | | | INCLUDED. PER 2004 FBC/R M1602.4 . | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2006-11-16 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-11-16 |
Time |
09:00 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2006-11-16 |
Time |
09:00 |
Sent To |
P |
|
| Notes |
| 2006-11-16 09:07:04 | *** DENIED *** | | | 1) AS NOTED IN LAST TWO REVIEWS 6-5-06 NOTE #2 AND | | | 9-12-06 NOTE #1 PLEASE CORRECT ENERGY CALCULATIONS, | | | ENERGY CALCULATIONS SHOW 1960 SQ. FT. UNDER AIR, PLANS | | | ARE SHOWING ONLY 1534 SQ. FT. UNDER AIR. | | | | | | 2) AS NOTED IN LAST REVIEW 9-12-06 NOTE #5, SEE PAGE | | | SP-1, D-1, A-1, S-2 ARE SHOWING EXISTING CU-1 CONDENSER | | | UNIT TO REMAIN, WERE PAGE E-1 SHOWS EXIST. CU-1 TO BE | | | REPLACED, PLEASE CORRECT. | | | | | | 3) THEIR ARE NO MANUAL J CALCULATIONS WITH THE PLANS AT | | | THIS TIME. PLEASE SUBMITMANUAL J CALCULATIONS, PER | | | 2004 FBC 13-607.1.ABC.1 . | | | | | | 4) SEE PLANS PAGE M-4 MISSING ENGINEER'S PRINTED NAME | | | MUST APPEAR IN THE TITLE BLOCK, ALSO THE ENGINEERING | | | BUSINESS'S CERTIFICATE OF AUTHORIZATION NUMBER, PER FAC | | | 61G15-23.002 . | | | | | | 5)SEE ATTACHED NOTICE FS 553.80(2)(B) REGARDING FOUR | | | TIMES THE FEE. THIS IS ONLY A NOTICE AT THIS TIME. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2006-09-12 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-09-12 |
Time |
08:16 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2006-09-12 |
Time |
08:16 |
Sent To |
P |
|
| Notes |
| 2006-09-12 00:00:00 | *** DENIED *** | | | 1) AS NOTED IN LAST REVIEW 6-5-06 #2. | | | PLEASE MAKE CORRECTIONS TO ENERGY | | | CALCULATIONS, SEE CONDITIONED FLOOR | | | AREA, HOT WATER SYSTEM, AND HVAC | | | CREDITS. SAME ENERGY CAL'S. WERE | | | RESUBMITTED. | | | | | | 2) AS NOTED IN LAST REVIEW 6-5-06 #6. | | | ALL RETURN AIR TRANSFER DUCTS ARE TO | | | SMALL. RETURN AIR TRANSFER DUCTS NEED TO | | | BE 1 1/2 TIMES THE CROSS SECTIONAL AREA | | | (SQUARE INCHES) OF THE SUPPLY DUCTS | | | ENTERING THE ROOM. THE MASTER SUITE MUST | | | INCLUDE THE BATHROOM AND CLOSET. PER | | | 2004 FBC/R M1602.4 . | | | | | | 3) CLOTHES DRYER VENTS CAN NOT HAVE | | | SCREENS IN THEM, PER 2004 FBC/R M1501.1, | | | PLEASE CORRECT. | | | | | | 4) THE CLOTHES DRYER VENT AND THE GAS | | | WATER HEATER VENT CAN NOT DISCHARGE TO | | | THE COVERED PORCH, PER 2004 FBC/M 501.2, | | | PLEASE CORRECT. | | | | | | 5) SEE PAGE SP-1, D-1, A-1, S-2 ARE | | | SHOWING EXISTING CU-1 CONDENSER UNIT TO | | | REMAIN, WERE PAGE E-1 SHOWS EXIST. CU-1 | | | TO BE REPLACED, PLEASE CORRECT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-06-05 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-06-05 |
Time |
16:38 |
Rev Time |
1.15 |
| Received By |
tgordon |
Date |
2006-06-05 |
Time |
16:38 |
Sent To |
B |
|
| Notes |
| 2006-06-05 00:00:00 | *** DENIED *** | | | 1) ENGINEER'S PRINTED NAME MUST APPEAR | | | IN THE TITLE BLOCK, ALSO THE ENGINEERING BUSINESS'S | | | CERTIFICATE OF AUTHORIZATION | | | NUMBER, PER FAC 61G15-23.002 . | | | | | | 2) PLEASE MAKE CORRECTIONS TO ENERGY | | | CALCULATIONS, SEE CONDITIONED FLOOR | | | AREA, HOT WATER SYSTEM, AND HVAC | | | CREDITS. | | | | | | 3) PROVIED COMBUSTION AIR FOR GAS WATER | | | HEATER AND GAS CLOTHES DRYER, PER 2004 | | | FBC/R M1701.1 . | | | | | | 4) PLEASE SUBMIT A MANUAL 'D' | | | CALCULATION (RESIDENTIAL DUCT DESIGN), | | | PER 2004 FBC/R M1601.1 . | | | | | | 5) RETURN AIR GRILL 20" X 20" WITH A | | | FILTER IS TO SMALL FOR A 4 TON SYSTEM, | | | PLEASE CORRECT. | | | | | | 6) ALL THE RETURN AIR TRANSFER GRILLS | | | ARE TO SMALL, SEE NOTE #7. | | | | | | 7) BALANCED RETURN AIR. | | | THIS MAY BE ACHIEVED BY. | | | (A)TRANSFER DUCTS MAY ACHIEVE THIS BY | | | INCREASING THE RETURN TRANSFER ONE AND | | | ONE HALF TIMES THE CROSS SECTIONAL AREA | | | (SQUARE INCHES) OF THE SUPPLY DUCT | | | ENTERING THE ROOM OR SPACE IT'S SERVING | | | AND THE DOOR HAVING AT LEAST AN | | | UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE | | | PROPER RETURN AIR BALANCE. | | | (B)TRANSFER GRILLES SHALL USE 50 | | | SQUARE INCHES (OF GRILLE AREA) TO 100 | | | CFM (OF SUPPLY AIR) FOR SIZING | | | THROUGH-THE-WALL TRANSFER GRILLES AND | | | USING AN UNRESTRICTED 1-INCH | | | UNDERCUTTING OF DOORS TO ACHIEVE PROPER | | | RETURN AIR BALANCE | | | (C)HABITABLE ROOMS ONLY SHALL BE | | | REQUIRED TO MEET THESE REQUIREMENTS FOR | | | PROPER BALANCED RETURN AIR EXCLUDING | | | BATHROOMS, CLOSETS, STORAGE ROOMS AND | | | LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY | | | AIR INTO THE MASTER SUITE SHALL BE | | | INCLUDED. PER 2004 FBC/R M1602.4 . | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2007-01-25 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-01-25 |
Time |
13:35 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2007-01-25 |
Time |
13:35 |
Sent To |
G |
|
| Notes |
| 2007-01-25 13:43:04 | ****************PROVISO**************** | | | PER FBC-2004 PLUMBING, SECTION 708.9 . ACCESS SHALL | | | BE | | | PROVIDED TO ALL CLEANOUTS. CLEANOUT FOR WASHING MACHINE | | | TO BE FOUR FEET ABOVE FINNISH FLOOR |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2006-12-27 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-12-27 |
Time |
08:13 |
Rev Time |
1.50 |
| Received By |
mperson |
Date |
2006-12-27 |
Time |
08:13 |
Sent To |
G |
|
| Notes |
| 2006-12-27 09:45:51 | DENIED 4TH TIME | | | REFERENCE: FBC-2004 PLUMBING AND FBC-2004 CHAPTER 1 | | | | | | THE FOLLOWING CORRECTIONS ARE STILL REQUIRED FOR | | | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE, SEE | | | ATTACHED NOTICE FS 553.80(2)(B) REGUARDING FOUR (4) | | | TIMES THE FEE: | | | | | | 1. PER FBC-2004 CHAPTER 1, SECTION | | | 106.3.5.4 RESIDENTIAL (ONE AND TWO | | | FAMILY) SUBMIT A PLUMBING SANITARY | | | ISOMETRIC RISER DIAGRAM INDICATING ALL | | | WASTE, VENTS, TRAPS WITH SIZES, AND | | | CLEANOUT LOCATIONS. | | | NOTE: THE SUBMITTED SANITATY RISER DIAGRAM ON SHEET P-1 | | | STILL DOES NOT INDICATE ALL TRAP SIZES. PLEASE | | | REFERENCE THE CORRECTED SANITARY RISER DIAGRAM IN RED | | | ON SHEET P-1 FOR THE RESUBMITTAL. | | | | | | 2. THE WASHING MACHINE DRAIN INDICATED ON SHEET P-1 | | | SANITARY RISER DIAGRAM IS STILL INDICATED WRONG PER | | | FBC-2004 PLUMBING, SECTION 406.3 WASTE CONNECTIONS, | | | SECTION 802.4 STAND PIPES, SECTION 708.7 CLEANOUT | | | MINIMUM SIZE AND SECTION 708.9 CLEANOUT ACCESS, FOR | | | WASHING MACHINE CLEANOUT TO BE INDICATED AT FOUR FEET | | | ABOVE FINNISH FLOOR (4' AFF). PLEASE REFERENCE THE | | | CORRECTED SANITARY RISER DIAGRAM IN RED ON SHEET P-1 | | | FOR THE RESUBMITTAL. | | | | | | 3. THE DISHWASHER DRAIN ON SHEET P-1 SANITARY RISER | | | DIAGRAM IS STILL INDICATED WRONG PER FBC-2004 PLUMBING, | | | SECTION 802.1.6. PLEASE REFERENCE THE CORRECTED | | | SANITARY RISER DIAGRAM IN RED ON SHEET P-1 FOR THE | | | RESUBMITTAL. | | | | | | THE FOLLOWING ARE NEW ITEMS THAT NEED TO BE CORRECTED | | | TO MEET CODE COMPLIANCE: | | | | | | 4. PLEASE INDICATE ON THE RESUBMITTED DRAWINGS ON | | | SHEET P-1 THAT THE WATER-HAMMER ARRESTORS TO BE | | | INSTALLED PER FBC-2004 PLUMBING SECTION 604.9. | | | | | | 5. A} SHEET P-2, A TITLE BLOCK IS REQUIRED WITH THE | | | FOLLOWING INFORMATION: | | | FAC-61G1-16.004 TITLE BLOCK: | | | A TITLE BLOCK MUST APPEAR ON ALL | | | ARCHITECTURAL OR INTERIOR DESIGN | | | DRAWINGS AND SPECIFICATION | | | IDENTIFICATION SHEETS. THE TITLE BLOCK | | | MUST, AT A MINIMUM, CONTAIN THE | | | FOLLOWING INFORMATION: | | | (1) FIRM NAME, ADDRESS, AND TELEPHONE | | | NUMBER. | | | (2) FIRM LICENSE NUMBER. | | | (3) NAME OR IDENTIFICATION OF PROJECT. | | | (4) DATE PREPARED. | | | (5) A SPACE FOR THE SIGNATURE AND DATED | | | SEAL. | | | (6) A SPACE FOR THE PRINTED NAME OF THE | | | PERSON SEALING THE DOCUMENT. | | | NOTE: ITEMS #1 ADDRESS IS DIFFERENT, #2 AND#6 ARE | | | MISSING FROM TITLE BLOCK. | | | B} REVISED SHEET P-1 RESUBMITTAL IS INTIALED INSTEAD | | | OF BEING SIGNED, PLEASE CORRECT THIS ON THE NEXT | | | RESUBMITTAL. | | | | | | 6. SHEET P-2 WATER HEATER DETAIL A VACUUM RELIEF VALVE | | | IS REQUIRED ON A BOTTOM FED WATER HEATER PER FBC-2004, | | | SECTION 504.2. THE HEAT RECOVERY RETURN SHOULD READ | | | FUTURE AND IT SHOULD TIE INTO THE C.W. SUPPLY. PLEASE | | | REFERENCE THE CORRECTED DETAIL IN RED AND PLEASE | | | CORRECT THE WATER HEATER DETAIL TO REFLECT THIS ON THE | | | RESUBMITTAL. | | | | | | 7. PER FBC-2004 CHAPTER 1, SECTION 106.1 MINIMUM OF | | | TWO COMPLETE SETS OF DRAWINGS ARE REQUIRED, ONLY ONE | | | REVISED SHEET P-1 WAS IN THE RESUBMITTAL PACKAGE. | | | | | | **IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING, | | | PLEASE REPLACE ONLY SHEETS | | | WHICH HAVE CHANGED, PLEASE INCLUDE A | | | TRANSMITTAL LETTER INDICATING HOW EACH | | | ITEM WAS ADDRESSED AND PROVIDE ONE COPY | | | OF ALL OLD/VOIDED SHEETS FOR REFERENCE | | | ONLY. NOTE: ONLY ONE CORRECTED DRAWING | | | IN RED INK FOR REFERENCE FOR | | | RESUBMITTAL. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 | | | | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2006-11-27 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-11-27 |
Time |
11:41 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2006-11-27 |
Time |
11:41 |
Sent To |
G |
|
| Notes |
| 2006-11-27 13:17:23 | UNSAT 3RD TIME | | | REFERENCE: FBC-2004 PLUMBING AND FBC-2004 CHAPTER 1 | | | | | | THE FOLLOWING CORRECTIONS ARE REQUIRED FOR PLUMBING | | | PLAN REVIEW TO MEET CODE COMPLIANCE: | | | | | | 1. PER FBC-2004 CHAPTER 1, SECTION 106.3.5.4 | | | RESIDENTIAL (ONE AND TWO | | | FAMILY) SUBMIT A PLUMBING SANITARY | | | ISOMETRIC RISER DIAGRAM INDICATING ALL | | | WASTE, VENTS, TRAPS WITH SIZES, AND | | | CLEANOUT LOCATIONS. PLEASE SIZE THESANITARY PLUMBING | | | RISER ON SHEET P-1 PER FBC-2004 PLUMBING, TABLE 709.1. | | | | | | 2. THE WASHING MACHINE DRAIN INDICATED ON SHEET P-1 | | | SANITARY PLUMBING RISER IS INDICATED WRONG PER THE | | | FOLLOWING FBC-2004 PLUMBING SECTIONS. | | | (A) 406.3 WASTE CONNECTIONS.THE TRAP AND | | | FIXTURE DRAIN FOR AN AUTOMATIC CLOTHES | | | WASHER SHALL BE A MINIMUM OF 2 INCHES | | | (51MM) IN DIAMETER. THE AUTOMATIC | | | CLOTHES WASHER FIXTURE DRAIN SHALL | | | CONNECT TO A BRANCH DRAIN OR DRAINAGE | | | STACK A MINIMUM OF 3 INCHES (76MM) IN | | | DIAMETER. PLEASE INDICATE PIPE SIZE ON THE | | | RESUBMITTAL. | | | (B) 802.4 STANDPIPES.STANDPIPES SHALL BE INDIVIDUALLY | | | TRAPPED. STANDPIPES SHALL | | | EXTEND A MINIMUM OF 18 INCHES (457MM) | | | AND A MAXIMUM OF 42 INCHES (1066MM) | | | ABOVE THE TRAP WEIR. ACCESS SHALL BE | | | PROVIDED TO ALL STANDPIPES AND DRAINS | | | FOR RODDING. PLEASE INDICATE THE STANDPIPE ON THE | | | RESUBMITTAL. | | | | | | 3. THE DISHWASHER DRAIN ON SHEET P-1 SANITARY PLUMBING | | | RISER IS INDICATED WRONG PER FBC-2004 PLUMBING, SECTION | | | 802.1.6. THE DISHWASHER SHALL DISCHARGE INTO A | | | WYE-BRANCH FITTING ON THE TAILPIECE OF THE KITCHEN SINK | | | OR THE DISHWASHER CONNECTION OF A FOOD WASTE GRINDER. | | | PLEASE REFERENCE THE CORRECTED DRAWING ON SHEET P-1 FOR | | | THE RESUBMITTAL. | | | | | | **IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING, | | | PLEASE REPLACE ONLY SHEETS | | | WHICH HAVE CHANGED AND PROVIDE ONE COPY | | | OF ALL OLD/VOIDED SHEETS FOR REFERENCE | | | ONLY. NOTE: ONLY ONE CORRECTED DRAWING | | | IN RED INK FOR REFERENCE FOR | | | RESUBMITTAL. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2006-09-23 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-09-23 |
Time |
14:03 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-09-23 |
Time |
14:03 |
Sent To |
B |
|
| Notes |
| 2006-09-23 00:00:00 | DENIED; | | | 1. TWO SETS OF PLANS ARE REQUIRED. | | | 2. RISER DIAGRAM; SHOWER NOT VENTED AS | | | DRAWN, LAVATORY VENT TO BE BETWEEN W/C | | | AND SHOWER. SEE P-1 MARKED IN RED. | | | PLEASE MAKE CORRECTIONS. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-06-05 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-06-05 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-06-05 |
Time |
14:01 |
Sent To |
M |
|
| Notes |
| 2006-06-05 00:00:00 | DENIED; | | | SANITARY RISER DIAGRAM; | | | AUTOMATIC CLOTHES WASHER IS REQUIRED | | | DISCHARGE INDIRECTLY INTO A STANDPIPE A | | | MINIMUM OF 18" NOT INTO A FLOOR DRAIN, | | | SEE FBC-2004 PLUMBING SEC.802.4. | | | 2.W/M AND KITCHEN SINK SHALL NOT DRAIN | | | INTO THE WET VENT OF A BATHROOM GROUP. | | | SEC. 909.1. | | | 3.BRANCH DRAIN FOR W/M SHALL BE 3", SEC. | | | 406.3 | | | WATER RISER DIAGRAM; | | | 1.WATER HAMMER ARRESTORS ARE REQUIRED | | | PER SEC. 604.9 | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2006-11-06 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-11-06 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-11-06 |
Time |
11:19 |
Sent To |
I |
|
| Notes |
| 2006-11-06 11:20:02 | PROVISO: THE PROPOSED ADDITION MUST SIT BEYOND THE 25FT | | | FRONT SETBACK.ALSO, MUST HAVE INTERIOR ACCESS | | | THROUGH-OUT THE STRUCTURE. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2006-09-02 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-09-02 |
Time |
09:05 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-09-02 |
Time |
09:05 |
Sent To |
I |
|
| Notes |
| 2006-09-02 00:00:00 | DENIED, | | | 1. ONLY ONE SET OF PLANS WERE SUBMITTED. | | | 2.NEED TO SUBMIT ANOTHER SET PLANS FOR | | | STAMPING, ONE COPY IS FOR OFFICE FILE | | | AND THE OTHER IS FOR THE CONTRACTOR. | | | | | | PROVISO: THE PROPOSED ADDITION AND | | | EXSITING GARAGE MUST MEET THE 25FT FRONT | | | SETBACK AS REQUIRED BY ZONING & LAND | | | DEVELOPMENT REGULATIONS. | | | | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2006-05-22 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-05-22 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-05-22 |
Time |
11:42 |
Sent To |
I |
|
| Notes |
| 2006-05-22 00:00:00 | DENIED, | | | 1. THE PROPOSED BATH MUST SIT BEYOND THE | | | 25FT FRONT SETBACK. | | | 2. THE EXISTING STRUCTURE ONLY SITS | | | 24'-103/3" AND DOES NOT MEET THE CURRENT | | | REQUIREMENT FOR THE FRONT SETBACK WHICH | | | IS 25FT, SO ANY PORPOSED ADDITION MUST | | | MEET THAT REQUIRED SETBACK. | | | 3. MUST PROVIDE A COPY OF CURRENT | | | SURVEY. | | | | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|