| Plan Review Stops For Permit 06050177 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2006-06-12 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-06-12 |
Time |
11:42 |
Rev Time |
0.50 |
| Received By |
alange |
Date |
2006-06-12 |
Time |
11:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-09-08 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2006-09-07 |
Time |
06:26 |
Rev Time |
0.45 |
| Received By |
jleahy |
Date |
2006-09-07 |
Time |
06:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-07-25 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2006-07-25 |
Time |
14:16 |
Rev Time |
0.39 |
| Received By |
jleahy |
Date |
2006-07-25 |
Time |
14:16 |
Sent To |
B |
|
| Notes |
| 2006-07-25 00:00:00 | SPECS FOR TRANSFER SWITCH IS NOT WHAT IS | | | SHOWN ON DRAWINGS. | | | | | | DRAWINGS SHOW TRANSFER SWITCH PANEL | | | COMBO | | | | | | JAKE LEAHY |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-06-05 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-06-05 |
Time |
14:22 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-06-05 |
Time |
13:53 |
Sent To |
P |
|
| Notes |
| 2006-06-05 00:00:00 | | | | NONCOMPLIANT | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | THE PERSON TAKING RESPONSIBILITY FOR THE | | | DESIGN MUST PRINT AND SIGN THEIR NAME TO | | | SAME PER 106.3.4.2. FBC AS AMENDED. THIS | | | ARTICLE ALSO IS AN EXTRACTION FROM THE | | | EXEMPTION IN CHAPTER 471 OF THE FLORIDA | | | STATUTES , 471.003, ALLOWING YOU TO DRAW | | | YOUR OWN PLANS . | | | | | | IF USING 220.35 FOR CALCULATION THERE IS | | | NO 80%. PLEASE USE CODE ARTICLES WHEN | | | CALCULATING LOADS. 220 PART II, | | | 220.31(B)- AHU AT 100%. ONLY THE | | | CIRCUITS IN THE GENERATOR PANEL NEED BE | | | CALCULATED. | | | | | | PLEASE LOCATE ALL SERVICE EQUIPMENT ON | | | THE PLAN, METER ENCLOSURE, | | | DISCONNECTS,ATS, GENERATOR AND PANELS, | | | SO THAT COMPLIANCE WITH ARTICLES 225 AND | | | 230 CAN BE REVIEWED. ASITE PLAN WILL | | | SUFFICE. | | | | | | SUBMIT MANUFACTURERS SPEC'S FOR THE ATS, | | | MUST BE SERVICE RATED OR HAVE A | | | DISCONNECTING MEANS FROM THE GENERATOR. | | | ARTICLE 225.31-225.38. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2006-06-05 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-06-05 |
Time |
16:23 |
Rev Time |
0.15 |
| Received By |
mperson |
Date |
2006-06-05 |
Time |
16:23 |
Sent To |
M |
|
| Notes |
| 2006-06-05 00:00:00 | NOTE: GAS PERMIT REQUIRED. GAS CONTRAC- | | | TOR TO SUBMIT PLANS WITH PERMIT APPLICA- | | | TION. ALL GAS INSPECTIONS TO BE COMPLETE | | | BEFORE FINAL GEN/RES INSPECTION. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-08-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-18 |
Time |
16:44 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-18 |
Time |
16:44 |
Sent To |
E |
|
| Notes |
| 2006-08-18 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-07-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-07-21 |
Time |
08:36 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-07-21 |
Time |
08:36 |
Sent To |
E |
|
| Notes |
| 2006-07-21 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-05-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-22 |
Time |
16:06 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-22 |
Time |
16:06 |
Sent To |
E |
|
| Notes |
| 2006-05-22 00:00:00 | TO "GEN-RES" "E" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-06-12 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-06-12 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-05-06 |
Time |
13:57 |
Sent To |
|
|
| Notes |
| 2006-05-06 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2006-06-05 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-06-05 |
Time |
16:23 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2006-06-05 |
Time |
16:23 |
Sent To |
G |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2006-05-22 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-05-22 |
Time |
11:14 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-05-22 |
Time |
11:14 |
Sent To |
I |
|
| Notes |
| 2006-05-22 00:00:00 | GENERATOR SITS BEYOND THE 25FT FRONT | | | SETBACK. |
|
|