Plan Review Details - Permit 06050166
Plan Review Stops For Permit 06050166
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2008-04-29 Cont ID  
Sent By lmartine Date 2008-04-29 Time 10:01 Rev Time 0.00
Received By lmartine Date 2008-04-29 Time 10:01 Sent To  
Notes
2008-04-29 10:02:34REVISION FOR LINEN CLOSETS AND PRODUCT APPROVALS

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2007-08-03 Cont ID  
Sent By lmartine Date 2007-08-03 Time 17:15 Rev Time 0.00
Received By lmartine Date 2007-08-03 Time 17:15 Sent To  
Notes
2007-08-03 17:21:51ROOF REVISION CHANGE FROM ASPH. SHINGLES TO CONCRETE
 TILES

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2006-10-12 Cont ID  
Sent By alange Date 2006-10-12 Time 14:12 Rev Time 0.00
Received By alange Date 2006-10-12 Time 14:12 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-06-12 Cont ID  
Sent By alange Date 2006-06-12 Time 09:29 Rev Time 2.25
Received By alange Date 2006-06-12 Time 09:24 Sent To  
Notes
2006-06-12 00:00:00DENIED
  
  
 1. 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE
 RE-RECORDED IF THE DESCRIBED IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 3.BASED ON ICC BUILDING VALUATION DATA
 THE PERMIT VALUE HAS BEEN REVISED TO
 $105,045.00.ADDITIONAL PERMIT FEES ARE
 DUE.
  
 4. ALL PLANS SUBMITTED AFTER OCTOBER, 1,
 2005 SHALL BE DESIGNED TO THE 2004
 FLORIDA BUILDING CODE.
  
 5.ENERGY CALCS "R" VALUES DO NOT MATCH
 THOSE ON PLANS.
  
 6.SUBMIT TWO SETS OF TRUSS DRAWINGS
 FOR REVIEW PER 2004 FBC R-802.10.1
  
 7.A DESIGN PROFESSIONAL OR AN OWNER
 MUST ELECT ONE OR A COMBINATION OF
 LEVELS OF ALTERATION PURSUANT TO
 SECTIONS 303, 304 AND 305 OF THIS CODE.
 SHOW HOW PLANS WILL COMPLY WITH THE
 SECTION(S) SELECTED.2004 FBC EXISTING
 BUILDING 301.5
  
 8.NOTE:FOOTINGS BEING USED ARE AT
 THE MINIMUM RECOMMENDATIONS FROM THE
 SOILS REPORT.JUST A NOTE, NO CHANGE IS
 REQUIRED.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. SUBMIT ONE COPY OF
 OLD PAGES FOR REFERENCE. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET
 OR SPECIFICATION PAGE WHERE THE CHANGES
 CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 ART LANGE
 CONSTRUCTION SERVICES DEPARTMENT
 BUILDING PLANS EXAMINER
 561-805-6672
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-09-26 Cont ID  
Sent By btrobaug Date 2006-09-26 Time 07:25 Rev Time 0.50
Received By btrobaug Date 2006-09-26 Time 06:22 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-05-30 Cont ID  
Sent By btrobaug Date 2006-05-30 Time 16:42 Rev Time 0.50
Received By btrobaug Date 2006-05-30 Time 15:41 Sent To P
Notes
2006-05-30 00:00:00 
 NONCOMPLIANT
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} SMOKE DETECTORS MUST BE INSTALLED TO
 COMPLY WITH R313.1 RESIDENTIAL FLORIDA
 BUILDING CODE.
  
 2} INDICATE COMPLIANCE WITH ARTICLE
 250.50 FOR THE GROUNDING ELECTRODE
 SYSTEM. ALL AVAILABLE MUST BE USED ON
 THE RISER. SEE 250.52(A)(3) FOR FOOTER
 STEEL.
  
 3} THE 7000 WATT HEAT STRIPS ARE
 CALCULATED AT 5700 WATTS. PLEASE CORRECT
 THE CALCULATION.
  
 4} THE GARAGE RECEPTACLES MUST BE GFI
 PROTECTED PER 210.52(G).
  
 5} TWO SETS OF PLANS ARE REQUIRED FOR
 REVIEW PER 106.1 FBC. ONLY ONE SHEET 4.5
 WAS SUBMITTED.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2008-04-01 Cont ID  
Sent By adarroug Date 2008-04-01 Time 09:29 Rev Time 0.00
Received By adarroug Date 2008-04-01 Time 09:29 Sent To B
Notes
2008-04-01 09:30:14TO "LMARTINEZ" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2007-12-04 Cont ID  
Sent By adarroug Date 2007-12-04 Time 15:34 Rev Time 0.00
Received By adarroug Date 2007-12-04 Time 15:34 Sent To M
Notes
2007-12-04 15:36:48TO "M" BOX/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2007-10-31 Cont ID  
Sent By adarroug Date 2007-10-31 Time 14:52 Rev Time 0.00
Received By adarroug Date 2007-10-31 Time 14:52 Sent To M
Notes
2007-10-31 14:53:12TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2007-06-25 Cont ID  
Sent By adarroug Date 2007-06-25 Time 14:24 Rev Time 0.00
Received By adarroug Date 2007-06-25 Time 14:24 Sent To B
Notes
2007-06-25 14:25:20TO "LMARTINEZ" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-09-20 Cont ID  
Sent By adarroug Date 2006-09-20 Time 15:48 Rev Time 0.00
Received By adarroug Date 2006-09-20 Time 15:48 Sent To E
Notes
2006-09-20 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-05-22 Cont ID  
Sent By adarroug Date 2006-05-22 Time 12:51 Rev Time 0.00
Received By adarroug Date 2006-05-22 Time 12:51 Sent To E
Notes
2006-05-22 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-06-12 Cont ID  
Sent By alange Date 2006-06-12 Time 09:24 Rev Time 0.00
Received By alange Date 2006-05-05 Time 09:35 Sent To  
Notes
2006-05-05 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2007-12-05 Cont ID  
Sent By tgordon Date 2007-12-05 Time 09:05 Rev Time 0.25
Received By tgordon Date 2007-12-05 Time 09:05 Sent To  
Notes
2007-12-05 09:06:10REVISION TO MECH. PLANS.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2007-11-05 Cont ID  
Sent By tgordon Date 2007-11-05 Time 14:54 Rev Time 0.25
Received By tgordon Date 2007-11-05 Time 14:53 Sent To  
Notes
2007-11-05 15:00:04PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 05, 06 REVISIONS, CITY OF WEST
 PALM BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 MECHANICAL REVISION
 *** DENIED ***
 1) NEED TO SUBMIT THE ENTIRE MECHANICAL PLAN NOT JUST A
 SMALL PART OF THE PAGE, SEE 2004 WPB AMEND 106.1.3.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2006-06-02 Cont ID  
Sent By jleech Date 2006-06-07 Time 13:50 Rev Time 0.30
Received By tgordon Date 2006-06-02 Time 16:24 Sent To P
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2006-10-12 Cont ID  
Sent By jleech Date 2006-10-12 Time 13:11 Rev Time 0.00
Received By jleech Date 2006-10-12 Time 13:10 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2006-06-07 Cont ID  
Sent By jleech Date 2006-06-02 Time 14:49 Rev Time 0.00
Received By jleech Date 2006-06-02 Time 14:49 Sent To B
Notes
2006-06-07 00:00:00DENIED;
 MISSING PAGE 3 IN ONE SET OF PLANS.

Review Stop Z ZONING
Rev No 1 Status P Date 2006-05-19 Cont ID  
Sent By mmclean Date 2006-05-19 Time 14:08 Rev Time 0.00
Received By mmclean Date 2006-05-19 Time 14:08 Sent To I
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved