Plan Review Details - Permit 06050090
Plan Review Stops For Permit 06050090
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-05-26 Cont ID  
Sent By amorse Date 2006-05-26 Time 07:05 Rev Time 0.50
Received By amorse Date 2006-05-26 Time 07:05 Sent To PC
Notes
2006-05-26 00:00:00 
  
 DENIED
  
 1) PROVIDE A PLAN VIEW DRAWING OF HOUSE
 SHOWING ALL WINDOW AND DOOR OPENINGS
 WITH GLAZING. PROVIDE ALL OPENING
 DIMENSIONS AND SHOW WHICH WINDOWS WILL
 BE REPLACED.PLEASE KNOW THAT IF WINDOW
 OPENING SIZES ARE CHANGED AND THOSE
 OPENINGS ARE IN BEDROOMS THEY SHALL MEET
 THE EMERGENCY EGRESS REQUIREMENTS OF THE
 2004 FBC R310.1
  
 2) THE WINDOWS THAT ARE TO BE INSTALLED
 ARE NON-IMPACT, IF THE AGREGATE AREA OF
 THE GLAZING BEING INSTALLED IS MORE THAN
 25% OF THE TOTAL GLAZED AREA OF THE
 DWELLING THEN OPENING PROTECTIVES SHALL
 BE INSTALLED AND SHUTTER PRODUCT
 APPROVAL WILL BE REQUIRED. PER 507.3 FBC
 EXISTING BUILDING
  
 3) ON THE PLAN OF DWELLING STATE TYPE OF
 CONSTRUCTION, WOOD FRAME, MASONARY
 BLOCK.
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2006-05-26 Time   Rev Time 0.00
Received By adarroug Date 2006-05-03 Time 11:44 Sent To  
Notes
2006-05-03 00:00:00TO "MISC" BOX#1