Plan Review Stops For Permit 06050086
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2006-05-10 Cont ID  
Sent By rmcdouga Date 2006-05-10 Time 16:41 Rev Time 0.00
Received By rmcdouga Date 2006-05-10 Time 16:41 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-05-03 Cont ID  
Sent By rmcdouga Date 2006-05-03 Time 07:49 Rev Time 0.00
Received By rmcdouga Date 2006-05-03 Time 07:49 Sent To  
Notes
2006-05-03 00:00:00DENIED
  
 1) THE MIAMI-DADE NOA FOR THE GAF
 TIMBERLINE SHINGLES LIMITS THEIR
 INSTALLATION TO BUILDINGS WITH MEAN ROOF
 HEIGHTS OF 33 FEET OR LESS. THE PERMIT
 APPLICATION LISTS ROOF HEIGHT AS
 37'-10". SEE LIMITATIONS #4.2 ON PAGE 2
 OF THE NOA.
  
 FBC 1609.2 DEFINITIONS
 MEAN ROOF HEIGHT. THE AVERAGE OF THE
 ROOF EAVE HEIGHT AND THE HEIGHT TO THE
 HIGHEST POINT ON THE ROOF SURFACE,
 EXCEPT THAT EAVE HEIGHT SHALL BE USED
 FOR ROOF ANGLE OF LESS THAN OR EQUAL TO
 10 DEGREES (0.1745 RAD).
  
 2)A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714