Plan Review Details - Permit 06041252
Plan Review Stops For Permit 06041252
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2006-09-25 Cont ID  
Sent By lmartine Date 2006-09-25 Time 14:36 Rev Time 1.00
Received By alange Date 2006-09-25 Time 14:59 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-08-08 Cont ID  
Sent By alange Date 2006-08-08 Time 14:35 Rev Time 1.50
Received By alange Date 2006-08-08 Time 14:23 Sent To  
Notes
2006-08-08 00:00:00DENIED
  
  
 1.BASED ON ICC BUILDING VALUATION DATA
 THE PERMIT VALUE HAS BEEN REVISED TO
 $43,368.ADDITIONAL PERMIT FEES ARE
 DUE.
  
 2.SIGN OWNER/AGENT ON ENERGY CALCS
 PER 2004 FBC.
  
 9.SUBMIT TWO ORIGONAL SIGNED AND
 SEALED SURVEYS. FS 472.025
  
 NEW COMMENTS:
  
 A.713.13(2) F.S.THE NOTICE OF
 COMMENCEMENT MUST BE RE-RECORDED BECAUSE
 THE DESCRIBED IMPROVEMENT OR
 CONSTRUCTION DID NOT COMMENCE WITHIN 90
 DAYS OF RECORDING.
  
 B.SHOW BUILDING SEPERATIONS ALONG WITH
 OVERHANGS ON A SITE PLAN SO THAT
 COMPLIANCE WITH THE FOLLOWING SECTIONS
 CAN BE VERIFIED.
 R-302.2 PROJECTIONS EXTENDING INTO THE
 6-FOOT SEPARATION DISTANCE SHALL HAVE
 NOT LESS THAN 1-HOUR FIRE-RESISTIVE
 CONSTRUCTION ON THE UNDERSIDE. THE ABOVE
 PROVISIONS SHALL NOT APPLY TO WALLS
 WHICH ARE PERPENDICULAR TO A LINE
 EXTENDING FROM THE POINT FROM WHICH THE
 SEPARATION DISTANCE HAS BEEN MEASURED
 RUNNING AND PARALLEL TO THE PROPERTY
 LINE.
  
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. SUBMIT ONE COPY OF
 OLD PAGES FOR REFERENCE. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET
 OR SPECIFICATION PAGE WHERE THE CHANGES
 CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 ART LANGE
 CONSTRUCTION SERVICES DEPARTMENT
 BUILDING PLANS EXAMINER
 561-805-6672
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-05-26 Cont ID  
Sent By mperson Date 2006-05-24 Time 14:08 Rev Time 1.50
Received By alange Date 2006-05-26 Time 10:49 Sent To  
Notes
2006-05-26 00:00:00DENIED
  
  
 1.BASED ON ICC BUILDING VALUATION DATA
 THE PERMIT VALUE HAS BEEN REVISED TO
 $43,368.ADDITIONAL PERMIT FEES ARE
 DUE.
  
 2.SUBMIT TWO COPIES OF ENERGY CALCS
 PER 2004 FBC.
  
 3.PRODUCT APPROVALS REQUIRED FOR
 LINTELS.
  
 4.ALL PRODUCT APPROVALS SUBMITTED WITH
 QUALITY ASSURANCE SHALL HAVE THE
 FOLLOWING STATE APPROVAL ATTACHED.
  
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A STATE PRODUCT APPROVAL
 SHEETS THAT LISTS THE PRODUCT IDENTITY
 NUMBER FROM THE STATE. IF THE PRODUCT
 DOES NOT HAVE STATEWIDE APPROVAL, SUBMIT
 AN APPLICATION FOR LOCAL PRODUCT
 APPROVAL OR SITE SPECIFIC FORM PER RULE
 9B-72. SEE ATTACHMENT.
 WWW.FLORIDABUILDING.ORG
  
 5.THOSE PRODUCT APPROVALS WHICH ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.WPB
 AMENDMENT TO FBC 106.3.3.
  
 6.SUBMIT TWO SETS OF TRUSS DRAWINGS
 FOR REVIEW PER 2004 FBC R-802.10.1
  
 7.WRONG EXPOSURE AREA LISTED.SEE
 1609.4 FBC 2004
  
 8.ENGINEERS SEAL SHOULD READ
 "LICENSED" NOT CERTIFICATE 61G1-16.001
  
 9.SUBMIT TWO ORIGONA' SIGNED AND
 SEALED SURVEYS. FS 472.025
  
 10.SHOW SIZE AND LOCATION OF ATTIC
 ACCESS PER FBC 2004 R-807.1
  
 11.PLANS SHALL NOT BE DRAWN IN PENCIL.
 106.1.3 WPB AMMENDMENTS TO THE FBC
  
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. SUBMIT ONE COPY OF
 OLD PAGES FOR REFERENCE. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET
 OR SPECIFICATION PAGE WHERE THE CHANGES
 CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 ART LANGE
 CONSTRUCTION SERVICES DEPARTMENT
 BUILDING PLANS EXAMINER
 561-805-6672
  
2006-05-24 00:00:00 
  

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2007-05-23 Cont ID  
Sent By btrobaug Date 2007-05-23 Time 10:18 Rev Time 0.50
Received By btrobaug Date 2007-05-23 Time 09:49 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-09-13 Cont ID  
Sent By btrobaug Date 2006-09-13 Time 17:30 Rev Time 1.00
Received By btrobaug Date 2006-09-11 Time 16:42 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2006-08-07 Cont ID  
Sent By btrobaug Date 2006-08-07 Time 15:24 Rev Time 0.50
Received By btrobaug Date 2006-08-07 Time 14:50 Sent To P
Notes
2006-08-07 00:00:00 
  
  
 NONCOMPLIANT
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} A GROUNDING ELECTRODE CONDUCTOR IS
 REQUIRED AT THE SEPARATE STRUCTURE PER
 250.32, SIZED PER 250.66.
  
 2} BATH CIRCUIT REQUIRED TO HAVE A 20
 AMP RECEPTACLE PER 210.11(C)(3), LOCATED
 PER 210.52(D), AND BE GFI PROTECTED PER
 210.8(A)(1).INDICATE COMPLIANCE ON THE
 PLAN AND IN THE PANEL SCXHEDULE.
  
 3} THE "MINI SPLIT A/C UNIT" ON THE PLAN
 IS NOT IN THE PANEL SCHEDULE. ALSO
 VERIFY THE SPECIFICATIONS IN THE
 CALCULATION. (10K)?
  
 4} THE ENGINEER OF RECORD MUST SIGN,
 SEAL AND DATE THE DOCUMENTS PER 471.025
 FLORIDA STATUTES.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2006-05-23 Cont ID  
Sent By btrobaug Date 2006-05-23 Time 12:36 Rev Time 0.50
Received By btrobaug Date 2006-05-23 Time 12:10 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2007-05-11 Cont ID  
Sent By adarroug Date 2007-05-11 Time 09:26 Rev Time 0.00
Received By adarroug Date 2007-05-11 Time 09:26 Sent To E
Notes
2007-05-11 09:27:05TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-08-24 Cont ID  
Sent By adarroug Date 2006-08-24 Time 13:36 Rev Time 0.00
Received By adarroug Date 2006-08-24 Time 13:36 Sent To E
Notes
2006-08-24 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-08-03 Cont ID  
Sent By adarroug Date 2006-08-03 Time 09:46 Rev Time 0.00
Received By adarroug Date 2006-08-03 Time 09:46 Sent To E
Notes
2006-08-03 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-07-26 Cont ID  
Sent By adarroug Date 2006-07-26 Time 14:11 Rev Time 0.00
Received By adarroug Date 2006-07-26 Time 13:57 Sent To Z
Notes
2006-07-26 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-05-22 Cont ID  
Sent By adarroug Date 2006-05-22 Time 11:27 Rev Time 0.00
Received By adarroug Date 2006-05-22 Time 11:27 Sent To E
Notes
2006-05-22 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-05-26 Cont ID  
Sent By alange Date 2006-05-26 Time 11:06 Rev Time 0.00
Received By alange Date 2006-05-01 Time 08:58 Sent To  
Notes
2006-05-01 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2006-12-11 Cont ID  
Sent By tgordon Date 2006-12-11 Time 08:15 Rev Time 0.20
Received By tgordon Date 2006-12-11 Time 08:15 Sent To  
Notes
2006-12-11 08:16:15REVISION MECH. PLANS.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2006-05-25 Cont ID  
Sent By lmartine Date 2006-09-21 Time 14:36 Rev Time 0.25
Received By tgordon Date 2006-05-25 Time 08:07 Sent To B
Notes
2006-05-25 00:00:00NO MECHANICAL PERMIT APPLIED FOR AT THIS
 TIME.
  
 1) PLEASE NOTE WHEN APPLING FOR THE
 MECHANICAL PERMIT SHOW A/C EQUIPMENT
 LISTING ON PLANS.
  
 2) PLEASE SUBMIT ENERGY CALCULATIONS FOR
 THE BUILDING PERMIT, PER 2004 FBC
 13-600.3.A .
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2006-09-14 Cont ID  
Sent By mperson Date 2006-09-14 Time 09:12 Rev Time 0.33
Received By mperson Date 2006-09-14 Time 09:12 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2006-08-07 Cont ID  
Sent By mperson Date 2006-08-07 Time 16:27 Rev Time 0.45
Received By mperson Date 2006-08-07 Time 16:27 Sent To B
Notes
2006-08-07 00:00:00******DENIED 2ND TIME******
 REFERENCE: FBC-2004 PLUMBING
 FBC-2004 CHAPTER 1
 FLORIDA STATUTES
  
 THE FOLLOWING INFORMATION IS STILL
 REQUIRED FOR PLUMBING PLAN REVIEW:
  
 1. THE ISOMETRIC SANITARY PLUMBING RISER
 DIAGRAM ON SHEET 6 OF 6 STILL DOES NOT
 REFLECT THE FLOOR PLAN. THE TUB AND
 DOUBLE BOWL SINK ARE INDICATED WRONG PER
 THE FLOOR PLAN LAYOUT. PLEASE SEE
 CORRECTED SANITARY ISOMETRIC PLUMBING
 RISER DIAGRAM IN RED INK FOR REFERENCE
 FOR RESUBMITTAL.
 2. ALL PIPES AND TRAPS MUST BE SIZED PER
 FBC-2004, CHAPTER 1, SECTION 106.3.5.4.
 PLEASE REFERENCE CORRECTED PLMG. RISER
 ON SHEET 6 OF 6 FOR REFERENCE FOR
 RESUBMITTAL.
 3. PLEASE SEE ELECTRICAL COMMENT #4
 STATE STATUTE 471.025 ENGINEER OF RECORD
 MUST SIGN, SEAL AND DATE DOCUMENTS.
  
 **IN ORDER TO EXPIDITE PLAN REVIEW: WHEN
 RESUBMITTING, PLEASE REPLACE ONLY SHEETS
 WHICH HAVE CHANGED AND PROVIDE ONE COPY
 OF ALL OLD/VOIDED SHEETS FOR REFERENCE
 ONLY. NOTE: ONLY ONE CORRECTED DRAWING
 IN RED INK FOR REFERENCE FOR
 RESUBMITTAL.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2006-09-21 Cont ID  
Sent By mperson Date 2006-05-24 Time 15:30 Rev Time 0.00
Received By lmartine Date 2006-09-21 Time 14:35 Sent To M
Notes
2006-05-24 00:00:00******DENIED******
 REFERENCE:FBC-2004 PLUMBING
 FBC-2004 CHAPTER 1
  
 THE FOLLOWING INFORMATION IS REQUIRED
 FOR PLUMBING PLAN REVIEW FOR A PERMIT:
  
 1. THE SANITARY PLUMBING ISOMETRIC RISER
 DIAGRAM ON SHEET D3 DOES NOT REFLECT THE
 FLOOR PLAN ON SHEET F1. THE FOLLOWING
 ARE MINIMUM REQUIREMENTS FOR THE
 SANITARY PLUMBING ISOMETRIC RISER
 DIAGRAM.
 (A) 106.3.5.4 RESIDENTIAL (ONE AND TWO
 FAMILY) SUBMIT A PLUMBING SANITARY
 ISOMETRIC RISER DIAGRAM INDICATING ALL
 WASTE, VENTS, TRAPS WITH SIZES, AND
 CLEANOUT LOCATIONS.(NOTE: PIPE SIZES NOT
 INDICATED FOR THE TUB, LAV, W/C, AND
 SINK IN WET BAR IS MIS LABELED LAV AND
 BOTH BOWLS OF SINK NEED TO BE INDICATED
 AND SIZED. PLEASE REFERENCE CORRECTED
 DRAWING ON SHEET D3 FOR RESUBMITTAL.)
 2. THE FOLLOWING ARE REQUIREMENTS FOR
 CLEANOUT LOCATIONS ON THE PLBG. SANITARY
 ISO. RISER DIAGRAM. PLEASE REFERENCE
 CORRECTED DRAWING ON SHEET D3 FOR
 RESUBMITTAL.
 (A) 708.3.4 BASE OF STACK. A CLEANOUT
 SHALL BE PROVIDED AT THE BASE OF EACH
 WASTE OR SOIL STACK
 (B) 708.3.5 BUILDING DRAIN AND BUILDING
 SEWER JUNCTION. THERE SHALL BE A
 CLEANOUT NEAR THE JUNCTION OF THE
 BUILDING DRAIN AND THE BUILDING SEWER.
 3. THE TUB INDICATED ON SHEET D3
 SANITARY PLBG. ISO. RISER DIAGRAM IS NOT
 VENTED PER SECTION 901.2.1.
 4. SEE EXAMPLE OF PLBG. ISO. RISER
 DIAGRAM THAT MEETS CODE ATTACHED TO PLBG
 COMMENTS FOR RESUBMITTAL REFERENCE.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721
  

Review Stop Z ZONING
Rev No 2 Status P Date 2006-08-02 Cont ID  
Sent By mmclean Date 2006-08-02 Time 07:30 Rev Time 0.00
Received By mmclean Date 2006-08-02 Time 07:30 Sent To I
Notes
2006-08-02 00:00:00POOL CABANA.

Review Stop Z ZONING
Rev No 1 Status F Date 2006-05-17 Cont ID  
Sent By mmclean Date 2006-05-17 Time 16:54 Rev Time 0.00
Received By mmclean Date 2006-05-17 Time 16:53 Sent To I
Notes
2006-05-17 00:00:00DENIED,
 1. MUST PROVIDE SITEPLAN THAT SHOWS THE
 ADDRESS OF PROPERTY.
 2. MUST SHOW ON THE SITEPLAN OR SURVEY
 THE DISTANCE OF THE PROPOSED CABANA FROM
 MAIN STRUCTURE.
  
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720