| Plan Review Stops For Permit 06041252 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2006-09-25 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2006-09-25 |
Time |
14:36 |
Rev Time |
1.00 |
| Received By |
alange |
Date |
2006-09-25 |
Time |
14:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-08-08 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-08-08 |
Time |
14:35 |
Rev Time |
1.50 |
| Received By |
alange |
Date |
2006-08-08 |
Time |
14:23 |
Sent To |
|
|
| Notes |
| 2006-08-08 00:00:00 | DENIED | | | | | | | | | 1.BASED ON ICC BUILDING VALUATION DATA | | | THE PERMIT VALUE HAS BEEN REVISED TO | | | $43,368.ADDITIONAL PERMIT FEES ARE | | | DUE. | | | | | | 2.SIGN OWNER/AGENT ON ENERGY CALCS | | | PER 2004 FBC. | | | | | | 9.SUBMIT TWO ORIGONAL SIGNED AND | | | SEALED SURVEYS. FS 472.025 | | | | | | NEW COMMENTS: | | | | | | A.713.13(2) F.S.THE NOTICE OF | | | COMMENCEMENT MUST BE RE-RECORDED BECAUSE | | | THE DESCRIBED IMPROVEMENT OR | | | CONSTRUCTION DID NOT COMMENCE WITHIN 90 | | | DAYS OF RECORDING. | | | | | | B.SHOW BUILDING SEPERATIONS ALONG WITH | | | OVERHANGS ON A SITE PLAN SO THAT | | | COMPLIANCE WITH THE FOLLOWING SECTIONS | | | CAN BE VERIFIED. | | | R-302.2 PROJECTIONS EXTENDING INTO THE | | | 6-FOOT SEPARATION DISTANCE SHALL HAVE | | | NOT LESS THAN 1-HOUR FIRE-RESISTIVE | | | CONSTRUCTION ON THE UNDERSIDE. THE ABOVE | | | PROVISIONS SHALL NOT APPLY TO WALLS | | | WHICH ARE PERPENDICULAR TO A LINE | | | EXTENDING FROM THE POINT FROM WHICH THE | | | SEPARATION DISTANCE HAS BEEN MEASURED | | | RUNNING AND PARALLEL TO THE PROPERTY | | | LINE. | | | | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. SUBMIT ONE COPY OF | | | OLD PAGES FOR REFERENCE. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET | | | OR SPECIFICATION PAGE WHERE THE CHANGES | | | CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | ART LANGE | | | CONSTRUCTION SERVICES DEPARTMENT | | | BUILDING PLANS EXAMINER | | | 561-805-6672 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-05-26 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-05-24 |
Time |
14:08 |
Rev Time |
1.50 |
| Received By |
alange |
Date |
2006-05-26 |
Time |
10:49 |
Sent To |
|
|
| Notes |
| 2006-05-26 00:00:00 | DENIED | | | | | | | | | 1.BASED ON ICC BUILDING VALUATION DATA | | | THE PERMIT VALUE HAS BEEN REVISED TO | | | $43,368.ADDITIONAL PERMIT FEES ARE | | | DUE. | | | | | | 2.SUBMIT TWO COPIES OF ENERGY CALCS | | | PER 2004 FBC. | | | | | | 3.PRODUCT APPROVALS REQUIRED FOR | | | LINTELS. | | | | | | 4.ALL PRODUCT APPROVALS SUBMITTED WITH | | | QUALITY ASSURANCE SHALL HAVE THE | | | FOLLOWING STATE APPROVAL ATTACHED. | | | | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A STATE PRODUCT APPROVAL | | | SHEETS THAT LISTS THE PRODUCT IDENTITY | | | NUMBER FROM THE STATE. IF THE PRODUCT | | | DOES NOT HAVE STATEWIDE APPROVAL, SUBMIT | | | AN APPLICATION FOR LOCAL PRODUCT | | | APPROVAL OR SITE SPECIFIC FORM PER RULE | | | 9B-72. SEE ATTACHMENT. | | | WWW.FLORIDABUILDING.ORG | | | | | | 5.THOSE PRODUCT APPROVALS WHICH ARE | | | REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL | | | FOR JURISDICTIONAL APPROVAL.WPB | | | AMENDMENT TO FBC 106.3.3. | | | | | | 6.SUBMIT TWO SETS OF TRUSS DRAWINGS | | | FOR REVIEW PER 2004 FBC R-802.10.1 | | | | | | 7.WRONG EXPOSURE AREA LISTED.SEE | | | 1609.4 FBC 2004 | | | | | | 8.ENGINEERS SEAL SHOULD READ | | | "LICENSED" NOT CERTIFICATE 61G1-16.001 | | | | | | 9.SUBMIT TWO ORIGONA' SIGNED AND | | | SEALED SURVEYS. FS 472.025 | | | | | | 10.SHOW SIZE AND LOCATION OF ATTIC | | | ACCESS PER FBC 2004 R-807.1 | | | | | | 11.PLANS SHALL NOT BE DRAWN IN PENCIL. | | | 106.1.3 WPB AMMENDMENTS TO THE FBC | | | | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. SUBMIT ONE COPY OF | | | OLD PAGES FOR REFERENCE. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET | | | OR SPECIFICATION PAGE WHERE THE CHANGES | | | CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | ART LANGE | | | CONSTRUCTION SERVICES DEPARTMENT | | | BUILDING PLANS EXAMINER | | | 561-805-6672 | | | | | 2006-05-24 00:00:00 | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2007-05-23 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-05-23 |
Time |
10:18 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2007-05-23 |
Time |
09:49 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-09-13 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-09-13 |
Time |
17:30 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2006-09-11 |
Time |
16:42 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-08-07 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-08-07 |
Time |
15:24 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-08-07 |
Time |
14:50 |
Sent To |
P |
|
| Notes |
| 2006-08-07 00:00:00 | | | | | | | | | | NONCOMPLIANT | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} A GROUNDING ELECTRODE CONDUCTOR IS | | | REQUIRED AT THE SEPARATE STRUCTURE PER | | | 250.32, SIZED PER 250.66. | | | | | | 2} BATH CIRCUIT REQUIRED TO HAVE A 20 | | | AMP RECEPTACLE PER 210.11(C)(3), LOCATED | | | PER 210.52(D), AND BE GFI PROTECTED PER | | | 210.8(A)(1).INDICATE COMPLIANCE ON THE | | | PLAN AND IN THE PANEL SCXHEDULE. | | | | | | 3} THE "MINI SPLIT A/C UNIT" ON THE PLAN | | | IS NOT IN THE PANEL SCHEDULE. ALSO | | | VERIFY THE SPECIFICATIONS IN THE | | | CALCULATION. (10K)? | | | | | | 4} THE ENGINEER OF RECORD MUST SIGN, | | | SEAL AND DATE THE DOCUMENTS PER 471.025 | | | FLORIDA STATUTES. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2006-05-23 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-05-23 |
Time |
12:36 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-05-23 |
Time |
12:10 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2007-05-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-05-11 |
Time |
09:26 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-11 |
Time |
09:26 |
Sent To |
E |
|
| Notes |
| 2007-05-11 09:27:05 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-08-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-24 |
Time |
13:36 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-24 |
Time |
13:36 |
Sent To |
E |
|
| Notes |
| 2006-08-24 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-08-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-03 |
Time |
09:46 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-03 |
Time |
09:46 |
Sent To |
E |
|
| Notes |
| 2006-08-03 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-07-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-07-26 |
Time |
14:11 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-07-26 |
Time |
13:57 |
Sent To |
Z |
|
| Notes |
| 2006-07-26 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-05-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-22 |
Time |
11:27 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-22 |
Time |
11:27 |
Sent To |
E |
|
| Notes |
| 2006-05-22 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-05-26 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-05-26 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-05-01 |
Time |
08:58 |
Sent To |
|
|
| Notes |
| 2006-05-01 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2006-12-11 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-12-11 |
Time |
08:15 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2006-12-11 |
Time |
08:15 |
Sent To |
|
|
| Notes |
| 2006-12-11 08:16:15 | REVISION MECH. PLANS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2006-05-25 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2006-09-21 |
Time |
14:36 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2006-05-25 |
Time |
08:07 |
Sent To |
B |
|
| Notes |
| 2006-05-25 00:00:00 | NO MECHANICAL PERMIT APPLIED FOR AT THIS | | | TIME. | | | | | | 1) PLEASE NOTE WHEN APPLING FOR THE | | | MECHANICAL PERMIT SHOW A/C EQUIPMENT | | | LISTING ON PLANS. | | | | | | 2) PLEASE SUBMIT ENERGY CALCULATIONS FOR | | | THE BUILDING PERMIT, PER 2004 FBC | | | 13-600.3.A . | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2006-09-14 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-09-14 |
Time |
09:12 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2006-09-14 |
Time |
09:12 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2006-08-07 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-08-07 |
Time |
16:27 |
Rev Time |
0.45 |
| Received By |
mperson |
Date |
2006-08-07 |
Time |
16:27 |
Sent To |
B |
|
| Notes |
| 2006-08-07 00:00:00 | ******DENIED 2ND TIME****** | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | FLORIDA STATUTES | | | | | | THE FOLLOWING INFORMATION IS STILL | | | REQUIRED FOR PLUMBING PLAN REVIEW: | | | | | | 1. THE ISOMETRIC SANITARY PLUMBING RISER | | | DIAGRAM ON SHEET 6 OF 6 STILL DOES NOT | | | REFLECT THE FLOOR PLAN. THE TUB AND | | | DOUBLE BOWL SINK ARE INDICATED WRONG PER | | | THE FLOOR PLAN LAYOUT. PLEASE SEE | | | CORRECTED SANITARY ISOMETRIC PLUMBING | | | RISER DIAGRAM IN RED INK FOR REFERENCE | | | FOR RESUBMITTAL. | | | 2. ALL PIPES AND TRAPS MUST BE SIZED PER | | | FBC-2004, CHAPTER 1, SECTION 106.3.5.4. | | | PLEASE REFERENCE CORRECTED PLMG. RISER | | | ON SHEET 6 OF 6 FOR REFERENCE FOR | | | RESUBMITTAL. | | | 3. PLEASE SEE ELECTRICAL COMMENT #4 | | | STATE STATUTE 471.025 ENGINEER OF RECORD | | | MUST SIGN, SEAL AND DATE DOCUMENTS. | | | | | | **IN ORDER TO EXPIDITE PLAN REVIEW: WHEN | | | RESUBMITTING, PLEASE REPLACE ONLY SHEETS | | | WHICH HAVE CHANGED AND PROVIDE ONE COPY | | | OF ALL OLD/VOIDED SHEETS FOR REFERENCE | | | ONLY. NOTE: ONLY ONE CORRECTED DRAWING | | | IN RED INK FOR REFERENCE FOR | | | RESUBMITTAL. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2006-09-21 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-05-24 |
Time |
15:30 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2006-09-21 |
Time |
14:35 |
Sent To |
M |
|
| Notes |
| 2006-05-24 00:00:00 | ******DENIED****** | | | REFERENCE:FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | | | | THE FOLLOWING INFORMATION IS REQUIRED | | | FOR PLUMBING PLAN REVIEW FOR A PERMIT: | | | | | | 1. THE SANITARY PLUMBING ISOMETRIC RISER | | | DIAGRAM ON SHEET D3 DOES NOT REFLECT THE | | | FLOOR PLAN ON SHEET F1. THE FOLLOWING | | | ARE MINIMUM REQUIREMENTS FOR THE | | | SANITARY PLUMBING ISOMETRIC RISER | | | DIAGRAM. | | | (A) 106.3.5.4 RESIDENTIAL (ONE AND TWO | | | FAMILY) SUBMIT A PLUMBING SANITARY | | | ISOMETRIC RISER DIAGRAM INDICATING ALL | | | WASTE, VENTS, TRAPS WITH SIZES, AND | | | CLEANOUT LOCATIONS.(NOTE: PIPE SIZES NOT | | | INDICATED FOR THE TUB, LAV, W/C, AND | | | SINK IN WET BAR IS MIS LABELED LAV AND | | | BOTH BOWLS OF SINK NEED TO BE INDICATED | | | AND SIZED. PLEASE REFERENCE CORRECTED | | | DRAWING ON SHEET D3 FOR RESUBMITTAL.) | | | 2. THE FOLLOWING ARE REQUIREMENTS FOR | | | CLEANOUT LOCATIONS ON THE PLBG. SANITARY | | | ISO. RISER DIAGRAM. PLEASE REFERENCE | | | CORRECTED DRAWING ON SHEET D3 FOR | | | RESUBMITTAL. | | | (A) 708.3.4 BASE OF STACK. A CLEANOUT | | | SHALL BE PROVIDED AT THE BASE OF EACH | | | WASTE OR SOIL STACK | | | (B) 708.3.5 BUILDING DRAIN AND BUILDING | | | SEWER JUNCTION. THERE SHALL BE A | | | CLEANOUT NEAR THE JUNCTION OF THE | | | BUILDING DRAIN AND THE BUILDING SEWER. | | | 3. THE TUB INDICATED ON SHEET D3 | | | SANITARY PLBG. ISO. RISER DIAGRAM IS NOT | | | VENTED PER SECTION 901.2.1. | | | 4. SEE EXAMPLE OF PLBG. ISO. RISER | | | DIAGRAM THAT MEETS CODE ATTACHED TO PLBG | | | COMMENTS FOR RESUBMITTAL REFERENCE. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2006-08-02 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-08-02 |
Time |
07:30 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-08-02 |
Time |
07:30 |
Sent To |
I |
|
| Notes |
| 2006-08-02 00:00:00 | POOL CABANA. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2006-05-17 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-05-17 |
Time |
16:54 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-05-17 |
Time |
16:53 |
Sent To |
I |
|
| Notes |
| 2006-05-17 00:00:00 | DENIED, | | | 1. MUST PROVIDE SITEPLAN THAT SHOWS THE | | | ADDRESS OF PROPERTY. | | | 2. MUST SHOW ON THE SITEPLAN OR SURVEY | | | THE DISTANCE OF THE PROPOSED CABANA FROM | | | MAIN STRUCTURE. | | | | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|