Plan Review Details - Permit 06041187
Plan Review Stops For Permit 06041187
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2007-06-13 Cont ID  
Sent By amorse Date 2007-06-13 Time 15:49 Rev Time 0.00
Received By amorse Date 2007-06-13 Time 15:49 Sent To PC
Notes
2007-06-13 15:50:08 
  
 ******REVISION DENIED******
  
 1)UNDER ENGINEERS FINDINGS (NOTE C) THE STEEL STUD
 HAS A 33 KSI STEEL YIELD STRENGTH BUT THE STRUCTURAL
 DRAWING S/1 AND THE FLORIDA STATEWIDE PRODUCT APPROVAL
 BOTH STATE A MINIMUM OF 36 KSI IS REQUIRED.
  
 2)ENGINEER SHEET S/1 IS FOR A CHANGE IN FASTENER TYPE
 FROM THE PRODUCT APPROVAL FL# 5337 AND AS SUCH REQUIRES
 THE ENGINEER OF RECORDS STATEMENT THAT THE NEW FASTENER
 MEETS OR EXCEEDS THE ORIGINAL FASTENERS. CONCLUSIONS
 ONLY STATE THAT THE NUAIR SERIES 9000 WINDOWS WHEN
 ATTACHED TO THE EXISTING STRUCTURE IS SUBSTANTIALLY
 EQUIVALENT.
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2006-06-12 Cont ID  
Sent By amorse Date 2006-06-12 Time 16:03 Rev Time 0.50
Received By amorse Date 2006-06-12 Time 16:03 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-05-20 Cont ID  
Sent By amorse Date 2006-05-20 Time 14:43 Rev Time 0.33
Received By amorse Date 2006-05-20 Time 14:43 Sent To PC
Notes
2006-05-20 00:00:00 
  
  
 DENIED
  
 1) PROVIDE BUILDING PLAN LAYOUT (ONE
 FLOOR IF ALL ARE THE SAME) SHOW WINDOW
 LOCATIONS AND SIZES
  
 2) PROVIDE GLASS TYPE TO DETERMINE
 REQUIREDDESIGN PRESSURES ON WINDOWS
  
 3) PROVIDE BUILDING MEAN ROOF HEIGHT
 TO DETERMINE REQUIRED DESIGN PRESSURE ON
 WINDOWS
  
 4) PROVIDE 2 COPIES OF FLORIDA COVER
 SHEETS FOR SH WINDOWS MODEL 002-002 (FL#
 5254)
  
 5) PROVIDE COPIES OF NOC WITH EACH
 APPLICATION
  
 ADRIAN MORSE
 BLDG PLAN REVIEW
 561-805-6716

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-06-11 Cont ID  
Sent By adarroug Date 2007-06-11 Time 13:51 Rev Time 0.00
Received By adarroug Date 2007-06-11 Time 13:51 Sent To B
Notes
2007-06-11 13:52:13TO "AMORSE" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-06-08 Cont ID  
Sent By adarroug Date 2006-06-08 Time 15:18 Rev Time 0.00
Received By adarroug Date 2006-06-08 Time 15:18 Sent To B
Notes
2006-06-08 00:00:00TO "AMORSE" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2006-05-20 Time   Rev Time 0.00
Received By adarroug Date 2006-04-29 Time 15:28 Sent To  
Notes
2006-04-29 00:00:00TO "MISC' BOX#1


Account Summary | Usage Policy | Privacy Policy