| Plan Review Stops For Permit 06040989 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2006-09-07 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-09-07 |
Time |
10:23 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-09-07 |
Time |
10:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2006-08-25 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-08-25 |
Time |
09:01 |
Rev Time |
1.00 |
| Received By |
alange |
Date |
2006-08-25 |
Time |
09:01 |
Sent To |
|
|
| Notes |
| 2006-08-25 00:00:00 | DENIED | | | | | | | | | 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 4. SUBMIT TWO COMPLETE SETS OF | | | MIAMI-DADE PRODUCT APPROVALS USED WITH | | | THE APPROPRIATE STATE PRODUCT APPROVAL. | | | | | | 6.ALL PRODUCT APPROVALS SUBMITTED WITH | | | QUALITY ASSURANCE SHALL HAVE THE | | | FOLLOWING STATE APPROVAL ATTACHED. | | | | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A STATE PRODUCT APPROVAL | | | SHEETS THAT LISTS THE PRODUCT IDENTITY | | | NUMBER FROM THE STATE. IF THE PRODUCT | | | DOES NOT HAVE STATEWIDE APPROVAL, SUBMIT | | | AN APPLICATION FOR LOCAL PRODUCT | | | APPROVAL OR SITE SPECIFIC FORM PER RULE | | | 9B-72. SEE ATTACHMENT. | | | WWW.FLORIDABUILDING.ORG | | | | | | 7.THOSE PRODUCT APPROVALS WHICH ARE | | | REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL | | | FOR JURISDICTIONAL APPROVAL.WPB | | | AMENDMENT TO FBC 106.3.3. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. SUBMIT ONE COPY OF | | | OLD PAGES FOR REFERENCE. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET | | | OR SPECIFICATION PAGE WHERE THE CHANGES | | | CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | ART LANGE | | | CONSTRUCTION SERVICES DEPARTMENT | | | BUILDING PLANS EXAMINER | | | 561-805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-07-10 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-07-10 |
Time |
13:07 |
Rev Time |
1.50 |
| Received By |
alange |
Date |
2006-07-10 |
Time |
11:27 |
Sent To |
|
|
| Notes |
| 2006-07-10 00:00:00 | DENIED | | | | | | | | | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT | | | SHALL BE RECORDED AT PALM BEACH COUNTY | | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | | BLANK FORMS ARE AVAILABLE FROM THIS | | | OFFICE. | | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE | | | RE-RECORDED IF THE DESCRIBED IMPROVEMENT | | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | | 90 DAYS OF RECORDING. | | | | | | 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 3.SIGN OWNER/AGENT ON ENERGY CALCS | | | PER 2004 FBC. | | | | | | 4.PRODUCT APPROVALS REQUIRED FOR | | | LINTELS, SIDE LITES/FIXED GLASS AND | | | GLASS BLOCK. | | | | | | NOTE: PRODUCT APPRROVALS SUBMITTED ARE | | | NOT COMPLETE.SUBMIT NOA'S WITH THE | | | APPROPRIATE STATE PRODUCT APPROVALS | | | ATTACHED. | | | | | | 5.QUALITY ASSURANCE REQUIRED WITH ALL | | | STATE PRODUCT APPROVALS, (MIAMI-DADE) | | | FOR EXAMPLE. | | | | | | 6.ALL PRODUCT APPROVALS SUBMITTED WITH | | | QUALITY ASSURANCE SHALL HAVE THE | | | FOLLOWING STATE APPROVAL ATTACHED. | | | | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A STATE PRODUCT APPROVAL | | | SHEETS THAT LISTS THE PRODUCT IDENTITY | | | NUMBER FROM THE STATE. IF THE PRODUCT | | | DOES NOT HAVE STATEWIDE APPROVAL, SUBMIT | | | AN APPLICATION FOR LOCAL PRODUCT | | | APPROVAL OR SITE SPECIFIC FORM PER RULE | | | 9B-72. SEE ATTACHMENT. | | | WWW.FLORIDABUILDING.ORG | | | | | | 7.THOSE PRODUCT APPROVALS WHICH ARE | | | REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL | | | FOR JURISDICTIONAL APPROVAL.WPB | | | AMENDMENT TO FBC 106.3.3. | | | | | | 8.SEE ELECTRICAL REVIEW DONE FOR | | | BUILDING. | | | SUBMIT TWO SETS OF TRUSS DRAWINGS | | | FOR REVIEW PER 2004 FBC R-802.10.1 | | | | | | 9.SUBMIT TWO ORIGONAL SIGNED AND | | | SEALED SURVEYS. FS 472.025 | | | | | | NOTE:AN ELEVATION CERTIFICATE IS | | | REQUIRED PRIOR TO GETTING A CERTIFICATE | | | OF COMPLETION. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. SUBMIT ONE COPY OF | | | OLD PAGES FOR REFERENCE. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET | | | OR SPECIFICATION PAGE WHERE THE CHANGES | | | CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | ART LANGE | | | CONSTRUCTION SERVICES DEPARTMENT | | | BUILDING PLANS EXAMINER | | | 561-805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-05-24 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-05-24 |
Time |
09:40 |
Rev Time |
1.50 |
| Received By |
alange |
Date |
2006-05-24 |
Time |
09:40 |
Sent To |
|
|
| Notes |
| 2006-05-24 00:00:00 | DENIED | | | | | | | | | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT | | | SHALL BE RECORDED AT PALM BEACH COUNTY | | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | | BLANK FORMS ARE AVAILABLE FROM THIS | | | OFFICE. | | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE | | | RE-RECORDED IF THE DESCRIBED IMPROVEMENT | | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | | 90 DAYS OF RECORDING. | | | | | | 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 3.SUBMIT TWO COPIES OF ENERGY CALCS | | | PER 2004 FBC. | | | | | | 4.PRODUCT APPROVALS REQUIRED FOR | | | LINTELS, SIDE LITES/FIXED GLASS AND | | | GLASS BLOCK. | | | | | | 5.QUALITY ASSURANCE REQUIRED WITH ALL | | | STATE PRODUCT APPROVALS, (MIAMI-DADE) | | | FOR EXAMPLE. | | | | | | 6.ALL PRODUCT APPROVALS SUBMITTED WITH | | | QUALITY ASSURANCE SHALL HAVE THE | | | FOLLOWING STATE APPROVAL ATTACHED. | | | | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A STATE PRODUCT APPROVAL | | | SHEETS THAT LISTS THE PRODUCT IDENTITY | | | NUMBER FROM THE STATE. IF THE PRODUCT | | | DOES NOT HAVE STATEWIDE APPROVAL, SUBMIT | | | AN APPLICATION FOR LOCAL PRODUCT | | | APPROVAL OR SITE SPECIFIC FORM PER RULE | | | 9B-72. SEE ATTACHMENT. | | | WWW.FLORIDABUILDING.ORG | | | | | | 7.THOSE PRODUCT APPROVALS WHICH ARE | | | REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL | | | FOR JURISDICTIONAL APPROVAL.WPB | | | AMENDMENT TO FBC 106.3.3. | | | | | | 8.SUBMIT TWO SETS OF TRUSS DRAWINGS | | | FOR REVIEW PER 2004 FBC R-802.10.1 | | | | | | 9.SUBMIT TWO ORIGONAL SIGNED AND | | | SEALED SURVEYS. FS 472.025 | | | | | | 10.ENGINEERS SEALS SHALL READ | | | "LICENSED" NOT CERTIFICATE 61 G1-16.001 | | | | | | 11.ASCE 7-98 IS THE INCORRECT | | | STANDARD. | | | | | | 12.PROPERTY IS IN AN AREA OF | | | QUESTIONABLE SOILS.SUBMIT A SOILS | | | REPORT INCLUDING FOOTING | | | RECOMMENDATIONS. | | | | | | NOTE:AN ELEVATION CERTIFICATE IS | | | REQUIRED PRIOR TO GETTING A CERTIFICATE | | | OF COMPLETION. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. SUBMIT ONE COPY OF | | | OLD PAGES FOR REFERENCE. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET | | | OR SPECIFICATION PAGE WHERE THE CHANGES | | | CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | ART LANGE | | | CONSTRUCTION SERVICES DEPARTMENT | | | BUILDING PLANS EXAMINER | | | 561-805-6672 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2007-11-20 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-11-20 |
Time |
16:01 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-11-20 |
Time |
15:49 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2007-08-13 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-08-13 |
Time |
09:46 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-08-13 |
Time |
07:03 |
Sent To |
PC |
|
| Notes |
| 2007-08-13 09:46:36 | | | | | | | REVISION DENIED/INCOMPLETE INFORMATION | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE | | | COMPLIANCE AND RESUBMIT FOR REVIEW | | | | | | 1}A GROUNDING ELECTRODE CONDUCTOR IS REQUIRED AT THE | | | SEPARATE STRUCTURE (CABANA)PER 250.32, SIZED PER | | | 250.66 AND TIED TO FOOTER STEEL PER 250.53(A)(3). THE | | | PERMIT SET OF PLANS HAD THIS SHOWN CORRECTLY, BUT HAS | | | BEEN DELETED FROM THE REVISED PLAN SUBMITTED. | | | | | | 2} THE PANEL AT THE CABANA IS REQUIRED TO HAVE A | | | DISCONNECTING MEANS PER 225.31, LOCATED PER 225.32. THE | | | CABANA PANEL NOW IS LISTED AS A "MAIN LUG" PANEL, NOT | | | IN COMPLIANCE, UNLESS ANOTHER DISCONNECTING MEANS IS | | | INSTALLED AS PER THE ABOVE LISTED ARTICLES. THE | | | DISCONNECT MUST BE LOCATED ON THE PLAN AND ON THE RISER | | | DIAGRAM. | | | | | | 3} THERE IS NO OVERCURRENT PROTECTION FOR THE POOL | | | PANEL FEEDER SHOWN IN THE METER/MAIN PANEL. INDICATE | | | THE SIZE OF THE OCP PER 310.16 OR 310.15(B)(6). | | | | | | 4} THE 10 K AHU LISTED ON THE PANEL SCHEDULE IS SHOWN | | | ON A 50 AMP CIRCUIT BREAKER, AND DOES NOT COMPLY WITH | | | THE REQUIREMENT FOR THE BRANCH CIRCUIT RATING OF 125%, | | | 424.3(B). THIS WAS A REDLINED ITEM ON THE PERMIT SET, | | | NOW MUST BE CORRECTED AS THIS REVISION IS INTENDED AS | | | THE LAST FOR RECORD RETENTION. | | | | | | 5} GIVEN THE LOCATION OF THE AHU IN THE ATTIC,ALSO | | | SHOW COMPLIANCE WITH THE REQUIRED DISCONNECT PER | | | 440.14,RECEPTACLE PER 210.63, LIGHT PER 210.70(A) | | | (3). | | | | | | 6} THE LOAD CALCULATION FORMAT HAS BEEN CHANGED FROM | | | THE ORIGINAL PERMITTED SET. PROVIDE LOAD CALCULATIONS | | | PER ARTICLE 220 PART II, STANDARD OR PART III OPTIONAL, | | | INDICATE METHOD USED. | | | | | | 7} THE POOL EQUIPMENT LOAD HAS BEEN MOVED FROM THE | | | CABANA PANEL TO THE HOUSE PANEL. THIS IS CONTRARY TO | | | THE RISER WHICH NOW SHOWS A POOL PANEL. PLEASE PROVIDE | | | A PANEL SCHEDULE FOR THE POOL PANEL SO THAT | | | BRANCH/FEEDER CIRCUIT CONDUCTOR AND OVER CURRENT | | | PROTECTION COMPLIANCE MAY BE REVIEWED PER 106.3.5.4 FBC | | | AS AMENDED. | | | | | | 8} THE 200 AMP EXISTING HOUSE PANEL HAS NOW BEEN LISTED | | | AS A MAIN LUG PANEL ON THE RISER. THAT PANEL IS LISTED | | | AS A 200 AMP MAIN BREAKER PANEL ON THE PERMIT SET OF | | | DRAWINGS. IF THAT PANEL WAS CHANGED IT WAS DONE OUTSIDE | | | OF THE SCOPE OF THIS PERMIT. PLANS AND ANOTHER | | | APPLICATION OR REVISION INDICATING THE INCREASED VALUE | | | FOR LABOR AND MATERIAL, MUST BE SUBMITTED. 105.14 FBC | | | AS AMENDED. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW. | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-08-24 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-08-24 |
Time |
11:09 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2006-08-21 |
Time |
17:33 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-06-25 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-06-25 |
Time |
12:23 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-06-25 |
Time |
11:48 |
Sent To |
P |
|
| Notes |
| 2006-06-25 00:00:00 | *********** UNSAT 2ND REVIEW ********** | | | | | | ** PLEASE SEE SOME NOTES FROM PREVIOUS | | | REVIEW AND SOME NEW NOTES DUE TO CHANGES | | | AND ITEMS REVIEWED ON PLANS. | | | | | | | | | 1) NOTE: PLEASE SEE RISER SHOWS NEW 150A | | | FEED TO CABANA NOW BEING FED DIRECTLY | | | FROM THE EXISTING METER. PLEASE SEE | | | MAINS ARE NOT GROUPED AS REQUIRED. PLANS | | | SHOWS A MAIN AT THE CABANA AND A MCB | | | PANEL??? | | | PLEASE KNOW, THE MCB IS REQUIRD AT | | | CABANA, HOWEVER THE 150A MAIN DISCONNECT | | | IS REQUIRED TO BE GROUPED WITH THE | | | EXISTING MCB 200A PANEL. | | | 230.72. | | | PLEASE SEE THE 150A DISCONNECT IS SHOWN | | | AS WP ON RISER AND PLANS INDICATE AN | | | ADDITIONAL DISCONNECT IN THE LAUNDRY RM | | | WITH THE MCB PANEL. | | | | | | 2) NOTE: PLEASE INDICATE THE SIZE OF THE | | | NEW METER CAN AS THE EXISTING 200A METER | | | CAN NO LONGER BE USED. | | | 215.5 | | | | | | 3) NOTE: PLEASE KNOW, BSAED ON THE | | | INCREASE IN SERVICE SIZE AND THE | | | INCREASED SEC'S, THE EXISTING GROUNDING | | | ELECTRODE CONDUCTOR SHALL BE INCREASED | | | PER 310.15B6,250.66 (#2 MIN). | | | | | | 4) NOTE: PLEASE SEE MISSING GROUNDING | | | ELECTRODE SYSTEM REQUIRED AT DETACHED | | | BUILDING/CABANA. 250.32. NEW FOOTER | | | STEEL, CWP ETC. | | | 250.50 | | | | | | 5) NOTE: PLEASE SEE RISER SHOWS | | | "EQUIPMENT GROUNDING CONDUCTOR(S)" FROM | | | THE METER TO THE FIRST MEANS OF | | | DISCONNECT(S). PLEASE SEE 250.6,250.24B, | | | AS THE EUP GRNDS ARE ONLY INSTALLED | | | AFTER THE FIRST MEANS OF DISC. | | | | | | 6) NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW SERVICE EQUIPMENT. | | | 110.9,215.5 | | | | | | 7) NOTE: PLEASE SEE A DISCONNECTING | | | MEANS FOR THE LTS IN OUTSIDE LOGGIA | | | AREA. THE POWER FOR THESE LTS BEING | | | SHOWN ON A 3-WAY FROM MAIN HOUSE SHALL | | | ORIGINATE FROM CABANA PANEL. | | | 225.31,225.34 | | | | | | 8) NOTE: PLEASE SEE MISSING DISCONNECT | | | FOR CU #1, 440.11 | | | | | | 9) NOTE: PLEASE SEE MISSING REQUIRED GFI | | | RECEPT FOR CU. 210.63,210.8 | | | | | | 10) NOTE: PLEASE SEE MIN OCP FOR 10KW | | | AHU SHALL BE SIZED AT A MIN OF 125%. | | | 424.3B | | | PLEASE SEE THE EXISTING IN MAIN HOUSE | | | SHALL BE VERIFIED AND CORRECTED IF NOT | | | 60A MIN. | | | NFPA-73 | | | | | | 11) NOTE: PLEASE SEE LOAD CALCULATIONS | | | INDICATES THE CU LOADS AS FIGURED IN, | | | WHEN THIS SHOULD DICTATE THE AHU/HEAT | | | LOADS. | | | PLEASE CORRECT.220.31B, 220.21, ETC | | | | | | 12) NOTE: PLEASE SEE THE "STUDIO" RM | | | SHALL CONTAIN A SMOKE DETECTOR INSIDE | | | AND OUTSIDE THIS ROOM. THIS IS | | | CONSIDERED ADN ADAPTABLE SLEEPING RM. | | | NFPA-72 11.5.1.1 | | | | | | 13) NOTE: PLEASE SEE 210.12B AND NOTE | | | THE ARC FAULT PROTECTION WILL ALSO BE | | | REQUIRED FOR THE "STUDIO RM", AS THIS IS | | | ALSO CONSIDERED AN ADAPTABLE SLEEPING | | | RM. | | | | | | 14) NOTE: PLEASE SEE THE MIN LOAD/KW TO | | | BE FIGAURED FOR DRYERS SHALL BE 5KW PER | | | 220.18. PLEASE ADJUST CABANA PANEL, MAIN | | | HOUSE AND LOAD CALCS. | | | 215.5 | | | | | | 15) NOTE: PLEASE SEE PLANS INDICATE A | | | "ON-DEMAND" WATER HEATER AT CABANA, YET | | | THE LOAD INDICATED IS SHOWN AS 4.5KW ON | | | PANEL SCHEDULE. PLEASE VERIFY SIZE OF | | | UNIT BEING INSTALLED AND SUBMIT | | | MANUFACTURE SPEC/CUT SHEETS FOR UNIT | | | BEING INSTALLED. PLEASE KNOW THIS UNIT | | | SHALL BE LISTED BY A NRTL. | | | 215.5 | | | FBC 106.1.2 ADMIN SECT. | | | | | | 16) NOTE: PLEASE SEE FS 471.025, NO HAND | | | DRAWN CHANGES MAY BE DONE ON PLANS WHICH | | | ARE ALREADY SIGNED,DATED AND SEALED BY | | | THE ENGINEER OF RECORD. | | | (RISER, 100A TO 150A.) | | | | | | 17) NOTE: PLEASE SEE BUIDLING REVIEW | | | COMMENTS TO FOLLOW AS THE SUBMITTED | | | "TRUSS" PACKAGE CONTAINS A "RUBBER | | | STAMP"AND MANY OTHER SHEETS ARE SEALED | | | "PHOTO-COPIES" OF THE "RUBBER STAMPED | | | SIGNATURE" IN LEIU OF THE REQUIRED | | | ORIGINAL SIGNATURE AND DATE FROM THE | | | ENGINEER. FS 471.025 | | | PLEASE ALSO SEE SEAL IS NO LONGER | | | ACCELTABLE PER FAC 61G15-23.001. THE | | | WORDING IN SAID SEAL SHALL CONTAIN THE | | | WORDING OF "LICENSE" AS "CERTIFICATE" | | | CAN NOT BE USED. | | | THIS RULE WAS PASSED IN FEB 04 AND THE | | | EXTENSION GIVEN TO ENGINEERS WAS ONLY TO | | | DEC 31ST, 2005. | | | | | | **THIS IS REQUIRED** | | | | | | 18) NOTE: PLEASE SEE FS553.80(2)(B) WITH | | | RESPECT TO REPEAT COMMENTS. THIS IS ONLY | | | A NOTE AT THIS TIME. | | | | | | | | | ** PLEASE SUBMIT THE ABOVE INFORMATION | | | FOR REVIEW. IF THERE ARE ANY QUESTIONS, | | | OR COMMENTS, PLEASE DO NOT HESITATE IN | | | CONTACTING THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-05-16 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-05-16 |
Time |
09:28 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2006-05-16 |
Time |
06:34 |
Sent To |
P |
|
| Notes |
| 2006-05-16 00:00:00 | | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} SHEET E-1.1 SHOWS A NEW 350 AMP | | | SERVICE. SHEET E-1.2 RISER HAS A 200 AMP | | | SERVICE, PLEASE CORRELATE. SEE 225.31 | | | FOR REQUIREMENTS FOR THE DISCONNECT AT | | | THE CABANA, AND 250.32 FOR GROUNDING | | | REQUIREMENTS OF SAME. | | | | | | 2} THE #6 FEEDERS TO THE INTENDED 100 | | | AMP CABANA PANEL ARE TOO SMALL AND MUST | | | COMPLY WITH THE MINIMUM SIZE IN TABLE | | | 310.15(B)(6). | | | | | | 3} THE PANEL LOCATION IN THE CABANA IS | | | IN VIOLATION OF 110.26. THE WASHER IS IN | | | THE CLEAR WORK SPACE. | | | | | | 4} THE BATHROOM MUST COMPLY WITH | | | 210.52(D), 3' SPACING, AND 210.11(C)(3), | | | DEDICATED CIRCUIT. | | | | | | 5} IF THE SMALL APPLIANCE CIRCUIT IS | | | INDICATING THERE IS A KITCHEN IN THE | | | CABANA, THEN IT MUST HAVE TWO, PER | | | 210.11(C)(1), AND ENTERED INTO THE | | | CALCULATIONS. | | | | | | 6} THE GENERAL LIGHTING CIRCUITS IN THE | | | CABANA PANEL SCHEDULE LIST # 14 | | | CONDUCTORS ON A 20 AMPERE BREAKER IN | | | VIOLATION OF 310.16. | | | | | | 7} THE RISER INDICATES THAT THE CABANA | | | PANEL IS BEING FED FROM THE HOUSE PANEL, | | | BUT IT IS NOT LISTED IN THE HOUSE PANEL | | | SCHEDULE. | | | | | | 8} PLEASE USE THE LARGER LOAD WHEN | | | COMPUTING THE HEAT-A/C LOADS, THEPER | | | 220.21. ALSO SEE 220.30 OR 220.31(B), | | | INDICATE WHICH ARTICLE IS USED FOR THE | | | CALCULATIONS. | | | | | | 9} SEE ARTICLE 210.8(A)(7) FOR GFI | | | REQUIREMENTS AT WET BAR/SINK. | | | | | | 10} THE ENGINEER OF RECORD SEALED THE | | | PLANS WITH ASEAL THAT IS NO LONGER | | | VALID. SEE 61G15-23.002 FAC. | | | | | | PLEASE PROVIDE WRITTEN RESPONSES TO ALL | | | COMMENTS TO EXPEDITE PLAN REVIEW OF THE | | | RESUB. | | | | | | IF THERE ARE QUESTIONS , PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2007-11-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-15 |
Time |
10:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-11-15 |
Time |
10:50 |
Sent To |
E |
|
| Notes |
| 2007-11-15 10:50:40 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2007-08-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-03 |
Time |
09:05 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-03 |
Time |
09:05 |
Sent To |
E |
|
| Notes |
| 2007-08-03 09:05:55 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-08-31 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-08-31 |
Time |
12:04 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-08-31 |
Time |
12:04 |
Sent To |
B |
|
| Notes |
| 2006-08-31 00:00:00 | PLANS TO ALANGE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-08-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-21 |
Time |
16:36 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-21 |
Time |
16:36 |
Sent To |
E |
|
| Notes |
| 2006-08-21 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-08-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-14 |
Time |
08:55 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-14 |
Time |
08:55 |
Sent To |
Z |
|
| Notes |
| 2006-08-14 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-06-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-22 |
Time |
10:33 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-22 |
Time |
10:33 |
Sent To |
E |
|
| Notes |
| 2006-06-22 00:00:00 | TO "E" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-05-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-11 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-11 |
Time |
16:03 |
Sent To |
E |
|
| Notes |
| 2006-05-11 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-05-24 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-05-24 |
Time |
09:40 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-04-25 |
Time |
13:52 |
Sent To |
|
|
| Notes |
| 2006-04-25 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2006-05-18 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-05-18 |
Time |
12:57 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2006-05-18 |
Time |
12:57 |
Sent To |
B |
|
| Notes |
| 2006-05-18 00:00:00 | NO MECHANICAL PLANS SUBMITTED, AND NO | | | MECHANICAL PERMIT NUMBER APPLIED FOR AT | | | THIS TIME. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2006-07-08 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-07-08 |
Time |
10:08 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-07-08 |
Time |
10:08 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-05-18 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-05-18 |
Time |
08:49 |
Rev Time |
1.33 |
| Received By |
mperson |
Date |
2006-05-18 |
Time |
08:49 |
Sent To |
M |
|
| Notes |
| 2006-05-18 00:00:00 | ******DENIED****** | | | REFERENCE: FBC-2004 PLUMBING | | | | | | THE FOLLOWING INFORMATION IS REQUIRED | | | FOR PLUMBING PLAN REVIEW FOR A PERMIT: | | | | | | 1. INDICATE ON SHEET A-1 AND SHEET A-2 | | | THE OUTSIDE SHOWER DRAIN PIPE, DRAIN | | | PIPE SIZE AND WHERE IT IS DRAINING TO. | | | 2. ON SHEET A-6 PLUMBING RISER DIAGRAM | | | THERE INDICATES A FUTURE OUTDOOR SINK. | | | PLEASE INDICATE ON SHEET A-2 THE | | | LOCATION OF THE FUTURE OUTDOOR SINK. | | | 3. ON SHEET A-6 PLUMBING RISER DIAGRAM | | | THE FOLLOWING IS REQUIRED FOR THE FUTURE | | | OUTDOOR SINK. | | | (A) 704.4 FUTURE FIXTURES. DRAINAGE | | | PIPING FOR FUTURE FIXTURES SHALL | | | TERMINATE WITH AN APPROVED CAP OR PLUG. | | | (B) 905.6 VENT FOR FUTURE FIXTURES. | | | WHERE THE DRAINAGE PIPING HAS BEEN | | | ROUGHED-IN FOR FUTURE FIXTURES, A | | | ROUGH-IN CONNECTION FOR A VENT SHALL BE | | | INSTALLED. THE VENT SIZE SHALL BE NOT | | | LESS THAN ONE-HALF THE DIAMETER OF THE | | | ROUGH-IN DRAIN TO BE SERVED. THE VENT | | | ROUGH-IN SHALL CONNECT TO THE VENT | | | SYSTEM, OR SHALL BE VENTED BY OTHER | | | MEANS AS PROVIDED FOR IN THIS CHAPTER. | | | THE CONNECTION SHALL BE IDENTIFIED TO | | | INDICATE THAT IT IS A VENT. | | | 4. ON SHEET A-6 PLUMBING RISER DIAGRAM | | | THE BRANCH DRAIN AND THE DRAINAGE STACK | | | ARE SIZED INCORRECTLY FOR THE WASHING | | | MACHINE, THE FOLLOWING IS REQUIRED FOR | | | THE SIZING OF THE WASHING MACHINE. | | | (A) 406.3 WASTE CONNECTIONS.THE TRAP AND | | | FIXTURE DRAIN FOR AN AUTOMATIC CLOTHES | | | WASHER SHALL BE A MINIMUM OF 2 INCHES | | | (51MM) IN DIAMETER. THE AUTOMATIC | | | CLOTHES WASHER FIXTURE DRAIN SHALL | | | CONNECT TO A BRANCH DRAIN OR DRAINAGE | | | STACK A MINIMUM OF 3 INCHES (76MM) IN | | | DIAMETER | | | (B) 802.4 STANDPIPES.STANDPIPES SHALL BE | | | INDIVIDUALLY TRAPPED. STANDPIPES SHALL | | | EXTEND A MINIMUM OF 18 INCHES (457MM) | | | AND A MAXIMUM OF 42 INCHES (1066MM) | | | ABOVE THE TRAP WEIR. ACCESS SHALL BE | | | PROVIDED TO ALL STANDPIPES AND DRAINS | | | FOR RODDING (NOTE: THE INDICATION OF THE | | | STAND PIPE ON CORRECTED PLBG. RISER | | | DIAGRAM) | | | 5. PLEASE NOTE THE CORRECTED CLEANOUT | | | LOCATIONS ON A-6 PLBG. RISER DIAGRAM AND | | | THE FOLLOWING CODE REQUIREMENTS FOR | | | CLEANOUTS | | | (A) 708.3.4 BASE OF STACK. A CLEANOUT | | | SHALL BE PROVIDED AT THE BASE OF EACH | | | WASTE OR SOIL STACK | | | (B) 708.3.5 BUILDING DRAIN AND BUILDING | | | SEWER JUNCTION. THERE SHALL BE A | | | CLEANOUT NEAR THE JUNCTION OF THE | | | BUILDING DRAIN AND THE BUILDING SEWER. | | | (C) 708.7 MINIMUM SIZE. CLEANOUTS SHALL | | | BE THE SAME NOMINAL SIZE AS THE PIPE | | | THEY SERVE UP TO 4 INCHES (102MM). | | | (D) 708.9 ACCESS. ACCESS SHALL BE | | | PROVIDED TO ALL CLEANOUTS.(NOTE THE | | | LOCATION OF THE WASHING MACHINE | | | CLEANOUT) | | | 6. PLEASE NOTE THE FOLLOWING WILL BE | | | REQUIRED FOR THE GAS DRYER AND GAS WATER | | | HEATER. | | | NOTE: GAS PERMIT REQUIRED. GAS CONTRAC- | | | TOR TO SUBMIT PLANS WITH PERMIT APPLICA- | | | TION. ALL GAS INSPECTIONS TO BE COMPLETE | | | BEFORE FINAL INSPECTION. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2006-08-19 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-08-19 |
Time |
09:33 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-08-19 |
Time |
09:33 |
Sent To |
I |
|
| Notes |
| 2006-08-19 00:00:00 | NOTE: THE PROPOSED CABANA CANNOT EXCEED | | | THE MAXIMUM FLOOR AREA OF 1000 SQUARE | | | FEET AND CANNOT BE USED FOR LIVING | | | SPACE. | | | | | | NOTE: THE PROPOSED WALL/GATE/FENCE MUST | | | HAVE A SEPARATE PERMIT WITH CITY OF WEST | | | PALM BEACH UTILITY ESEMENT APPROVAL. | | | | | | NOTE: | | | THE PROPOSED A/C SHL NOT BE CLOSER THAN | | | 11FT FROM REAR PROPERTY LINE. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2006-05-11 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-05-11 |
Time |
09:53 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-05-11 |
Time |
09:52 |
Sent To |
I |
|
| Notes |
| 2006-05-11 00:00:00 | NOTE: THE PROPOSED CABANA CANNOT BE USED | | | AS A LIVING SPACE. SF7 |
|
|