| Plan Review Stops For Permit 06040775 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2006-09-05 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2006-09-05 |
Time |
15:16 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2006-09-05 |
Time |
15:16 |
Sent To |
PC |
|
| Notes |
| 2006-09-05 00:00:00 | | | | SUBMIT ELECTRICAL UNDER SEPERATE PERMIT | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-07-24 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2006-07-24 |
Time |
07:20 |
Rev Time |
0.50 |
| Received By |
amorse |
Date |
2006-07-24 |
Time |
07:20 |
Sent To |
PC |
|
| Notes |
| 2006-07-24 00:00:00 | | | | | | | DENIED | | | | | | 1) 2 SIGNED AND SEALED COPIES OF THE | | | SOIL REPORT MUST BE SUBMITTED WITH THE | | | PERMIT APPLICATION, AFTERS APPROVAL ONE | | | COMPLETE SET OF SUBMITTALS WILL BE | | | RETURNED WITH PERMIT FOR CONSTRUCTION | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-05-22 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2006-05-22 |
Time |
07:39 |
Rev Time |
1.00 |
| Received By |
amorse |
Date |
2006-05-22 |
Time |
07:39 |
Sent To |
PC |
|
| Notes |
| 2006-05-22 00:00:00 | | | | | | | DENIED | | | | | | 1) STRUCTURE IS IN AN AREA OF | | | QUESTIONABLE SOILS AND AS SUCH REQUIRES | | | A SOIL REPORT | | | | | | 2) THERE ARE ELECTRICAL CONTROLS ON | | | DRAWING THAT WILL REQUIRE ELECTRICAL | | | CONTRACTOR UNDER THIS PERMIT OR WITH | | | SEPARATE PERMIT TIED TO THIS PERMIT | | | NUMBER | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
N |
Date |
2006-09-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-09-05 |
Time |
14:58 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-09-05 |
Time |
14:58 |
Sent To |
B |
|
| Notes |
| 2006-09-05 00:00:00 | *** UNSAT *** | | | | | | 1) NOTE: PLEASE SEE ELECTRICAL PLANS AND | | | PERMIT APPLICATION IS NOW BEING | | | SUBMITTED WITH BUILDING PERMIT. PLEASE | | | KNOW, IT IS OK, FOR THE ELECTRICAL PLANS | | | TO BE SUBMITTED WITH BUILDING , HOWEVER | | | SINCE THE ELECTRICAL CONTRACTORWAS NOT | | | SIGNED ON BUILDING CONTRACTORS ORIGINAL | | | PERMIT APPLICATION, THE ELECTRICAL | | | CONTRACTOR MAY COME IN AFTER BUILDING | | | PERMIT IS ISSUED, REFERENCE THE BUILDIGN | | | PERMIT AND AS LONG AS THE ELECTRICAL | | | REVIEW IS "PASSED", THEN THE PERMIT IS | | | DONE AS A TURNAROUND PERMIT. | | | PLEASE SEETHE FOLLOWING ELECTRICAL | | | COMMENTS. | | | | | | 2) NOTE: PLEASE SUBMIT LOAD CALCULATIONS | | | FOR NEW ADDED LOADS ON HE EXISTING | | | ELECTRICAL SERVICE. | | | 220.31 | | | | | | 3) NOTE: PLEASE SEE AN ADDITIONAL SWITCH | | | IS BEING SHOWN ON THE PLANS FOR ?? | | | SOMETHING, BUT IT IS NOT SHOWN WHAT THIS | | | IS SWITCHING. | | | | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-09-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-05 |
Time |
08:32 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-05 |
Time |
08:32 |
Sent To |
B |
|
| Notes |
| 2006-09-05 00:00:00 | TO "AMORSE" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-07-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-07-21 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-07-21 |
Time |
10:51 |
Sent To |
B |
|
| Notes |
| 2006-07-21 00:00:00 | TO "AMORSE" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-04-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-25 |
Time |
11:11 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-25 |
Time |
11:11 |
Sent To |
B |
|
| Notes |
| 2006-04-25 00:00:00 | TO "MISC" BOX#2 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2006-05-22 |
Time |
|
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-21 |
Time |
09:35 |
Sent To |
|
|
| Notes |
| 2006-04-21 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2006-04-24 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-04-24 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-04-24 |
Time |
11:19 |
Sent To |
I |
|
| Notes |
|
|