Plan Review Details - Permit 06040670
| Plan Review Stops For Permit 06040670 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-05-15 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-05-15 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-05-15 |
Time |
10:22 |
Sent To |
|
|
| Notes |
| 2006-05-15 00:00:00 | ****CORRECTIONS**** | | | ****PLAN CHECK ONLY**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 | | | EXISTING BUILDING CODE | | | FBC*CITY OF WEST PALM BEACH | | | AMENDMENTS TO THE FBC2004 | | | | | | 1.)IMPACT FEES TO PALM BEACH COUNTY | | | MAY BE DUE.THE PLANS MUST BE STAMPED | | | AND THE RECEIPT ATTACHED TO THE | | | APPLICATION.233-5025 | | | | | | 2.)DECLARE THE OCCUPANCY | | | CLASSIFICATION FBC3, BUILDING TYPE FBC6, | | | AND AREA CALCULATIONS, INCLUDING | | | EXISTING AREA, PROPOSED ADDITION, AND | | | NEW TOTAL. | | | | | | 3.)DECLARE OCCUPANT LOAD, FBC1004. | | | | | | 4.)PROVIDE PRODUCT APPROVALS FOR THE | | | DOORS, WINDOWS, ROOF.FLORIDA STATE OR | | | LOCAL PRODUCT APPROVAL REQUIRED, | | | FAC9B72.WWW.FLORIDABUILDING.ORG | | | | | | 5.)DESIGNER OF RECORD IS TO REVIEW THE | | | PRODUCT APPROVALS, FBC*106.3.3. | | | | | | 6.)IS THE EQUIPMENT OUTDOORS OR IN A | | | BUILDING.IF IT IS IN A BUILDING, SHOW | | | THE DISTANCE BETWEEN THE TWO BUILDINGS | | | AND SHOW FBC TABLE 602 COMPLIANCE.IF | | | IT IS NOT IN A BUILDING, NOTE ON THE | | | PLAN. | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-05-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-05-17 |
Time |
13:08 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-05-17 |
Time |
12:39 |
Sent To |
|
|
| Notes |
| 2006-05-17 00:00:00 | *** UNSAT *** | | | | | | PLEASE KNOW, PLANS HAVE ONLY BEEN | | | SUBMITTED FOR "PLAN REVIEW" AND AHVE NOT | | | BEEN SUBMITTED FOR PERMIT. | | | | | | 1) NOTE: PLEASE SEE 240.21 FOR WHAT | | | APPEARS TO BE "TAPPED" CONDUCTORS FROM | | | THE 600A MAIN DISCONNECT AS SHOWN TO | | | X-FORMER AND NEW PANEL "L". | | | PLEASE ALSO CLARIFY THE TAP FOR OTHER | | | EXIST CONTROL PANEL. | | | 240.4,310.16. | | | DOES THIS EXISTING 600A MAIN SERVICE | | | DISCONNECT CONTAIN OCP FOR THE | | | TRANSFORMER? | | | THE SCENERIO IS UNCLEAR AT THIS TIME. | | | | | | 2) NOTE: PLEASE SEE CIRCUITING FOR EXT | | | LT NOT SHOWN. | | | THIS ITEM COULD BE REDLINHED, HOWEVER | | | PLANS HAVE NOT BEEN SUBMITTED FOR | | | PERMIT. | | | | | | | | | PLEASE SEE ANY OTHER COMMENTS FROM OTHER | | | TRADES WHICH MAY AFFECT ELECTRICAL | | | PLANS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELEECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2006-06-27 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2006-06-27 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
2006-06-27 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2006-06-16 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2006-06-16 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2006-06-16 |
Time |
11:03 |
Sent To |
|
|
| Notes |
| 2006-06-16 00:00:00 | 1. SITE PLAN DOES NOT ILLUSTRATE ANY NEW | | | OR EXISTING FIRE HYDRANTS. PLEASE | | | DISPLAY NECESSARY INFORMATION. | | | | | | 2. PLEASE INDICATE OCCUPANCY TYPE AND | | | AND PROPOSED OCCUPANT LOAD FOR PERMITTED | | | AREA. | | | | | | 3. ARE ANY IDENTIFIERS OR ADDRESS | | | PLANNED TO LOCATE THIS AREA SHOULD AN | | | EMERGENCY DEVELOP. NO INFORMATION SHOWN | | | ON ANY OF THE ELEVATIONS. | | | | | | 4. NO PORTABLE FIRE EXTINGUISHER SHOWN | | | ON THE DRAWINGS. | | | | | | 5. PLEASE EXPLAIN CONROL ROOM NOTE. THE | | | CONTROL ROOM IS USED FOR WHAT PURPOSE | | | AND FOR WHAT SPECIFIC AREA. | | | | | | 6. DEMOLITION, CONTRUCTION, AND | | | RENOVATION TO COMPLY WITH NFPA 241. | | | | | | MIKE CARSILLO, CHIEF FIRE PREVENTION | | | OFFICER | | | 804-4709 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-06-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-27 |
Time |
08:55 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-19 |
Time |
09:45 |
Sent To |
|
|
| Notes |
| 2006-05-04 00:00:00 | TO "COMM" BD#20 | | 2006-04-19 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2006-06-14 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-06-14 |
Time |
07:09 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-06-14 |
Time |
07:09 |
Sent To |
|
|
| Notes |
|
|
|