| 2006-04-17 00:00:00 | PROJECT REQUIRES ADDRESSING |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2006-11-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-11-13 |
Time |
08:16 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-11-13 |
Time |
08:16 |
Sent To |
|
|
| Notes |
| 2006-11-13 08:21:44 | CHANGED TRUSS MANUFACTURER. REVISED TRUSS DRAWINGS ARE | | | OK. CHANGE WAS MADE BEFORE ANY PERMITS WERE ISSUED | | | UNDER THE MASTER. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2006-11-03 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-11-03 |
Time |
13:10 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-11-03 |
Time |
13:10 |
Sent To |
|
|
| Notes |
| 2006-11-03 13:30:18 | DENIED | | | | | | 1) TRUSS DRAWINGS AND LAYOUT HAVE BEEN REVIEWED AND | | | ACCEPTED BY HUSTAD ENGINEERING, HOWEVER, THE DESIGNER | | | OF RECORD IS ROBERT H. BRAIDO JR. OF PEACOCK AND LEWIS. | | | THERE IS NO INDICATION ON THE PLANS THAT HUSTAD | | | ENGINEERING IS THE ENGONEER OF RECORD FOR THIS PROJECT. | | | HAVE TRUSS DRAWINGS AND LAYOUTS REVIEWED AND ACCEPTED | | | BY THE DESIGNER OF RECORD OR SUBMIT SIGNED AND SEALED | | | LETTERS FROM THE ENGINEER AND FROM THE ARCHITECT | | | CERTIFYING THAT HUSTAD ENGINEERING IS THE STRUCTURAL | | | DESIGNER OF RECORD FOR THIS PROJECT. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2006-10-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-10-24 |
Time |
12:49 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-10-24 |
Time |
12:49 |
Sent To |
|
|
| Notes |
| 2006-10-24 14:11:03 | REVISION TO CHANGE TRUSSES IS DENIED | | | | | | 1) TRUSS DRAWINGS AND LAYOUT ARE REQUIRED TO BE | | | REVIEWED AND APPROVED BY THE DESIGNER OF RECORD FOR THE | | | PROJECT. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2006-08-02 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-08-02 |
Time |
13:30 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-08-02 |
Time |
13:30 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-07-12 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-07-12 |
Time |
16:21 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-07-12 |
Time |
16:21 |
Sent To |
E |
|
| Notes |
| 2006-07-12 00:00:00 | DENIED | | | | | | 1) SHEET A1.0 DOES NOT HAVE A TITLE | | | BLOCK. FAC 61G1-16.004 A TITLE BLOCK | | | MUST APPEAR ON ALL ARCHITECTURAL OR | | | INTERIOR DESIGN DRAWINGS AND | | | SPECIFICATION IDENTIFICATION SHEETS. | | | | | | 2) FBC TABLE 1607.1 REQUIRES TRUSSES TO | | | HAVE A MINIMUM BOTTOM CORD LIVE LOAD OF | | | 10 PSF. A BC LIVE LOAD OF 0.0 PSF IS | | | SPECIFIED ON THE TRUSS DRAWINGS. THE | | | TRUSS COVERSHEET SPECIFIES 10 PSF. | | | | | | 3) THE BOTTOM CORD DEAD LOAD IS | | | SPECIFIED AS 5 PSF ON THE TRUSS | | | COVERSHEET AND 15 PSF ON THE TRUSS | | | DRAWINGS. | | | | | | 4) THE TRUSS COVERSHEET REFERENCES THE | | | 2001 FBC. THE PROJECT IS UNDER THE 2004 | | | FBC. | | | | | | NOTE: IMPACT FEES AND NOC WILL BE | | | REQUIRED FOR EACH PERMIT APPLIED FOR | | | UNDER THE MASTER. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-05-10 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-05-10 |
Time |
14:41 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-05-10 |
Time |
14:41 |
Sent To |
|
|
| Notes |
| 2006-05-10 00:00:00 | DENIED BY BUILDING | | | | | | 1) SUBMIT A TYPICAL DRAINAGE PLAN | | | SHOWING COMPLIANCE WITH 2004 FBC R401.3. | | | INDIVIDUAL DRAINAGE PLANS WILL BE | | | REQUIRED FOR EACH PERMIT APPLIED FOR | | | UNDER THE PROJECT. | | | | | | 2) IMPACT FEES AND NOC WILL BE REQUIRED | | | FOR EACH PERMIT UNDER PROJECT. | | | | | | 3) THE WALL SECTION ON S2.01 SPECIFIES | | | TWO COURSES OF BOND BEAM WITH ONE #7 IN | | | EACH COURSE. THE BEAM SCHEDULE ON S2.02 | | | INDICATES ONE #5 IN EACH COURSE. PLEASE | | | CORRECT. | | | | | | 4) THE ENERGY CALCULATION FORM IS | | | REQUIRED TO USE WORST-CASE CALCULATIONS | | | FOR A MASTER PROJECT. SEE FBC | | | 13-600.2.A.5. | | | | | | 5) THE TRUSS ENGINEER'S EMBOSSED STAMP | | | IS REQUIRED TO HAVE THE WORDING CHANGED | | | FROM "CERTIFICATE" TO "LICENSE". | | | | | | 6) FBC TABLE 1607.1 REQUIRES TRUSSES TO | | | HAVE A MINIMUM BOTTOM CORD LIVE LOAD OF | | | 10 PSF. | | | | | | 7) THE DESIGN LOAD SCHEDULE ON S2.03, | | | THE DESIGN LOADS ON THE TRUSS DRAWINGS | | | AND THE DESIGN LOAD ON THE TRUSS LAYOUT | | | DO NOT CONCUR. PLEASE CORRECT. | | | | | | 8) THE UPLIFT FOR TRUSSES T2B, T3B AND | | | T4B AT BEARING POINTS R1 AND R4 HAVE | | | UPLIFTS ON THE ENDS THAT EXCEED THOSE | | | LISTED ON S2.03. | | | | | | 9) TRUSS T6 HAS AN UPLIFT OF 636# ON THE | | | LEFT END WHICH EXCEEDS THE 510# LISTED | | | ON S2.03. | | | | | | 10) SUBMIT FLORIDA PRODUCT APPROVAL FOR | | | THE "USP" THD210-2 HANGER. | | | | | | 11) THE TABLE ON S3.01 SPECIFIES | | | ALUMINUM SOFFITS AND THE SECTION ON | | | S2.01 INDICATES STUCCO ON METAL LATH AT | | | THE SOFFIT. PLEASE CORRECT. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2006-07-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-07-15 |
Time |
10:21 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-07-15 |
Time |
09:49 |
Sent To |
P |
|
| Notes |
| 2006-07-15 00:00:00 | STAMPED ELECTRICAL PLANS, OK. | | | | | | ANY REVISONS TO THESE MUST BE DONE UNDER | | | EACH PERMITTED SFR. | | | MAY NOT REVISE THE MASTER. | | | PLANS ROUTED TO PLUMB TO KEEP PLANS | | | WITH THE OTHER MASTER MODEL AS NO OTHER | | | REVIEWS WERE DONE ON OTHER MASTER MODEL. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-04-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-04-27 |
Time |
15:26 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-04-27 |
Time |
15:26 |
Sent To |
M |
|
| Notes |
| 2006-04-27 00:00:00 | ***** UNSAT ***** | | | | | | MODEL "B" | | | | | | 1) NOTE: PLEASE SUBMIT THE AIC RATING | | | FOR THE NEW SERVICE MAINS(S). | | | 110.9,215.5 | | | ALL SERVICE EQUIPMENT SHALL BE RATED FOR | | | THE AVAILABLE FAULT CURRENT. | | | | | | 2) NOTE: PLEASE SEE GENERAL NOTES, #5 | | | WHICH MENTIONS "ALL RECEPTICALES" IN | | | BEDRMS, THE WORDING PER 2002 NEC 210.12 | | | SHOULD READ ALL, "OUTLETS " IN BEDRMS. | | | IF THERE ARE ANY QUESTIONS, ON THIS | | | PLEASE CALL. | | | | | | 3) NOTE: PLEASE SEE WALL IN LIVING ROOM | | | WHICH SHOULD INDICATE THE RECEPT WITHIN | | | 6' OF DOOR OPENING. | | | PLEASE SEE REDLINED SET. | | | | | | ** PLEASE KNOW, THESE ARE FOR "MASTERS" | | | AND ALL MUST BE 100%. | | | | | | PLEASE CALL IF THERE ARE ANY QUESTIONS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2006-11-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-11-02 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-11-02 |
Time |
10:13 |
Sent To |
B |
|
| Notes |
| 2006-11-02 10:14:12 | TO "RMCDOUGAL" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2006-10-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-10-23 |
Time |
16:11 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-10-23 |
Time |
16:11 |
Sent To |
B |
|
| Notes |
| 2006-10-23 16:12:04 | TO "RMCDOUGAL" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-07-31 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-07-31 |
Time |
11:44 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-07-31 |
Time |
11:44 |
Sent To |
B |
|
| Notes |
| 2006-07-31 00:00:00 | TO "TGORDON" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-07-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-07-28 |
Time |
13:29 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-07-28 |
Time |
13:29 |
Sent To |
Z |
|
| Notes |
| 2006-07-28 00:00:00 | TO "MMCLEAN" DESK/RESUB--EXPEDITED | | | PERMIT |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-07-11 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-07-14 |
Time |
16:32 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-07-11 |
Time |
16:44 |
Sent To |
M |
|
| Notes |
| 2006-07-11 00:00:00 | TO "TGORDON" DESK/RESUB--EXPEDITED | | | PERMIT-- |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-07-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-07-08 |
Time |
17:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-07-08 |
Time |
17:50 |
Sent To |
Z |
|
| Notes |
| 2006-07-08 00:00:00 | TO "Z" BOX/RESUB--EXPEDITED PERMIT-- |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-04-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-27 |
Time |
10:21 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-27 |
Time |
10:20 |
Sent To |
E |
|
| Notes |
| 2006-04-27 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-05-10 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-04-26 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-04-19 |
Time |
08:44 |
Sent To |
|
|
| Notes |
| 2006-04-19 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2006-07-31 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-07-31 |
Time |
12:09 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2006-07-31 |
Time |
12:09 |
Sent To |
AD |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2006-07-12 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-07-12 |
Time |
09:25 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-07-12 |
Time |
09:25 |
Sent To |
P |
|
| Notes |
| 2006-07-12 00:00:00 | *** DENIED *** | | | 1) AS REQUESTED IN LAST REVIEW 4-28-06 | | | NOTE #6, PROVIDE RETURN AIR TO THE AHU, | | | BY A LOUVER DOOR, OR A RETURN AIR GRILL | | | IF A GRILL, SHOWING GRILL SIZE. | | | | | | 2) PLEASE NOTE SOME REVISIONS TO PLANS | | | ARE NOTED AS #9, BUT THE LAST REVISION | | | NOTED WAS #8 ON 03-15-06. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-04-28 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-04-28 |
Time |
10:25 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-04-28 |
Time |
10:25 |
Sent To |
P |
|
| Notes |
| 2006-04-28 00:00:00 | *** MODEL B *** | | | 1) DRYER VENT TERMINATION MUST BE A MIN. | | | OF 4 FEET FROM A/C CONDENSER UNIT. | | | | | | 2) SUPPLY AIR GRILLS NEED TO BE SIZED, | | | KITCHEN, AND EACH BATH ROOM. | | | | | | 3) RETURN AIR GRILLS NEED TO BE SIZED, | | | ALL. | | | | | | 4) SUPPLY AIR DUCT FROM AHU TO MIXING | | | BOX NEEDS TO SHOW THE SIZED. | | | | | | 5) NEED TO SHOW THE CFM'S AT ALL SUPPLY | | | AIR GRILLS. | | | | | | 6) PROVIDE RETURN AIR TO THE AHU, BY | | | LOUVER DOOR, OR RETURN AIR GRILL | | | (SHOWING SIZE). | | | | | | 7) PLEASE SHOW EQUIPMENT LISTING WITH | | | MAKE, MODEL NUMBER, TONS, SEER, TOTAL | | | COOLING BTU'S, TOTAL SENSIBLE BTU'S, AND | | | HEATER KW.. | | | | | | 8) PLEASE BE ADVISED 10 SEER IS | | | ACCEPTABLE AT THIS TIME, BUT MAY NOT BE | | | IN THE FUTURE. | | | | | | 9) PLEASE BE ADVISED 6" DUCT MAY BE TO | | | LARGE FOR THE BATH ROOMS. | | | | | | 10) PLEASE SEE NOTATIONS ON MECHANICAL | | | PLANS. | | | | | | 11) MANUAL J CALCULATIONS ARE MISSING, | | | PLEASE SUBMIT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2006-08-10 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-08-10 |
Time |
08:57 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-08-10 |
Time |
08:57 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2006-07-12 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-07-12 |
Time |
10:54 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-07-12 |
Time |
10:54 |
Sent To |
B |
|
| Notes |
| 2006-07-12 00:00:00 | DENIED; | | | 1.(SECOND REQUEST) DELETE THE PART OF | | | NOTE 8 ON PAGE P.201 REFURING TO AIR | | | CHAMBERS. AIR CHAMBERS ARE NOT AN | | | APPROVED ENGINEEREDPRODUCT AND DO NOT | | | WORK. | | | 2.(SECOND REQUEST) A TWO WAY CLEANOUT IS | | | REQUIRED IN THE DRAINAGE SYSTEM AT THE | | | JUNSION OF THE BUILING DRAIN AND THE | | | BUILDING SEWER PER FBC-2004 PLUMBING | | | SEC. 708.3.5. | | | 3.REVISION AREA OF TITLE BLOCK; THE LAST | | | REVISION ON SHEET IS 7 ON PLANS THERE IS | | | REFORENCE TO 8 PLEASE UP DATE PLANS. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-04-29 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-04-29 |
Time |
12:49 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-04-29 |
Time |
12:49 |
Sent To |
B |
|
| Notes |
| 2006-04-29 00:00:00 | DENIED; | | | 1.DELETE OR CHANGE NOTE # 8. WATER | | | HAMMER ARRESTORS ARE REQUIRED WHERE | | | QUICK CLOSING VALVES ARE USED, @ | | | AUTOMATIC CLOTHES WASHER, DISHWASHER, | | | AND ICE MAKER. SEE FBC-2004 PLUMBING | | | SEC. 604.9. | | | 2.AUTOMATIC CLOTHES WASHER BRANCH DRAIN | | | TO BE 3" SEC. 406.3. | | | 3. A TWO WAY CLEANOUT IS REQUIRED AT THE | | | JUNCTION OF THE BUILDING DRAIN AND THE | | | BUILDING SEWER. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2006-07-28 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-07-28 |
Time |
17:46 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-07-28 |
Time |
17:46 |
Sent To |
I |
|
| Notes |
| 2006-07-28 00:00:00 | APPROVED DRIVEWAY 10FT ONLY. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2006-07-14 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-07-11 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-07-11 |
Time |
14:14 |
Sent To |
I |
|
| Notes |
| 2006-07-14 00:00:00 | DENIED, | | | 1. THE PROPOSED DRIVEWAY & WALKWAY IS | | | OVER THE LANDSCAPE REQUIREMENT WITHIN | | | THE FRONT SETBACK OF PROPERTY. | | | 2. NEED TO REMOVE THE PROPOSED WALKWAY | | | TO MEET THE REQUIREMENT WITH THE 10FT | | | DRIVEWAY. | | | | | | | | | NOTE: MUST MAINTAIN 1000SQ FT OR 75% OF | | | LANDSCAPE, WHICHEVER IS LESS WITHIN THE | | | FIRST 25FT FRONT SETBACK. | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2006-04-26 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-04-26 |
Time |
14:04 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-04-26 |
Time |
14:04 |
Sent To |
I |
|
| Notes |
| 2006-04-26 00:00:00 | DENIED, | | | 1. MUST PROVIDE THE DIMENSION OF THE LOT | | | ON THE TWO COPYOF SITEPLAN. | | | 2. MUST PROVIDE THE DIMENSION OF | | | PROPOSED DRIVEWAY & WALKWAY (LENGTH & | | | WIDTH). | | | | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|