Plan Review Details - Permit 06040635
Plan Review Stops For Permit 06040635
Review Stop AD ADDRESSING
Rev No 1 Status N Date 2006-04-17 Cont ID  
Sent By ptjomsto Date 2006-04-17 Time 16:04 Rev Time 0.00
Received By ptjomsto Date 2006-04-17 Time 16:04 Sent To  
Notes
2006-04-17 00:00:00PROJECT REQUIRES ADDRESSING

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status P Date 2006-11-13 Cont ID  
Sent By rmcdouga Date 2006-11-13 Time 08:16 Rev Time 0.00
Received By rmcdouga Date 2006-11-13 Time 08:16 Sent To  
Notes
2006-11-13 08:21:44CHANGED TRUSS MANUFACTURER. REVISED TRUSS DRAWINGS ARE
 OK. CHANGE WAS MADE BEFORE ANY PERMITS WERE ISSUED
 UNDER THE MASTER.

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status F Date 2006-11-03 Cont ID  
Sent By rmcdouga Date 2006-11-03 Time 13:10 Rev Time 0.00
Received By rmcdouga Date 2006-11-03 Time 13:10 Sent To  
Notes
2006-11-03 13:30:18DENIED
  
 1) TRUSS DRAWINGS AND LAYOUT HAVE BEEN REVIEWED AND
 ACCEPTED BY HUSTAD ENGINEERING, HOWEVER, THE DESIGNER
 OF RECORD IS ROBERT H. BRAIDO JR. OF PEACOCK AND LEWIS.
 THERE IS NO INDICATION ON THE PLANS THAT HUSTAD
 ENGINEERING IS THE ENGONEER OF RECORD FOR THIS PROJECT.
 HAVE TRUSS DRAWINGS AND LAYOUTS REVIEWED AND ACCEPTED
 BY THE DESIGNER OF RECORD OR SUBMIT SIGNED AND SEALED
 LETTERS FROM THE ENGINEER AND FROM THE ARCHITECT
 CERTIFYING THAT HUSTAD ENGINEERING IS THE STRUCTURAL
 DESIGNER OF RECORD FOR THIS PROJECT.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2006-10-24 Cont ID  
Sent By rmcdouga Date 2006-10-24 Time 12:49 Rev Time 0.00
Received By rmcdouga Date 2006-10-24 Time 12:49 Sent To  
Notes
2006-10-24 14:11:03REVISION TO CHANGE TRUSSES IS DENIED
  
 1) TRUSS DRAWINGS AND LAYOUT ARE REQUIRED TO BE
 REVIEWED AND APPROVED BY THE DESIGNER OF RECORD FOR THE
 PROJECT.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2006-08-02 Cont ID  
Sent By rmcdouga Date 2006-08-02 Time 13:30 Rev Time 0.00
Received By rmcdouga Date 2006-08-02 Time 13:30 Sent To P
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-07-12 Cont ID  
Sent By rmcdouga Date 2006-07-12 Time 16:21 Rev Time 0.00
Received By rmcdouga Date 2006-07-12 Time 16:21 Sent To E
Notes
2006-07-12 00:00:00DENIED
  
 1) SHEET A1.0 DOES NOT HAVE A TITLE
 BLOCK. FAC 61G1-16.004 A TITLE BLOCK
 MUST APPEAR ON ALL ARCHITECTURAL OR
 INTERIOR DESIGN DRAWINGS AND
 SPECIFICATION IDENTIFICATION SHEETS.
  
 2) FBC TABLE 1607.1 REQUIRES TRUSSES TO
 HAVE A MINIMUM BOTTOM CORD LIVE LOAD OF
 10 PSF. A BC LIVE LOAD OF 0.0 PSF IS
 SPECIFIED ON THE TRUSS DRAWINGS. THE
 TRUSS COVERSHEET SPECIFIES 10 PSF.
  
 3) THE BOTTOM CORD DEAD LOAD IS
 SPECIFIED AS 5 PSF ON THE TRUSS
 COVERSHEET AND 15 PSF ON THE TRUSS
 DRAWINGS.
  
 4) THE TRUSS COVERSHEET REFERENCES THE
 2001 FBC. THE PROJECT IS UNDER THE 2004
 FBC.
  
 NOTE: IMPACT FEES AND NOC WILL BE
 REQUIRED FOR EACH PERMIT APPLIED FOR
 UNDER THE MASTER.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-05-10 Cont ID  
Sent By rmcdouga Date 2006-05-10 Time 14:41 Rev Time 0.00
Received By rmcdouga Date 2006-05-10 Time 14:41 Sent To  
Notes
2006-05-10 00:00:00DENIED BY BUILDING
  
 1) SUBMIT A TYPICAL DRAINAGE PLAN
 SHOWING COMPLIANCE WITH 2004 FBC R401.3.
 INDIVIDUAL DRAINAGE PLANS WILL BE
 REQUIRED FOR EACH PERMIT APPLIED FOR
 UNDER THE PROJECT.
  
 2) IMPACT FEES AND NOC WILL BE REQUIRED
 FOR EACH PERMIT UNDER PROJECT.
  
 3) THE WALL SECTION ON S2.01 SPECIFIES
 TWO COURSES OF BOND BEAM WITH ONE #7 IN
 EACH COURSE. THE BEAM SCHEDULE ON S2.02
 INDICATES ONE #5 IN EACH COURSE. PLEASE
 CORRECT.
  
 4) THE ENERGY CALCULATION FORM IS
 REQUIRED TO USE WORST-CASE CALCULATIONS
 FOR A MASTER PROJECT. SEE FBC
 13-600.2.A.5.
  
 5) THE TRUSS ENGINEER'S EMBOSSED STAMP
 IS REQUIRED TO HAVE THE WORDING CHANGED
 FROM "CERTIFICATE" TO "LICENSE".
  
 6) FBC TABLE 1607.1 REQUIRES TRUSSES TO
 HAVE A MINIMUM BOTTOM CORD LIVE LOAD OF
 10 PSF.
  
 7) THE DESIGN LOAD SCHEDULE ON S2.03,
 THE DESIGN LOADS ON THE TRUSS DRAWINGS
 AND THE DESIGN LOAD ON THE TRUSS LAYOUT
 DO NOT CONCUR. PLEASE CORRECT.
  
 8) THE UPLIFT FOR TRUSSES T2B, T3B AND
 T4B AT BEARING POINTS R1 AND R4 HAVE
 UPLIFTS ON THE ENDS THAT EXCEED THOSE
 LISTED ON S2.03.
  
 9) TRUSS T6 HAS AN UPLIFT OF 636# ON THE
 LEFT END WHICH EXCEEDS THE 510# LISTED
 ON S2.03.
  
 10) SUBMIT FLORIDA PRODUCT APPROVAL FOR
 THE "USP" THD210-2 HANGER.
  
 11) THE TABLE ON S3.01 SPECIFIES
 ALUMINUM SOFFITS AND THE SECTION ON
 S2.01 INDICATES STUCCO ON METAL LATH AT
 THE SOFFIT. PLEASE CORRECT.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-07-15 Cont ID  
Sent By dpalmer Date 2006-07-15 Time 10:21 Rev Time 0.00
Received By dpalmer Date 2006-07-15 Time 09:49 Sent To P
Notes
2006-07-15 00:00:00STAMPED ELECTRICAL PLANS, OK.
  
 ANY REVISONS TO THESE MUST BE DONE UNDER
 EACH PERMITTED SFR.
 MAY NOT REVISE THE MASTER.
 PLANS ROUTED TO PLUMB TO KEEP PLANS
 WITH THE OTHER MASTER MODEL AS NO OTHER
 REVIEWS WERE DONE ON OTHER MASTER MODEL.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-04-27 Cont ID  
Sent By dpalmer Date 2006-04-27 Time 15:26 Rev Time 0.00
Received By dpalmer Date 2006-04-27 Time 15:26 Sent To M
Notes
2006-04-27 00:00:00***** UNSAT *****
  
 MODEL "B"
  
 1) NOTE: PLEASE SUBMIT THE AIC RATING
 FOR THE NEW SERVICE MAINS(S).
 110.9,215.5
 ALL SERVICE EQUIPMENT SHALL BE RATED FOR
 THE AVAILABLE FAULT CURRENT.
  
 2) NOTE: PLEASE SEE GENERAL NOTES, #5
 WHICH MENTIONS "ALL RECEPTICALES" IN
 BEDRMS, THE WORDING PER 2002 NEC 210.12
 SHOULD READ ALL, "OUTLETS " IN BEDRMS.
 IF THERE ARE ANY QUESTIONS, ON THIS
 PLEASE CALL.
  
 3) NOTE: PLEASE SEE WALL IN LIVING ROOM
 WHICH SHOULD INDICATE THE RECEPT WITHIN
 6' OF DOOR OPENING.
 PLEASE SEE REDLINED SET.
  
 ** PLEASE KNOW, THESE ARE FOR "MASTERS"
 AND ALL MUST BE 100%.
  
 PLEASE CALL IF THERE ARE ANY QUESTIONS.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2006-11-02 Cont ID  
Sent By adarroug Date 2006-11-02 Time 10:16 Rev Time 0.00
Received By adarroug Date 2006-11-02 Time 10:13 Sent To B
Notes
2006-11-02 10:14:12TO "RMCDOUGAL" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2006-10-23 Cont ID  
Sent By adarroug Date 2006-10-23 Time 16:11 Rev Time 0.00
Received By adarroug Date 2006-10-23 Time 16:11 Sent To B
Notes
2006-10-23 16:12:04TO "RMCDOUGAL" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2006-07-31 Cont ID  
Sent By adarroug Date 2006-07-31 Time 11:44 Rev Time 0.00
Received By adarroug Date 2006-07-31 Time 11:44 Sent To B
Notes
2006-07-31 00:00:00TO "TGORDON" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-07-28 Cont ID  
Sent By adarroug Date 2006-07-28 Time 13:29 Rev Time 0.00
Received By adarroug Date 2006-07-28 Time 13:29 Sent To Z
Notes
2006-07-28 00:00:00TO "MMCLEAN" DESK/RESUB--EXPEDITED
 PERMIT

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-07-11 Cont ID  
Sent By mmclean Date 2006-07-14 Time 16:32 Rev Time 0.00
Received By adarroug Date 2006-07-11 Time 16:44 Sent To M
Notes
2006-07-11 00:00:00TO "TGORDON" DESK/RESUB--EXPEDITED
 PERMIT--

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-07-08 Cont ID  
Sent By adarroug Date 2006-07-08 Time 17:50 Rev Time 0.00
Received By adarroug Date 2006-07-08 Time 17:50 Sent To Z
Notes
2006-07-08 00:00:00TO "Z" BOX/RESUB--EXPEDITED PERMIT--

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-04-27 Cont ID  
Sent By adarroug Date 2006-04-27 Time 10:21 Rev Time 0.00
Received By adarroug Date 2006-04-27 Time 10:20 Sent To E
Notes
2006-04-27 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-05-10 Cont ID  
Sent By mmclean Date 2006-04-26 Time 14:14 Rev Time 0.00
Received By rmcdouga Date 2006-04-19 Time 08:44 Sent To  
Notes
2006-04-19 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2006-07-31 Cont ID  
Sent By tgordon Date 2006-07-31 Time 12:09 Rev Time 0.20
Received By tgordon Date 2006-07-31 Time 12:09 Sent To AD
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2006-07-12 Cont ID  
Sent By tgordon Date 2006-07-12 Time 09:25 Rev Time 0.30
Received By tgordon Date 2006-07-12 Time 09:25 Sent To P
Notes
2006-07-12 00:00:00*** DENIED ***
 1) AS REQUESTED IN LAST REVIEW 4-28-06
 NOTE #6, PROVIDE RETURN AIR TO THE AHU,
 BY A LOUVER DOOR, OR A RETURN AIR GRILL
 IF A GRILL, SHOWING GRILL SIZE.
  
 2) PLEASE NOTE SOME REVISIONS TO PLANS
 ARE NOTED AS #9, BUT THE LAST REVISION
 NOTED WAS #8 ON 03-15-06.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2006-04-28 Cont ID  
Sent By tgordon Date 2006-04-28 Time 10:25 Rev Time 0.30
Received By tgordon Date 2006-04-28 Time 10:25 Sent To P
Notes
2006-04-28 00:00:00*** MODEL B ***
 1) DRYER VENT TERMINATION MUST BE A MIN.
 OF 4 FEET FROM A/C CONDENSER UNIT.
  
 2) SUPPLY AIR GRILLS NEED TO BE SIZED,
 KITCHEN, AND EACH BATH ROOM.
  
 3) RETURN AIR GRILLS NEED TO BE SIZED,
 ALL.
  
 4) SUPPLY AIR DUCT FROM AHU TO MIXING
 BOX NEEDS TO SHOW THE SIZED.
  
 5) NEED TO SHOW THE CFM'S AT ALL SUPPLY
 AIR GRILLS.
  
 6) PROVIDE RETURN AIR TO THE AHU, BY
 LOUVER DOOR, OR RETURN AIR GRILL
 (SHOWING SIZE).
  
 7) PLEASE SHOW EQUIPMENT LISTING WITH
 MAKE, MODEL NUMBER, TONS, SEER, TOTAL
 COOLING BTU'S, TOTAL SENSIBLE BTU'S, AND
 HEATER KW..
  
 8) PLEASE BE ADVISED 10 SEER IS
 ACCEPTABLE AT THIS TIME, BUT MAY NOT BE
 IN THE FUTURE.
  
 9) PLEASE BE ADVISED 6" DUCT MAY BE TO
 LARGE FOR THE BATH ROOMS.
  
 10) PLEASE SEE NOTATIONS ON MECHANICAL
 PLANS.
  
 11) MANUAL J CALCULATIONS ARE MISSING,
 PLEASE SUBMIT.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop P PLUMBING
Rev No 3 Status P Date 2006-08-10 Cont ID  
Sent By jleech Date 2006-08-10 Time 08:57 Rev Time 0.00
Received By jleech Date 2006-08-10 Time 08:57 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2006-07-12 Cont ID  
Sent By jleech Date 2006-07-12 Time 10:54 Rev Time 0.00
Received By jleech Date 2006-07-12 Time 10:54 Sent To B
Notes
2006-07-12 00:00:00DENIED;
 1.(SECOND REQUEST) DELETE THE PART OF
 NOTE 8 ON PAGE P.201 REFURING TO AIR
 CHAMBERS. AIR CHAMBERS ARE NOT AN
 APPROVED ENGINEEREDPRODUCT AND DO NOT
 WORK.
 2.(SECOND REQUEST) A TWO WAY CLEANOUT IS
 REQUIRED IN THE DRAINAGE SYSTEM AT THE
 JUNSION OF THE BUILING DRAIN AND THE
 BUILDING SEWER PER FBC-2004 PLUMBING
 SEC. 708.3.5.
 3.REVISION AREA OF TITLE BLOCK; THE LAST
 REVISION ON SHEET IS 7 ON PLANS THERE IS
 REFORENCE TO 8 PLEASE UP DATE PLANS.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop P PLUMBING
Rev No 1 Status F Date 2006-04-29 Cont ID  
Sent By jleech Date 2006-04-29 Time 12:49 Rev Time 0.00
Received By jleech Date 2006-04-29 Time 12:49 Sent To B
Notes
2006-04-29 00:00:00DENIED;
 1.DELETE OR CHANGE NOTE # 8. WATER
 HAMMER ARRESTORS ARE REQUIRED WHERE
 QUICK CLOSING VALVES ARE USED, @
 AUTOMATIC CLOTHES WASHER, DISHWASHER,
 AND ICE MAKER. SEE FBC-2004 PLUMBING
 SEC. 604.9.
 2.AUTOMATIC CLOTHES WASHER BRANCH DRAIN
 TO BE 3" SEC. 406.3.
 3. A TWO WAY CLEANOUT IS REQUIRED AT THE
 JUNCTION OF THE BUILDING DRAIN AND THE
 BUILDING SEWER.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop Z ZONING
Rev No 3 Status P Date 2006-07-28 Cont ID  
Sent By mmclean Date 2006-07-28 Time 17:46 Rev Time 0.00
Received By mmclean Date 2006-07-28 Time 17:46 Sent To I
Notes
2006-07-28 00:00:00APPROVED DRIVEWAY 10FT ONLY.

Review Stop Z ZONING
Rev No 2 Status F Date 2006-07-14 Cont ID  
Sent By mmclean Date 2006-07-11 Time 14:14 Rev Time 0.00
Received By mmclean Date 2006-07-11 Time 14:14 Sent To I
Notes
2006-07-14 00:00:00DENIED,
 1. THE PROPOSED DRIVEWAY & WALKWAY IS
 OVER THE LANDSCAPE REQUIREMENT WITHIN
 THE FRONT SETBACK OF PROPERTY.
 2. NEED TO REMOVE THE PROPOSED WALKWAY
 TO MEET THE REQUIREMENT WITH THE 10FT
 DRIVEWAY.
  
  
 NOTE: MUST MAINTAIN 1000SQ FT OR 75% OF
 LANDSCAPE, WHICHEVER IS LESS WITHIN THE
 FIRST 25FT FRONT SETBACK.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720
  

Review Stop Z ZONING
Rev No 1 Status F Date 2006-04-26 Cont ID  
Sent By mmclean Date 2006-04-26 Time 14:04 Rev Time 0.00
Received By mmclean Date 2006-04-26 Time 14:04 Sent To I
Notes
2006-04-26 00:00:00DENIED,
 1. MUST PROVIDE THE DIMENSION OF THE LOT
 ON THE TWO COPYOF SITEPLAN.
 2. MUST PROVIDE THE DIMENSION OF
 PROPOSED DRIVEWAY & WALKWAY (LENGTH &
 WIDTH).
  
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720