| Plan Review Stops For Permit 06040623 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2007-04-06 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2007-04-06 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2007-04-06 |
Time |
10:52 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2007-02-09 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2007-02-09 |
Time |
17:22 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2007-02-09 |
Time |
17:22 |
Sent To |
|
|
| Notes |
| 2007-02-09 17:23:02 | ROOF ENGINEERING APPROVED |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2006-09-15 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-02-05 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2006-09-15 |
Time |
08:01 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-07-26 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2006-07-26 |
Time |
09:13 |
Rev Time |
2.00 |
| Received By |
amorse |
Date |
2006-07-26 |
Time |
09:13 |
Sent To |
PC |
|
| Notes |
| 2006-07-26 00:00:00 | | | | | | | DENIED | | | | | | THE FOLLOWING NOTES WERE NOT ADDRESSED | | | ON THE FIRST REVIEW | | | | | | 5) PROVIDE SIGNED AND DATED ENERGY | | | CALC'S BE SURE THEY ARE SIGNED AND DATED | | | BY PREPARER AND OWNER/AGENT | | | ***(OWNER/AGENT HAS NOT SIGNED)*** | | | | | | 15) PROVIDE WOOD CONNECTORS THAT TIE | | | TRUSSES TO GIRDERS AT VARIOUS LOCATIONS | | | AND STRAPS TO BE USED AT VALLEY SETS | | | ***(TRUSS DRAWINGS TO BE REVIEWED AND | | | APPROVED BY DESIGNER OF RECORD PLEASE | | | NOTE THAT THE DRAWINGS FOR TRUSS TO | | | TRUSS AND VALLEY ATTACHMENT IS BY | | | OTHERS)PLEASE PROVIDE ATTACHMENT THAT | | | MEETS REQUIRED UPLIFTS*** | | | | | | 1) ONLY ONE COPY OF SOIL REPORT WAS | | | SUBMITTED | | | | | | 2) SEE ZONING COMMENTS SITE PLAN TO | | | MATCH SETBACKS ON SURVEY | | | | | | 3) PRODUCT APPROVAL FOR HORIZNTAL | | | SLIDERS HAVE A MAXIMUM WIDTH OF 74" | | | WINDOW TYPE #5 ON SCHEDULE IS 106 1/4" | | | WIDE. | | | | | | 4) PLEASE STATE TYPE OF GLASS ON THE | | | HORIZONTAL SLIDER AS THE MIN GLASS TYPE | | | DOES NO MEET THE REQUIRED PRESSURE ON | | | THE SCHEDULE (SEE PAGE 1 OF 6 IN PRODUCT | | | APPROVAL DRAWING) | | | | | | 5) WINDOW PRESSURES FROM PRODUCT | | | APPROVALS DO NOT MATCH SCHEDULE ON 5/12 | | | PLEASE MATCH OR DELETE THIS INFORMATION | | | | | | 6) WINDOW SIZE SKETCH FOR SH25 (WINDOW | | | #4 ON SCEDULE) SHOWS A SH24 PLEASE | | | CLARIFY | | | | | | 7) NO PRODUCT APPROVALS WERE SUBMITTED | | | FOR REGULAR PANEL DOORS (#8 & #9 ON | | | SCHEDULE) | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-05-23 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-05-23 |
Time |
10:28 |
Rev Time |
3.00 |
| Received By |
amorse |
Date |
2006-05-23 |
Time |
10:28 |
Sent To |
PC |
|
| Notes |
| 2006-05-23 00:00:00 | | | | | | | DENIED | | | | | | 1) BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SETS OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561) 233-5025 FOR MORE | | | INFORMATION. | | | | | | 2) THE STATE OF FLORIDA REQUIRES | | | COLLECTION OF A RADON SURCHARGE ON ALL | | | NEW CONSTRUCTION COMPUTED ON UNDER ROOF | | | FLOOR SPACE PER 10D-91 FAC. PERMIT FEES | | | WILL BE INCREASED ACCORDINLY | | | | | | 3) A DESIGN PROFESSIONAL THAT IS | | | REGISTERED TO PRACTICE UNDER CHAPTER 481 | | | OR 471 OF THE FLORIDA STATUTES SHALL | | | AFFIX THEIR OFFICIAL SEAL, SIGNATURE AND | | | DATE TO SAID DRAWINGS AND SPECIFICATIONS | | | PER 106.1 FBC 2004. THE DATE IS MISSING | | | ALSO THERE IS A MISTAKE ON THE LICENCE# | | | | | | 4) PROVIDE UNDER ROOF SQ FT OF ADDITION, | | | CARPORT AND FRONT PORCH. THESE ARE | | | REQUIRED FOR COUNTY IMPACT FEES AND | | | STATE RADON FEE | | | | | | 5) PROVIDE SIGNED AND DATED ENERGY | | | CALC'S BE SURE THEY ARE SIGNED AND DATED | | | BY PREPARER AND OWNER/AGENT | | | | | | 6) THE PERMIT APPLICATION SHALL INCLUDE | | | TWO COPIES OF EACH PRODUCT APPROVAL THAT | | | IS RELEVANT PER 9B-72. THESE SHOULD | | | INCLUDE THE FLORIDA STATE APPROVAL COVER | | | PAGES, AND THE PRODUCT NOA THAT LISTS | | | THE SYSTEM COMPONENTS/ FASTENER LIST | | | PAGES, THE PAGES WITH THE CHOSEN | | | ASSEMBLY/ SYSTEM TO BE USED AND THE | | | GENERAL LIMITATIONS PAGE. ALL CAN BE | | | FOUND ON WWW.FLORIDABUILDING.ORG | | | | | | 7) PROVIDE COPY OF SURVEY THAT IS LESS | | | THAN 1 YR OLD | | | | | | 8) PROVIDE PRODUCT APPROVAL FOR WOOD | | | CONNECTORS/HURRICANE STRAPS (SEE | | | ATTACHED SHEETS, THIS METHOD WHERE THE | | | FL# AND THE CONNECTORS USED ARE MARKED | | | IS ADEQUATE) | | | | | | 9) PRODUCT APPROVALS DO NOT MATCH | | | DRAWINGS, NOSH WINDOW APPROVALS BUT ALL | | | OPENING WINDOWS ON DRAWING SPECIFY SH. | | | APPROVALS FOR CASEMENT AND HORIZONTAL | | | SLIDERS BUT NONE SPECIFIED ON DRAWINGS. | | | FIXED WINDOW APPROVALS ARE NON-IMPACT AS | | | SUCH WILL REQUIRE OPENING PROTECTIVES, | | | SUBMIT PRODUCT APPROVALS. ALL PRODUCT | | | APPROVAL DRAWINGS ARE MISSING DATA AS | | | PRINTING SEEMED TO CUT OF TOP OF DRWGS | | | | | | 10) IF THESE PRODUCTS ARE TO BE USED | | | UPDATE WINDOW SCHEDULE AND DRAWINGS TO | | | REFLECT CHANGES | | | | | | 11) CORRECT BLDG DESIGN DATA ON PAGE 1 | | | | | | 12) FOUNDATION SHALL BE A MINIMUM OF 12" | | | BELOW GRADE PER R403.1.4 FBC (SEE DETAIL | | | 1/8 ON PG.8 | | | | | | 13) PROVIDE DETAILS ON PORCH BEAM AND | | | RAFTER ATTACHMENT TO BEAM AND TIE IN TO | | | EXISTING ROOF. | | | | | | 14) PROVIDE DETAILS ON CARPORT BEAMS | | | | | | 15) PROVIDE WOOD CONNECTORS THAT TIE | | | TRUSSES TO GIRDERS AT VARIOUS LOCATIONS | | | AND STRAPS TO BE USED AT VALLEY SETS | | | | | | 16) PERMIT APPLICATION STATES | | | REPLACEMENT OF WINDOWS AND ROOF IN | | | EXISTING STRUCTURE, PLEASE CLARIFY, IF | | | SHINGLE ARE TO BE RELACED ON ENTIRE ROOF | | | SPECIFY ON DRAWING. LIKEWISE FOR WINDOWS | | | AS ONLY A FEW ARE TO BE REMOVED AS PER | | | DEMO PLAN | | | | | | 17) A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT IS REQUIRED PRIOR TO | | | A PERMIT BEING ISSUED | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2007-06-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-06-07 |
Time |
11:53 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-06-07 |
Time |
10:43 |
Sent To |
PC |
|
| Notes |
| 2007-06-07 11:54:32 | CORRECTED NOTES FOR SMOKE ALARMS/ DETECTORS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2007-05-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-05-16 |
Time |
10:25 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-05-15 |
Time |
16:51 |
Sent To |
PC |
|
| Notes |
| 2007-05-16 10:25:42 | ** UNSAT** | | | | | | ** PLEASE SEE REFERENCES TO CHAPTER 1 OF THE FLORIDA | | | BUILDING CODE IS THE ADMINISTRATIVE SECTION AS ADOPTED | | | BY THE CITY OF WEST PALM BEACH. | | | | | | | | | 1) NOTE: PLEASE SEE PLANS ARE NOT INDICATING ANY | | | REVISIONS BY CLOUDS/TRIANGLES OR DATES IN TITLE BLOCK. | | | FBC 106.1.2 | | | | | | 2) NOTE: PLEASE SEE THE PLANS ARE NOT DATED BY THE | | | DESIGNER OF RECORD AS REQUIRED UNDER PER FS 481.221. | | | | | | 3) NOTE: PLEASE SEE THE RISER DIAGRAM IS NOW REVISED | | | SHOWING NO MAIN, YET PLANS STILL INDICATE A MAIN | | | DISCONNECT OUTSIDE? | | | PLEASE CLARIFY AND KNOW THAT NO MORE THAN 8FT OF | | | UNPROTECTED CONDUCTORS ARE PERMITTED INSIDE BUILDING. | | | 230.70. | | | | | | 4) NOTE: PLEASE SEE 250.6, 250.24 AS EQUIPMENT | | | GROUNDING CONDUCTORS ARE BEING BEFORE THE FIRST MEANS | | | OF DISCONNECT AS THE RISER DOES NOT INDICATE ANY MAIN | | | BEFORE THE PANEL? | | | * EQUIPMENT GROUNDS ARE ONLY INSTALLED AFTER THE FIRST | | | MEANS OF DISCONNECT* | | | | | | 5) NOTE: PLEASE SEE THE PLANS HAVE BEEN REVISED | | | REMOVING THE PREVIOUS BATHS 2 AND 3, HOWEVER THE NEW | | | PLANS INDICATE ONLY ONE BATH AND RECEPTACLE AS | | | EXISTING. HOW IS THIS RECEPTACLE EXISTING WHEN THE | | | WALLS/LAYOUT/ AND BATH IS NEW. PLEASE SEE PREVIOUS | | | PLANS WHICH DID NOT INDICATE THIS. | | | PLEASE COORDINATE AND CLARIFY THIS. | | | FBC 106.1.2 | | | | | | 6) NOTE: PLEASE SEE NFPA-72 DEFINITIONS FOR SMOKE | | | DETECTION DEVICES. IF THESE ARE 120V DEVICES WHICH | | | DETECT AND SOUND AN ALARM, THEY ARE SMOKE ALARMS AND | | | SHOULD BE SHOWN AS SA. IF THESE ARE INDEED SMOKE | | | DETECTORS WHICH ARE SHOWN AS SD, THEN THESE ONLY DETECT | | | AND PLANS NEED TO SHOW SOUNDING DEVICES AND PANEL FOR | | | CONTROL. | | | | | | 7) NOTE: PLEASE SEE PREVIOUS ISSUED PLANS REDLINED THE | | | REQUIRED CODE FOR PLANS. | | | PLEASE BE SURE THE FOLLOWING CODES ARE LISTED ON | | | ELECTRICAL PLANS. | | | 2004 FBC, 2002 NFPA-70 (NEC) AND THE 2002 NFPA-72. | | | | | | *** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-08-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-08-24 |
Time |
16:24 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-08-24 |
Time |
16:08 |
Sent To |
M |
|
| Notes |
| 2006-08-24 00:00:00 | ***** REDLINED PLANS. | | | | | | | | | 1)PLEASE SEE MINIMUM CONDUIT SIZE SHALL | | | BE 2" FOR THE SEC'S AND THE FEEDERS FROM | | | MAIN DISCONNECT TO SUB PANEL. | | | PLEASE SEE CHAPTER 9,TABLES. | | | | | | 2) PLEASE SEE REDLINED NFPA-72 2002, | | | NFPA-70 2002 ON ELECTRICAL PLANS. | | | | | | 3) PLEASE SEE REDLINED MIN CLEARENCES | | | FOR THE AHU DISCONNECT AS SHOWN. | | | 110.26 | | | | | | | | | ** PLEASE REVISE NOTE #1 WHEN REVISING | | | PLANS BEFORE ROUGH ALONG WITH ANY OTHER | | | REVISIONS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-07-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-07-23 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-07-23 |
Time |
15:25 |
Sent To |
M |
|
| Notes |
| 2006-07-23 00:00:00 | ******** UNSAT 2ND REVIEW ********* | | | | | | ** IMPORTANT ** | | | ONCE ALL REVIEWS ARE COMPLETE PLANS WILL | | | BE PICKED UP FOR CORRECTIONS. | | | BEFORE RESUBMITTING PLANS, PLEASE | | | COMPLETELY "REMOVE" ALL OLD/VOIDED | | | SHEETS FROM SETS AND ONLY "INSERT NEW" | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STMAPING. ONLY ONE COPY OF THE | | | OLD/VOIDED REMOVED SHEETS SHOULD BE | | | SUBMITTED FOR REFERENCE SEPARATELY. | | | THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | ************************************* | | | | | | 1) NOTE: PLEASE CORRELATE RISER AND | | | PANEL, PLEASE SEE ONE SHOWS 200A AND THE | | | OTHER 150A. | | | 106.1.2 FBC | | | | | | 2) NOTE: PLEASE SEE LOCATIONS FOR | | | FAN/LTS IN BEDRMS AND LIVING RMS ARE | | | BEING SHOWN AS A "J" BOX ONLY. PLEASE | | | CLARIFY AS FIXTURES OF SOME SORT IS | | | REQUIRED FOR EGRESS LTS. | | | 210.70 LS 101 7.8 | | | | | | 3) NOTE: PLEASE SEE COVER SHEET SHOWS | | | 2000 LS 101, PLEASE KNOW, AS OF JAN 05, | | | THE STATE ADOPTED THE 2003 LS 101. | | | PLEASE ALSO PLACE THE FOLLOWIGN CODES ON | | | THE ELECTRICAL PLANS AS REQUIRED. | | | 2002 NFPA-70, 2002 NFPA-72 | | | | | | 4) NOTE: PLEASE INDICATE THE REQUIRED | | | LICENSE INFORMATION FOR MARK ROBINSON | | | DESIGN , LLC. | | | PLEASE SEE FS 481.219, FS 471.023 FOR | | | MISSING CERTIFICATE OF AUTHORIZATION #. | | | WHAT TYOE OF BUSINESS IS THIS? IF | | | ARCHITECT WORKS FOR THIS DESIGN FIRM, | | | PLEASE INCLUDECA #. | | | 61G1-16.004 | | | | | | 5) NOTE: PLEASE SEE MAX OCP FOR AHU IS | | | TYPICALL 150% , HOWEVER PANEL SCHEDULE | | | SHOWS 60A OCP FOR 5KW HEAT IN AHU? | | | PLEASE SEE 424.3B FOR MIN @125%. | | | PLEASE ALSO SEE #6, SHOWN WHICH IS OK, | | | HOWEVER IF SHOWN ON PLANS, #6 WILL BE | | | REQUIRED. PLEASE ALSO KNOW, IF THE 5KW | | | UNTI CONTAINS THE TYPICAL 30A OCP, #6 | | | WILL NOT INSERT INTO A 30A BRKR. | | | PLEASE ADJUST. | | | 106.1.2 | | | | | | 6) NOTE: PLEASE SEE 250.50, AS THE NEW | | | "FOOTER STEEL" SHALL BE PART OF THE | | | GROUNDING ELECTRODE SYSTEM. | | | PLEASE ALSO CLARIFY THE "STRUCTURAL | | | STEEL" AS NOTED.?? | | | | | | 7) NOTE: PLEASE SEE 110.26 FOR MIN | | | CLEARENCES FOR THE CU/ AHU DISC'S. | | | | | | 8) NOTE: PLEASE SEE MISSING GFI RECEPTS | | | FOR CU'S. (BOTH) | | | 210.63, 210.8A3 | | | | | | 9) NOTE: PLEASE VERIFY CIRCUITING OF LT | | | OUTSIDE BATH #3, AS LTS IN THE SAME SW | | | BOX ARE ON 19, HOWEVER LT FOR THE LT | | | ADJACENT IS ON THE MASTER BEDRM/EXT | | | RECEPT CIRCUIT. THIS IS OK, HOWEVER IF | | | SHOWN, THIS IS REQUIRED. THIS IS ONLY | | | NOTED FOR INFORMATIONAL PURPOSE AND THIS | | | DOES NOT REQUIRE CHANGE. | | | THIS CAN BE REVISED AT A LATER DATE, AS | | | OTHER REVISIONS WILL MOST LIKELY TAKE | | | PLACE. | | | | | | 10) NOTE: PLEASE SEE SOME ELECTRICAL | | | DEVICES ON PLANS ARE MISSING CIRCUITING. | | | 408.4. | | | | | | 11) NOTE: PLEASE LIST ALL THE REQUIRED | | | ARC FAULT PROTECTED CIRCUITS ON PANEL | | | SCHEDULE. PLEASE SEE ARC FAULT IS ONLY | | | SHWON FOR THE SD/LTS CIRCUIT AND ARC | | | FUALT IS ONLY NOTED ON PLANS FOR RECEPTS | | | NOT ALL AS REQUIRED PER 2002 NEC 210.12B | | | PLEASE LIST ON SCHEDULE. 408.4. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-05-05 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-05-05 |
Time |
13:10 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-05-05 |
Time |
12:27 |
Sent To |
P |
|
| Notes |
| 2006-05-05 00:00:00 | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} THE 1/0 SERVICE CONDUCTORS SHOWN ON | | | THE RISER DIAGRAM ARE NOT LARGE ENOUGH | | | FOR A 200 AMP SERVICE. SEE 310.15(B)(6). | | | | | | 2} PLEASE LOCATE THE 200 AMP MAIN | | | DISCONNECT ON THE PLAN . | | | | | | 3} PLEASE SEE THAT SMOKE DETECTORS MUST | | | BE ON AN ARC FAULT CIRCUIT PER 210.12. | | | | | | 4} A RECEPTACLE MUST BE ADDED TO THE | | | REAR OF THE HOUSE PER 21.52(E). | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2007-10-19 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-11-05 |
Time |
08:18 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-10-19 |
Time |
16:54 |
Sent To |
G |
|
| Notes |
| 2007-10-19 16:54:50 | TO "G" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2007-09-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-09-12 |
Time |
13:01 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-09-12 |
Time |
13:01 |
Sent To |
P |
|
| Notes |
| 2007-09-12 13:02:02 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2007-06-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-05 |
Time |
13:28 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-05 |
Time |
13:28 |
Sent To |
E |
|
| Notes |
| 2007-06-05 13:29:17 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2007-05-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-05-14 |
Time |
10:07 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-14 |
Time |
10:07 |
Sent To |
E |
|
| Notes |
| 2007-05-14 10:07:22 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2007-01-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-01-10 |
Time |
16:10 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-01-10 |
Time |
16:10 |
Sent To |
P |
|
| Notes |
| 2007-01-10 16:11:00 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2006-12-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-12-20 |
Time |
16:12 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-20 |
Time |
16:12 |
Sent To |
P |
|
| Notes |
| 2006-12-20 16:13:06 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-08-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-22 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-22 |
Time |
15:05 |
Sent To |
E |
|
| Notes |
| 2006-08-22 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-08-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-18 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-18 |
Time |
11:49 |
Sent To |
|
|
| Notes |
| 2006-08-18 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-07-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-07-19 |
Time |
13:52 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-07-19 |
Time |
13:52 |
Sent To |
E |
|
| Notes |
| 2006-07-19 00:00:00 | TO "E" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-07-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-07-13 |
Time |
11:36 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-07-13 |
Time |
11:36 |
Sent To |
Z |
|
| Notes |
| 2006-07-13 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-05-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-04 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-04 |
Time |
10:43 |
Sent To |
E |
|
| Notes |
| 2006-05-04 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2006-05-23 |
Time |
|
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-18 |
Time |
09:01 |
Sent To |
|
|
| Notes |
| 2006-04-18 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2006-08-25 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-08-25 |
Time |
08:27 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2006-08-25 |
Time |
14:51 |
Sent To |
P |
|
| Notes |
| 2006-08-24 00:00:00 | NEW SHEETS |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2006-07-24 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-07-24 |
Time |
11:28 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-07-24 |
Time |
11:28 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-05-08 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-05-08 |
Time |
07:12 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-05-08 |
Time |
08:23 |
Sent To |
B |
|
| Notes |
| 2006-05-08 00:00:00 | *** DENIED *** | | | 1) ARCHITECT PRINTED NAME, LICENSE | | | NUMBER, ADDRESS, AND PHONE NUMBER, PER | | | TITLE BLOCK,FAC 61G1-16.004. | | | | | | 2) PLEASE SUBMIT ENERGY CALCULATIONS | | | FORM 600A-04 (2004) PER FBC 13-600.3.A . | | | | | | 3) PLEASE SUBMIT A MANUAL J CALCULATION, | | | PER 2004 FBC 13-607.1.ABC.1 . | | | | | | 4) DRYER VENT EXHAUST MUST TERMINATE A | | | MIN. OF FOUR FEET FROM THE A/C CONDENSER | | | UNIT, PER 2004 FBC/M 401.5.2 . | | | | | | 5) ELECTRICAL PLANS ARE CALLING FOR A 10 | | | KW HEATER, AND MECHANICAL PLANS ARE | | | CALLING FOR A 5 KW HEATER, PLEASE | | | CORRECT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
7 |
Status |
F |
Date |
2007-11-05 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-11-05 |
Time |
08:19 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-11-05 |
Time |
08:03 |
Sent To |
|
|
| Notes |
| 2007-11-05 08:18:46 | DENIED; | | | 1. STILL NO GAS PERMIT. | | | 2. POOL PERMIT SPECS OUT A GAS POOL HEATER. NOT SHOWN | | | ON GAS PLAN. | | | 3. WITH A 2# GAS SYSTEM A SHUTOFF VALVE A REGULATOR AND | | | A UNION ARE REQUIRED. SEE ONE PLAN MARKED IN RED. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
6 |
Status |
F |
Date |
2007-10-01 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-10-01 |
Time |
07:52 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-10-01 |
Time |
07:52 |
Sent To |
|
|
| Notes |
| 2007-10-01 08:33:11 | DENIED; | | | 1.SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE BEING USED. | | | 2. TYPE OF GAS, (LP OR NATURAL) | | | 3. INDICATE THE DELIVERY PRESSURE (PSI) | | | PER FBC-2004 FUEL GAS CODE SEC. 402.2. | | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. | | | 4. GAS APPIANCE NOT LISTED ON PLANS. | | | 5. SEPARATE GAS PERMIT REQUIRED. ( NO PERMIT ON FILE ) | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2007-02-05 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-02-05 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-02-05 |
Time |
10:47 |
Sent To |
B |
|
| Notes |
| 2007-02-05 10:48:10 | REVISED FLOOR PLAN AND PLUMBING PIPE LAYOUT. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2007-01-20 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-01-20 |
Time |
12:47 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-01-20 |
Time |
12:47 |
Sent To |
B |
|
| Notes |
| 2007-01-20 12:49:06 | CHANGED SANITARY UNDER GROUND AS-BUILT |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2006-09-13 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-08-25 |
Time |
14:52 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-09-13 |
Time |
07:53 |
Sent To |
B |
|
| Notes |
| 2006-08-24 00:00:00 | NEW SHEETS |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2006-07-24 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-07-24 |
Time |
13:44 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-07-24 |
Time |
13:44 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2006-05-08 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-05-08 |
Time |
07:12 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-05-08 |
Time |
07:12 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2006-08-21 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-08-21 |
Time |
18:02 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-08-21 |
Time |
18:02 |
Sent To |
I |
|
| Notes |
| 2006-08-21 00:00:00 | NOTE: THE PROPOSED A/C PAD ON THE SOUTH | | | EAST SIDE SHALL NOT BE CLOSER THAN 1FT | | | FROM SIDE PROPERTY LINE. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2006-07-18 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-07-18 |
Time |
15:46 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-07-18 |
Time |
15:46 |
Sent To |
I |
|
| Notes |
| 2006-07-18 00:00:00 | DENIED, | | | 1. THE MINIMUM FRONT SETBACK FOR | | | STRUCTURE IS 25FT, SITEPLAN SHOWS | | | 24.9FT.(SURVEY SHOWS THE EXISTING | | | CARPORT AT 30.03FT) | | | 2. THE CARPORT MUST SIT BACK 25FT. | | | PLEASE PROVIDE TWO COPY OF CORRECTED | | | SITEPLAN. | | | | | | | | | NOTE:THE PROPOSED A/C PAD ( ON EAST | | | SIDE) SHALL NOT BE CLOSER THAN 1FT FROM | | | SIDE PROPERTY LINE. | | | | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2007-11-05 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-05-03 |
Time |
15:49 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-05-03 |
Time |
15:49 |
Sent To |
I |
|
| Notes |
| 2006-05-03 00:00:00 | DENIED, | | | 1. PLEASE CLARIFY COMMENT ON DEMOLITION | | | PLAN(3 OF 12) "REMOVE EXISTING | | | CONCRETE CARPORT IN ORDER TO PREPARE FOR | | | ADDITION CONSTRUCTION". | | | 2. PLEASE SUBMIT 1 COPY OF CURRENT | | | SURVEY. | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|