| Plan Review Stops For Permit 06040588 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2006-05-09 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-05-09 |
Time |
10:41 |
Rev Time |
0.33 |
| Received By |
alange |
Date |
2006-05-09 |
Time |
10:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2006-06-01 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-06-01 |
Time |
14:30 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-06-01 |
Time |
13:54 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-05-04 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-05-04 |
Time |
16:55 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-05-04 |
Time |
16:03 |
Sent To |
M |
|
| Notes |
| 2006-05-04 00:00:00 | | | | | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} INDICATE WHETHER NG OR LP. | | | | | | 2} SUBMIT A RISER DIAGRAM INDICATIG THE | | | ELECTRICAL LOCATION OF BOTH THE | | | GENERATOR AND SERVICE EQUIPMENT. SEE | | | 230.72 FOR GROUPING OF DISCONNECTS, | | | 225.31-39 FOR LOCATION AND RATINGS, | | | 250.32 AND 250.66 FOR GROUNDING. | | | | | | 3} SUBMIT A PANEL SCHEDULE AND A LOAD | | | CALCULATION FOR THE LOAD SERVED BY THE | | | GENERATOR. SEE 702.5. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2006-05-05 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-05-05 |
Time |
13:11 |
Rev Time |
0.15 |
| Received By |
mperson |
Date |
2006-05-05 |
Time |
13:11 |
Sent To |
B |
|
| Notes |
| 2006-05-05 00:00:00 | NOTE: GAS PERMIT REQUIRED. GAS CONTRAC- | | | TOR TO SUBMIT PLANS WITH PERMIT APPLICA- | | | TION. ALL GAS INSPECTIONS TO BE COMPLETE | | | BEFORE FINAL GEN/RES INSPECTION. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-05-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-30 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-30 |
Time |
11:30 |
Sent To |
E |
|
| Notes |
| 2006-05-30 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-05-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-17 |
Time |
11:46 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-17 |
Time |
11:46 |
Sent To |
Z |
|
| Notes |
| 2006-05-17 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-04-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-26 |
Time |
08:58 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-26 |
Time |
08:58 |
Sent To |
E |
|
| Notes |
| 2006-04-26 00:00:00 | TO "GEN-RES" "E" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-05-09 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-04-25 |
Time |
15:11 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-04-17 |
Time |
11:08 |
Sent To |
|
|
| Notes |
| 2006-04-17 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2006-06-01 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-06-01 |
Time |
15:57 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2006-06-01 |
Time |
16:09 |
Sent To |
|
|
| Notes |
| 2006-06-01 00:00:00 | *** PROVISO *** | | | 1)1)PER 2004 FBC, FUEL GAS - POWERED | | | EQUIPMENT - PERMANENTLY INSTALLED | | | EQUIPMENT POWERED BY INTERNAL COMBUSTION | | | ENGINES SHALL BE INSTALLED IN ACCORDANCE | | | WITH MANUFACTURE'S INSTALLATION | | | INSTRUCTIONS AND NFPA 37. | | | | | | NFPA 37 INSTALLATION & USE OF STATIONARY | | | COMBUSTION ENGINES & GAS TURBINES: | | | 4.1.4ENGINES (GENERATORS) LOCATED | | | OUTDOORS SHALL BE MINIMUM OF 5 FT FROM | | | OPENINGS IN WALLS & AT LEAST 5 FT FROM | | | STRUCTURES HAVING COMBUSTIBLE WALLS.A | | | MINIMUM CLEARANCE IS NOT REQUIRED WHEN | | | (1) THE ADJACENT WALL HAS A MINIMUM FIRE | | | RESISTANCE RATING OF 1 HOUR OR (2) THE | | | WEATHERPROOF ENCLOSURE IS CONSTRUCTED OF | | | NON-COMBUSTIBLE MATERIALS, AND IT HAS | | | BEEN DEMONSTRATED THAT A FIRE WITHIN THE | | | ENCLOSURE WILL NOT IGNITE COMBUSTIBLE | | | MATERIALS OUTSIDE THE ENCLOSURE. | | | A.8.2.3.1EXHAUST SYSTEMS SHOULD NOT | | | TERMINATE UNDER STRUCTURES OR WHERE THE | | | EXHAUST MIGHT BE DRAWN INTO THE | | | VENTILATION INTAKES. | | | | | | 2004 FMC 804.3.5 #3, WHERE THE | | | TERMINATION IS LOCATED BELOW AN ADJACENT | | | ROOF STRUCTURE, THE TERMINATION POINT | | | SHALL BE LOCATED AT LEAST 3 FT FROM THE | | | ROOF STRUCTURE. | | | | | | PLEASE NOTE, WHILE ZONING ALLOWS | | | MECHANICAL EQUIPMENT TO ENCROACH 4 FT | | | INTO THE SETBACK, GENERATORS SHALL | | | MAINTAIN THE REQUIRED ABOVE MENTIONED | | | CLEARANCES TO THE ADJACENT PROPERTY | | | STRUCTURES, I.E. FENCE, BUILDING, | | | WINDOWS, DOORS, OR OPENINGS. | | | | | | PROVIDE MANUFACTURE'S INSTALLATION | | | INSTRUCTIONS AT THE JOBSITE FOR THE | | | FIELD INSPECTOR. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-05-05 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-05-05 |
Time |
09:01 |
Rev Time |
0.15 |
| Received By |
tgordon |
Date |
2006-05-05 |
Time |
09:01 |
Sent To |
P |
|
| Notes |
| 2006-05-05 00:00:00 | *** DENIED *** | | | 1) PLEASE SEE ZONING NOTES. | | | | | | 2) PLEASE BE ADVISED,GENERATOR EXHUST | | | MUST BE TEN FEET AWAY FROM ANY BUILDING | | | OPENINGS (WINDOWS, DOORS, ROOF & EAVE | | | VENTS), AND TEN FEET AWAY FROM ADJECENT | | | BUILDING OPENS. PER 2004 FBC/M 401.5.1 . | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2006-05-05 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-05-05 |
Time |
13:11 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2006-05-05 |
Time |
13:11 |
Sent To |
G |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2006-05-30 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-05-30 |
Time |
08:27 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-05-30 |
Time |
08:27 |
Sent To |
I |
|
| Notes |
| 2006-05-30 00:00:00 | GENERATOR CAN ONLY ENCROACH 4FT INTO A | | | SETBACK. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2006-04-25 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-04-25 |
Time |
15:09 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-04-25 |
Time |
15:09 |
Sent To |
I |
|
| Notes |
| 2006-04-25 00:00:00 | DENIED, | | | 1. NEED TO SHOW THE LOCATION OF THE | | | GENERATOR ON THE FULL SIZE SURVEY WITH | | | SETBACK FROM PROPERTY & FROM STRUCTURE. | | | 2. THE SURVEY THAT SHOWS THE GENERATOR | | | IS A BLOWN UP AND DOES NOT SHOW THE | | | COMPLETE PROPERTY. | | | | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|