| Plan Review Stops For Permit 06040434 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2006-09-11 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2006-09-11 |
Time |
08:16 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2006-09-11 |
Time |
08:16 |
Sent To |
|
|
| Notes |
| 2006-09-11 00:00:00 | EXT#0001 WAS ADDED FOR THE ADDRESS OF | | | 5816 GEORGIA AVE |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2006-12-04 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-12-04 |
Time |
11:25 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-12-04 |
Time |
11:25 |
Sent To |
FIRE |
|
| Notes |
| 2006-12-04 11:29:59 | PER TELEPHONE CONVERSATION WITH HENRY KREH, P.E., I | | | CHANGED THE STANDARDS REFERENCED FOR CONCRETE AND | | | MASONRY (ACI, ASCE & TMS) TO THE 2002 EDITIONS AS | | | REFERENCED IN THE 2004 FBC. | | | REVISED SHEETS A-1, S-1 AND S-2 ARE OK. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2006-10-11 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-10-11 |
Time |
11:03 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-10-11 |
Time |
11:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2006-09-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-09-27 |
Time |
12:36 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-09-27 |
Time |
07:12 |
Sent To |
|
|
| Notes |
| 2006-09-27 00:00:00 | DENIED | | | | | | 1) PRODUCT APPROVAL FOR FIXED WINDOWS | | | WAS SUBMITTED AND THE PLANS SPECIFY | | | SINGLE HUNG WINDOWS. | | | | | | 2) BUILDING OCCUPANCY WAS CHANGED TO F-1 | | | BUT THE HEIGHT AND AREA LIMITATIONS WERE | | | NOT REVISED. | | | | | | 3) VALUE OF THE JOB NEEDS TO BE REVISED | | | TO REFLECT THE SCOPE OF THE WORK. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-09-07 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-09-07 |
Time |
16:21 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-09-07 |
Time |
16:21 |
Sent To |
|
|
| Notes |
| 2006-09-08 00:00:00 | DENIED BY BUILDING | | | | | | 1)A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. THE NOC THAT WAS | | | SUBMITTED DOES NOT HAVE THE RECORDING | | | STAMP ON IT. | | | | | | 2) PRODUCT APPROVALS SUBMITTED | | | WITH PERMIT APPLICATION AFTER OCTOBER 1, | | | 2003 ARE REQUIRED TO COMPLY WITH THE | | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR | | | INFORMATION PLEASE SEE THE STATE WEBSITE | | | AT WWW.FLORIDABUILDING.ORG. PRODUCTS | | | WITH STATEWIDE APPROVAL ARE REQUIRED TO | | | BE SUBMITTED WITH A COVER SHEET THAT | | | LISTS THE PRODUCT IDENTITY NUMBER FROM | | | THE STATE. SUBMIT PRODUCT APPROVALS FOR | | | THE NEW EXTERIOR WINDOWS AND DOORS. IF | | | GLAZING IS NOT IMPACT RESISTANT, STORM | | | PANEL PRODUCT APPROVALS ARE REQUIRED | | | ALONG WITH AN INSTALLATION SCHEDULE AND | | | KEY PLAN. | | | | | | 3) THE DESCRIPTION OF WORK ON THE PERMIT | | | APPLICATION DOES NOT REFLECT THE SCOPE | | | OF WORK SPECIFIED ON THE PLANS. PLEASE | | | REVISE AND INCREASE THE VALUE OF THE | | | WORK LISTED ON THE PERMIT APPLICATION | | | ACCORDINGLY. | | | | | | 4) SPECIFY THE LEVEL OF ALTERATION FOR | | | THE PROJECT THE ON THE PLANS, AS | | | SPECIFIED IN THE 2004 FBC EXISTING | | | BUILDING CODE. | | | | | | 5) THE BUILDINGS OCCUPANCIES ARE LISTED | | | AS BUSINESS ON SHEET CS. HOWEVER, | | | OCCUPANT LOADS ARE GIVEN FOR BUSINESS | | | AND WAREHOUSE(STORAGE). IT APPEARS TO BE | | | MIXED OCCUPANCIES (STORAGE, BUSINESS AND | | | POSSIBILY FACTORY OCCUPANCIES). SPECIFY | | | THE OCCUPANCY AND OCCUPANT LOAD OF EACH | | | TENANT SPACE. SPECIFY THE TYPE OF | | | STORAGE(FBC 311).SEE FBC 302 & 302.3. | | | | | | 6) SPECIFY THE REQUIRED FIRE-RESISTANCE | | | RATINGS OF THE TENANT SEPARATION WALLS. | | | SEE FBC 302.3.2 AND TABLE 302.3.2. | | | | | | 7) SPECIFY THE FIRE RATING OF THE TENANT | | | SEPARATION WALL BETWEEN SUITES 3 AND 4 | | | IN BUILDING #2. | | | | | | 8) SPECIFY THE FIRE RATING OF THE TENANT | | | SEPARATION WALL (NEW AND EXISTING) | | | DIVIDING THE AREA OF BUILDING #1 INTO | | | TWO SEPARATE SPACES. | | | | | | 9) A FIRE BARRIER IS REQUIRED TO | | | SEPARATE THE ACCESSORY USE AREA OF THE | | | BUSINESS AREA FROM THE LARGE | | | STORAGE/WAREHOUSE AREA IN BUILDING #1. | | | THE BUSINESS AREA IS MORE THAN 10 PER | | | CENT OF THE AREA IN WHICH IT IS LOCATED. | | | SEE FBC 302.2. | | | | | | 10) PROVIDE DETAILS OF THE EXTERIOR WALL | | | PATCHES. INDICATE MATERIAL, ATTACHMENTS, | | | ETC. | | | | | | 11) THE TENANT BATHROOMS ARE REQUIRED TO | | | BE ACCESSIBLE. FBC EXISTING BUILDING | | | CODE SECTION 606.1. | | | | | | 12) INDICATE THE REQUIRED CLEAR FLOOR | | | SPACE AT THE ACCESSIBLE FIXTURES ON THE | | | PLANS. FBC 11-4.16.2, 11-4.19.3 AND | | | 11-4.23.3. | | | | | | 13) DOORS SHALL NOT SWING INTO THE CLEAR | | | FLOOR SPACE REQUIRED FOR ANY FIXTURE. | | | SEE FBC 11-4.23.2. | | | | | | 14) THE GRAB BAR AT THE REAR OF THE | | | WATER CLOSET IN THE DETAIL ON A1 IS | | | REQUIRED TO EXTEND A MINIMUM OF 12" PAST | | | THE CENTER LINE OF THE FIXTURE ON BOTH | | | SIDES. SEE FBC FIGURE 11-29(A). | | | | | | 15) FBC TABLE 602 REQUIRES EXTERIOR | | | WALLS WITHIN 5' OF THE PROPERTY LINE TO | | | HAVE A ONE HOUR FIRE RESISTANCE RATING. | | | FBC TABLE 704.8 SPECIFIES THAT NO | | | OPENINGS ARE ALLOWED IN EXTERIOR WALLS | | | WITHIN 5' OF THE PROPERTY LINES IF THE | | | WALLS ARE REQUIRED TO BE FIRE RATED. | | | THEREFORE THE OPENINGS IN THESE WALLS | | | ARE REQUIRED TO BE ENCLOSED WITH ONE | | | HOUR RATED CONSTRUCTION. ONE HOUR FIRE | | | RATED GLASS BLOCK MAY BE USED. | | | | | | NOTE: SEE NOTES AND MARKINGS ON PLAN. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-04-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-04-27 |
Time |
09:42 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-04-27 |
Time |
09:42 |
Sent To |
|
|
| Notes |
| 2006-04-27 00:00:00 | DENIED | | | | | | 1)A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2) SUBMIT PLANS DRAWN TO A MINIMUM 1/8" | | | SCALE AS REQUIRED BY FBC*106.1.3 CITY | | | AMENDMENTS. INDICATE ON THE PLANS THE | | | AREAS THAT WILL HAVE THE DRYWALL | | | REPLACED. INDICATE IF INSULATION WILL BE | | | REPLACED AND SPECIFY THE R-VALUE. | | | SPECIFY THE WALLS THAT WILL BE REMOVED. | | | | | | 3)FBC 106.1.1 INDICATE THE SCOPE OF THE | | | WORK ON THE PLANS. PROVIDE A COMPETE | | | DESCRIPTION OF ALL THE WORK TO BE | | | PERFORMED. | | | | | | 4) ADDRESSING ISSUES WILL NEED TO BE | | | RESOLVED BEFORE A PERMITS IS ISSUED. | | | HAVING TWO SEPARATE BUILDINGS ON ONE | | | PERMIT MAY BE A PROBLEM FOR INSPECTIONS | | | AND BEFORE A C.O. OR C.C. CAN BE ISSUED | | | THE WORK IN BOTH BUILDINGS WILL BE | | | REQUIRED TO BE COMPLETED. CONTRACTOR MAY | | | WISH TO PERMIT WORK IN EACH BUILDING | | | SEPARATELY. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2007-02-05 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-02-05 |
Time |
07:49 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2007-02-05 |
Time |
06:48 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2006-12-20 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-12-20 |
Time |
15:20 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2006-12-20 |
Time |
14:32 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2006-10-04 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-10-04 |
Time |
07:26 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2006-10-04 |
Time |
06:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2006-09-11 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-09-05 |
Time |
13:42 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2006-09-05 |
Time |
07:57 |
Sent To |
|
|
| Notes |
| 2006-09-05 00:00:00 | | | | NONCOMPLIANT | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW PRIOR TO ROUGH INSPECTION. ALLOW | | | AT LEAST ONE WEEK IN REVIEW. SHEET E-01 | | | IS THE ONLY REVISION REQUIRED FOR THIS | | | REVIEW. OTHER SHEETS NEED ONLY BE | | | REVISED FOR FIELD CHANGES. | | | | | | THE GROUNDING ELECTRODE CONDUCTOR SHOULD | | | BE CONNECTED TO THE GROUNDED (NEUTRAL) | | | CONDUCTOR IN THE GUTTER, AHEAD OF THE | | | INDIVIDUAL METERS, COMMON TO ALL FEEDS, | | | BOTH SERVICES. SEE ILLISTRATION 250.10, | | | 2002 NEC HANDBOOK. | | | | | | THE GROUNDING ELECTRODE CONDUCTOR MUST | | | BE 3/0 CU. ON BUILDING "A" TO COMPLY | | | WITH 250.66. | | | | | | THERE SHOULD NOT BE A GROUND WIRE IN THE | | | RISER. 250.6, BOTH SERVICES. | | | | | | THE NOTE "TYPICAL BEFORE AND AFTER | | | METER", AND THE GROUND FROM THE GUTTER | | | TO THE METER SHOWN IN BUILDING "B" | | | SERVICE, SHOULD BE REMOVED. 250.6, | | | OBJECTIONABLE CURRENTS, PARALLELING | | | PATHS. | | | | | | SEE BUILDING PLAN REVIEW NOTES AND | | | REVISE ELECTRICAL PLANS AS NEEDED. | | | INCORPORATE ELECTRICAL PLANS INTO THE | | | SUBMITTED SET, REMOVE OLD SHEETS, | | | SUBMIRT ONE SET OF OLD SHEETS TO AID | | | REVIEW. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-08-03 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-08-03 |
Time |
09:29 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2006-08-03 |
Time |
06:25 |
Sent To |
|
|
| Notes |
| 2006-08-03 00:00:00 | | | | | | | NONCOMPLIANT | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | PLEASE SHOW COMPLIANCE WITH CHAPTER 13 | | | FBC ENERGY CODE. INDICATE SENSORS AND | | | TIMER LOCATION ON THE PLAN. | | | | | | SHEET E-1 BUIULDING"A" DOES NOT SHOW | | | EMERGENCY CIRCUITS ON WITH LOCAL | | | CIRCUITS PER 701.11(F). | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-04-14 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-04-14 |
Time |
07:26 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2006-04-14 |
Time |
07:26 |
Sent To |
|
|
| Notes |
| 2006-04-14 00:00:00 | | | | THERE IS NOT SUFFICIENT CLARITY TO | | | REVIEW THE PLANS SUBMITTED. PLEASE HAVE | | | PLANS REDRAWN AND RESUBMIT SAME. 106.1.3 | | | FBC ADMINISTRATIVE SECTIION. | | | | | | THERE APPEARS TO BE ELECTRICAL SYMBOLS | | | ON THE PLAN, PLEASE INDICATE IF ALL IS | | | NEW WORK OR CLARIFY THE PORTION THAT IS. | | | | | | THE PERSON TAKING RESPONSIBILITY FOR THE | | | DESIGN OF THE PLAN MUST PRINT NAME AND | | | SIGN SAME. IF AN ARCHITECT OR ENGINEER, | | | MUST BE IN COMPLIANCE WITH 481 AND 471 | | | FS. THE PLAN SUBMITTED HAS AN ENGINEERS | | | TITLE BLOCK. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2006-10-05 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2006-10-05 |
Time |
17:10 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2006-10-05 |
Time |
17:09 |
Sent To |
|
|
| Notes |
| 2006-10-05 00:00:00 | *****APPROVED W/REMINDERS***** | | | | | | | | | | | | | | | 1.) NUMERICAL ADDRESS OF NO LESS THAN 6" | | | IN HEIGHT AND 1" IN WIDTH TO BE ON THE | | | BUILDING VISIBLE FROM GEORGIA AVENUE. | | | IDENTIFYING NUBERS OR ALPHABETS OF 3" IN | | | HEIGHT ARE REQUIRED FOR SUITES OR TENANT | | | SPACES. IF TENANT SPACES ARE EQUIPPED | | | WITH A REAR DOOR, A NUMBER IS REQUIRED | | | ON THE DOOR. | | | | | | | | | | | | | | | | | | | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2006-08-03 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2006-08-03 |
Time |
15:58 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2006-08-03 |
Time |
15:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2006-04-21 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-04-21 |
Time |
11:01 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-04-21 |
Time |
11:01 |
Sent To |
|
|
| Notes |
| 2006-04-21 00:00:00 | ******DENIED****** | | | | | | PLEASE NOTE THAT NOT ENOUGH INFORMATION | | | SUBMITTED FOR FIRE REVIEW AT THIS TIME. | | | PLEASE INDICATE IF WORK WILL IMPACT | | | EXISTING FIRE PROTECTION EQUIPMENT, EXIT | | | SIGNS/EMERGENCY LIGHTING ETC. | | | | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2007-01-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-01-30 |
Time |
17:39 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-01-30 |
Time |
17:39 |
Sent To |
|
|
| Notes |
| 2007-01-30 17:39:40 | TO "BOB"#8 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2006-12-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-12-20 |
Time |
11:54 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-20 |
Time |
11:54 |
Sent To |
E |
|
| Notes |
| 2006-12-20 11:54:58 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-12-04 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-12-04 |
Time |
11:46 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-12-04 |
Time |
11:46 |
Sent To |
|
|
| Notes |
| 2006-12-04 11:47:53 | ROUTED TO FIRE AND PLUMBING FOR REVIEWS. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-11-29 |
|
|
Cont ID |
|
| Sent By |
spalmer |
Date |
2006-11-29 |
Time |
20:01 |
Rev Time |
0.00 |
| Received By |
spalmer |
Date |
2006-11-29 |
Time |
20:01 |
Sent To |
B |
|
| Notes |
| 2006-11-29 20:02:19 | REV/TO RMCDOUGAL'S DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-09-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-23 |
Time |
17:19 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-23 |
Time |
17:19 |
Sent To |
|
|
| Notes |
| 2006-09-26 00:00:00 | TO "BOB"#8 | | 2006-09-23 00:00:00 | WAITING FOR "BOB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-08-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-16 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-16 |
Time |
11:49 |
Sent To |
|
|
| Notes |
| 2006-08-28 00:00:00 | TO "BOB"#5 | | 2006-08-16 00:00:00 | WAITING FOR "BOB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-07-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-07-17 |
Time |
16:17 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-07-17 |
Time |
16:17 |
Sent To |
|
|
| Notes |
| 2006-07-20 00:00:00 | TO "BOB"#15 | | 2006-07-17 00:00:00 | WAITING FOR "BOB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-04-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-04-27 |
Time |
09:42 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-04-13 |
Time |
15:57 |
Sent To |
|
|
| Notes |
| 2006-04-13 00:00:00 | TO "BOB"#9 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2006-04-14 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-04-14 |
Time |
09:12 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2006-04-14 |
Time |
09:12 |
Sent To |
|
|
| Notes |
| 2006-04-14 00:00:00 | NO MECHANICAL PLANS SUBMITTED, AND NO | | | MECHANICAL PERMIT NUMBER APPLIED FOR AT | | | THIS TIME. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2006-12-04 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-12-04 |
Time |
12:18 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-12-04 |
Time |
12:18 |
Sent To |
|
|
| Notes |
| 2006-12-04 12:20:44 | REVISION; | | | CHANGED FROM HI-LOW DRINKING FOUNTAINS TO SINGLE D/F'S | | | WITH CUP DISPENSOR. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2006-10-10 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-10-10 |
Time |
14:40 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-10-10 |
Time |
14:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2006-09-09 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-09-09 |
Time |
09:20 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-09-09 |
Time |
09:01 |
Sent To |
|
|
| Notes |
| 2006-09-09 00:00:00 | DENIED; | | | 1.BATHROOMS TO BE HANDICAP ACCESSIBLE. | | | FBC-2004 EXISTING BUILDING CODE SECTION | | | 606.1. SHOW SIZE OF BATHROOM, CLEAR | | | FLOOR SPACE, AND TURNING RADIUS IN ALL | | | BATHROOMS. BATHROOM DOORS CAN NOT SWING | | | INTO THE CLEAR FLOOR SPACE OF THE | | | LAVATORY. | | | 2.EXISTING BUILDING CODE SECTION 810.1, | | | IF THERE IS AN OCCUPANCY CHANGE THE NEW | | | OCCUPANCY IS SUBJECT TO DIFFERENT | | | PLUMBING FIXTURE REQUIREMENTS. SEE | | | FBC-2004 PLUMBING TABLE 403.1. DRINKING | | | FOUNTAINS WOULD BE REQUIRED. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-09-09 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-04-14 |
Time |
13:33 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-04-14 |
Time |
13:33 |
Sent To |
|
|
| Notes |
| 2006-04-14 00:00:00 | NO PLUMBING SHOWN ON PAPER WORK | | | SUBMITED. |
|
|