Plan Review Details - Permit 06040288
Plan Review Stops For Permit 06040288
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2006-04-27 Cont ID  
Sent By mjacobs Date 2006-04-27 Time 07:38 Rev Time 0.00
Received By mjacobs Date 2006-04-27 Time 07:10 Sent To PC
Notes
2006-04-27 00:00:00BUILDING PROVISO:
 TO BE IN PLACE AT C.O.:
  
 1) 424.2.17.1 OUTDOOR SWIMMING POOLS.
 OUTDOOR SWIMMING POOLS SHALL BE PROVIDED
 WITH A BARRIER COMPLYING WITH
 424.2.17.1.1 THROUGH 424.2.17.1.14.
  
 424.2.17.1.5 CHILD SAFETY BARRIER
 ASTM D5034 100 LB TENSILE STRNGTH
 ASTM D3787 150 LB BALL BURST
 STRENGTH
  
 2) 13-612.1.ABC.2.3.2 COVERS REQUIRED.
 SPAS AND HEATED SWIMMING POOLS SHALL BE
 EQUIPPED WITH A COVER DESIGNED TO
 MINIMIZE HEAT LOSS.
  
 3)424.1.3.1.2
 POOL WET DECKS SHALL BE UNIFORMLY SLOPED
 AT A MINIMUM OF 2 PERCENT TO A MAXIMUM
 OF 4 PERCENT AWAY FROM THE POOL OR TO
 DECK DRAINS TO PREVENT STANDING WATER.
 WHEN A CURB IS PROVIDED, THE DECK SHALL
 NOT BE MORE THAN 10 INCHES (254 MM)
 BELOW THE TOP OF THE CURB.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2006-04-21 Cont ID  
Sent By btrobaug Date 2006-04-21 Time 18:29 Rev Time 0.33
Received By btrobaug Date 2006-04-21 Time 18:21 Sent To P
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2006-04-24 Cont ID  
Sent By mperson Date 2006-04-24 Time 11:19 Rev Time 0.15
Received By mperson Date 2006-04-24 Time 11:19 Sent To B
Notes
2006-04-24 00:00:00NOTE: GAS PERMIT REQUIRED. GAS
 CONTRACTOR TO SUBMIT PLANS WITH PERMIT
 APPLICATION. ALL GAS INSPECTIONS TO BE
 COMPLETE BEFORE FINAL POOL INSPECTION.

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2006-04-10 Cont ID  
Sent By ptjomsto Date 2006-04-10 Time 11:20 Rev Time 0.00
Received By ptjomsto Date 2006-04-10 Time 11:20 Sent To  
Notes
2006-04-10 00:00:00HISTORIC APPROVED BY G JUDGE

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-04-21 Cont ID  
Sent By adarroug Date 2006-04-21 Time 11:03 Rev Time 0.00
Received By adarroug Date 2006-04-21 Time 11:03 Sent To E
Notes
2006-04-21 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2006-04-27 Time   Rev Time 0.00
Received By adarroug Date 2006-04-12 Time 11:38 Sent To  
Notes
2006-04-12 00:00:00TO "Z" BOX

Review Stop P PLUMBING
Rev No 1 Status P Date 2006-04-24 Cont ID  
Sent By mperson Date 2006-04-24 Time 11:09 Rev Time 0.45
Received By mperson Date 2006-04-24 Time 11:09 Sent To G
Notes
2006-04-24 00:00:00 
  
 ******PROVISO******
 FBC-2004 SEC. 424.2.15 GAS PIPING SHALL
 COMPLY WITH FBC-2004 FUEL GAS. SEPERATE
 PLANS AND PERMIT REQUIRED.

Review Stop Z ZONING
Rev No 1 Status P Date 2006-04-20 Cont ID  
Sent By mmclean Date 2006-04-20 Time 10:59 Rev Time 0.00
Received By mmclean Date 2006-04-20 Time 10:59 Sent To I
Notes
***NONE***