Plan Review Details - Permit 06040134
Plan Review Stops For Permit 06040134
Review Stop AD ADDRESSING
Rev No 2 Status F Date 2006-06-16 Cont ID  
Sent By lursu Date 2006-06-16 Time 10:20 Rev Time 0.00
Received By lursu Date 2006-06-16 Time 10:16 Sent To  
Notes
2006-06-16 00:00:00SENT E-MAIL TO DEVELOPER WITH THE
 REQUIREMENTS TO NAME THE PRIVATE STREET
 AS "CORPORATE WAY ".THE STREET NAME MUST
 BE DEPICTED ON THE APPROVED SITE PLAN
 BEFORE RELEASING NEW ADDRESS.

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2006-05-23 Cont ID  
Sent By lursu Date 2006-05-23 Time 13:59 Rev Time 0.00
Received By lursu Date 2006-05-04 Time 09:08 Sent To  
Notes
2006-05-23 00:00:00THE PRIVATE DRIVEWAY MUST BE NAMED FIRST
 BEFORE ISSUING AN ADDRESS
 E-MIAL NOTIFICATION WAS SENT TO GEORGE
 CANTONIS @[email protected] ON
 MAY 19/06
2006-05-19 00:00:00NEW ADDRESS REQUIRED BASED ON THE MAIN
 ROAD ENTRANCE.THE PERIVATE ROAD MUST BE
 NAMED BEFORE ISSUING ANY ADDRESSES.
2006-05-04 00:00:00PROJECT UNDER REVIEW

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-05-18 Cont ID  
Sent By jwitmer Date 2006-05-18 Time 16:43 Rev Time 7.77
Received By jwitmer Date 2006-05-18 Time 16:43 Sent To  
Notes
2006-05-18 00:00:00BUILDING PLAN REVIEW
 PERMIT: 06040134
 ADD: 2216 45TH ST
 CONT:O'CONNORS& TAYLOR, INC.
 TEL: (561)863-7349
  
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
  
 1)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 2) PLEASE CONTACT LILI URSA MIS
 ADDRESSING TECHNITION FOR THE CORRECT
 ADDRESS. CITY RECORDS INDICATE THE
 CORRECT ADDRESS TO BE 2200 45TH STREET
 FOR THIS PARCEL. CONTACT LILI @ (561)
 805-1239.
  
 3) FL S S 713.13
 NOTICE OF COMMENCEMENT, TO BE FILED
 WITH THE CLERK OF THE COURT BEFORE A
 PERMIT WILL BE ISSUED. NOTE: 713.13(2)
 IF THE WORK DESCRIBED IN THE NOTICE OF
 COMMENCEMENT IS NOT ACTUALLY COMMENCED
 WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF, SUCH NOTICE IS NULL & VOID.
  
 4)DLW ARCHITECTS- AA0002714 THE
 CERTIFICATE OF AUTHORIZATION IS NULL &
 VOID SINCE 02/28/2003.
 481.219 F.S.CERTIFICATE OF
 AUTHORIZATION.THE TITLE BLOCK FOR ANY
 SHEET BEARING THE NAME OF AN ARCHITECT
 PRACTICING UNDER A FICTITIOUS NAME, A
 CORPORATION, OR A PARTNERSHIP, OFFERING
 ARCHITECTURAL SERVICES, SHALL INCLUDE
 THE CERTIFICATE OF AUTHORIZATION
 NUMBER.ADD THE NUMBER TO EACH SHEET.
 THIS MAY BE ADDED BY HAND.
  
 5) ALL A-10 SHEETS (PRODUCT APPROVALS)
 THE DESIGN PROFESSIONAL FAILED TO SIGN
 AND SEAL THESE SHEETS.
 PLANS, SPECIFICATIONS,REPORTS OR
 OTHER DOCUMENTS PREPARED BY THE DESIGN
 PROFESSIONAL AND BEING FILED FOR PUBLIC
 RECORD SHALL HAVE THE SIGNATURE AND
 SEAL OF THE DESIGN PROFESSIONAL AFFIXED
 TO THE DOCUMENT.
 FL STATE STAT: 61G15-23.002 ENGINEERS
 FL ATATE STAT: 61G16.003 ARCHITECTS
  
 6) THIS STRUCTURE IS CONCIDERED A
 THRESHOLD BUILDING REQUIRING (3) OF ALL
 DOCUMENTS TO BE SUBMITTED TO THE
 BUILDING DEPARTMENT, PLANS, REVISIONS,
 LETTERS,AND OR SUBMITTALS,ETC
  
 7A) WPB AMENDMENT 105.13.6. W.P.B.
 CONSTRUCTION SERVICES DEPARTMENT
 REQUEST FOR THRESHOLD BUILDINGS A
 SPECIAL INSPECTOR AS REQUIRED BY S.
 553.79(5) FLORIDA STATUTES TO THE MIN-
 IMUM INSPECTIONS REQUIRED BY THIS CODE.
 CONTACT HAROLD PISKURA MANAGER OF THE
 SPECIAL INSPECTOR PROGRAM AT (561)
 805-6711 FOR FURTHER INFORMATION BEFORE
 THE PERMIT MAY BE ISSUED.
  
 7B)FL S. S. 553.71(7) " THRESHOLD
 BUILDING" MEANING ANY BUILDING WHICH IS
 GREATER THAN (3) STORIES OR 50 FT IN
 HEIGHT, OR WHICH HAS AN ASSEMBLY OCCUPAN
 CY CLASSIFICATION AS DEINED IN THE
 FLORIDA BUILDING CODE WHICH EXCEEDS
 5,000 SQ FT IN AREA AND AN OCCUPANT
 CONTENT OF GREATER THAN 500 PERSONS.
 105.13.1 THE ENFORCING AGENCY SHALL
 REQUIRE A SPECIAL INSPECTOR TO PERFORM
 SRUCTURAL INSPECTIONS ON A THRESHOLD
 BUILDING PURSUANT TO A STRUCTURAL INSPEC
 TION PLAN PREPARED BY THE ENGINEER OF
 RECORD. THE STRUCTURAL INSPECTION PLAN
 MUST BE SUBMITTED TO THE ENFORCING
 AGENCY PRIOR TO THE ISSUANCE OF A
 BUILDING PERMIT FOR THE CONSTRUCTION OF
 A THRESHOLD BUILDING. THE PURPOSE OF
 THE SRUCTURAL INSPECTION PLAN IS TO
 PROVIDE SPECIFIC INSPECTION PROCEDURES
 AND SCHEDULES SO THAT THE BUILDING CAN
 BE ADEQUATELY INSPECTED FOR COMPLIANCE
 WITH THE PERMITTED DOCUMENTS.
 T-0.01 INSPECTION PLAN DOESN'T
 INDICATE ANY SHORING OR RESHORING IN THE
 INSPECTION PLAN, NOR LENGTH OF TIME
 SHORING SHOULD BE PLACED THERE.
  
 8) SOILS REPORT SUBMITTED IS A COPY OF
 THE SOILS ENGINEERS' SIGNATURE. NO
 RAISED SEAL.
 PLANS, SPECIFICATIONS,REPORTS OR
 OTHER DOCUMENTS PREPARED BY THE DESIGN
 PROFESSIONAL AND BEING FILED FOR PUBLIC
 RECORD SHALL HAVE THE SIGNATURE AND
 SEAL OF THE DESIGN PROFESSIONAL AFFIXED
 TO THE DOCUMENT.
 FL STATE STAT: 61G15-23.002 ENGINEERS
 FL ATATE STAT: 61G16.003 ARCHITECTS
  
 9) 109.3.10* IMPACT OF CONSTRUCTION. ALL
 CONSTRUCTION ACTIVITY REGULATED BY THIS
 CODE SHALL BE PERMORMED IN A MANNER SO
 AS NOT TO ADVERSLY IMPACT THE CONDITION
 OF ADJACENT PROPERTY, UNLESS SUCH
 ACTIVITY IS PERMITTED TO AFFECT SAID
 PROPERTY PURSUANT TO A CONSENT BY THE
 APPLICABLE PROPERTY OWNER, UNDER TERMS &
 CONDITIONS AGREEABLE TO THE APPLICABLE
 PROPERTY OWNER.THIS INCLUDES BUT IS NOT
 LIMITED TO THE CONTROL OF DUST, NOISE,
 WATER OR DRAINAGE RUN-OFF, DEBRIS, AND
 THE STORAGE OF CONSTRUCTION MATERIALS.
 NEW CONSTRUCTION ACTIVITY SHALL NOT
 ADVERSELY IMPACT HISTORICSURFACE WATER
 DRAINAGE FLOWS SERVING ADJACENT
 PROPERTIES, & MAY REQUIRE SPECIAL
 DRAINAGE DESIGNCOMPLYING WITH
 ENGINEERING STANDARDS TO PRESERVE THE
 POSITIVE PATTERNS OF THE AFFECTED
 SITES.ACCORDINGLY, DEVELOPERS,
 CONTRACTORS, AND OWNERS OF ALL NEW
 RESIDENTIAL DEVELOPMENET, INCLUDING
 ADDITIONS, POOLS, PATIOS, DRIVEWAYS,
 DECKS, OR SIMILAR ITEMS, ON EXISTING
 PROPERTIES RESULTING IN A DECREASE IN
 EXCESS OF 800SQ FT OF PERMEABLE LAND
 AREA ON ANY PARCELL SHALL AS A PERMIT
 CONDITION, PROVIDE A PROFESSIONALY
 PREPARED DRAINAGE PLAN CLEARLY
 INDICATING COMPLIANCE WITH THIS
 PARAGRAPH. UPON COMPLETION OF THE
 IMPROVEMENT, A CERTIFICATE FROM A
 LICENSED ENGINEER SHALL BE SUBMITTED TO
 THE INSPECTOR IN ORDER TO RECEIVE
 APPROVAL OF THE FINAL INSPECTION.
  
 10) 109.3.10.1 HURICANE PROTECTION.
 IT SHALL BE UNLAWFUL FOR ANY PERSON TO
 ALLOW CONSTRUCTION RELATED MATERIALS
 EQUIPMENET AND DEBRIS TO REMAIN LOOSE OR
 OTHERWISE UNSECURED AT A CONSTRUCTION
 SITE FROM 24 HRS. AFTER A HURRICANE
 WATCH HAS BEEN ISSUED UNTIL THE
 HURRICANE WATCH OR WARNING HAS BEEN
 LIFTED. ALL SUCH CONSTRUCTION MATERIALS,
 EQUIPMENT AND DEBRIS SHALL BE EITHER
 REMOVED FROM THE CONSTRUCTION SITE OR
 SECURED IN SUCH A MANNER AS TO MINIMIZE
 THE DANGER OF SUCH CONSTRUCTION
 MATERIALS, EQUIPMENT AND DEBRIS CAUSING
 DAMAGE TO PERSONS OR PROPERTY FROM
 HIGHWINDS.
 ANY PERSONS WHO FAILS TO COMPLY TO
 REMOVE OR SECURE THE CONSTRUCTION
 MATERIALS EQUIPMENT AND DEBRIS WITHIN
 24 HRS AFTER A HURRICANE WATCH HAS BEEN
 ISSUED SHALL BE SUBJECT TO A FINE NOT TO
 EXCEED $500.00.
 IN ADDITION TO THE ABOVE, A LICENSED
 CONTRACTOR WHO VIOLATES THIS SECTION
 SHALL BE SUBJECT TO DISCIPLINE PURSUANT
 TO SECTION 113 OF THIS CHAPTER.
  
 11) 110.2* W. P. B. ADMINISTRATIVE CODE,
 INFORMATION THAT IS REQUIRED FOR RECORD
 KEEPING & FOR CERTIFICATE OF OCCUPANCY:
 A) THE EDITION OFTHE CODE UNDER WHICH
 THE PERMIT WAS ISSUED.
 B) THE USE AND OCCUPANCY, IN ACCORDANCE
 WITH THE PROVISIONS OF CHAPTER 3.
 C) THE TYPE OF CONSTRUCTION AS DEFINED
 IN CHAPTER 6, TABLE 601.
 D) THE DESIGN OCCUPANT LOAD, SEE 1004.
 E) IF AN AUTOMATIC SPRINKLER SYSTEM IS
 PROVIDED, WHETHER THE SPRINKLER SYSTEM
 IS REQUIRED.
 F) ANY SPECIAL STIPULATIONS & CONDITIONS
 OF THE BUILDING PERMIT.
 G) NUMBER OF UNITS
 H) NUMBER OF FLOORS
 I) NUMBER OF BEDROOMS
 J) NUMBER OF ROOMS
 K) NUMBER OF BEDROOMS
 L) SQ. FT. LIV SPACE/ FL
 M) SQ. FT. FOOTPRINT
 N) SQ. FT. UNDER ROOF (TOTAL)
 O) OCCUPANT LOAD
 P) FLOOD ZONE
 Q) MEAN ROOF HEIGTH, A-0.01 PLANS
 INDICATE FROM GRADE TO PLANK @ ROOF, SEE
 A-5.12 DETAIL# 1 TRUSSES NO CONCRETE
 PLANK.MEAN ROOF HEIGHT. THE AVERAGE OF
 THE ROOF EAVE HEIGHT AND THE HEIGHT TO
 THE HIGHEST POINT ON THE ROOF SURFACE,
 EXCEPT THAT EAVE HEIGHT SHALL BE USED
 FOR ROOF ANGLE OF LESS THAN OR EQUAL TO
 10 DEGREES (0.1745 RAD). GREATER THAN
 50'-0".
  
 12) 1609.1.4(1) IN WIND BORNE DEBRIS
 REGIONS, EXTERIOR GLAZING THAT RECEIVES
 POSITIVE PRESSURE IN BUILDINGS SHALL BE
 ASSUMED TO BE OPENINGS UNLESS SUCH
 GLAZING IS IMPACT RESISTANT OR PROTECTED
 WITH AN IMPACT RESISTANT COVERING MEET-
 ING THE REQUIREMENTS OF SSTD 12, ASTM
 E 1886 AND ASTM E 1996 OR MIAMI-DADE.
 1) GLAZED OPENINGS LOCATED WITHIN 30 FT
 OF GRADE SHALL MEET THE REQUIREMENTS OF
 LARGE MISSLE TEST.
  
 13) WPB ADMIN CODE 106.3* PRODUCT
 APPROVALS. THOSE PRODUCT WHICH ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.
  
 14) THE DESIGNER OF RECORD PRINTING THE
 PRODUCT APPROVALS AS PART OF THE PLAN
 MAKES IT DIFFICULT TO SEE WHAT APPROVALS
 ARE PRESENT AND WHICH AREN'T. ALSO NOTE
 IF THE CONTRACTOR CHANGES OUT PRODUCTS
 ( A REVISION) THE PRODUCT APPROVALS
 PRINTED ON THE ARCHITECTURAL SHEETS WILL
 BE CHARGED A BASE FEE OF $50.00 AND
 $10.00 A PAGE WHERE AS THE PRODUCT
 APPROVAL ITSELF IS CHARGED A TOTAL OF
 $60.00.
  
 15) FL BLD CODE CHAP 13 ENERGY EFFICENCY
 PROVIDE ENERGY CALS/ W MANUAL "J".
 PLEASE USE THE 2004 FORMS. IF A DESIGN
 PROFESSIONAL PRODUCES THE ENERGY CALS,
 MUST BE SIGNED AND SEALED.
  
 16A) PLANS DO NOT SHOW AN ACCESSIBLE
 ENTRANCE, PASSENGER LOADING ZONE,
 11-4.1.2(1). FIGURE 10 ACCESS AISLE AT
 PASSENGER LOADING ZONE.
  
 16B) 11-4.1.3(1) AT LEAST ONE ACCESSIBLE
 ROUTE COMPLYING WITH 11-4.3 SHALL
 CONNECT ACCESSIBLE BUILDINGS OR FACILITY
 ENTRANCES WITH ALL ACCESSIBLE SPACES AND
 ELEMENTS WITHIN THE BUILDING OR
 FACILITY.
  
 17) A-0.1.1 THE PLANS DO NOT SHOW AN
 ACCESSIBLE ROUTE TO 45TH ST.11-4.1.2(1)
 AN ACCESSIBLE SITE SHALL MEET THE
 FOLOWING MINIMUM REQUIREMENTS:
 (1) AT LEAST ONE ACCESSIBLE ROUTE
 COMPLYING WITH SECTION 11-4.3 SHALL BE
 PROVIDED WITHIN THE BOUNDRY OF THE SITE
 FROM PUBLIC TRANSPORTATION STOPS,
 ACCESSIBLE PARKING SPACES, PASSENGER
 LOADING ZONES IF PROVIDED, AND PUBLIC
 STREETS OR SIDEWALKS, AND ACCESSIBLE
 BUILDING ENTRANCE.
  
 18) SHEET A-0.1.1 INDICATES THERE TO BE
 A TOTAL OF 101 PARKING SPACES REQUIRING
 (5) HANDICAPPED PARKING SPACES NOT 4.
 SEE 11-4.1.2(5) 101-150 +5 ACCESSIBLE
 SPACES.
  
 19) A-0.04A THE POOL EQUIPMENT BUILDING
 AND PAVILION BOTH INDICATE STRUCTURAL
 DETAILS ON SHEET SA3 NOT FOUND IN PLANS.
 ARE THESE STRUCTURES TO BE PART OF THIS
 PERMIT? WHAT BUILDING TYPE?
  
 20) A-0.04A PLANS FOR THE POOL EQUIPMENT
 AND PAVILION BOTH INDICATE FIBERGLASS
 SHINGLES. SUBMIT PRODUCT APPROVALS.
 RULE 9B-72.
  
 21) A-0.04B PLANS INDICATE FOOTER
 INFORMATION ON S1.3, ROOF FRAMING ON
 SHEET S2.3 & 6.1, WHERE?
  
 22) A-0.05HEADING: RAMPS/ LANDING
 LENGTH SHALL BE A MINIMUM OF 60". SEE
 11-4.8.4(2)ALL LANDINGS ON RAMPS SHALL
 BE NOT LESS THAN 60 INCHES (1524 MM)
 CLEAR, AND THE BOTTOM OF EACH RAMP SHALL
 HAVE NOT LESS THAN 72 INCHES (1829 MM)
 OF STRAIGHT AND LEVEL CLEARANCE.
  
 23) A-1.01,A-2.01 & A2.02 DOOR# 142 &
 142A MISSING THE 18" ON THE PULL LATCH
 SIDE OF DOOR.
 11-4.13.6 MANEUVERING CLEARENCES
 AT DOORS. MINIMUM MANEUVERING CLEARENCES
 AT DOORS THAT ARE NOT AUTOMATIC OR
 POWER-ASSISTED SHALL BE AS SHOWN IN
 FIG. 25. THE FLOOR OR GROUND AREA WITH
 IN THE REQUIRED CLEARENCES SHALL BE
 CLEAR & LEVEL.
  
 24)A-1.06 DETAIL# 9 ROOF HATCH INDICATES
 SHEET A6.02 DETAILS 1,2,3&4 WHERE?
  
 25)A-1.06 DETAIL# 2, DETAIL INDICATES
 USE OF STANDING SEAM METAL ROOF, WITH
 THE USE OF A CONTINIOUS VENTCOVERED WITH
 SHINGLES. PROVIDE THE PRODUCT APPROVALS
 WITH THIS TYPE OF APPROVED APPLICATION.
 ADDITIONAL INFORMATION REQUIRED.
  
 26) A-1.06 DETAIL# 10, INDICATES THE USE
 OF SHINGLES FOR A CRIKET, IS THIS ALSO
 TO BE USED WITH A STANDING SEAM METAL
 ROOF, IF SO PROVIDE THE PRODUCT APPROVAL
 WITH THIS TYPE OF APPLICATION.
 ADDITIONAL INFORMATION REQUIRED.
  
 27) A-1.06 DETAIL# 7 IS FOR THE ACCESS
 LADDER MISSING ANCHOR LENGTH? PROVIDE A
 SECTION THROUGH, HOW FAR DOES THE LADDER
 AND SIDE RAILS RUN WITHIN AN INCH OF THE
 ROOF HATCH?
  
 28) A2.01 DOOR# 112,114& 116 SEE:
 1008.1.8.8 DURING ITS SWING, ANY DOOR IN
 A MEANS OF EGRESS SHALL LEAVE
 UNOBSTRUCTED AT LEAST ONE HALF OF THE
 REQUIRED WIDTH OF AN AISLE, CORRIDOR,
 PASSAGEWAY, OR LANDING, NOR PROJECT MORE
 THAN 7 INCHES (178 MM) INTO THE REQUIRED
 WIDTH OF AN AISLE, CORRIDOR, PASSAGEWAY
 OR LANDING, WHEN FULLY OPEN.
  
 29) A-2.01 GUEST ROOM DOORS 115& 115A,
 PLANS DO NOT PROVIDE THE INFORMATION ON
 THE EXTERIOR SIDE DOOR LANDING.
 11-4.13.6 MANEUVERING CLEARENCES
 AT DOORS. MINIMUM MANEUVERING CLEARENCES
 AT DOORS THAT ARE NOT AUTOMATIC OR
 POWER-ASSISTED SHALL BE AS SHOWN IN
 FIG. 25. THE FLOOR OR GROUND AREA WITH
 IN THE REQUIRED CLEARENCES SHALL BE
 CLEAR & LEVEL.
  
 30) A-2.02 LAUNDRY CHUTE PROVIDE
 INFORMATION AS TO THE ACTUAL LAUNDRY
 CHUTE AND ACCESS DOORS THAT ARE BUILT
 INTO THE CHUTE.
  
 31) 707.13.1 REFUSE AND LAUNDRY CHUTE
 ENCLOSURES.
 A SHAFT ENCLOSURE CONTAINING A REFUSE OR
 LAUNDRY CHUTE SHALL NOT BE USED FOR ANY
 OTHER PURPOSE AND SHALL BE ENCLOSED IN
 ACCORDANCE WITH SECTION 707.4 . OPENINGS
 INTO THE SHAFT, INCLUDING THOSE FROM
 ACCESS ROOMS AND TERMINATION ROOMS,
 SHALL BE PROTECTED IN ACCORDANCE WITH
 THIS SECTION AND SECTION 715 . OPENINGS
 INTO CHUTES SHALL NOT BE LOCATED IN EXIT
 ACCESS CORRIDORS. OPENING PROTECTIVES
 SHALL BE SELF-CLOSING OR
 AUTOMATIC-CLOSING UPON THE ACTUATION OF
 A SMOKE DETECTOR INSTALLED IN ACCORDANCE
 WITH SECTION 907.10 , EXCEPT THAT
 HEAT-ACTIVATED CLOSING DEVICES SHALL BE
 PERMITTED BETWEEN THE SHAFT AND THE
 TERMINATION ROOM.
  
 32)A-2.02 LAUNDRY CHUTE ALSO HAS A
 WALL CUT SECTION W-11 INDICATING A 2 HR
 WALL, A-5.14 PROVIDES A SECTION THROUGH
 THE LAUNDRY CHUTE BUT THE SHAFT IS
 INTERRUPTED AT FLOOR LEVEL LOSING THE 2
 HR RATING AS DEPICTED.
  
 33) A-2.02 THE LAUNDRY ROOM ALSO DOESN'T
 INDICATE A DOOR TO THE TERMINATION ROOM
 OF THE LAUNDRY CHUTE?
  
 34) A-2.11 THE 2 BEDROOM ACCESIBLE UNIT
 IS MISSING THE 3'-0" CLEAR BETWEEN BEDS.
 11-9.2.2(1). AT THE FOOT OF THE KING
 SIZE BED THERE IS LESS THAN 36".
 11-9.2.2(2).
  
 35) A2-11 THE SAME 2 BEDROOM ACCESSIBLE
 UNIT THE KITCHEN SINK NEEDS TO BE
 ACCESSIBLE ALSO.11-9.2.2(2)AN
 ACCESSIBLE ROUTE COMPLYING WITH SECTION
 11-4.3 SHALL CONNECT ALL ACCESSIBLE
 SPACES AND ELEMENTS, INCLUDING
 TELEPHONES, WITHIN THE UNIT, SLEEPING
 ROOM, OR SUITE.
  
 36) A-2.11 ONE BEDROOM ACCESSIBLE KING
 MISSING A CLEAR 36" PATH TO THE CLOSET.
 11-9.2.2(4)(4) IF FIXED OR BUILT-IN
 STORAGE FACILITIES SUCH AS CABINETS,
 SHELVES, CLOSETS, AND DRAWERS ARE
 PROVIDED IN ACCESSIBLE SPACES, AT LEAST
 ONE OF EACH TYPE PROVIDED SHALL CONTAIN
 STORAGE SPACE COMPLYING WITH SECTION
 11-4.25 . ADDITIONAL STORAGE MAY BE
 PROVIDED OUTSIDE OF THE DIMENSIONS
 REQUIRED BY SECTION 11-4.25 .
  
 37) THE SAME SITUATION WITH THE KITHCEN
 SINK, IN CORNER CAN'T MAKE A FRONTAL
 APPROACH REQUIRES 30" CLEAR, 15"
 CENTERLINE OF SINK.
 11-4.24.2 SINKS, HEIGHT. SINKS SHALL
 BE MOUNTED WITH THE COUNTER NO HIGHER
 THAN 34" ABOVE THE FINISH FLOOR.
 11-4.24.3 KNEE CLEARENCE THAT IS AT
 LEAST 27" HIGH 30" WIDE, AND 19" DEEP
 SHALL BE PROVIDED UNDERNEATH SINKS.
  
 38) A-5.10 INDICATES VARIOUS WINDOWS AND
 DETAIL A3/ A9.08 THAT DO NOT HAVE
 ADEQUATE ATTACHMENT WHERE DEPICTD IN THE
 PLANS. THEY DO NOT HAVE FASTENING INTO
 STRUCTURAL MEMBERS INSTALLED AS
 ILLUSTRATED.
  
 39) A-5.11 DETAIL 6 & 6A:
 39A) BRICK VENEER/ CULTURED STONE: THE
 6"CLEAR INSPECTION SPACE OF THE
 FOUNDATION SIDEWALL EXTERIOR EXIST
 BETWEEN THE VENEER AND THE TOP OF ANY
 SOIL, SOD, MULCH OR OTHER ORGANIC
 LANDSCAPING COMPONENT, DECK, APRON,
 PORCH, WALK OR ANY OTHER WORK
 IMMEDIATELY ADJACENT TO OR ADJOINING THE
 STRUCTURE.
 1405.3.2 MASONRY.
 FLASHING AND WEEPHOLES SHALL BE LOCATED
 IN THE FIRST COURSE OF MASONRY ABOVE
 FINISHED GROUND LEVEL ABOVE THE
 FOUNDATION WALL OR SLAB, AND OTHER
 POINTS OF SUPPORT, INCLUDING STRUCTURAL
 FLOORS, SHELF ANGLES AND LINTELS WHERE
 ANCHORED VENEERS ARE DESIGNED IN
 ACCORDANCE WITH SECTION 1405.5 .
  
 39B)DETAIL 5A)EFIS SYSTEMS,2603.9.2
 CLEARANCE BETWEEN EARTH AND FOAM
 PLASTICS APPLIED TO THE EXTERIOR WALL
 SHALL BE NOT LESS THAN 6 INCHES (152
 MM). NOTE DETAIL 6A) DOESN'T INDICATE
 USE OF EFIS BUT THE USE OF 7/8" STUCCO?
  
 39C) PLANS DO NOT INDICATE COMPLIANCE
 WITH ANCHORAGE TO METAL STUD WALL.
 1405.5 ANCHORED MASONRY VENEER.
 ANCHORED MASONRY VENEER SHALL COMPLY
 WITH THE PROVISIONS OF SECTIONS 1405.5 ,
 1405.6 , 1405.7 AND 1405.8 AND SECTIONS
 6.1 AND 6.2 OF ACI 530/ASCE 5/TMS 402.
  
 40) SHEET A-10.XX PRODUCT APPROVALS
 PLEASE SUBMIT PRODUCT APPROVALS IN THE
 BROCHURE FORM, IF ON ARCHITECTURAL
 SHEETS THEY MUST BE SEALED.
 PLANS, SPECIFICATIONS,REPORTS OR
 OTHER DOCUMENTS PREPARED BY THE DESIGN
 PROFESSIONAL AND BEING FILED FOR PUBLIC
 RECORD SHALL HAVE THE SIGNATURE AND
 SEAL OF THE DESIGN PROFESSIONAL AFFIXED
 TO THE DOCUMENT.FL S S 61G15-23.002
 NOTE IF A REVISION COMES IN FOR CHANGE
 OF A SYSTEM YOU WILL BE CHARGES $50BASE
 FEE AND AN ADDITIONAL $10.00 PER SHEET.
 PRODUCT APPROVAL REVISION THAT COEMS IN
 IN BROCHURE FORM IS CHARGED BASE FEE OF
 $50.00 AND AN ADDITIONAL $10.00.
  
 41)PRODUCT APPROVALS SUBMITTED ARE
 EITHER FILED UNDER THE 2001 FBC OR THEY
 WERE FILED WITH REPORTS THAT HAD BEEN
 SUBMITTED UNDER THE FBC 2004 CODE AND
 WERE PULLED BECAUSE THEY DIDN'T STATE
 THE CODE EDITION. NONE OF THE REPORTS
 THAT WERE SUBMITTED ARE ON THE FL WEB
 SITE CURRENTLY!!!!
 FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORTS, MISSING REPORTS ARE AS
 FOLLOWS:
 A) WINDOWS FIXED
 B) WINDOWS HORIZONTAL SLIDERS
 C) WINDOWS SINGLE HUNG
 D) GLAZED DOORS
 E) STEEL DOORS
 F) WALL LOUVERS
 G) TRUSS TIES
 H) HARDI-PLANK
 I) EFIS SYSTEMS NOT SYSTEMS LIMITATIONS
  
 FOR HORIZONTAL USE
 J) DENSE-GLASS
 K) ASPHALT SHINGLES
 L) NON-STURTURAL METAL ROOFING
 M) FLAT ROOF - NO INFORMATION WAS
 SUBMITTED AT ALL.
 NOTE HIGHLIGHT WHICH SUB-SYSTEM THAT
 WILL BE USED. NOTE IF LIMITATION
 NUMBER 7 OR 9!!!!!!!!!
  
 42) JAMES HARDI PLANK WHEN CONTRACTOR
 SUBMITS THE UPDATED REPORT HIGHLIGHT
 WHICH SYSTEM IS TO BE USED AND FASTENING
 DEVICE IN THE WIND SPEED TABLES.
  
 43) A5.14 DETAIL# 1 LAUNDRY CHUTE, THIS
 DETAIL IS MISSING THE 2 HR RATING
 BETWEEN FLOORS.
  
 44) S-0.01 SPECIFIC LOADS: ROOF, THERE
 IS NO BOTTOM CHORD LIVE LOADOF 10 PSF,
 TABLE 1607.1.
  
 45) S-0.01 WIND LOAD MISSING THE YEAR
 UNDER ASCE 7-XX.
  
 46) S-0.02 BASIS OF DESIGN WRONG YEAR
 FOR ASCE 7-98.
  
 47) S-0.02 OPENING FASTENING CHART THE
 WRONG WIND ZONE, INDICATES 110/120.
  
 48) S-0.03 THERE IS (3) CHARTS ON THE
 LEFT SIDE OF THE PAGE ALL QUOTING THE
 WRONG CODE SECTIONS.
  
 49) S-1.04 PROVIDE THE TRUSS LAYOUT FOR
 THIS BUILDING WITH THE LOADS TO BE
 IMPOSED, UPLIFT, LATERAL AND GRAVITY.
 PROVIDE WHAT TYPE OF ANCHOR AND THE
 LOADS LISTED IN THE MANUFACTURERS
 BROCHURE.S-2.02 ALSO INDICATES SEE TRUSS
 MANUFACTURER FOR TRUSS LAYOUT. THE
 DESIGNER OF RECORD PROVIDES THE LAYOUT,
 THE TRUSS MANUFACTURER PROVIDES THE
 DETAILED SHOP DRAWINGS. THE DESIGNER OF
 RECORD TO REVIEW AND APPROVE THE SHOP
 TRUSS DRAWINGS.
  
 50) S-6.03DETAIL "F" BASE PLATE, MISSING
 THE THICKNESS OF THE TOP AND BOTTOM
 COLUMN PLATE?
  
 51) S-1.01 FRONT ENTRY AT DOUBLE SET OF
 DOUBLE DOORS, PLANS DO NOT PROVIDE A
 FOUNDATION DETAIL, OR CROSS SECTION
 INDICATING THE FOUNDATION FOR THIS
 SECTION.
  
 52) S-2.01 DISCREPANCY DETAILS A& B BOTH
 INDICATE METAL & WOOD TRUSSES?
  
 53) BEFORE A PERMIT TO CONSTRUCT, MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY. THE ACTUAL PERMIT
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026
  
  
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-05-11 Cont ID  
Sent By dpalmer Date 2006-05-14 Time 22:05 Rev Time 0.00
Received By dpalmer Date 2006-05-11 Time 22:04 Sent To  
Notes
2006-05-14 00:00:00******** UNSAT 2ND REVIEW *******
  
 **STAYBRIDGE SUITES, FIRST REVIEW UNDER
 2004 FBC.
  
  
 ** PLEASE KNOW, PLANS ORIGINALLY CAME IN
 UNDER THE 2001 FBC AND NOW PLANS ARE
 SUBMITTED UNDER THE 2004 FBC. PLEASE SEE
 MOST OF THE COMMENTS ARE NEW, HOWEVER
 SOME ARE FROM PREVIOUS REVIEW.
  
 ** PLEASE BE SURE TO COMPLETELY REMOVE
 ANY OLD/VOIDED SHEETS FROM SETS AND ONLY
 INSERT NEW REVISED SHEETS INTO COMPLETE
 SETS FOR REVIEW AND STAMPING.
  
  
 1) NOTE: PLEASE SEE ADDRESSING FOR
 PROJECT SHOULD BE ON TITLE BLOCK FOR
 LOCATION OF PROJECT.
 FAC61G1-16.004, 61G15-23.002
  
 2) NOTE: PLEASE CLARIFY TITLE BLOCK ON
 COVER SHEETS AND ALL TRADE SHEETS, AS
 THESE STATE THE ELECTRICAL ENGINEER OF
 RECORD AS UNDER THE ARCHITECTURAL FIRM?
 PLEASE ALSO SEE STRUCTURAL, MECHANICAL
 AND PLUMBING SHEETS AS THESE DO NOT
 CONTAIN ANY TITLE BLOCKS FOR THE
 ENGINEERS OR ENGINEERIN FIRMS AS LISTED
 ON COVER SHEETS.
 ** PLEASE SEE A PRINT OUT FROM THE
 STATE'S WEBSITE IS NOW ATTACHED TO
 NOTES, AS THE CERTIFICATE OF
 AUTHORIZATION NUMBER AS INDICATE ON
 TITLE BLOCKS FOR ARCHITECTURAL FIRM IS
 "NULL AND VOID" PER DEPARTMENT OF
 BUSINESS AND PROFESSIOAL REGULATION.
 PLEASE SEE ELECTRICAL SHEETS DO NOT
 INDICATE THIS AND LIST THE ENGINEER AS
 AN INDIVIDUAL?
 PLEASE SEE FAC 61G15-23.002, FS 471.023,
 IF ARCHITECTURAL FIRM IS OFFERING
 ENGIEERING SERVICES, PLEASE PROVIDE
 CERTIFICATE OF AUTHORIZATION FOR THIS.
 THE CA # WAS ADDED FOR ARCHITECTURAL
 FIRM AS REQUESTED ON PREVIOUS REVIEW
 HOWEVER AS NOTED ABOVE, SEEMS NOT BE
 ACTIVE.
 PLEASE SEE THE PRINTED NAME AND LICENSE
 NUMBER OF THE ARCHITECT IS ALSO REQUIRED
 ON TITLE BLOCKS FOR ALL SHEETS.
 FAC 61G1-16.004
 ** PLEASE KNOW, THIS COMMENT IS FOR ALL
 TRADES AND FOR ALL SHEETS WHETHER OR NOT
 COMMENT IS MADE BY OTHER REVIEWER(S).
  
 3) NOTE: PLEASE SEE FP SHEETS, AS ONE
 SHEET IS A COPY OF SIGNED AND SEALED
 PLANS SUBMITTED.
  
 4) NOTE: PLEASE KNOW, PLANS ARE NOW
 BEING SUBMITTED UNDER THE 2004 FBC,
 HOWEVER NO CHANGES IN ELECTRICAL DESIGN
 WERE MADE TO THE NEW 2004 CHAPTER 13.
 PLEASE SEE CHAPTER 13, 13-413.1ABC.1,
 PLEASE PROVIDE ALL WORST CASE CALCS, AND
 ADJUST AS NEEDED FOR LONGEST RUNS.
 PLEASE SEE 13-415.1.ABC.1.1, &.2, & .3
 WHICH GREATLY AFFECT ELECTRICAL DESIGN.
 COULD NOT LOCATE ANY INFORMATION FOR
 THIS ON PLANS.?
 PLEASE SEE ALL OTHER CHANGES IN CHAPTER
 13. FIXTURE TYPES, TANDEM WIRING ETC.
  
 5)NOTE: PLEASE PROVIDE COMPLETE
 PHOTO-METRICS FOR ALL EGRESS
 AREAS/PATHS.
 PLEASE SEE NFPA-101 2003, 7.8.1.3,
 7.9.2.2. PLEASE SEE STAIRS FOR EGRESS
 SHALL CONTAIN A MIN OF 10FT CANDLES AVG
 UNDER NORMAL CONDITIONS AND 1FT CANDLE
 AVG UNDER EM POWER.
 PLEASE SEE MIN REQUIRED FOR ALL OTHER
 PATHS SHALL BE 1FT CANDLE.
 PLEASE ALSO KNOW, AN EM BATTERY BACK UP
 FIXTURE OF SOME TYOE WILL BE REQUIRED IN
 THE MAIN ELECTRICAL ROOM.
  
 6) NOTE: PLEASE SEE NO INFORMATION WAS
 SUBMITTED FOR THE FIRE PUMP, FIRE PUMP
 CONTROLLER.
 PLEASE KNOW, ALL PERMITS, PLANS AND
 INFORMATION FOR THIS SHALLBE
 SUBMITTED. PLANS NOW INDICATE A FIRE
 PUMP LOCATED IN A DETACHED BUIDLING
 WHICH WILL FEED TWO DIFFERENT HOTELS.
 PLEASE KNOW, APPROVAL BY THE FIRE
 MARSHAL'S OFFICE SHALL FIRST BE OBTAINED
 FOR THIS SCENERIO. PLEASE ALSO KNOW,
 PERMIT FOR EITHER BUILDING CAN NOT BE
 PASSED FOR PERMITING UNTIL ALL
 INFORMATION, PLANS ETC FOR FIRE PUMP,
 FIRE PUMP CONTROLLER CAN BE REVIEWED. IF
 ELECTRICAL DRIVEN FIRE PUMP, PLEASE
 PROVIDE ALL INFORMATION.
 PLEASE SEE FP SEEM TO INDICATE
 ELECTRICAL FIRE PUMP, BUT UNCLEAR AT
 THIS TIME.
 PLEASE SEE NFPA-20 2002. PLEASE SUBMIT
 ALL RELEVANT INFORMATION FOR FIRE PUMP
 CONTROLLER ETC.
  
 7) NOTE: PLEASE SEE PLANS ARE NOW
 INDICATING A BACK UP GENERATOR OF SOME
 SORT? IF ANY PART OF THIS SYSTEM IS
 GOING TO BE INSTALLED, PLEASE SUBMIT ALL
 INFORMATION FOR ATS, GENERATOR,
 ELECTRICAL RISER, SUB BASE FUEL ETC.
 PLEASE SEE AN ATS IS BEING SHOWN ON
 PLANS AT THIS TIME, HOWEVER HOW THIS IS
 NOT BEING SHOWN WIRED INTO RISER?
 PLEASE KNOW, IF NO PART OF THIS SYSTEM
 IS GOING TO BE INSTALLED AT THIS TIME,
 PLEASE REMOVE FROM PLANS AS LONG AS ALL
 MIN LIFE SAFETY BACK UP SYSTEMS ARE
 PROVIDED BY OTHER MEANS.
 PLEASE SUBMIT ALL MANUFACTURE CUT
 SHEETS/SPEC FOR GEN, ATS'S, FIRE PUMP,
 FIRE PUMP CONTROLLER, AND ANY FUEL
 TANKS.
  
 8) NOTE: PLEASE SEE PANEL "P" ON SHOWS
 MCB AS REQUIRED, YET PANEL SCHEDULE
 SHOWS THIS PANEL AS "MLO". PLEASE KNOW,
 THIS PANEL IS NOW SHOWN IN A DETACHED
 STRUCTURE AND A MEANS OF DISCONNECT WILL
 BE REQUIRED PER 225.31.
  
 9) NOTE: PLEASE SEE PLANS INDICATE A
 "IT" , NETWORK RM? PLEASE SEE NFPA-75,
 AND NFPA-70, 645.
 PLEASE SHOW ALL ELECTRICAL MEETING 645.
 PLEASE ALSO SEE ANY OTHER REQUIREMENTS
 FOR A/C SYSTEMS, IF FOR THIS ROOM ALONE
 OR IF SYSTEM ALSO FEEDS OTHER AREAS AND
 POSSIBLE FIRE DAMPERS.
 PLEASE ALSO SEE MIN CONSTRUCTION FOR
 ROOM PARTITIONS.
  
 10) NOTE: PLEASE PROVIDE REFERENCES TO
 THE FOLLOWING CODES ON ELECTRICAL PLANS.
 NFPA-101 2003, NFPA-70 2002, NFPA-72
 2002, NFPA-110 2002, NFPA-20 2002.
  
 10) NOTE: PLEASE SEE PANEL "IC" SHOWN ON
 ELECTRICAL ROOM LAYOUT, HOWEVER NOT ON
 RISER.
 215.5
  
 11) NOTE: PLEASE CORRELATE GROUNDING
 ELECTRODE CONDUCTOR ON GROUNDING DETAIL
 AS SHOWN ON RISER.
 250.50, 215.5
  
 12) NOTE: PLEASE SEE 210.8B3 FOR
 KITCHENS, SEE ALL RECEPTS 15/20A 120 V
 SHALL BE GFI/GFI PROTECTED.
 PREVIOUS REVIEW COMMENT.
  
 13) NOTE: PLEASE SEE PREVIOUS REVIEW
 NOTED THE SERVICE ENTRANCE CONDUCTORS
 NOT BEING LARGE ENOUGH AND RESPONSE FROM
 DESIGN PROFESSIONAL MENTIONS SERVICE
 REVISED TO 2500A'S, HOWEVER PLANS
 INDICATE 3000A'S?
 PLEASE KNOW, THE SEC'S ARE REVISED NOW
 TO 3000A'S AND ARE OK. THIS WAS ONLY A
 NOTE.
  
 14) NOTE: PLEASE SUBMIT WIND LOAD
 CALCUALTIONS FOR SITE LIGHTING POLES AS
 REQUESTED ON PREVIOUS REVIEW. THIS COULD
 NOT BE LOCATED ON SITE LIGHTING PLANS?
 215.5
  
 15) NOTE: PLEASE SEE A PREVIOUS NOTE
 MENTIONED THE USE OF A SHUNT TRIP
 BREAKER AND THE MCB STILL BEING REQUIRED
 TO HAVE A MANUAL MEANS OF DISCONNECT
 LOCATED ON THE OUTSIDE RATED RATED FOR
 THE LOAD SERVED. 230.76,230.79 ETC.
 PLEASE SEE RESPONSE FORM DESIGN
 PROFESSIONAL MENSITONS "SHUNT TRIP"
 BREAKER REMOVED, HOWEVER PLANS STILL
 INDICATE THIS ON PANEL SCHEDULE AND
 PLANS??
 PLEASE ALSO SEEPLANS INDICATE A
 "SERVICE MAIN" LOCATED OUTSIDE HOWEVER
 THIS IS NOT INCLUDED IN RISER?
  
 16) NOTE: PLEASE INDICATE PANELS AS
 "FEEDE-THRU" AS PANEL BOARDS SHALL NOT
 CONTAIN MORE THE 42 SPACES.408.15
 PLEASE SEE ALL PANELS ON UPPER FLRS.
  
 17) NOTE: PLEASE SEE A/C UNIT IN ROOMS
 CONSIDERED TO MEET DWELLING UNIT BEDRMS
 SHALL ALSO MEET 210.12B NEC. 2002
  
 18) NOTE: PLEASE SEE NOTE #7 ON KEY
 NOTES ON RISER SHEET. PLEASE CORRELATE
 WITH NOTE #11 ON 2.01A.???
 CLARIFY?
  
 19) NOTE: PLEASE SEE KEY NOTE ON RISER
 #5, PLEASE CORRELATE WITH NOTE #2 ON
 2.01A. PLEASE SEE ONE SHOWS 175A FUSES
 AND THE OTHER 150A??
  
 20) NOTE: PLEASE SUBMIT HP RATINGS OF
 ELEVATOR MOTORS, UNABLE TO VERIFY AT
 THIS TIME.
 215.5
  
 21) NOTE: PLEASE VERIFY EQUIPEMTN BEING
 SHOWN ON 4TH FLR ELEV LOBBY. ONE AREA
 INDICATE THE EQUIPMENT IN A MECHANICAL
 CLOSET OF SOME SORT, HOWEVER PLANS ALSO
 INDICATE EQUIPMENT OUTSIDE EACH ELEVATOR
 IN OTHER TYPE OF RM/CLOSET??
  
 22) NOTE: PLEASE ALSO CORRELATE
 CIRCUITING ON PLANS FOR ELEVATOR
 EQUIPMENT, AS ONE SHOWN TO A COMPLETEY
 DIFFERENT CIRCUIT AND THE OTHER IS SHOWN
 BEING FED FROM THE "POOL PANEL"??
 215.5
  
 23) NOTE: PLEASE SEE A PANEL "EG" IS
 SHOWN ON PANEL SCHEDULES, HOWEVER NOT
 INFORMATION ON RISER FOR THIS?:
 PLEASE SEE THIS IS ALSO ON PLANS,
 HOWEVER THERE IS NOT ENOUGH INFORMATION
 FOR THIS PANEL, ATS ETC.
 215.5
  
  
  
 ** PLEASE KNOW, BASED ON THE PLANS AND
 INFORMATION SUBMITTED THERE MAY BE OTHER
 COMMENTS AS A COMPLETE REVIEW FOR CODE
 COMPLIANCE COULD NOT BE DONE AT THIS
 TIME.
 PLEASE BE SURE TO SEE ALL OF THE 2004
 FBC CHAPTER 13 FOR ELECTRICAL CHANGES.
  
 ** PLEASE KNOW, ONE SET OF PLANS ARE
 BEING RETAINED.
  
 ** PLEASE SEE ANY OTHER COMMENTS FROM
 OTHER TRADES WHICH MAY AFFECT ELECTRICAL
 PLANS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE IN CONTACTING
 THIS OFFICE.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]
 ***PLEASE KNOW, ALL THREE SETS SHALL
 BE SIGNED, DATED AND SEALED.
 PLEASE KNOW, THERE ARE ROLLS IN EACH
 PACKAGE FOR HOTELS WHICH ARE NOT SIGNED
 OR SEALED.
2006-05-11 00:00:00REVIEW IS DONE, PLANS ARE IN "F"STATUS,
 NOTES TO FOLLOW ON 5/14/06

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2006-06-27 Cont ID  
Sent By   Date 2006-06-27 Time   Rev Time  
Received By   Date 2006-06-27 Time   Sent To  
Notes
2006-06-27 00:00:00PLEASE SUBMIT FOR REVIEW DRAINAGE PLANS
 AND CALCULATIONS TO VERIFY CONSISTENCY
 WITH SFWMD ERP.
  
 ALSO REQUIRE UTLITIES REVIEW OF WATER
 AND SANITARY SEWER.
  
 STEVE SARLEY
 (561) 494-1095

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2006-06-16 Cont ID  
Sent By mcarsill Date 2006-06-16 Time 13:25 Rev Time 0.00
Received By mcarsill Date 2006-06-16 Time 11:56 Sent To  
Notes
2006-06-16 00:00:001. SUITABLE ROADS ARE TO BE PROVIDED
 DURING CONSTRUCTION FOR FIRE AND
 PARAMEDICAL EQUIPMENT.
  
 2. THE SITE PLAN ILLUSTRATING ALL NEW
 AND EXISTING FIRE HYDRANTS USED TO
 SERVICE THE NEW CONSTRUCTION AREA
 APPEARS TO BE CONFUSING. PLEASE EXPLAIN.
  
 3. SEPERATE PLANS AND PERMITS REQUIRED
 FOR FIRE ALARM AND FIRE SPRINKLER
 SYSTEMS.
  
 4. THE NEW FIRE ALARM SYSTEM SHALL BE
 MONITORED BY A UL LISTED CENTRAL STATION
 APPROVED FOR CENTRAL STATION SERVICE.
  
 5. BACKFLOW PREVENTION DEVICES ARE NOT
 SHOWN WITH TAMPER SWITCHES, CHAINS OR
 LOCKS ON THE FIRE PROTECTION DRAWINGS.
 THE ELECTRICAL DRAWINGS CONFLICT WITH
 THE FIRE PROTECTION DRAWINGS.
  
 6. THE FIRE ALARM PANEL APPEARS TO BE
 SHOWN IN TWO DIFFERENT LOCATIONS ON THE
 ELECTRICAL AND THE FIRE ALARM DRAWINGS.
 PLEASE CORRECT.
  
 7. EMERGENCY INSTRUCTIONS TO OCCUPANTS
 SHALL BE PROVIDED IN EACH GUEST ROOM.
  
 8. NO UNAUTHORIZED ELECTRIC, MECHANICAL,
 OR PLUMBING PERMITTED TO BE INSTALLED
 WITHIN THE EXIT STAIRWELLS UNLESS
 ALLOWED BY BUILDING AND FIRE CODES.
  
 9. TACTILE SIGNAGE ALTHOUGH BY OTHERS
 MUST BE NOTED ON THE PLANS TO ENSURE
 THAT THE REQUIREMENT IS MET.
  
 10. ALL SMOKE DETECTORS SHALL BE A
 MINIMUM OF AT LEAST THREE FEET FROM AIR
 CONDITIONER DIFFUSERS.
  
 11. ALL PROPOSED FIRE DAMPERS AFTER
 INSTALLATION SHALL BE TESTED TO ESNURE
 PROPER FUNCTION.
  
 12. ALL FIRE AND LIFE SAFETY SYSTEM
 SHALL BE INSPECTED, TESTED, AND APPROVED
 PRIOR TO ANY OCCUPANCY BEING ALLOWED.
  
 13. ELEVATOR WARNING SIGNS ARE REQUIRED
 AT ELEVATOR LOCATIONS.
  
 14. BUILDING ADDRESS REQUIRED.
  
 15. NO EXIT SIGNS APPEAR TO BE NEEDED ON
 THE MAID AND MECHANICAL ROOMS LOCATED
 ADJACENT TO THE EXIT STAIR DOORS. PLEASE
 SEE SECTION 7.10.8.3.1 OF NFPA 101, THE
 LIFE SAFETY CODE REGARDING THIS MATTER.
  
 16. THE COVERED ENTRY BASED ON SOME
 INFORMATION WILL BE EXPECTED TO BE FIRE
 SPRINKLER PROTECTED SINCE ALL OR SOME
 PORTIONS WILL BE COMSBUTIBLE.
  
 17. PLEASE INDICATE EMERGENCY
 INSTRUCTION LOCATIONS FOR THE COMMON
 AREAS OF THE BUILDING.
  
 18. THE INSTALLATION OF ANY SOFFITS
 SHALL NOT INTERFERE WITH THE OPERATION
 OF ANY REQUIRED FIRE SPRINKLER HEADS.
  
 19. DOORS FOR STAIRWELLS INDICATES 60
 MINUTES IN SOME LOCALES. PLEASE REVISE
 TO INDICATE 90 MINUTE DOORS EQUIPPED
 WITH SELF-CLOSING DEVICES.
  
 20. ALL REQUIRED RATED FIRE DOORS SHALL
 BE EQUIPPED WITH LABELS SPECIFYING THE
 FIRE RATING.
  
 21. PLEASE ILLUSTRATE ON THE PLANS THAT
 THE PROPOSED FIREPLACE MEETS APPLICABLE
 FIRE CODE REQUIREMENTS.
  
 22. STAIRS ARE TO BE KEPT UP WITH
 CONSTRUCTION WHILE THE BUILDING IS BEING
 CONSTRUCTED.
  
 MIKE CARSILLO, CHIEF FIRE PREVENTION
 OFFICER
 804-4709
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2006-06-14 Time   Rev Time 0.00
Received By ptjomsto Date 2006-06-14 Time 10:18 Sent To  
Notes
2006-06-14 00:00:00SUB/COPY OF APPLICATION GIVEN TO LILI
 FOR CORRECT ADDRESS

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-07-17 Cont ID  
Sent By mmclean Date 2006-07-12 Time 06:56 Rev Time 0.00
Received By mmclean Date 2006-04-06 Time 08:40 Sent To  
Notes
2006-05-15 00:00:00WAITING FOR "COMM" BD
 TO "COMM" BD#58

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2006-06-08 Cont ID  
Sent By pkrauss Date 2006-06-08 Time 10:44 Rev Time 0.00
Received By pkrauss Date 2006-06-07 Time 15:04 Sent To  
Notes
2006-06-08 00:00:00DENIED:2004 FLORIDA BUILDING CODE
  
  
 PER 2004 AMMENDMENTS TO THE FLORIDA
 BUILDING CODE SECTION 106.1.3, PLANS ARE
 TO DRAWN A MINIMUM OF 1/8" PER FOOT.
 PLANS SUBMITTED ARE DRAWN TO 3/32" PER
 FOOT.PLEASE REVISE.PLANS ARE
 OTHERWISE CODE COMPLIANT.

Review Stop P PLUMBING
Rev No 1 Status F Date 2006-06-12 Cont ID  
Sent By kstevens Date 2006-06-12 Time 15:55 Rev Time 0.00
Received By kstevens Date 2006-06-10 Time 17:55 Sent To  
Notes
2006-06-12 00:00:00DENIED
 REFERENCE: FBC-2004 PLUMBING
 FBC-2004 FUEL GAS
 FBC-2004 CHAPTER 1
 FBC-2004 CHAPTER 11
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 FIRST REVIEW THIS PERMIT NUMBER
  
 PLANS FIRST REVIEWED UNDER THE PERMIT
 NUMBER 05040948. COMMENT NUMBERS FROM
 FIRST REVIEW WILL REMAIN THE SAME. FROM
 PREVIOUS REVIEW:
  
 1. PLANS SHALL BE ROUTED TO DBPR HOTEL &
 RESTURANT DIVISION FOR REVIEW PRIOR TO
 RESUBMITTING TO THE CITY WPB FOR REVIEW.
 SUBMIT A MINIMUM OF 3 SETS OF PLANS
 STAMPED BY DBPR WITH THE TWO PAGE "WORK
 SHEETS" ATTACHED TO EACH SET. SECTION
 101.4.7.
 ***PLANS NOT STAMPED AND "WORK SHEETS"
 NOT ATTACHED. FBC-2004 SECTION 102.2.1.
  
 5. SHTS A-2.01 & A-2.02 TOILET ROOMS.
 SHOW CLEAR FLOOR SPACE FOR EACH
 ACCESSIBLE FIXTURE. SHOW TURNING AREA IN
 EACH TOILET ROOM. NOT REQUIRED IN STALL.
 SECTION 11-4.22.3
 ***RESPONSE NOTED, BUT CLEAR FLOOR SPACE
 FOR W/C'S ARE NOT SHOWN ON SHT A-2.01,
 AND NOT SHOWN FOR W/C AND LAV ROOM 138
 SHT A-2.02. - THE W/C'S OR LAV VANITY
 CAN NOT BE IN THE TURNING AREA IN THE
 TOILET ROOMS. THE TURNING AREA SHALL BE
 UNOBSTRUCTED. FBC-2004 SECTION
 11-4.22.3.
  
 6. SHTS A-2.01 & A-2.02 SUBMIT
 CALCULATIONS FOR MINIMUM FACILITIES PER
 TABLES 1103.1 & 403.1 FOR ALL COMMON
 AREAS. SHOW THE SQUARE FOOTAGE OF EACH
 COMMON AREA ON THE FLOOR PLAN.
 ***RESPONSE NOTED, BUT NO CALCULATIONS
 FOR MINIMUM FACILITIES SHOWN. NOT ALL
 COMMON USE AREAS SHOW SQUARE FOOTAGE.
 SEE ALL OCCUPANCIES FIRST FLOOR
 INCLUDING BUSINESS, KITCHEN, LIBRARY,
 E-SPACE, EMPLOYEE BREAK ROOM,
 HOUSEKEEPING LAUNDRY, GREAT ROOM,
 NETWORK ROOM, MANAGERS OFFICE,
 ADMINISTRATION, SALES OFFICE,
 REGISTRATION, SUITE SHOP, BUFFET,
 PANTRY, ETC. ALL AREAS ALL OCCUPANCY.
 FBC-2004 TABLES 1004.1.2 & 403.1.
  
 7. SHT A-2.02 SINK IN EMPLOYEE BREAK
 ROOM SHALL COMPLY WITH SECTION 11-4.24
 AND ALL SUBSECTIONS. (FORWARD APPROACH
 REQUIRED MAXIMUM 19" UNDERNEATH THE
 SINK. SINK SHALL BE CENTERED ON THE 30"
 WIDTH OF THE CLEAR FLOOR SPACE).
 ***RESPONSED NOTED, BUT THE FOLLOWING
 INFORMATION REQUIRED:
 A. 11-4.24.3 KNEE CLEARANCE
 B. 11-4.24.4 SINK DEPTH
 C. 11-4.24.6 EXPOSED PIPES & SURFACES
 D. 11-4.24.7 FAUCETS
 DETAILS 11/A-8.04 & 11A/A-8.04 ARE
 LAVATORY DETAILS. - FLOOR PLAN A-2.02
 INDICATES EMPLOYEE BREAK ROOM, WHERE AS
 DETAIL 7/A-8.04 INDICATES AN EMPLOYEE
 KITCHEN. PLEASE CORRELATE FLOOR PLAN AND
 DETAILS. FBC-2004 SECTIONS 106.1.1 &
 11-4.24.
  
 9.SHTS A-2.10 & A-2.11 SEE COMMENT #5
 CONCERNING TURNING AREA.
 ***RESPONSE NOTED, BUT THE TURNING AREA
 IS NOT SHOWN IN SOME ACCESSIBLE UNITS.
 SEE DETAIL 06/A-2.10. - W/C AND LAV
 VANITY SHOWN IN THE TURNING AREA IN
 SPECIAL STUDIO ACC. 05/A-2.10
  
 14. SHTS P-3.01, P-3.02, P-3.03 SANT.
 RISER DIAGRAMS, TUBS AND SHOWERS REQUIRE
 A TRAP. SECTION 1002.1. - RISER DIAGRAMS
 DO NOT REFLECT THE FLOOR PLANS. PLEASE
 SUBMIT RISER DIAGRAMS IN AN ISOMETRIC
 FORM THAT REFLECT THE FLOR PLAN, AND
 MEET CODE REQUIREMENTS. SHOW ALL PIPE
 SIZES, VENTS AND DFU FOR EACH RISER.
 SECTION 104.2.1.
 ***RESPONSE NOTED, BUT RISER #7 SHOWS
 REVENTS CONNECTING TO THE SANITARY STACK
 AND NOT THE VENT STACK AS REQUIRED. -
 RISER #9 SHOWS REVENT CONNECTING TO
 SANT. STACKNOT THE VENT STACK ON THE
 3RD FLOOR. - RISER #3 SINK DOES NOT
 REFLECT THE FLOOR PLAN 1ST FLOOR. (SEE
 FLOORS ABOVE). FBC-2004 106.1.1. -
 RECHECK RISER DFU'S PER TABLE 709.1.
  
 15. SUBMIT A BUILDING DRAIN SANITARY
 ISOMETRIC SHOWING ALL PIPE SIZES, DFU'S
 AS THEY ACCUMULATE IN THE SYSTEM, AND
 SHOW RISERS LOCATIONS WITH RISER
 DESIGNATION NUMBERS. SECTION 104.2.1 &
 104.3.1.1.
 ***RESPONSE NOTED, BUT PIPE SIZING FOR
 BUILDING NOT CORRECT IN SOME AREAS.
 TABLE 710.1. - W/C MISSING IN RISER
 SECTION FOR TOILET ROOMS 111, & 116.
 SECTION 106.3.5.1.3. - BUILDING SANT.
 DRAIN DOES NOT REFLECT THE FLOOR PLAN
 WHERE DRAIN EXITS THE BUILDING. SECTION
 106.1.1. - BRANCH LINE TO MOP SINK DOES
 NOT REFLECT THE FLOOR PLAN WHERE IT
 CONNECTS TO THE BUILDING DRAIN, AND THE
 FLOOR SINK, FLOOR DRAIN, & TRENCH DRAIN
 ARE NOT ON THE RISER SECTION. SECTION
 106.1.1.
  
 18. SUBMIT A WATER RISER DIAGRAM IN
 ISOMETRIC FORM FOR THE WATER
 DISTRIBUTION SYSTEM SHOWING THE LOCATION
 OF THE WATER ENTERING THE BUILDING, ALL
 PIPING NOT SHOWN ON THE RISERS, ALL PIPE
 SIZES, WATER HAMMER ARRESTORS, LOCATION
 OF WATER RISERS CONNECTING TO THE
 DISTRIBUTION LINE WITH RISER DESIGNATION
 NUMBERS ETC. SECTIONS 104.2.1 AND
 104.3.1.1.
 ***RESPONSE NOTED, BUT MANY PIPE SIZES
 ARE NOT SHOWN, WATER HAMMER ARRESTORS
 FOR WB-1, (ALL THREE), ARE NOT SHOWN,
 WATER HAMMER ARRESTORS AT THE CLOTHS
 WASHERS SHALL BE LOCATED NEAR THE
 FIXTURES IN AN "EFFECTIVE RANGE" NOT IN
 THE CEILING AS SHOWN, AND THE PIPING
 WHERE THE WATER MAIN ENTERS THE BUILDING
 AND THE MIXING VALVE, CIRCULATION PUMP,
 HOT WATER LINES, COLD WATER LINES SHALL
 REFLECT THE PIPING SCHEMATIC FOR THE
 WATER HEATERS ON SHT P-2.01. SECTIONS
 106.1.1, 604.9, PDI-WH 201 & MANUF.
 INSTALLATION INSTRUCTIONS.
  
 20. THE FOLLOWING INFORMATION IS
 REQUIRED FOR THE GAS PERMIT:
  
 A. SUBMIT AN ISOMETRIC DRAWING THAT
 CLEARLY SHOWS ALL CUT SECTIONS OF PIPE
 AND CORRESPONDING LENGTHS PER FBC-2001
 FUEL GAS CODE.
 ***RESPONSE NOTED, BUT PIPING TO
 GENERATOR NOT SHOWN ALONG WITH THE
 LENGTHS OF PIPE. FBC-2004 FUEL GAS CODE.
  
 D. BTU LOAD OF EACH APPLIANCE AND THE
 TOTAL BTU LOAD ON THE SYSTEM. REFER TO
 THE FBC-2001 FUEL GAS CODE SECS. 401.8
 THRU 402.5.2 AND TABLES 402(1) THRU
 402(34).
 ***RESPONSE NOTED, BUT NO BTU'S SHOWN
 FOR THE GENERATOR, AND NOT ADDED TO THE
 TOTAL BTU LOAD OF THE SYSTEM. FBC-2004
 FUEL GAS CODE 2004 SECS. 401.8 THRU
 402.6.1 AND TABLES 402.4(1) THRU
 402.4(33).
  
 E. SHOW THE DISTANCE FROM THE POINT OF
 DELIVERY, (METER), TO THE MOST REMOTE
 OUTLET IN THE BUILDING AND/OR SYSTEM PER
 FBC-2001 FUEL GAS CODE APPENDIX A - USE
 OF CAPACITY TABLES (A)(3).
 ***RESPONSE NOTED, BUT THE DISTANCE TO
 THE GENERATOR IS NOT SHOWN TO VERIFY
 MOST REMOTE DISTANCE IN SYSTEM. FBC-2004
 FUEL GAS CODE APPENDIX-A USE OF CAPACITY
 TABLES A.3.1(4).
  
 H. SUBMIT MANUFACTURE SHEETS FOR ALL GAS
 EQUIPMENT TO VERIFY COMPLIANCE WITH
 STANDARDS NFPA 54, NFPA 58, AND THE
 FBC-2001 FUEL GAS CODE SEC 402.2.
 ***NO RESPONSE, NO MANUF. SHEETS FOUND.
  
 **************NEW COMMENTS**************
  
 1B. SHT A-2.11 INDICATE HOW SECTION
 11-9.1.4 IS BEING COMPLIED WITH WHEN NO
 ACCESSIBLE UNITS FOR 1 BEDROOM WITH A
 CONFERENCE ROOM ARE AVAILABLE.
  
 2B. SHT A-2.01 SHOWS A HEAT N GLO GAS
 FIREPLACE THAT IS NOT SHOWN ON THE GAS
 RISER DIAGRAM. PLEASE CLARIFY. SECTION
 106.1.1.
  
 3B. SHT A-201 IN THE PANTRY A SINK TO
 THE LEFT OF THE THREE COMPARTMENT SINK
 IS NOT IDENTIFIED ON THE FOOD SERVICE
 EQUIPMENT SCHEDULE. - HAND SINK #9
 DESIGNATION NUMBER NOT SHOWN AT SINK.
 PLEASE CLARIFY. SECTION 106.1.1.
  
 4B. ALL ARCHITECTURAL SHEETS.
 CERTIFICATE OF AUTHROIZATION, (FIRM
 LICENSE), IS INDICATED AS "NULL & VOID"
 PER DBPR CERTIFICATION WEBSITE.
  
 5B. PLUMBING & MECHANICAL SHEETS,
 ENGINEERS SHALL LEGIBLY INDICATE THEIR
 NAME AND LICENSE NUMBER, AS WELL AS, THE
 NAME, ADDRESS, AND CERTIFICATE OF
 AUTHROIZATION NUMBER OF THE ENGINEERING
 BUSINESS ON EACH SHEET. FAC
 61G15-23.002(2) AND FS 471.025.
  
 6B. SHT P-5.01 MECHANICAL & LAUNDRY ROOM
 WATER. THE WATER LINES FOR THE WATER
 HEATERS, CIRCULATION PUMP, MIXING VALVE,
 AND WATER PIPING AS IT ENTERS THE
 BUILDING SHALL REFLECT THE PIPING SHOWN
 ON SHT P-2.01 PIPING SCHEMATIC AT WATER
 HEATERS. PLEASE CORRELATE PIPING.
 SECTION 106.1.1.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6721
 E-MAIL [email protected]
  
  
  
  
  

Review Stop Z ZONING
Rev No 1 Status F Date 2006-07-12 Cont ID  
Sent By eschneid Date 2006-07-12 Time 13:54 Rev Time 0.00
Received By eschneid Date 2006-07-12 Time 13:54 Sent To  
Notes
2006-07-12 00:00:00PER SHIRLEY GRAHAM -
  
 NO LANDSCAPE PLANS INCLUDED.