Plan Review Details - Permit 06040092
Plan Review Stops For Permit 06040092
Review Stop G GAS REVIEW
Rev No 2 Status P Date 2006-07-19 Cont ID  
Sent By mperson Date 2006-07-19 Time 11:32 Rev Time 0.33
Received By mperson Date 2006-07-19 Time 11:32 Sent To PC
Notes
2006-07-19 00:00:00NOTE: RESUBMITTAL MISSING PERMIT
 APPLICATION, CONTRACTOR INFORMED
 DUPLICATE REQUIRED BEFORE PERMIT IS
 ISSUED.

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2006-04-07 Cont ID  
Sent By mperson Date 2006-04-07 Time 08:08 Rev Time 0.45
Received By mperson Date 2006-04-07 Time 08:08 Sent To PC
Notes
2006-04-07 00:00:00******DENIED******
 REFERENCE: FBC-2004 FUEL GAS
  
 PLEASE ADJUST YOUR NOTES, DETAILS, OR
 SUBMITTALS TO REFLECT THE FOLLOWING
 INFORMTION REQUIRED FOR PLAN REVIEW.
  
 1. SUBMIT AN ISOMETRIC DRAWING THAT
 CLEARLY SHOWS ALL CUT SECTIONS OF PIPE
 AND CORRESPONDING LENGTHS PER FBC-2004
 FUEL GAS.
 2. SHOW TYPE OF PIPING MATERIAL BEING
 INSTALLED, ALL PIPE SIZES, (AND THE EDH
 NUMBER OF CORRUGATED STAINLESS STEEL
 TUBING FOR EACH PIPE SIZE BEING USED.
 3. TYPE OF GAS, (LP OR NATURAL)
 4. BTU LOAD OF EACH APPLIANCE AND THE
 TOTAL BTU LOAD ON THE SYSTEM. REFER TO
 THE FBC-2004 FUEL GAS CODE SECS. 401.8
 THRU 402.6.1 AND TABLES 402(1) THRU
 402(33).
 5. SHOW THE DISTANCE FROM THE POINT OF
 DELIVERY, (METER), TO THE MOST REMOTE
 OUTLET IN THE BUILDING AND/OR SYSTEM PER
 FBC-2004 FUEL GAS CODE APPENDIX A - USE
 OF CAPACITY TABLES A.3.1(4).
 6. SUBMIT CALCULATIONS FOR COMBUSTION
 AIR (IF APPLICABLE) PER FBC-2004 FUEL
 GAS CODE SECTION 304.
 7. INDICATE THE DELIVERY PRESSURE (PSI)
 PER FBC-2004 FUEL GAS CODE SEC. 402.2.
 NATURAL GAS SPECIFY .5 PSI OR 2 PSI.
 8. SUBMIT A DETAIL SHOWING THE TYPE,
 LOCATION, SIZE AND TERMINATION OF THE
 GAS VENTS PER FBC-2004 FUEL GAS CODE
 SECS. 502 THRU 506.
 9. SUBMIT MANUFACTURE SHEETS FOR ALL GAS
 EQUIPMENT TO VERIFY COMPLIANCE WITH
 STANDARDS NFPA 54, NFPA 58, AND THE
 FBC-2004 FUEL GAS CODE SEC 402.2
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K/STEVENS
 (561) 805-6721
  
  
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-07-14 Cont ID  
Sent By adarroug Date 2006-07-14 Time 16:06 Rev Time 0.00
Received By adarroug Date 2006-07-14 Time 16:06 Sent To G
Notes
2006-07-14 00:00:00TO "P" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-07-14 Cont ID  
Sent By adarroug Date 2006-07-07 Time 16:05 Rev Time 0.00
Received By adarroug Date 2006-04-06 Time 15:45 Sent To  
Notes
2006-04-06 00:00:00TO "G" BOX


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved