Plan Review Details - Permit 06040086
Plan Review Stops For Permit 06040086
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2006-07-27 Cont ID  
Sent By lmartine Date 2006-07-27 Time 14:05 Rev Time 0.00
Received By lmartine Date 2006-07-27 Time 14:05 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-04-26 Cont ID  
Sent By lmartine Date 2006-04-26 Time 17:15 Rev Time 0.00
Received By lmartine Date 2006-04-26 Time 17:15 Sent To  
Notes
2006-04-26 00:00:00 
  
 PROVIDE WALL SECTION DETAILS.
  
  
  
  
  
  
  
  
 L.MARTINEZ
 805-6710

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2007-03-13 Cont ID  
Sent By btrobaug Date 2007-03-13 Time 07:34 Rev Time 0.50
Received By btrobaug Date 2007-03-13 Time 06:37 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-12-19 Cont ID  
Sent By jleahy Date 2006-12-19 Time 09:51 Rev Time 0.45
Received By jleahy Date 2006-12-19 Time 09:51 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status N Date 2006-04-10 Cont ID  
Sent By btrobaug Date 2006-04-10 Time 17:28 Rev Time 0.33
Received By btrobaug Date 2006-04-10 Time 17:23 Sent To  
Notes
2006-04-10 00:00:00 
 AN ELECTRICAL PERMIT IS REQUIRED FOR THE
 WATER HEATER INSTALLATIION.
 THE ELECTRICAL CONTRACTOR MUST SUBMIT
 PLANS WITH A LOAD CALCULATION OF THE
 PANEL SERVING THE HEATER, PANEL
 DESIGNATION, CIRCUIT NUMBERS, CONDUCTOR
 AND OCP SIZES.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status N Date 2006-04-19 Cont ID  
Sent By nmccray Date 2006-04-19 Time 10:46 Rev Time 0.00
Received By nmccray Date 2006-04-19 Time 10:37 Sent To  
Notes
2006-04-19 00:00:00NO CODE REFERENCE FOR BATHROOM OR
 RESTROOM RENOVATION.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-02-22 Cont ID  
Sent By adarroug Date 2007-02-22 Time 13:23 Rev Time 0.00
Received By adarroug Date 2007-02-22 Time 13:23 Sent To E
Notes
2007-02-22 13:25:16TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-07-07 Cont ID  
Sent By adarroug Date 2006-07-07 Time 10:04 Rev Time 0.00
Received By adarroug Date 2006-07-07 Time 10:04 Sent To  
Notes
2006-07-07 00:00:00WAITING FOR "BOB"
 TO "BOB"#1

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-07-07 Cont ID  
Sent By adarroug Date 2006-04-26 Time 09:53 Rev Time 0.00
Received By adarroug Date 2006-04-06 Time 09:39 Sent To  
Notes
2006-04-19 00:00:004/19/06-TO LMARTINEZ DESK FOR BLDG REV
2006-04-06 00:00:00TO "BOB"#4

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2006-04-11 Cont ID  
Sent By tgordon Date 2006-04-11 Time 09:53 Rev Time 0.20
Received By tgordon Date 2006-04-11 Time 09:53 Sent To  
Notes
2006-04-11 00:00:00NO MECHANICAL PLANS SUBMITTED, AND NO
 MECHANICAL PERMIT NUMBER APPLIED FOR AT
 THIS TIME.

Review Stop P PLUMBING
Rev No 3 Status P Date 2006-10-18 Cont ID  
Sent By jleech Date 2006-10-18 Time 14:58 Rev Time 0.00
Received By jleech Date 2006-10-18 Time 14:58 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2006-07-15 Cont ID  
Sent By jleech Date 2006-07-15 Time 14:10 Rev Time 0.00
Received By jleech Date 2006-07-15 Time 14:10 Sent To  
Notes
2006-07-15 00:00:00DENIED;
 1. ONLY ONE SET OF "P" PLANS SUBMITED,
 TWO SETS REQUIRED.
 2. CHECK WITH WATER DEPARTMENT FOR
 LOCATION OF BACKFLOW PREVENTORS. THE
 BACKFLOWS SHOULD BE AS CLOSE TO THE
 WATER METER AS POSSIBLE BUT ON THE
 BUILDING PROPERTY.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop P PLUMBING
Rev No 1 Status F Date 2006-04-13 Cont ID  
Sent By jleech Date 2006-04-13 Time 13:52 Rev Time 0.00
Received By jleech Date 2006-04-13 Time 13:52 Sent To  
Notes
2006-04-13 00:00:00DENIED;
 1.BATHROOMS ARE NOT HANDICAP ACCESSIBLE.
 SHOW 5' TURNING RADIUS ON PLANS.
 SHOW BATHROOM MESSUREMENTS.
 SHOW ELEVATIONS OF H/C FIXTURES AS
 SHOWN IN FBC-2004 CHAPTER 11, FIG'S
 27,28,29,31, AND 32. TOILET,
 LAVATORY, DRINKING FOUNTAIN AND GRAB
 BARS.
 HANDICAP DRINKING FOUINTAIN IS
 REQUIRED TO HAVE A CUP DISPENSOR FOR
 PEOPLE WITH BAD BACKS
 PER SEC 11-4.1.2(10).
 2.TRAP PRIMERS SHOWN ON PAGE P-3. NO
 FLOOR DRAINS SHOWN ON RISER DIAGRAM.
 SHOW FOOR DRAINS OR DELETE DIAGRAM.
 3.FLAT PIPE DRAWING DOES MATCH RISER
 DIAGRAM. FLAT DRAWING IS CORRECT PLEASE
 CHANGE RISER DIAGRAM.
 4.WATER RISER. IF WATER HAMMER ARRESTORS
 ARE USED, SPEC OUT TYPE AND MANUFACTOR,
 AND THEY SHOULD BE INSTALLCLOSE TO
 THE FIXTURE PER MANUFACTURE'S
 RECOMENDATIONS. SEC.604.9.
 5.SHUTOFF VALVES REQUIRED ON ALL THREE
 WATER SERVICES PER SEC. 606.1(2).
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695