| Plan Review Stops For Permit 06040067 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2006-10-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-10-26 |
Time |
08:09 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2006-10-26 |
Time |
08:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2006-09-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-10-17 |
Time |
17:55 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2006-09-19 |
Time |
12:41 |
Sent To |
|
|
| Notes |
| 2006-09-19 00:00:00 | ADD: 700 S. ROSEMARY AV #130 | | | CONT:PLAN REVIEW | | | TEL: (561)213-6975 STEVE | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 3RD REVIEW | | | ACTION: DENIED | | | | | | 1) FL S S 713.13 | | | NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT BEFORE A | | | PERMIT WILL BE ISSUED. NOTE: 713.13(2) | | | IF THE WORK DESCRIBED IN THE NOTICE OF | | | COMMENCEMENT IS NOT ACTUALLY COMMENCED | | | WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. | | | | | | 2) COMPLIED. | | | | | | 3) SECOND REQUEST, THE ARCHITECT PLACED | | | HIS OWN PROFESSIONAL LICENSE NUMBER AS | | | THE FIRMS LICENSE NUMBER. | | | ZAG ZAMPERELLI ARCHITECTURAL GROUP, | | | MISSING THEIR CERTIFICATE OF | | | AUTHORIZATION.481.219 F.S.CERTIFICATE | | | OF AUTHORIZATION.THE TITLE BLOCK FOR | | | ANY SHEET BEARING THE NAME OF AN | | | ARCHITECT PRACTICING UNDER A FICTITIOUS | | | NAME, A CORPORATION, OR A PARTNERSHIP, | | | OFFERING ARCHITECTURAL SERVICES, SHALL | | | INCLUDE THE CERTIFICATE OF AUTHORIZATION | | | NUMBER.ADD THE NUMBER TO EACH SHEET. | | | THIS MAY BE ADDED BY HAND. | | | | | | | | | 4) COMPLIED. | | | | | | 5) COMPLIED. | | | | | | 6) COMPLIED. | | | | | | 7A) COMPLIED | | | | | | 7B) COMPLIED | | | | | | 7C)COMPLIED. | | | 7D) COMPLIED | | | | | | 7E) COMPLIED. | | | | | | 8) NOTE: THE NEW PLANS WILL NEED | | | TO BE RESTAMPED FOR APPROVAL BY CITY | | | PLACE BEFORE SUBMITTAL TO CITY FOR | | | REVIEW. | | | | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-07-19 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-07-19 |
Time |
12:48 |
Rev Time |
1.11 |
| Received By |
jwitmer |
Date |
2006-07-19 |
Time |
12:09 |
Sent To |
|
|
| Notes |
| 2006-07-19 00:00:00 | PERMIT: 06040067 | | | ADD: 700 S. ROSEMARY AV #130 | | | CONT:PLAN REVIEW | | | TEL: (561)213-6975 STEVE | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) FL S S 713.13 | | | NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT BEFORE A | | | PERMIT WILL BE ISSUED. NOTE: 713.13(2) | | | IF THE WORK DESCRIBED IN THE NOTICE OF | | | COMMENCEMENT IS NOT ACTUALLY COMMENCED | | | WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. | | | | | | 2) COMPLIED. | | | | | | 3) SECOND REQUEST, THE ARCHITECT PLACED | | | HIS OWN PROFESSIONAL LICENSE NUMBER AS | | | THE FIRMS LICENSE NUMBER. | | | ZAG ZAMPERELLI ARCHITECTURAL GROUP, | | | MISSING THEIR CERTIFICATE OF | | | AUTHORIZATION.481.219 F.S.CERTIFICATE | | | OF AUTHORIZATION.THE TITLE BLOCK FOR | | | ANY SHEET BEARING THE NAME OF AN | | | ARCHITECT PRACTICING UNDER A FICTITIOUS | | | NAME, A CORPORATION, OR A PARTNERSHIP, | | | OFFERING ARCHITECTURAL SERVICES, SHALL | | | INCLUDE THE CERTIFICATE OF AUTHORIZATION | | | NUMBER.ADD THE NUMBER TO EACH SHEET. | | | THIS MAY BE ADDED BY HAND. | | | | | | | | | 4) COMPLIED. | | | | | | 5) COMPLIED. | | | | | | 6) COMPLIED. | | | | | | 7A) COMPLIED | | | | | | 7B) COMPLIED | | | | | | 7C) 2ND REQUEST BUILDING TYPE, NOTE TAKE | | | THE SIZE OF THE BUILDING INTO ACCOUNT, | | | ALSO NOTE THE PARKING GARAGE IS PART OF | | | THE SAME BUILDING!!!! | | | | | | 7D) COMPLIED | | | | | | 7E) COMPLIED. | | | | | | 8) NEW COMMENT, THE NEW PLANS WILL NEED | | | TO BE RESTAMPED FOR APPROVAL BY CITY | | | PLACE BEFORE SUBMITTAL TO CITY FOR | | | REVIEW. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-05-09 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-05-09 |
Time |
12:28 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2006-05-09 |
Time |
12:24 |
Sent To |
|
|
| Notes |
| 2006-05-09 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 06040067 | | | ADD: 700 S. ROSEMARY AV #130 | | | CONT:PLAN REVIEW | | | TEL: (561)213-6975 STEVE | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) FL S S 713.13 | | | NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT BEFORE A | | | PERMIT WILL BE ISSUED. NOTE: 713.13(2) | | | IF THE WORK DESCRIBED IN THE NOTICE OF | | | COMMENCEMENT IS NOT ACTUALLY COMMENCED | | | WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. | | | | | | 2) A-0 BUILDING DEPARTMENT DATA FOR | | | HANDICAPPED CODE, THE ONLY CODE ADOPTED | | | BY FLORIDA IS THE FLORIDA ACCESSIBILITY | | | CODE, CHAPTER 11 OF 2004 FBC. DELETE THE | | | OTHER REFRENCES, PLEASE. | | | | | | 3) ZAG ZAMPERELLI ARCHITECTURAL GROUP, | | | MISSING THEIR CERTIFICATE OF | | | AUTHORIZATION.481.219 F.S.CERTIFICATE | | | OF AUTHORIZATION.THE TITLE BLOCK FOR | | | ANY SHEET BEARING THE NAME OF AN | | | ARCHITECT PRACTICING UNDER A FICTITIOUS | | | NAME, A CORPORATION, OR A PARTNERSHIP, | | | OFFERING ARCHITECTURAL SERVICES, SHALL | | | INCLUDE THE CERTIFICATE OF AUTHORIZATION | | | NUMBER.ADD THE NUMBER TO EACH SHEET. | | | THIS MAY BE ADDED BY HAND. | | | | | | 4) PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 5) 1609.1.4 PROTECTION OF OPENINGS. | | | IN WIND-BORNE DEBRIS REGIONS, EXTERIOR | | | GLAZING THAT RECEIVES POSITIVE PRESSURE | | | IN THE LOWER 60 FEET (18.3 M) IN | | | BUILDINGS SHALL BE ASSUMED TO BE | | | OPENINGS AND THE BALANCE OF GLAZED | | | OPENINGS IN THE REST OF THE BUILDING | | | SHALL BE ASSUMED TO BE ZERO UNLESS SUCH | | | GLAZING THAT RECEIVES POSITIVE PRESSURE | | | IS IMPACT RESISTANT OR PROTECTED WITH AN | | | IMPACT RESISTANT COVERING MEETING THE | | | REQUIREMENTS OF SSTD 12, ASTM E 1886 AND | | | ASTM E 1996, OR MIAMI-DADE TAS 201, 202 | | | AND 203 REFERENCED THEREIN AS FOLLOWS: | | | 1.GLAZED OPENINGS LOCATED WITHIN 30 | | | FEET (9.1 M) OF GRADE SHALL MEET THE | | | REQUIREMENTS OF THE LARGE MISSILE TEST. | | | 2.GLAZED OPENINGS LOCATED MORE THAN | | | 30 FEET (9.1 M) ABOVE GRADE SHALL MEET | | | THE PROVISIONS OF THE SMALL MISSILE | | | TEST. | | | | | | 6) FL BLD CODE 1609.1.5: COMPONENTS & | | | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- | | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | | TESTING REPORTS,MISSING REPORTS ARE AS | | | FOLLOWS: | | | A) STOREFRONT WINDOWS | | | B) MULLIONS | | | C) STOREFRONT DOORS | | | | | | 7) 110.2* W. P. B. ADMINISTRATIVE CODE, | | | INFORMATION THAT IS REQUIRED FOR RECORD | | | KEEPING & FOR CERTIFICATE OF OCCUPANCY: | | | A) THE EDITION OFTHE CODE UNDER WHICH | | | THE PERMIT WAS ISSUED. | | | B) THE USE AND OCCUPANCY, IN ACCORDANCE | | | WITH THE PROVISIONS OF CHAPTER 3. | | | C) THE TYPE OF CONSTRUCTION AS DEFINED | | | IN CHAPTER 6, TABLE 601. | | | D) THE DESIGN OCCUPANT LOAD, SEE 1004. | | | E) IF AN AUTOMATIC SPRINKLER SYSTEM IS | | | PROVIDED, WHETHER THE SPRINKLER SYSTEM | | | IS REQUIRED. | | | F) ANY SPECIAL STIPULATIONS & CONDITIONS | | | OF THE BUILDING PERMIT. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
P |
Date |
2006-12-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-12-26 |
Time |
15:40 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-12-26 |
Time |
14:56 |
Sent To |
PC |
|
| Notes |
| 2006-12-26 15:42:35 | PLANS REDLINED: | | | | | | ONLY FIXTURES CONTAINING THE "NL" DESIGNATIONS ARE TO | | | REMAIN "ON" AS NIGHT LIGHTS, NOT ALL FIXTURES ON THAT | | | CIRCUIT. | | | PLEASE ALSO SEE NOTES HIGHLIGHTED AS THE PER CIRCUITING | | | OF EM / EXT LTS. 700.12E. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
F |
Date |
2006-12-06 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-12-06 |
Time |
20:36 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-12-06 |
Time |
20:25 |
Sent To |
PC |
|
| Notes |
| 2006-12-06 20:37:07 | *** UNSAT *** | | | | | | 1) NOTE:PLEASE UPDATE PLANS AND CORRELATE REVISIONS | | | ON PLANS WITH THE TITLE BLOCKS. PLEASE SEE PLANS ARE | | | BEING SUBMITTED WITH REV #4, WHERE PLANS ON FILE | | | ALREADY CONTAIN REVISIONS 5 AND 6. PLEASE SEE THAT ALL | | | CORRELATE. | | | FBC 106.1.2, 106.1.3.5.1 | | | | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2006-11-02 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-11-02 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-11-02 |
Time |
13:37 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2006-10-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-10-15 |
Time |
15:40 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-10-15 |
Time |
17:57 |
Sent To |
|
|
| Notes |
| 2006-10-15 15:40:27 | *** UNSAT4THREVIEW ***** | | | | | | ** PLEASE SEE SOME ITEMS FROM PREVIOUS REVIEW ARE STILL | | | IN NEED OF COMPPLIANCE. | | | | | | | | | 1) NOTE: PLEASE SEE AS STATED IN PREVIOUS REVIEWS, ALL | | | SEPARATE SPACES REQUIRE OVER-RIDE DEVICE(S) . | | | PLEASE SEE PREVIOUS NOTES FOR SCHEDULING. | | | PLEASE SEE PREVIOUS NOTES FOR MAX WATTAGE PERMITTED. | | | BASED ON THE WATTAGE ON FIXTURES ON PLANS, THIS EXCEEDS | | | THE "PROPOSED WATTAGE" WHICH IS STATED ON PLANS. PLEASE | | | PROVIDE A COMPLETE SUMMARY OF AREAS FOR LIGHTING POWER | | | DENSITIES AS ALLOWED PER CODE. PLEASE SEE TABLES AS | | | PERVIOUSLY NOTED. | | | PLEASE SEE SOME FIXTURES AND EM LTS ARE SHOWN BEING | | | CIRCUITED THROUGH TIMER WHICH IS OK, HOWEVER THESE ARE | | | NOTEDBEING WIRED AHEAD OF CONTROLS, HOWEVER SHOULD BE | | | SHOWN ON LIGHTING DETAIL SO THIS ALLEAVIATES ANY | | | CONFUSION. THIS ITEM IS NOT REQUIRED , HOWEVER | | | RECOMMENDED. IT IS CLEAR TO THE DESIGNER AND REVIEWER | | | OF THE INTENT, HOWEVER THE TIME CONTROL PANEL DOES NOT | | | INDICATE THIS AND HOW THIS WILL TAKE PLACE. | | | PLEASE ALSO CORRELATE WITHTHE WATTAGE BEING SHOWN ON | | | PANEL SCHEDULES, AS THIS WATTAGE EXCEED ACTUAL SHOWN | | | AND PROPOSED DESIGN WATTAGE. | | | PLEASE SEE 13-415.1.ABC.1.1, .1.2 AND .1.3. | | | PLEASE SEE 13-415..ABC.1. , PLEASE SEE WHERE TRADES | | | OFFS ARE NOT PERMITTED UNDER CERTAINS CIRCUMSTANCES. | | | PLEASE SEE TABLES 415.2.C.1, 415.2.B.1 | | | IT APPERS A WATTAGEAS SHOWN IS COMING FROM THE SPACE | | | BY SPACE TABLES AT 2.1, HOWEVER PLEASE SEE FBCAS | | | NOTED. | | | | | | | | | 2) NOTE: PLEASE SEE PREVIOUS REVIEWS WITH RESPECT | | | RELEVANT CODES NOT CURRENT. PLEASE SEE PREVIOUS NOTES | | | WHICH ALSO MENTIONED "A" SHEET(S). STILL SHOW 1999 | | | NEC. | | | | | | | | | 3) NOTE: PLEASE SEE FEES FOR FS 553.80(2)(B) HAS NOW | | | BEEN ASSESSED AND MUST BE PAID BEFORE PLANS ARE | | | RESUBMITTED ON NEXT REVIEW. | | | THIS FEE IS $3132.00 | | | PLANS WILL RETAINED BY THIS OFFICE FOR POSSIBLE REVIEW | | | FROM THE FLORIDA BOARD OF PROFESSIONAL ENGINEERS. | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2006-08-25 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-08-25 |
Time |
17:47 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-08-25 |
Time |
11:27 |
Sent To |
|
|
| Notes |
| 2006-08-25 00:00:00 | ******* UNSAT 3RD REVIEW ***** | | | | | | ** PLEASE SEE SOME COMMENTS FROM | | | PREVIOUS REVIEWS STILL NEED TO BE | | | ADDRESSED. | | | PLEASE SEE NOTES BELOW ARE TAKEN | | | DIRECTLY FROM PREVIOUS REVIEW. | | | | | | | | | | | | 1) NOTE:NO. SEE PREVIOUS NOTE. | | | | | | ** PREVIOUS REVIEW NOTE 2ND REVIEW ** | | | NO, PLEASE SEE THERE ARE | | | PLACES ON PLANS WHICH STILL REFLECT | | | OLDER CODES. PLEASE SEE "A" SHEETS, AND | | | E-SHEETS. PLEASE SEE NOW THE CHANGES | | | MADE ON E-3 NOW CONTAIN BOTH THE | | | PREVIOUS AND CURRENT ELECTRICAL CODE. | | | PLEASE SEE E-4 WHICH STILL REFLECTS | | | SBCCI, SFBC, 1997 LS 101 ETC. | | | | | | ** PREVIOUS REVIEW 1ST REVIEW NOTE** | | | PLEASE ADJUST AND REFLECT ALL | | | CURRENT CODES IN AFFECT. | | | PLEASE SEE WE ARE UNDER THE 2002 | | | NFPA-70( NEC), 2003 NFPA-101, 2002 | | | NFPA-72. | | | PLEASE KNOW THESE CODES AT A MINIMUM | | | SHALL BE REFERENCED ON ARCHITECTURAL AND | | | ELECTRICAL/ FIRE PLANS. | | | PLEASE SEE PLANS REFLECT 1999 NEC, 1997 | | | SBC, AND THE SBCCI ETC. | | | PLEASE SE COMMENTS FROM OTHER TRADES | | | WITH RESPECT TO CODES. (BUILDING). | | | | | | 2) NOTE: NO. IT IS BEING NOTED THAT ONE | | | FIRM LICENSE NUMBER IS NOW BEING SHOWN, | | | HOWEVERPLEASE KNOW WE HAVE BEEN IN | | | CONTACT WITH THE STATE'S LEGAL COUNSEL | | | TO THE BOARD OF ARCHITECTS AS THE FIRM | | | LICENSE NUMBER PROVIDED IS LISTED ON THE | | | STATE'S WEBSITE FOR V.Z.AARCHITECT'S | | | P.A. AND THERE IS NO LISTING FOR | | | "ZAMPARELLI ARCHITECTURAL GROUP" AKA | | | "ZAG". | | | PLEASE KNOW THIS HAS BEEN CONFIRMED WITH | | | DWIGHT CHASTANE FROM THE FIRM WHICH | | | REPRESENTSTHE STATE BOARD OF | | | ARCHITECTURE'S LEGAL COUNSEL. IT IS | | | MENTIONED THAT BOTH COMPANIES AS LISTED | | | ON TITLE BLOCKSWHICH ARE REGIESTERED | | | WITH THE STATEWOULD EACH REQUIRE A | | | CERTIFICATE OF AUTHORIZATION NUMBER. | | | | | | ** PREVIOUS REVIEW NOTE 2ND REVIEW** | | | NO, PLEASE SEE ONLY THE | | | PRINTED NAME AND LICENSE # OF THE | | | ARCHITECT WAS ADDED. PLEASE SEE THE FIRM | | | TITLE BLOCK IS STILL MISSING THE | | | REQUIRED FIRM LICENSE NUMBER WHICH IS | | | ALSO KNOWN AS THE CERTIFICATE OF | | | AUTHORIZATION NUMBER. | | | FS 481.219, FAC 61G1-16.004 | | | | | | ** PREVIOUS REVIEW NOTE 1ST REVIEW ** | | | PLEASE SEE MISSING INFORMATION | | | ON TITLE BLOCKS FOR ARCHITECT AND | | | ARCHITECTURAL FIRM. PLEASE SEE FLORIDA | | | ADMINISTRATIVE CODE 61G1-16.004 AND | | | FLORIDA STATUES 481.219. | | | MISSING THE PRINTED NAME AND LICENSE # | | | OF THE ARCHITECT, MISSING THE FIRM | | | LICENSE # FOR THE ARCHITECTURAL FIRM. | | | | | | 3) NOTE: OK. | | | | | | 4) NOTE: OK. | | | | | | 5) NOTE: OK. | | | | | | 6) NOTE: OK. | | | | | | 7) NOTE: OK | | | | | | ******** NEW NOTES 2ND REVIEW ****** | | | | | | 8) NOTE:NO, PLEASE SEE CONDUCTORS | | | STILL DO NOT CORRELATE. | | | | | | ** PREVIOUS REVIEW NOTE 2ND REVIEW** | | | PLEASE SEE RISER AND PANEL "A" | | | AS THE OCP FOR THE AHU WAS ADJUSTED AND | | | INCREASED TO 30A?S. PLEASE SEE THAT THE | | | CONDUCTOR SIZE WAS CHANGED ON THE PANEL | | | SCHEDULE, HOWEVER PLEASE SEE RISER | | | | | | 9) NOTE: NO, PLEASE SEE CONTROLS FOR | | | SEPARATE SPACES IS NOT BEING SHOWN. | | | PLEASE SEE LOCATIONS AT INGRESS/EGRESS | | | FOR OVER-RIDES ARE NOT SHOWN ON PLANS AT | | | LOCATION WHERE OCCUPANT ENTERS AND EXITS | | | AND CAN VISUALLY SEE LIGHTING BEING | | | CONTROLLED BY OVER RIDES. | | | PLEASE SEE LIGHTING POWER DENSITIES ON | | | PLANS/SEPARATLY COULD NOT BE LOCATED. | | | PLEASE SEE EACH DEVICE SHOULD BE LISTED | | | AND SHOWN ON SYMBOL LEGEND FOR TYPE AND | | | AMOUNT OF OVER RIDES TIME. | | | | | | ** PREVIOUS REVIEW NOTE 2ND REVIEW** | | | PLEASE SEE A LIGHTING CONTROL | | | PANEL IS BEING SHOWN TO MEET FBC CHAPTER | | | 13-415.1.ABC.1.1, .1.2, .1.3, HOWEVER | | | PLEASE PROVIDE THE OVER-RIDE DEVICES AT | | | THIS TIME AND LOCATED IN THE SPACES AS | | | REQUIRED. | | | PLEASE INDICATE THE DEVICE AND KNOW, | | | WHEN USING A TIMED OVER-RIDE (4HRS MAX) | | | AND OCCUPANCY SENSOR TYPE DEVICE (30MINS | | | MAX). PLEASE SEE AREAS WITH SEPARATE | | | SPACES. | | | PLEASE ALSO SEE 13-415.1.AB.1, AND | | | 13-415.2.ABC.1 FOR MAX LIGHTING | | | DENSITIES PERMITTED. | | | PLEASE SEE BOTH TABLES AND INDICATE. | | | PLEASE PROVIDE ALL CONTROLLED CIRCUITING | | | ON TIME/PANEL SCHEDULE. PLEASE ALSO | | | PROVIDE THE SCHEDULING TIMES. | | | | | | ** NEW NOTE ** | | | 10) NOTE: PLEASE SEE FS 553.80(2)(B) | | | WITH RESPECT TO REPEAT COMMENTS. PLEASE | | | KNOW AS PLANS ONLY CMAE IN FOR "PLAN | | | REVIEW" FOR THE FIRST REVIEW, PLEASE | | | KNOW THE FEE IS NOT ASSESSED AT THIS | | | TIME. PLEASE BE SURE ALL COMMENTS ARE | | | ADDRESSED AND IF THERE ARE ANY | | | QUESTIONS, ONCE AGAIN PLEASE DO NOT | | | HESITATE IN CONTACTING THIS OFFICE. | | | ONE SET OF PLANS ARE BEING RETAINED BY | | | THIS OFFICE. | | | | | | | | | ** WHEN RESUBMITTING PLANS, PLEASE | | | COMPLETELY REMOVE ALL OLD/VOIDED SHEETS | | | AND ONLY INSERT NEW REVISED SHEETS INTO | | | TWO COMPLETE SETS FOR REVIEW AND | | | STAMPING. | | | | | | ** PLEASE SEE ANY COMMENTS FROM OTHER | | | TRADES WHICH MAY AFFECT ELECTRICAL | | | PLANS. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | DPALMER@WPB. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-06-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-06-27 |
Time |
09:30 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-06-27 |
Time |
07:25 |
Sent To |
|
|
| Notes |
| 2006-06-27 00:00:00 | **** PLANS REMOVED FROMHOLD,**** | | | | | | PLEASE SEE PERMIT FEES WERE NOT PAID AND | | | REVIEWS ARE ON HOLD. | | | CALLED PERMIT PROVIDERS, TO PAY W/IN | | | 24HRS. SPOKE TO STEVE. | | | | | | NO REVIEWS WILL BE DONE. | | | ******* UNSAT2ND REVIEW ***** | | | | | | | | | | | | ** PLEASE SEE PLANS ARE NOW SUBMITTED | | | FOR PERMIT. PLEASE SEE SOME COMMENTS | | | FROM PREVIOUS REVIEW AND SOME NEW | | | COMMENTS. | | | | | | 1) NOTE:NO, PLEASE SEE THERE ARE | | | PLACES ON PLANS WHICH STILL REFLECT | | | OLDER CODES. PLEASE SEE "A" SHEETS, AND | | | E-SHEETS. PLEASE SEE NOW THE CHANGES | | | MADE ON E-3 NOW CONTAIN BOTH THE | | | PREVIOUS AND CURRENT ELECTRICAL CODE. | | | PLEASE SEE E-4 WHICH STILL REFLECTS | | | SBCCI, SFBC, 1997 LS 101 ETC. | | | | | | ** PREVIOUS REVIEW NOTE** | | | PLEASE ADJUST AND REFLECT ALL | | | CURRENT CODES IN AFFECT. | | | PLEASE SEE WE ARE UNDER THE 2002 | | | NFPA-70( NEC), 2003 NFPA-101, 2002 | | | NFPA-72. | | | PLEASE KNOW THESE CODES AT A MINIMUM | | | SHALL BE REFERENCED ON ARCHITECTURAL AND | | | ELECTRICAL/ FIRE PLANS. | | | PLEASE SEE PLANS REFLECT 1999 NEC, 1997 | | | SBC, AND THE SBCCI ETC. | | | PLEASE SE COMMENTS FROM OTHER TRADES | | | WITH RESPECT TO CODES. (BUILDING). | | | | | | 2) NOTE:NO, PLEASE SEE ONLY THE | | | PRINTED NAME AND LICENSE # OF THE | | | ARCHITECT WAS ADDED. PLEASE SEE THE FIRM | | | TITLE BLOCK IS STILL MISSING THE | | | REQUIRED FIRM LICENSE NUMBER WHICH IS | | | ALSO KNOWN AS THE CERTIFICATE OF | | | AUTHORIZATION NUMBER. | | | FS 481.219, FAC 61G1-16.004 | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE MISSING INFORMATION | | | ON TITLE BLOCKS FOR ARCHITECT AND | | | ARCHITECTURAL FIRM. PLEASE SEE FLORIDA | | | ADMINISTRATIVE CODE 61G1-16.004 AND | | | FLORIDA STATUES 481.219. | | | MISSING THE PRINTED NAME AND LICENSE # | | | OF THE ARCHITECT, MISSING THE FIRM | | | LICENSE # FOR THE ARCHITECTURAL FIRM. | | | | | | 3) NOTE: OK. | | | | | | 4) NOTE:OK, HOWEVER SEE NEW NOTES. | | | | | | ** PREVIOUS REVIEW NOTE** | | | PLEASE SEE MINIMUM OCP FOR AHU, | | | HEAT. PLEASE SEE MIN OCP IS 125%. | | | PLEASE ADJUST. | | | | | | 5) NOTE: OK. | | | | | | 6) NOTE: OK. | | | | | | 7) NOTE: OK | | | | | | ******** NEW NOTES ****** | | | | | | 8) NOTE: PLEASE SEE RISER AND PANEL "A" | | | AS THE OCP FOR THE AHU WAS ADJUSTED AND | | | INCREASED TO 30A?S. PLEASE SEE THAT THE | | | CONDUCTOR SIZE WAS CHANGED ON THE PANEL | | | SCHEDULE, HOWEVER PLEASE SEE RISER | | | | | | 9) NOTE: PLEASE SEE A LIGHTING CONTROL | | | PANEL IS BEING SHOWN TO MEET FBC CHAPTER | | | 13-415.1.ABC.1.1, .1.2, .1.3, HOWEVER | | | PLEASE PROVIDE THE OVER-RIDE DEVICES AT | | | THIS TIME AND LOCATED IN THE SPACES AS | | | REQUIRED. | | | PLEASE INDICATE THE DEVICE AND KNOW, | | | WHEN USING A TIMED OVER-RIDE (4HRS MAX) | | | AND OCCUPANCY SENSOR TYPE DEVICE (30MINS | | | MAX). PLEASE SEE AREAS WITH SEPARATE | | | SPACES. | | | PLEASE ALSO SEE 13-415.1.AB.1, AND | | | 13-415.2.ABC.1 FOR MAX LIGHTING | | | DENSITIES PERMITTED. | | | PLEASE SEE BOTH TABLES AND INDICATE. | | | PLEASE PROVIDE ALL CONTROLLED CIRCUITING | | | ON TIME/PANEL SCHEDULE. PLEASE ALSO | | | PROVIDE THE SCHEDULING TIMES. | | | | | | ** WHEN RESUBMITTING PLANS, PLEASE | | | COMPLETELY REMOVE ALL OLD/VOIDED SHEETS | | | AND ONLY INSERT NEW REVISED SHEETS INTO | | | TWO COMPLETE SETS FOR REVIEW AND | | | STAMPING. | | | | | | ** PLEASE SEE ANY COMMENTS FROM OTHER | | | TRADES WHICH MAY AFFECT ELECTRICAL | | | PLANS. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | DPALMER@WPB. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-05-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-05-04 |
Time |
19:19 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-05-04 |
Time |
18:03 |
Sent To |
|
|
| Notes |
| 2006-05-04 00:00:00 | IN ELEC FOR REVIEW | | | ******** UNSAT ********** | | | | | | | | | ** PLEASE KNOW, PLANS HAVE ONLY BEEN | | | SUBMITTED FOR "PLAN REVIEW" AND HAVE NOT | | | BEEN SUBMITTED FOR PERMIT. | | | | | | 1) NOTE: PLEASE ADJUST AND REFLECT ALL | | | CURRENT CODES IN AFFECT. | | | PLEASE SEE WE ARE UNDER THE 2002 | | | NFPA-70( NEC), 2003 NFPA-101, 2002 | | | NFPA-72. | | | PLEASE KNOW,THESE CODES AT A MININUM | | | SHALL BE REFERENCED ON ARCHITECTURALS | | | AND ELECTRICAL/ FIRE PLANS. | | | PLEASE SEE PLANS REFLECT 1999 NEC, 1997 | | | SBC, THE SBCCI ETC. | | | PLEASE SE COMMENTS FROM OTHER TRADES | | | WITH RESPECT TO CODES. (BUILDING). | | | | | | 2) NOTE: PLEASE SEE MISSING INFORMATION | | | ON TITLE BLOCKS FOR ARCHITECT AND | | | ARCHITECTURAL FIRM. PLEASE SEE FLORIDA | | | ADMINISTRATIVE CODE 61G1-16.004 ANF | | | FLORIDA STATUES 481.219. | | | MISSING THE PRINTED NAME AND LICENSE # | | | OF THE ARCHITECT, MISSING THE FIRM | | | LICENSE # FOR THE ARCHITECTURAL FIRM. | | | | | | 3) NOTE: PLEASE VERIFY ELECTRICAL PLANS | | | WHICH ARE NOTED AS BEING DONE BY A | | | PROFESSIONAL ENGINEER, HOWEVER TITLE | | | BLOCK REFLECT "MECHANICAL" . PLEASE SEE | | | FS 471 FOR WORKING WITHIN SCOPE OF | | | LICENSURE. PLEASE CLARIFY. | | | | | | 4) NOTE: PLEASE SEE MININUM OCP FOR AHU, | | | HEAT. PLEASE SEE MIN OCP IS 125%. | | | PLEASE ADJUST. | | | | | | 5)NOTE: PLEASE SEE 700.12E, WHICH | | | REQUIRES THE EM/EXT LTS TO BE CIRCUITED | | | TO THE LOCAL LIGHTING BRNACH CIRCUIT IN | | | ANY ONE AREA. | | | PLEASE SEE AS INDICATED ON PLANS FOR | | | LAYOUT, CIRCUITS ETC. IT DOES NOT SEEM, | | | PLANS MEET THE EXCEPTION TO USE A | | | "LOCK-OFF" DEVICES. | | | **PLEASE ALSO KNOW, ANY PROPOSED | | | "LOCK-OFF DEVICES" MUST BE APPROVED BY | | | THE AHJ. MANY OF THESE DEVICES ARE NOT | | | ACCEPTABLE TO THIS AHJ. | | | | | | 6) NOTE: PLEASE LABEL/NOTE COLOR CODING | | | FOR 277/480V PER LOCAL AHJ AS BROWN , | | | PURPLE , YELLOW. | | | | | | 7) NOTE: PLEASE SEE MISSIG EQUIPMENT | | | GROUNDING CONDUCTOR FROMNEW PANEL "A" | | | TO TRANSFORMER. | | | 250.122,250.110 ETC. | | | | | | ** WHEN RESUBMITTING PLANS, PLEASE | | | COMPLETELY REMOVE ALL OLD/VOIDED SHEETS | | | AND ONLY INSERT NEW REVISED SHEETS INTO | | | TWO COMPLETE SETS FOR REVIEW AND | | | STAMPING. | | | | | | ** PLEASE SEE ANY COMMENTS FROM OTHER | | | TRADES WHICH MAY AFFECT ELECTRICAL | | | PLANS. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
N |
Date |
2006-10-24 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2006-10-24 |
Time |
08:37 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2006-10-24 |
Time |
08:21 |
Sent To |
|
|
| Notes |
| 2006-10-24 08:25:18 | SINCE IT IS ONLY INTERIOR CHANGES, NO ENGINEERING | | | REVIEW REQUIRED.RVC |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
N |
Date |
2006-10-24 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2006-10-23 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2006-10-23 |
Time |
15:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2006-10-23 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-10-23 |
Time |
14:34 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-10-23 |
Time |
14:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2006-09-05 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-09-05 |
Time |
13:12 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-09-05 |
Time |
13:12 |
Sent To |
|
|
| Notes |
| 2006-09-05 00:00:00 | ***PROVISO*** | | | | | | 1) FIRE REVIEW IS OK FOR CODE | | | COMPLIANCE. PLEASE SEE ELECTRICAL | | | COMMENT (2). | | | | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2006-07-10 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2006-07-10 |
Time |
15:19 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2006-07-10 |
Time |
15:04 |
Sent To |
|
|
| Notes |
| 2006-07-10 00:00:00 | 1. DEMOLITION, RENOVATION, AND | | | CONSTRUCTION TO COMPLY WITH NFPA 241. | | | | | | 2. DEBRIS SHALL BE REMOVED FROM THE SITE | | | DAILY. | | | | | | 3. SEPARATE PLANS AND PERMITS REQUIRED | | | FOR FIRE SPRINKLER OR FIRE ALARM SYSTEM | | | REMODEL. | | | | | | 4. NO SOFFITS SHALL INTERFERE WITH THE | | | OPERATION OF ANY FIRE SPRINKLER HEADS. | | | | | | 5. INTERIOR FINISH CLASSIFICATIONS SHALL | | | COMPLY WITH MINIMUM CODE REQUIREMENTS. | | | | | | MIKE CARSILLO, CHIEF FIRE PREVENTION | | | OFFICER | | | 804-4709 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2006-05-31 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-05-31 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-05-31 |
Time |
11:06 |
Sent To |
|
|
| Notes |
| 2006-05-31 00:00:00 | ***DENIED*** | | | | | | 1) NOTE REGARDING ADDRESS AT REAR DOOR | | | ACKNOWLEDGED. ADDRESS REQUIRED NEAR | | | FRONT ENTRANCE DOOR, AND SHALL MEET CODE | | | REQUIREMENTS FOR SIZE AND CONTRASTING TO | | | BACKGROUND FOR VISIBILITY. | | | | | | 2) DUCT SMOKE DETECTORS WHERE PROVIDED, | | | ARE REQUIRED IN SUPPLY DUCT IN SYSTEMS | | | GREATER THAN 2000CFM'S AND SHALL | | | INITIATE A GENERAL FIRE ALARM IN | | | ACCORDANCE WITH LOCAL REQUIREMENTS. | | | | | | 3) IN ADDITION TO FLORIDA FIRE | | | PREVENTION CODE, LIFE SAFETY TO COMPLY | | | WITH NFPA 101, 2003 EDITION. | | | | | | 4) SEPARATE SHOP DRAWINGS AND PERMITS | | | REQUIRED FOR FIRE SPRINKLER AND FIRE | | | ALARM REMODEL. ANY NEW SOFFITS SHALL NOT | | | INTERFERE WITH FIRE SPRINKLER COVERAGE. | | | | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2006-12-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-12-22 |
Time |
08:57 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-22 |
Time |
08:57 |
Sent To |
E |
|
| Notes |
| 2006-12-22 08:57:29 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2006-11-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-11-30 |
Time |
13:25 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-11-30 |
Time |
13:25 |
Sent To |
E |
|
| Notes |
| 2006-11-30 13:25:52 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
|
Date |
2006-11-29 |
|
|
Cont ID |
|
| Sent By |
mmiller |
Date |
2006-11-29 |
Time |
19:47 |
Rev Time |
0.00 |
| Received By |
mmiller |
Date |
2006-11-29 |
Time |
19:47 |
Sent To |
B |
|
| Notes |
| 2006-11-29 19:48:06 | SENT TO JIM'S WITMER DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-09-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-29 |
Time |
08:42 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-29 |
Time |
08:42 |
Sent To |
|
|
| Notes |
| 2006-10-12 17:30:36 | TO "COMM" BD#54 | | 2006-09-29 00:00:00 | WAITING FOR "COMM" BD-NEW SHEETS | | | SUBMITTED FOR "MECH" AND "F" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-08-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-18 |
Time |
08:36 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-18 |
Time |
08:36 |
Sent To |
|
|
| Notes |
| 2006-08-23 00:00:00 | TO "COMM" BD#40 | | 2006-08-18 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-06-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-15 |
Time |
16:39 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-15 |
Time |
16:39 |
Sent To |
|
|
| Notes |
| 2006-06-26 00:00:00 | TO "COMM" BD#21 | | 2006-06-15 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-05-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-30 |
Time |
10:07 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-30 |
Time |
10:07 |
Sent To |
|
|
| Notes |
| 2006-05-30 00:00:00 | TO "COMM" BD#23 W/APPL.--CHANGE FROM | | | PLAN REV. TO PERMIT |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-06-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-30 |
Time |
16:37 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-05 |
Time |
14:51 |
Sent To |
|
|
| Notes |
| 2006-04-19 00:00:00 | TO "COMM" BD#23 | | 2006-04-05 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2006-10-17 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-10-17 |
Time |
11:17 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-10-17 |
Time |
11:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2006-08-24 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-08-24 |
Time |
14:35 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2006-08-24 |
Time |
14:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2006-07-18 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-07-18 |
Time |
11:39 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2006-07-18 |
Time |
11:39 |
Sent To |
|
|
| Notes |
| 2006-07-18 00:00:00 | *** DENIED *** | | | 1) PLEASE SEE ELECTRICAL REVIEW NOTE #2 | | | AND CORRECT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-05-10 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-05-10 |
Time |
12:13 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-05-10 |
Time |
12:13 |
Sent To |
|
|
| Notes |
| 2006-05-10 00:00:00 | ** FOR PLAN REVIEW ONLY NOT FOR PERMIT * | | | 1) SEE ELECTRICAL REVIEW NOTES #1&2. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2006-10-30 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-10-30 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-10-30 |
Time |
13:45 |
Sent To |
E |
|
| Notes |
| 2006-10-30 13:46:33 | PASSED/PROVISO | | | | | | SHT P-1 AIR CHAMBERS ARE NOT APPROVED. SECTION 604.9 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2006-09-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-09-05 |
Time |
09:20 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-09-05 |
Time |
09:20 |
Sent To |
|
|
| Notes |
| 2006-09-05 00:00:00 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | FBC-2004 BUILDING | | | FBC-2004 CHAPTER 11 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | **PLUMBING PLANS ACCEPTABLE AT THIS | | | TIME. AS SOON AS COMMENT #1 IS RESOLVED, | | | THEN PLUMBING WILL BE PASSED. | | | | | | A. FROM PREVIOUS REVIEW. COMMENT NUMBERS | | | TO REMAIN THE SAME FOR CLARITY: | | | | | | 1. ALL SHEETS, THE TITLE BLOCK FOR THE | | | ARCHITECT MUST, AT A MINIMUM, CONTAIN | | | THE FOLLOWING INFORMATION: | | | 61G1-16.004(2)(5). THE FIRM LICENSE | | | NUMBER, AND A SPACE FOR THE PRINTED NAME | | | OF THE PERSON SEALING THE DOCUMENT. FS | | | 481.219 481.2055. | | | ***RESPONSE NOTED, BUT THE CERTIFICATE | | | OF AUTHORIZATION, (BUSINESS NUMBER), IS | | | NOT SHOWN ON THE TITLE BLOCK. | | | ******RESPONSE NOTED, BUT THE | | | CERTIFICATE OF AUTHORIZATION FOR "ZAG" | | | IS NOT SHOWN. | | | | | | 2. OK | | | 3. OK | | | 4. OK | | | 5. OK | | | 6. OK | | | 7. OK | | | 8. OK | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2006-07-26 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-07-26 |
Time |
11:29 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-07-26 |
Time |
11:29 |
Sent To |
|
|
| Notes |
| 2006-07-26 00:00:00 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | FBC-2004 BUILDING | | | FBC-2004 CHAPTER 11 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | A. FROM PREVIOUS REVIEW. COMMENT NUMBERS | | | TO REMAIN THE SAME FOR CLARITY: | | | | | | 1. ALL SHEETS, THE TITLE BLOCK FOR THE | | | ARCHITECT MUST, AT A MINIMUM, CONTAIN | | | THE FOLLOWING INFORMATION: | | | 61G1-16.004(2)(5). THE FIRM LICENSE | | | NUMBER, AND A SPACE FOR THE PRINTED NAME | | | OF THE PERSON SEALING THE DOCUMENT. FS | | | 481.219 481.2055. | | | ***RESPONSE NOTED, BUT THE CERTIFICATE | | | OF AUTHORIZATION, (BUSINESS NUMBER), IS | | | NOT SHOWN ON THE TITLE BLOCK. | | | | | | 2. SHT A-0 ACCESSIBILITY CODE TO READ | | | FBC-2001 CHAPTER 11. | | | ***RESPONSE NOTED, BUT MY FAULT, THIS | | | SHOULD READ FBC-2004 CHAPTER 11. (SORRY) | | | | | | 3. OK | | | | | | 4. OK | | | | | | 5. OK | | | | | | 6. SUBMIT A DETAIL FOR THE DRINKING | | | FOUNTAIN SHOWING COMPLIANCE WITH 11-4.15 | | | AND ALL SUBSECTIONS, AS WELL AS SECTION | | | 11-4.1.3(10)(A) PROVISIONS FOR THOSE WHO | | | HAVE DIFFICULTY BENDING OR STOOPING. - | | | WALL MOUNTED OR CANTILEVERED UNITS SHALL | | | HAVE FORWARD APPROACH CLEAR FLOOR SPACE. | | | ***RESPONSE NOTED, BUT PARALLEL APPROACH | | | STILL SHOWN AT DETAIL 4. FORWARD | | | APPROACH REQUIRED. | | | | | | 7. OK | | | | | | 8. OK | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-05-27 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-05-27 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-05-27 |
Time |
11:29 |
Sent To |
|
|
| Notes |
| 2006-05-27 00:00:00 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | FBC-2004 BUILDING | | | FBC-2004 CHAPTER 11 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1. ALL SHEETS, THE TITLE BLOCK FOR THE | | | ARCHITECT MUST, AT A MINIMUM, CONTAIN | | | THE FOLLOWING INFORMATION: | | | 61G1-16.004(2)(5). THE FIRM LICENSE | | | NUMBER, AND A SPACE FOR THE PRINTED NAME | | | OF THE PERSON SEALING THE DOCUMENT. FS | | | 481.219 481.2055. | | | | | | 2. SHT A-0 ACCESSIBILITY CODE TO READ | | | FBC-2001 CHAPTER 11. | | | | | | 3. SHT A-3 FINISH PLAN. PLEASE EXPLAIN | | | HOW PAINTED WALLS MEETS THE CODE | | | REQUIREMENT FOR NONABSORBENT MATERIAL | | | PER SECTION 1210.2 | | | | | | 4. SHT AC-1 DETAIL 6 - W/C DETAIL. SHOW | | | HEIGHT PER SECTION 11-4.16.3. | | | | | | 5. SHT AC-1 DETAIL 3 - LAV CLEARANCE. | | | SHOW REQUIREMENTS FOR EXPOSED PIPES AND | | | SURFACES PER 11-4.19.4 AND FAUCETS PER | | | 11-4.19.5. | | | | | | 6. SUBMIT A DETAIL FOR THE DRINKING | | | FOUNTAIN SHOWING COMPLIANCE WITH 11-4.15 | | | AND ALL SUBSECTIONS, AS WELL AS SECTION | | | 11-4.1.3(10)(A) PROVISIONS FOR THOSE WHO | | | HAVE DIFFICULTY BENDING OR STOOPING. - | | | WALL MOUNTED OR CANTILEVERED UNITS SHALL | | | HAVE FORWARD APPROACH CLEAR FLOOR SPACE. | | | | | | 7. SHT P-1 SUBMIT MANUF. SPECIFICATIONS | | | FOR THE INSTANTANEOUS WATER HEATER. | | | LISTING REQUIRED. SECTION 303.4 | | | | | | 8. SHT P-1 DETAIL #3 TOILET ROOM WATER | | | RISER DIAGRAM. RPZV BACKFLOW SHALL BE | | | LOCATED A MAXIMUM 4' ABOVE THE FLOOR FOR | | | SERVICING AND CERTIFICATION. INDIRECT | | | WASTE RECEPTOR SHALL RECIEVE DISCHARGE | | | FROM BACKFLOW. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|