| Plan Review Stops For Permit 06031571 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2007-12-07 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-12-07 |
Time |
10:46 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-12-07 |
Time |
07:48 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2007-07-11 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-07-11 |
Time |
05:53 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-07-10 |
Time |
12:21 |
Sent To |
P |
|
| Notes |
| 2007-07-10 13:13:45 | BUILDING PLAN REVIEW | | | PERMIT: 06031571 | | | ADD: 3008 RIDGEWAY AVE | | | CONT: T&S CONSTRUCTION INC. | | | TEL: (561)###-#### | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW:REV. | | | ACTION: DENIED | | | | | | 1) THE DRAWINGS SHALL BE SIGNED/DATEDAND SEAL BY THE | | | ENGINEER OF RECORD. THE ONLY PERSON WHO CAN MAKE | | | CHANGES TO THE DRAWINGS IS THE ENGINEER OF RECORD. THE | | | DRAWINGS SUBMITTED ARE NOT SIGNED BY THE ENGINEER OF | | | RECORD. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | 805-6726 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2006-10-19 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-10-19 |
Time |
13:16 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-10-19 |
Time |
11:26 |
Sent To |
|
|
| Notes |
| 2006-10-19 13:20:32 | SEPERATE PERMIT REQUIRED FOR FLAT ROOF. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-07-10 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-07-10 |
Time |
11:01 |
Rev Time |
1.25 |
| Received By |
alange |
Date |
2006-07-10 |
Time |
10:53 |
Sent To |
|
|
| Notes |
| 2006-07-10 00:00:00 | DENIED | | | | | | | | | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT | | | SHALL BE RECORDED AT PALM BEACH COUNTY | | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | | BLANK FORMS ARE AVAILABLE FROM THIS | | | OFFICE. | | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE | | | RE-RECORDED IF THE DESCRIBED IMPROVEMENT | | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | | 90 DAYS OF RECORDING. | | | | | | 6.ALL PRODUCT APPROVALS SUBMITTED WITH | | | QUALITY ASSURANCE SHALL HAVE THE | | | FOLLOWING STATE APPROVAL ATTACHED. | | | | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A STATE PRODUCT APPROVAL | | | SHEETS THAT LISTS THE PRODUCT IDENTITY | | | NUMBER FROM THE STATE. IF THE PRODUCT | | | DOES NOT HAVE STATEWIDE APPROVAL, SUBMIT | | | AN APPLICATION FOR LOCAL PRODUCT | | | APPROVAL OR SITE SPECIFIC FORM PER RULE | | | 9B-72. SEE ATTACHMENT. | | | WWW.FLORIDABUILDING.ORG | | | | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. SUBMIT ONE COPY OF | | | OLD PAGES FOR REFERENCE. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET | | | OR SPECIFICATION PAGE WHERE THE CHANGES | | | CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | ART LANGE | | | CONSTRUCTION SERVICES DEPARTMENT | | | BUILDING PLANS EXAMINER | | | 561-805-6672 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-04-18 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-04-18 |
Time |
09:47 |
Rev Time |
2.50 |
| Received By |
alange |
Date |
2006-04-18 |
Time |
09:47 |
Sent To |
|
|
| Notes |
| 2006-04-18 00:00:00 | DENIED | | | | | | | | | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT | | | SHALL BE RECORDED AT PALM BEACH COUNTY | | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | | BLANK FORMS ARE AVAILABLE FROM THIS | | | OFFICE. | | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE | | | RE-RECORDED IF THE DESCRIBED IMPROVEMENT | | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | | 90 DAYS OF RECORDING. | | | | | | 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 3.BASED ON ICC BUILDING VALUATION DATA | | | THE PERMIT VALUE HAS BEEN REVISED TO | | | $21,765.ADDITIONAL PERMIT FEES ARE | | | DUE. | | | | | | 4.SQUARE FOOTAGE ON APPLICATION HAS | | | BEEN CORRECTED. | | | | | | 5.SUBMIT TWO COMPLETE SETS OF PRODUCT | | | APPROVALS WITH QUALITYA ASSURANCE AND | | | THE FOLLOWING STATE PRODUCT APPROVAL | | | ATTACHED. | | | | | | 6.ALL PRODUCT APPROVALS SUBMITTED WITH | | | QUALITY ASSURANCE SHALL HAVE THE | | | FOLLOWING STATE APPROVAL ATTACHED. | | | | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A STATE PRODUCT APPROVAL | | | SHEETS THAT LISTS THE PRODUCT IDENTITY | | | NUMBER FROM THE STATE. IF THE PRODUCT | | | DOES NOT HAVE STATEWIDE APPROVAL, SUBMIT | | | AN APPLICATION FOR LOCAL PRODUCT | | | APPROVAL OR SITE SPECIFIC FORM PER RULE | | | 9B-72. SEE ATTACHMENT. | | | WWW.FLORIDABUILDING.ORG | | | | | | 7.THOSE PRODUCT APPROVALS WHICH ARE | | | REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL | | | FOR JURISDICTIONAL APPROVAL.WPB | | | AMENDMENT TO FBC 106.3.3. | | | | | | 8.A DESIGN PROFESSIONAL OR AN OWNER | | | MUST ELECT ONE OR A COMBINATION OF | | | LEVELS OF ALTERATION PURSUANT TO | | | SECTIONS 303, 304 AND 305 OF THIS CODE. | | | SHOW HOW PLANS WILL COMPLY WITH THE | | | SECTION(S) SELECTED.2004 FBC EXISTING | | | BUILDING 301.5 | | | | | | 9.ALL PLANS SUBMITTED AFTER OCTOBER, | | | 1, 2005 SHALL BE DESIGNED TO THE 2004 | | | FLORIDA BUILDING CODE.ALSO UPDATE ANY | | | CODE SECTIONS SHOWN | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. SUBMIT ONE COPY OF | | | OLD PAGES FOR REFERENCE. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET | | | OR SPECIFICATION PAGE WHERE THE CHANGES | | | CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | ART LANGE | | | CONSTRUCTION SERVICES DEPARTMENT | | | BUILDING PLANS EXAMINER | | | 561-805-6672 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2007-11-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-11-19 |
Time |
10:41 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-11-19 |
Time |
09:48 |
Sent To |
M |
|
| Notes |
| 2007-11-19 10:43:38 | REDLINED PLANS. | | | SD'S ARE SA FOR SMOKE ALARMS. | | | CLOSET LIGHTS ARE TO MEET 410.8 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2007-07-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-07-30 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-07-30 |
Time |
10:40 |
Sent To |
M |
|
| Notes |
| 2007-07-30 11:07:16 | | | | *** UNSAT *** | | | | | | 1) NOTE: PLEASE SEE THAT THE DESIGNER OF RECORD SHALL | | | SIGN PLANS. IF THE DESIGNER OF RECORD HAS CHANGED | | | PLEASE SUBMIT NOTARIZED LETTERS FOR CHANGE OF | | | DESIGNER. | | | FBC 106.1.2 | | | FS 481, 471, 489 | | | | | | 2) NOTE: PLEASE SHOW A REVISED ELECTRICAL RISER | | | DIAGRAM. PLEASE INCLUDE THE EQUIPMENT GROUNDING | | | CONDUCTOR TO NEW SUB PANEL. | | | PLEASE SEE 250.122, 250.110 ETC. | | | | | | 3) NOTE: PLEASE SUBMIT A LAYOUT OF THE NEW SMOKE ALARMS | | | IN DWELLING INSIDE AND OUTSIDE SLEEPING ROOMS. | | | R313, NFPA-72 11.5.1.1, 11.8.3 | | | PLEASE SHOW LOCATIONS. | | | | | | 4) NOTE: PLEASE SPECIFY NEW LIGHTS IN CLOSET AS THE | | | SYMBOL/FIXTURE LEGEND DOES NOT CORRELATE OR INDICATE | | | TYPE OF FIXTURE. BASED ON SCALE ON PLANS AND LOCATIONS, | | | IT NOT APPEAR 410.8 IS MET? | | | | | | 5) NOTE: PLEASE SEE PLANS NOW INCLUDE THE RELOCATED CU | | | YET NOT GFI IS SHOWN FOR THIS AS REQUIRED PER 210.63, | | | 210.8A | | | | | | 6) NOTE: PLEASE REVISE LOAD CALCULATIONS TO COORDINATE | | | WITH PANEL SCHEDULE. SEE KITCHEN SMALL APPLIANCE | | | CIRCUITS FOR EXAMPLE. | | | PLEASE SEE 210.52B1, 210.11C1, 220.16. | | | | | | 7) NOTE: PLEASE SEE REDLINED PLANS AS OF OCT 06 | | | REQUIRED THE PANEL SCHEDULE TO BE REVISED TO BE | | | SPECIFIC TO ROOMS AND AREAS IN WHICH THEY FEED. | | | *PLEASE SEE 408.4. *SECTION 408.4 WAS REVISED FOR THE | | | 2005 CODE TO REQUIRE THAT THE IDENTIFICATION FOR EVERY | | | CIRCUIT SUPPLIED BY A PANEL-BOARD OR SWITCHBOARD BE | | | LEGIBLE AND CLEARLY STATE THE SPECIFIC PURPOSE FOR | | | WHICH THE CIRCUIT IS USED. CIRCUITS USED FOR THE SAME | | | PURPOSE MUST BE IDENTIFIED AS TO THEIR LOCATION. FOR | | | EXAMPLE, SMALL APPLIANCE BRANCH CIRCUITS CAN SUPPLY | | | OUTLETS IN THE KITCHEN, DINING ROOM, AND KITCHEN | | | COUNTERTOPS. IDENTIFYING THE CIRCUITS AS SMALL | | | APPLIANCE BRANCH CIRCUITS IS NOT ACCEPTABLE; INSTEAD, | | | THEY SHOULD BE IDENTIFIED AS ``KITCHEN WALL | | | RECEPTACLES,'' ``DINING ROOM FLOOR RECEPTACLE,'' OR | | | ``KITCHEN COUNTERTOP RECEPTACLES LEFT OF SINK.'' | | | CIRCUIT DIRECTORIES CONTAINING MULTIPLE ENTRIES WITH | | | ONLY ``LIGHTS'' OR ``OUTLETS'' DO NOT PROVIDE THE | | | SUFFICIENT DETAIL REQUIRED BY THIS SECTION.* | | | 408.4, 310.16, 240.4 ETC | | | FBC 106.3.5.4 | | | | | | | | | | | | * PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-10-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-10-17 |
Time |
17:59 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-10-17 |
Time |
17:59 |
Sent To |
B |
|
| Notes |
| 2006-10-17 17:59:21 | **REDLINED FOR PANEL SCHEDULE TO BE UPDATED TO | | | CORRELATE OCP / LOADS AND CONDUCTOR SIZES. | | | 240.4,310.16, 408.4 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-06-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-06-21 |
Time |
18:01 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-06-21 |
Time |
16:53 |
Sent To |
M |
|
| Notes |
| 2006-06-21 00:00:00 | *** UNSAT *** | | | | | | 1) NOTE: PLEASE SEE THE RECEPT FOR NEW | | | WASHER IS NOT SHOWN ON PLANS. PANEL | | | SCHEDULE ETC SHOWS NEW , HOWEVER NOT | | | SHOWN. | | | PLEASE CORRELATE. | | | 215.5 | | | | | | 2) NOTE: PLEASE SEE PANEL SCHEDULE SHOWS | | | 40A OCP FOR THE RANGE WHICH IS BEING | | | SHOWN AS 12KW. PLEASE KNOW, WITH THE | | | LOAD SHOWN AS 12KW, THE 40A CIRUIT AS | | | SHOWN EXCEEDS SAFE OPERATION AND OCP FOR | | | PROTECTION OF BRANCH CIRCUIT. | | | 240.4,310.16.ETC. | | | PLEASE VERIFY AND ADJUST. | | | | | | 3) NOTE: PLEASE SEE BATH RECEPTS SHALL | | | BE GFI/ GFI PROTECTED PER 210.8A1 | | | | | | 4) NOTE: PLEASE CORRELATE WATER HEATER | | | SHOWN ON PANEL SCHEDULE AND KW RATING ON | | | LOAD CALCULATIONS. | | | PLEASE SEE ONE SHOWS 4.5 KW AND THE | | | OTHER SHOWS 3KW? | | | PLEASE BE SURE TO SEE IF THE KW IS | | | 4500VA, THEN PLEASE ADJUST OCP AND AWG | | | SIZES. PER 240.4,310.16 ETC | | | 215.5 | | | | | | 5) NOTE: PLEASE VERIFY CIRCUITING AS | | | SHOWN. PLEASE SEE MAX VA PERMITTED ON | | | #14AWG AND 15A OCP. PLEASE SEE A MAX OF | | | 1440VA. | | | 215.5. PLEASE SEE OTHER CIRCUITS. | | | | | | 6) NOTE: PLEASE SEE NEC 2002 FOR CORRECT | | | LOAD CALCULATIONS. PLEASE SEE SOME | | | APPEAR TO BE SHOWN FOR COMMERCIAL AND | | | SOME FOR RESIDENTIAL?? | | | | | | 7) NOTE: PLEASE SEE A LIGHTING CONTROL | | | SWITCH WILL BE REQUIRED IN THE PATH OF | | | EGRESS WHEN ENTERING THE LAUNDRY RM. | | | PLEASE SEE A 3-WAY SW MAY BE USED TO ADD | | | TO THE OTHER SW AS SHOWN. | | | PLEASE KNOW, THE SWITCHING SHOULD BE | | | LOCATED IN THE PATH OF EGRESS AND ALWAYS | | | WITH THE DIRECTION OF EGRESS TRAVEL. | | | 210.70, 2002 NEC, NFPA-101 CHAPT 24, | | | CHAPT 8 7.8 | | | | | | ** PLEASE SEE ANY OTHER COMMENTS FROM | | | OTHER TRADES WHICH MAY AFFETC THE | | | ELECTRICAL PLANS. | | | | | | ** PLEASE BE SURE PLANS REFLECT THE | | | CURRENT CODES IN EFFECT 2004 FBC , 2002 | | | NEC AT A MIN. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-04-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-04-11 |
Time |
07:49 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-04-11 |
Time |
07:17 |
Sent To |
M |
|
| Notes |
| 2006-04-11 00:00:00 | ************ UNSAT ***************** | | | | | | 1) NOTE: PLEASE SEE PLAN SETS CONTAIN | | | MANY AREAS ON ELECTRICLA AND OTHER | | | SHEETS WHICH CONTAIN "HAND-DRAWN" ITEMS | | | ON PLANS WHICH ARE SIGNED, DATED AND | | | SEALED BY AN ENGINEER. PLEASE SEE FS | | | 471.025, THIS IS NOT PERMITTED AND WILL | | | NOT BE ACCEPTED. PLEASE HAVE SHEETS | | | RE-PRINT WITH CHANGES AND ANY | | | CORRECTIONS FROM PLAN REVIEW COMMENTS. | | | 215.5 | | | ** PLEASE KNOW, THIS COMMENTS IS FOR ALL | | | SHEETS AND FOR ALL TRADES WHETHER OR NOT | | | COMMENT IS MADE BY OTHER REVIEWER(S). | | | | | | 2) NOTE: PLEASE SEE RISER MENTIONS NEW | | | #10 FOR DRYER AND WATER HEATER, HOWEVER | | | PLEASE SEE THE "BRIEF" PANEL SCHEDULE | | | PROVODED DOES NOT CORRELATE WITH THIS. | | | ALL CIRCUITS ON THE 4 CIRCUIT SCHEDULE | | | SHOWS ONLY 1-POLE 20A CIRCUITS??? | | | | | | A) PLEASE SEE 220.18 FOR MIN KW AND | | | CIRCUIT RATING FOR DRYER. | | | 240.4,310.16 | | | | | | B) PLEASE SEE 422.13 FOR MIN SIZE AND | | | OCP FOR WATER HEATER, 125% FOR | | | NAMEPLATE. | | | | | | PLEAS ADJUST CONDUCTOR AND OCP SIZES. | | | | | | 3) NOTE: PLEASE VERIFY ON PLANS IF NEW | | | LOADS ARE TAKING THE PLACE OF THE | | | EXISTING WASHER, DRYER, WATER HEATER OR | | | ARE THESE NEW ADDTIONAL LOADS. | | | PLEASE PROVIDE MIN LOAD CALCUALTIONS FOR | | | NEW ADDED LOADS. | | | 215.5,220 | | | | | | 4) NOTE: PLEASE SEE WATER HEATER IS | | | BEING SHOWN WITH A RECEPT FOR | | | DISCONNECT/PLUG IN OF UNIT. PLEASE SEE | | | 422.30 AS A DISCONNECTING MEANS IS | | | REQUIRED AND MAY NOT PLUG IN UNIT. | | | | | | 5) NOTE: PELASE INCLUDE ANY NEW GFI | | | RECEPTS ON PLANS (PRINTED) NOT DRAWN. | | | 210.52D, 210.8A1,3 ETC. | | | | | | 6) NOTE: PLEASE SEE ELECTRICAL SYMBOL | | | LEGEND, SHOWS 125A PANELAND RISER AND | | | PLANS MENTIONS 200A PANEL EXISTING? | | | PLEASE CORRELATE | | | | | | 7) NOTE: PLEASE SEE FBC R313, FOR SD'S | | | TO BE ADDED TO THE EXISTING DWELLING FOR | | | THE LEVEL OF ALTERATION TO THE EXISTING | | | BUILDING. | | | | | | PLEASE SEE ANY COMMENTS FROM OTHER | | | REVIEWER(S) WHICH MAY AFFECT ELECTRICAL | | | PLANS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2007-11-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-08 |
Time |
14:11 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-11-08 |
Time |
14:11 |
Sent To |
Z |
|
| Notes |
| 2007-11-08 14:11:36 | TO "Z" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2007-07-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-07-05 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-07-05 |
Time |
14:14 |
Sent To |
E |
|
| Notes |
| 2007-07-05 14:15:14 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-10-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-10-14 |
Time |
16:54 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-10-14 |
Time |
16:54 |
Sent To |
E |
|
| Notes |
| 2006-10-14 16:54:59 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-06-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-20 |
Time |
09:38 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-20 |
Time |
09:38 |
Sent To |
E |
|
| Notes |
| 2006-06-20 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-04-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-10 |
Time |
16:13 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-10 |
Time |
16:13 |
Sent To |
E |
|
| Notes |
| 2006-04-10 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-04-18 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-04-18 |
Time |
09:47 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-04-03 |
Time |
11:28 |
Sent To |
|
|
| Notes |
| 2006-04-03 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2007-11-26 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-11-26 |
Time |
09:40 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-11-26 |
Time |
09:40 |
Sent To |
P |
|
| Notes |
| 2007-11-26 09:43:21 | MECHANICAL REVISION | | | | | | *** PROVISO *** | | | 1) THE CLOTHES DRYER VENT TERMINATION MAY NOT DISCHARGE | | | NEAR THE A/C CONDENSER UNIT, SEE 2004 FBC/M 501.2 . | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2007-07-30 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-07-30 |
Time |
11:52 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-07-30 |
Time |
11:52 |
Sent To |
|
|
| Notes |
| 2007-07-30 12:05:02 | *** DENIED *** | | | 1) THE CLOTHES DRYER VENT MAY NOT DISCHARGE NEAR THE | | | A/C CONDENSER UNIT, SEE 2004 FBC/M 501.2 , PLEASE | | | CORRECT. | | | | | | 2) SHOW THE RELOCATED A/C CONDENSER UNIT ON THE REVISED | | | MECHANICAL PLANS (SEE REVISED ELECTRICAL PLAN), PLEASE | | | CORRECT. | | | | | | 3) THE TITLE BLOCK OF THE MECHANICAL REVISION SHOWS THE | | | JOB ADDRESS AS BELLE GLADE, PLEASE CORRECT. | | | | | | 4) SEE OTHER TRADE REVIEW NOTES REGARDING THE ENGINEER | | | OF RECORD, PLEASE CORRECT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2006-06-22 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-06-22 |
Time |
08:09 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2006-06-22 |
Time |
08:09 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-04-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-06-21 |
Time |
18:01 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2006-04-11 |
Time |
09:08 |
Sent To |
P |
|
| Notes |
| 2006-04-11 00:00:00 | *** DENIED *** | | | 1) ENGINEER'S PRINTED LICENSE NUMBER | | | MUST APPEAR IN THE TITLE BLOCK, PER FAC | | | 61G15-23.002 . | | | | | | 2) PLEASE SHOW THE SIZE OF THE DUCT FROM | | | THE EXISTING TRUNK LINE TO THE MIXING | | | BOX (IF FLEX) OR SHOW AS A RIDGE DUCT. | | | | | | 3) PLEASE SHOW BATHROOM EXHAUST FAN ON | | | MECHANICAL PLANS. | | | | | | 4) PLEASE SHOW THE CLOTHES DRYER VENT ON | | | MECH. PLANS. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2007-12-05 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-12-05 |
Time |
15:12 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-12-05 |
Time |
15:07 |
Sent To |
B |
|
| Notes |
| 2007-12-05 15:13:31 | REVISED SANITARY RISER DIAGRAM. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2007-07-30 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-07-30 |
Time |
07:35 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-07-30 |
Time |
07:24 |
Sent To |
E |
|
| Notes |
| 2007-07-30 07:34:46 | DENIED; | | | 1. REVISIONS MUST BE APPROVED, SIGNED AND SEALED BY THE | | | DESIGN PROFESSIONAL OF RECORD. | | | 2. A SANITARY RISER DIAGRAM IS REQUIRED, SEE FBC-2004 | | | BUILDING CHAPTER 1 ADMIINISTRATION AMENDMENTS SECTION | | | 106.3.5.4( 9). | | | 3. AUTOMATIC CLOTHES WASHER BRANCH DRAIN MUST DISCHARGE | | | UP OR DOWN STREAM OF THE BATHROOM GROUP. SEE FBC-2004 | | | PLUMBING SECTION 909.1. | | | 4. AUTOMATIC CLOTHES WASHER TO BE 3" NOT 2" SEE SECTION | | | 406.3. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2006-07-08 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-07-08 |
Time |
09:22 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-07-08 |
Time |
09:22 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-04-12 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-04-12 |
Time |
11:29 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-04-12 |
Time |
11:29 |
Sent To |
B |
|
| Notes |
| 2006-04-12 00:00:00 | DENIED; | | | 1.ENGINEER'S PRINTED LICENSE NUMBER | | | REQUIRED IN TITLE BLOCK PER. FAC | | | 61G15-23.002. | | | 2.HAND WRITEN ITEMS ON DRAWINGS ARE NOT | | | EXCEPTABLE. | | | 3.AUTOMATIC CLOTHES WASHER DRAIN TO BE | | | 3" FBC-2004 SEC. 406.3. | | | 4.C.O. REQUIRED ON W/M STACK AT 48" AFF. | | | 5.W/M DISCHARGE SHALL BE DOWN STREAM OF | | | THE BATHROOM GROUP. LAVATORY VENT SHOULD | | | BE UP STREAM OF SHOWER SO SHOWER IS | | | VENTED. SEC. 909.1. | | | 6.THERMAL EXPANSION CONTROL IS REQUIRED | | | PER SEC.607.3 LIST ON PLANS MEANS OF | | | CONTROL. | | | 7.A TWO WAY CLEANOUT IS REQUIRED OUT | | | SIDE NEW ADDITION BEFORE BUILDING SEWER | | | TIE-IN. SEC.708.3.5 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2007-11-14 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-11-14 |
Time |
11:38 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-11-14 |
Time |
11:38 |
Sent To |
E |
|
| Notes |
| 2007-11-14 11:39:09 | ***APPROVED - REVISION*** | | | | | | PROVISO:A/C EQUIPMENT MAY NOT PROJECT MORE THAN 4' | | | INTO A REQUIRED SETBACK. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2006-04-10 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-04-10 |
Time |
13:25 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-04-10 |
Time |
13:25 |
Sent To |
I |
|
| Notes |
|
|