| Plan Review Stops For Permit 06031567 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2006-09-26 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-09-26 |
Time |
10:23 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-09-26 |
Time |
10:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2006-06-08 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-06-08 |
Time |
08:05 |
Rev Time |
0.50 |
| Received By |
alange |
Date |
2006-06-08 |
Time |
08:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-05-11 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-05-11 |
Time |
11:20 |
Rev Time |
0.50 |
| Received By |
alange |
Date |
2006-05-11 |
Time |
11:20 |
Sent To |
|
|
| Notes |
| 2006-05-11 00:00:00 | DENIED | | | SECOND REVIEW: | | | | | | SHOW SLAB DETAIL AND METHOD OF GENERATOR | | | ATTACHMENT TO SLAB. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-04-14 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-04-14 |
Time |
16:23 |
Rev Time |
0.25 |
| Received By |
alange |
Date |
2006-04-14 |
Time |
16:23 |
Sent To |
|
|
| Notes |
| 2006-04-14 00:00:00 | DENIED | | | | | | SHOW SLAB DETAIL AND METHOD OF GENERATOR | | | ATTACHMENT TO SLAB. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
N |
Date |
2006-09-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-09-17 |
Time |
11:29 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-09-17 |
Time |
11:28 |
Sent To |
B |
|
| Notes |
| 2006-09-17 00:00:00 | REVISION SUBMITTED FOR SLAB, NOT FOR | | | ELECTRICAL REVIEW, SENT TO BUILDING | | | REVIEWER. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-06-02 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-06-02 |
Time |
15:43 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-06-02 |
Time |
15:43 |
Sent To |
B |
|
| Notes |
| 2006-06-02 00:00:00 | REDLINED, 100A DISC FOR FEEDERS FROM | | | GEN GROUPED WITH EXISTING MAIN | | | DISCONNECT PER 225.31-225.39 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-05-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-05-09 |
Time |
18:53 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-05-09 |
Time |
18:27 |
Sent To |
M |
|
| Notes |
| 2006-05-09 00:00:00 | ******** UNSAT *********** | | | | | | ** PLEASE SEE SOME NOTES FROM PREVIOUS | | | REVIEW STILL NEED TO BE ADDRESSED ALONG | | | WITH SOME NEW COMMENTS DUE TO CHANGES IN | | | PLANS MADE. | | | | | | 1) NOTE: NOTE #1, PLEASE SEE A SCHEDULE | | | WAS PROVIDED , | | | PLEASE SEE LOAD FOR AHU/ CU ON PANEL | | | SCHEDULE, PLEASE CLARIFY WHERE HEAT LOAD | | | IS ? WHEN THIS IS UNDER NORMAL POWER | | | HEAT IS BEING FED FROM SOMEWHERE? OR IS | | | HEAT NOW BEING COMPLETELY REMOVED.? | | | PLEASE SEE OCP FOR DRYER IS SHOWN AT | | | 40A'S FOR 5KW? | | | PLEASE KNOW, GEN LT, APPL, RECEPTS MAY | | | BE DERATED, ONLY THE HEAT MUST BE | | | FIGURED AT 100%, UNLESS LOAD SHEDDING IS | | | USED. | | | | | | ** PREVIOUS REVIEW ** | | | PLEASE SEE PLEASE PROVIDE A SCHEDULE FOR | | | THE TRANSFER PANEL FOR INTENDED LOADS | | | AND PLEASE CLARIFY AHU LOAD. UNLESS | | | AUTOMATIC LOAD SHEDDING IS DETAILED AND | | | PROVIDED, AHU HEAT SHALL BE FIGURED AT | | | 100%. | | | 220, 702.5 | | | PLEASE KNOW, MANY OF THE PRE-WIRED | | | PANELS DO NOT CONTAIN THE OCP WHICH MAY | | | BE NEEDED FOR THE INTENDED LOADS AND | | | ALTERATION OF LISTED EQUIPMENT IS NOT | | | PERMITTED. | | | | | | 2) NOTE: NOTE #2 NO, PLEASE SEE PLANS | | | ARE RE-DRAWN AND ARE OK, HOWEVER PLEASE | | | SEE RISER DOES NOT INDICATE A | | | DISCONNECT? | | | SOMETHING IS SHOWN, BUT NOT CLEAR WHAT | | | THIS IS? | | | | | | ** PREVIOUS REVIEW ** | | | PLEASE RE-DRAWN RISER WITH OUT | | | HAND DRAWN AND WHITE-OUT CHANGES. PLEASE | | | INCLUDE DISCONNECTING MEANS FROM | | | GENERATOR TO MAIN HOUSE AND THIS | | | DISCONNECTING MEANS SHALL BE GROUPED | | | WITH THE EXISTING MAIN. | | | 225.31-225.39. | | | | | | 3) NOTE:OK.P | | | | | | 4) NOTE:NOTE #4, PLEASE SEE SPECS | | | SUBMITTED FOR PANEL/ ATS DOES NOT | | | CORRELATE WITH PLANS AND UNIT BEING | | | INSTALLED. | | | | | | ** PREVIOUS NOTE ** | | | PLEASE SUBMIT SPECS FOR ATS/ | | | PANEL BEING INSTALLED. | | | PLEASE INDICATE THE AIC RAITNG FOR ATS. | | | NFPA-110, 6.5.2, NEC 110.9 | | | 215.5 | | | | | | 5) NOTE: NOTE #5 OK, BE SURE ALL REVISED | | | ARE SIGNED ALSO. | | | | | | ** PREVIOUS NOTE ** | | | PLEASE BE SURE ALL SHEETS | | | CONTAIN THE PRINTED NAME AND THE | | | SIGNATURE OF THE PERSON TAKING | | | RESPONSIBILITY FOR PLANS AND DESIGN. | | | | | | ** NEW NOTE ** | | | 1)NOTE: PLEASE SEE CALCS SHOW CITY OF | | | "PALM BEACH GARDENS"? PLEASE ADJUST. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW., IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-04-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-04-12 |
Time |
18:11 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-04-12 |
Time |
18:11 |
Sent To |
M |
|
| Notes |
| 2006-04-12 00:00:00 | ******** UNSAT *********** | | | | | | 1) NOTE: PLEASE PROVIDE A SCHEDULE FOR | | | THE TRANSFER PANEL FOR INTENDED LOADS | | | AND PLEASE CLARIFY AHU LOAD. UNLESS | | | AUTOMATIC LOAD SHEDDING IS DETAILED AND | | | PROVIDED, AHU HEAT SHALL BE FIGURED AT | | | 100%. | | | 220, 702.5 | | | PLEASE KNOW, MANY OF THE PRE-WIRED | | | PANELS DO NOT CONTAIN THE OCP WHICH MAY | | | BE NEEDED FOR THE INTENDED LOADS AND | | | ALTERATION OF LISTED EQUIPMENT IS NOT | | | PERMITTED. | | | | | | 2) NOTE: PLEASE RE-DRAWN RISER WITH OUT | | | HAND DRAWN AND WHITE-OUT CHANGES. PLEASE | | | INCLUDE DISCONNECTING MEANS FROM | | | GENERATOR TO MAIN HOUSE AND THIS | | | DISCONNECTING MEANS SHALL BE GROUPED | | | WITH THE EXISTING MAIN. | | | 225.31-225.39. | | | | | | 3) NOTE: PLEASE INCLUDE LOCATIONS OF ALL | | | SERVICE EQUIPMENT AS SHOWN ON RISER ON | | | THE PROVIDED SITE LAYOUT. PLEASE SEE | | | PLANS, AT CURRENT TIME ONLY INDICATE THE | | | ATS ON THE OUTSIDE OF DWELLING. | | | 215.5 | | | | | | 4) NOTE: PLEASE SUBMIT SPECS FOR ATS/ | | | PANEL BEING INSTALLED. | | | PLEASE INDICATE THE AIC RAITNG FOR ATS. | | | NFPA-110, 6.5.2, NEC 110.9 | | | 215.5 | | | | | | 5) NOTE: PLEASE BE SURE ALL SHEETS | | | CONTAIN THE PRINTED NAME AND THE | | | SIGNATURE OF THE PERSON TAKING | | | RESPONSIBILITY FOR PLANS AND DESIGN. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW., IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2006-04-13 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-04-13 |
Time |
14:25 |
Rev Time |
0.15 |
| Received By |
mperson |
Date |
2006-04-13 |
Time |
14:25 |
Sent To |
B |
|
| Notes |
| 2006-04-13 00:00:00 | NOTE: GAS PERMIT REQUIRED. GAS | | | CONTRACTOR TO SUBMIT PLANS WITH PERMIT | | | APPLICATION. ALL GAS INSPECTIONS TO BE | | | COMPLETE BEFORE FINAL GEN/RES | | | INSPECTION. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-09-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-09 |
Time |
19:08 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-09 |
Time |
19:08 |
Sent To |
E |
|
| Notes |
| 2006-09-09 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-05-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-23 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-23 |
Time |
14:38 |
Sent To |
E |
|
| Notes |
| 2006-05-23 00:00:00 | TO "E" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-05-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-02 |
Time |
10:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-02 |
Time |
10:50 |
Sent To |
E |
|
| Notes |
| 2006-05-02 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-04-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-26 |
Time |
12:35 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-26 |
Time |
12:35 |
Sent To |
Z |
|
| Notes |
| 2006-04-26 00:00:00 | TO "Z" BOX/RESUB-NEW SHEETS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-04-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-10 |
Time |
16:35 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-10 |
Time |
16:35 |
Sent To |
E |
|
| Notes |
| 2006-04-10 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-04-14 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-04-14 |
Time |
16:24 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-04-06 |
Time |
09:36 |
Sent To |
|
|
| Notes |
| 2006-04-06 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2006-05-10 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-05-10 |
Time |
10:53 |
Rev Time |
0.10 |
| Received By |
tgordon |
Date |
2006-05-10 |
Time |
10:53 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2006-04-13 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-04-13 |
Time |
08:25 |
Rev Time |
0.15 |
| Received By |
tgordon |
Date |
2006-04-13 |
Time |
08:25 |
Sent To |
P |
|
| Notes |
| 2006-04-13 00:00:00 | *** PROVISO *** | | | 1)GENERATOR EXHUST MUST BE TEN FEET AWAY | | | FROM ANY BUILDING OPENINGS (WINDOWS, | | | DOORS, ROOF & EAVE VENTS), AND TEN FEET | | | AWAY FROM ADJECENT BUILDING OPENS. PER | | | 2004 FBC/M 401.5.1 . | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2006-04-13 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-04-13 |
Time |
14:25 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2006-04-13 |
Time |
14:25 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2006-04-30 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-04-30 |
Time |
17:25 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-04-30 |
Time |
17:25 |
Sent To |
I |
|
| Notes |
| 2006-04-30 00:00:00 | NOTE: GENERATOR CAN ONLY ENCROACH 4FT | | | INTO A SETBACK. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2006-04-10 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-04-10 |
Time |
08:17 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-04-10 |
Time |
08:17 |
Sent To |
I |
|
| Notes |
|
|