Plan Review Details - Permit 06031561
Plan Review Stops For Permit 06031561
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2006-08-10 Cont ID  
Sent By mjacobs Date 2006-08-10 Time 15:53 Rev Time 0.00
Received By mjacobs Date 2006-08-10 Time 09:12 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-05-01 Cont ID  
Sent By mjacobs Date 2006-05-01 Time 08:09 Rev Time 0.00
Received By mjacobs Date 2006-04-25 Time 11:33 Sent To PC
Notes
2006-04-25 00:00:001) 110.2* W. P. B. ADMINISTRATIVE CODE,
 INFORMATION THAT IS REQUIRED FOR RECORD
 KEEPING & FOR CERTIFICATE OF OCCUPANCY:
 A) THE EDITION OFTHE CODE UNDER WHICH
 THE PERMIT WAS ISSUED.
 B) THE USE AND OCCUPANCY, IN ACCORDANCE
 WITH THE PROVISIONS OF CHAPTER 3.
 C) THE TYPE OF CONSTRUCTION AS DEFINED
 IN CHAPTER 6, TABLE 601.
 D) THE DESIGN OCCUPANT LOAD, SEE 1004.
  
 2) 2004 FL. BLD CODE 1603.1.4 THE
 FOLLOWING INFORMATION RELATED TO WIND
 SHALL BE SHOWN ON THE CONSTRUCTION
 DRAWINGS,
 1)- BASIC WIND SPEED, MPH
 2)- WIND IMPORTANCE FACTOR, & BUILDING
 CATEGORY
 3)- WIND EXPOSURE
 4)- INTERNAL PRESSURE COEFFICIENT,
 5)- COMPONENTS & CLADDING, THE DESIGN
 WIND PRESSURES IN TERMS OF PSF.
 NOTE: THE ASCE STANDARD UNDER THE NEW
 CODE IS ASCE 7-02. SEE FBC. 35.6R
  
 3) 104.6.5 BUILDING PERMIT VALUATION. IF
 IN THE OPINION OF THE BUILDING OFFICIAL
 THE CLAIMED VALUATION OF BUILDING,
 ALTERATION, STRUCTURE, ELECTRICAL, GAS,
 MECHANICAL OR PLUMBING SYSTEMS APPEARS
 TO BE UNDERESTIMATED ON THE APPLICATION,
 THE PERMIT SHALL BE DENIED, UNLESS THE
 APPLICANT CAN SHOW DETAILED ESTIMATES
 AND/OR BONA FIDED SIGNED CONTRACTS
 (EXCLUDING LAND VALUE) TO MEET THE
 APPROVAL OF THE BUILDING OFFICIAL. FOR
 PERMITTING PURPOSES, VALUATION FOR
 BUILDINGS AND SYSTEMS SHALL BE FOUND IN
 MARSHALL AND SWIFT OR THE SOUTHERN
 BUILDING CODE CONGRESS INTERNATIONAL
 VALUATION TABLES, LATEST EDITION, AND
 SHALL BE BASED ON TOTAL REPLACEMENT
 VALUE TO INCLUDE STRUCTURAL, ELECTRIC,
 PLUMBING, MECHAN-
 ICAL, INTERIOR FINISH, NORMAL SITE WORK
 (EXCAVATION AND BACKFILL FOR BUILDINGS)
 ARCHITECTURAL AND DESIGN FEES, OVERHEAD
 AND PROFIT, EXCLUDING ONLY LAND VALUE.
 ATTIC ACCESS OPENING SHALL BE NO LESS
 THAN 30" X 22" AS PER 2001 FBC(M) 306.3
  
 4) FL ENERGY EFFICIENCY CODE 400.ABCD.2
 THE BUILDING'S OWNER, THE OWNER'S
 ARCHITECT, OR OTHER AUTHORIZED AGENT
 LEGALLY DESIGNATED BY THE OWNER SHALL
 CERTIFY TO THE BUILDING OFFICIAL THAT
 THE BUILDING IS IN COMPLIANCE WITH THE
 ENERGY EFFICIENTY CODE.
  
 5) THE DISCREPTION ON THE PERMIT
 APPLICATION IS FOR ROOFING ONLY.
 HOWEVER, THE DRAWINGS INDICATE OTHER
 WORK WILL BE CARRIED OUT AT THIS
 LOCATION. NOTE: IF OTHER WORK WILL BE
 CARRIED OUT AT THIS LOCATION THE PERMIT
 APPLICATION WILL HAVE TO BE ALTERED TO
 MATCH THE WORK. THE PROJECT SHOULD BE
 DESCRIBE IN DETAIL.
  
 6) THE PLWOOD ON THE OVER HANG AT THE
 FRONT ENTRY HAS TO BE 5/8". ALSO SEE
 FBC. R503.2.1.1 AND TABLE 503.1.
  
 7) WPB ADMIN CODE 106.3* PRODUCT
 APPROVALS. THOSE PRODUCT WHICH ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL. SUBMIT
 PRODUCT APPROVALS FOR THE WINDOWS/DOORS
 ETC. ALL PRODUCTS WHICH ARE APPROVED BY
 THE STATE, SHOULD HAVE THE STATE COVER
 SHEET WITH THE FL# TO MATCH.
  
 8) WHEN THE 4" KNEEWALL IS MENTIONED, IS
 THE 4" THE WIDTH OF THE FRAMING MEMBERS?
 PLEASE CLARIFY. SHOW A CROSS SECTION OF
 THE BUILT-UP FLOOR DECK INCLUDING ALL
 STRUCTURAC MATERIALS.SEE SEC. R504.2.2
 FOR MOISTURE BARRIER.
  
 9) 481.221SEALS; DISPLAY OF
 CERTIFICATE NUMBER.--
 (3)THE BOARD SHALL ADOPT A RULE
 PRESCRIBING THE DISTINCTLY DIFFERENT
 SEALS TO BE USED BY REGISTERED INTERIOR
 DESIGNERS HOLDING VALID CERTIFICATES OF
 REGISTRATION. EACH REGISTERED INTERIOR
 DESIGNER SHALL OBTAIN A SEAL AS
 PRESCRIBED BY THE BOARD, AND ALL
 DRAWINGS, PLANS, SPECIFICATIONS, OR
 REPORTS PREPARED OR ISSUED BY THE
 REGISTERED INTERIOR DESIGNER AND BEING
 FILED FOR PUBLIC RECORD SHALL BEAR THE
 SIGNATURE AND SEAL OF THE REGISTERED
 INTERIOR DESIGNER WHO PREPARED OR
 APPROVED THE DOCUMENT AND THE DATE ON
 WHICH THEY WERE SEALED. THE SIGNATURE,
 DATE, AND SEAL SHALL BE EVIDENCE OF THE
 AUTHENTICITY OF THAT TO WHICH THEY ARE
 AFFIXED. FINAL PLANS, SPECIFICATIONS, OR
 REPORTS PREPARED OR ISSUED BY A
 REGISTERED INTERIOR DESIGNER MAY BE
 TRANSMITTED ELECTRONICALLY AND MAY BE
 SIGNED BY THE REGISTERED INTERIOR
 DESIGNER, DATED, AND SEALED
 ELECTRONICALLY WITH THE SEAL IN
 ACCORDANCE WITH SS. 668.001-668.006.
  
 10)PRE-INSPECTION IS REQUIRED FOR THE
 SIDING WHICH WILL BE REPLACED WITH
 WIRELATH & STUCCO.
  
  
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 TEL:(561)805-6726
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 4 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By dpalmer Date 2007-02-13 Time 12:27 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-09-22 Cont ID  
Sent By dpalmer Date 2006-09-22 Time 07:19 Rev Time 0.00
Received By dpalmer Date 2006-09-22 Time 07:19 Sent To M
Notes
2006-09-22 00:00:00****** PROVISO *******
  
  
 ***** REVISION NEEDED BEFORE ROUGH *****
  
  
 1) NOTE: PLEASE SEE MISSING PANEL
 SCHEDULE INDICATING ALL MINIMUM REQUIRED
 BRANCH CIRCUITS SHOWING THE OCP AND MIN
 CONDUCTOR SIZES PER 240.4,310.16,408.4
 **REQUESTED ON PREVIOUS REVIEWS**
  
 2) NOTE: PLEASE SEE BATH GFI MUST BE 20A
 #12 MIN PER 210.52D,210.11C3
 NOT INDICATED AT THIS TIME.
 **REQUESTED ON PREVIOUS REVIEWS**
  
 3) NOTE: PLEASE SEE 110.26 AS THE
 DISCONNECT FOR THE CU IS SHOWN BEHIND
 UNIT.
  
 4) NOTE: PLEASE SEE MISSING LAUNDRY
 CIRCUIT REQUIED PER 210.52F,210.11C2,
 220.16.
 ** REQUESTED ON PREVIOUS REVIEWS**
  
 PLEASE REVISE AND SUBMIT THE ABOVE ALONG
 WITH AMY OTHER REVISIONS BEFORE THE
 ROUGH ELECTRICAL INSPECTION IS CALLED
 IN.
 PLEASE KNOW, THE NEW REVISED STAMPED
 PLANS AFTER BEING REVIEWED, SHALL BE ON
 SITE FOR THE ROUGH INSPECTION.
  
 IF THERE ARE ANY QUESTIONS, PLEASE DO
 NOT HESITATE IN CONTACTING THIS OFFICE.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2006-08-06 Cont ID  
Sent By dpalmer Date 2006-08-06 Time 11:13 Rev Time 0.00
Received By dpalmer Date 2006-08-06 Time 10:48 Sent To M
Notes
2006-08-06 00:00:00***** UNSAT 2ND REVIEW *******
  
 ** PLEASE SEE SOME COMMENTS FROM
 PREVIOUS REVIEW.
  
  
 1) NOTE: OK.
  
 2) NOTE: OK.
  
 3) NOTE: OK, AS NO ARCHITECT IS BEING
 SHOWN ON TITLE BLOCKS FOR ELECTRICLA
 PLANS. PLANS ARE BEING DONE BY A
 DESIGNER/DRAFTMANS.
  
 4) NOTE: OK.
  
 5) NOTE: OK.
  
 6) NOTE: OK.
  
 7) NOTE: OK. METER SHOWN IN FRONT OF THE
 PANEL 110.26
  
 ** PREVIOUS REVIEW NOTE **
 PLEASE SEE PLANS MENTIONS NEW
 PANEL BEING LOCATED OUTSIDE , HOWEVER
 PLANS ONLY SHOW THEMETER. PLEASE SHOW
 THE OUTDOOR PANEL.
  
 8) NOTE: OK.
  
 9) NOTE: OK.
  
 10) NOTE: OK.
  
 11) NOTE: NO, UNCLEAR AS THERE IS A GFI
 CIRCUIT SHOWN, BUT NOT SURE OF THIS IS
 FOR THE BATHRM?
  
 ** PREVIOUS REVIEW NOTE **
 PLEASE SEE MISSING REQUIRED
 DEDICATED BATH CIRCUIT PER 210.52D,
 210.11C3, MUST BE 20A AND #12.
  
 12) NOTE: NO, PLEASE SEE NOTE ON
 SCHEDULE NOW MENTIONS WASHER "OPT"
 PLEASE KNOW A LAUNDRY/WASHER CIRCUIT IS
 REQUIRED.210.11C2,220.16
  
 ** PREVIOUS REVIEW NOTE **
 PLEASE VERIFY WASHER AND DRYER AS PLANS
 SHOW A STACK UNIT AND PANEL/LOADS CALCS
 SHOWS INDIVIDUAL UNITS?
  
 13) NOTE: OK.
  
 14) NOTE:NO, PLEASE SEE REDLINED
 PLANS. PLEASE SEE NEW NOTE FOR KIT.
  
 ** PREVIOUS REVIEW NOTE **
 PLEASE SEE SOME MISSING
 RECEPTS PER 210.52 ONLY MISSING A FEW,
 THESE ARE REDLINED ON PLANS AT LOCATIONS
 NEEDED.
  
 15) NOTE: OK, SEEMS TO BE A CLOSET?
  
 16) NOTE: OK.
  
 17) NOTE: OK.
  
 18) NOTE:NO, PLEASE SEE ONLY THE 2002
 NEC WAS ADDED.
  
 ** PREVIOUS REVIEW NOTE **
 PLEASE SHOULD NOTE THE CURRENT
 CODE IN EFFECT. 2002 NEC , 2002 NFPA-72
  
 19) NOTE:NO, COULD NOT LOCATE THIS ON
 RISER OR PLANS.
  
 ** PREVIOUS REVIEW NOTE **
 PLEASE SUBMIT THE AIC RATINGS
 FOR NEW SERVICE EQUIPMENT/ MAINS. PER
 110.9/215.5
  
 ** NEW NOTES **
  
 20) NOTE: PLEASE SEE MISSING COUNTER
 SPACE GFI REQUIRED PER 210.52C1,210.8A6
  
 21) NOTE: PLEASE SEE MISSING RECEPT FOR
 DISPOAL AND DISHWASHER. PLEASE SEE IF
 THESE ARE GOING TO BE FED FROM THE SAME
 RECEPT, THEN A 2-POLE BRKR WILL BE
 REQUIRED. 210.4B
 PLEASE SHOW ON PLANS.
  
 22) NOTE: PLEASE SEE THE ONLY "PANEL
 SCHEDULE " BEING SUBMITTED IS ACTUALLY
 PART OF THE LOAD CALCULATIONS. PLEASE
 KNOW, ONE WILL BE REQUIRED SHOWING ALL
 UNLESS THE LOAD CALCS ARE SET UP TO
 INDICATE ALL.
 408.4, FBC 106.1.2
  
  
 ** WHEN RE-SUBMITTING PLANS, PLEASE BE
 SURE TO COMPLETELY REMOVE ALL OLD/VOIDED
 SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO COMPLETE SETS FOR REVIEW AND
 STAMPING.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE IN CONTACTING
 THIS OFFICE.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-04-07 Cont ID  
Sent By dpalmer Date 2006-04-07 Time 08:19 Rev Time 0.00
Received By dpalmer Date 2006-04-07 Time 07:04 Sent To M
Notes
2006-04-07 00:00:00*************** UNSAT ***************
  
  
 1) NOTE: PLEASE SEE AN OWNER/ BUILDER
 PERMIT IS BEING APPLIED FOR , HOWEVER IT
 DOES APPEAR APPLICATION QUALIFIES FOR
 THE EXEMPTIONS UNDER FS 489.
 PLEASE SEE ATTACHED PRINT OUT FROM PALM
 BEACH COUNTY PROPERTY APPR'S OFFICE
 WHICH INDICATES NUMEROUS PROPERITES
 UNDER OWNERS INFORMATION INCLUDING WHAT
 IS BEING A USED A A PRIMARY RESIDENCE
 LOCATED IN PALM BEACH COUNTY.
 PLEASE ALSO KNOW, THIS OFFICE WILL
 VERIFY WITH THE OTHER JURISDICTIONS OF
 OWNED PROPERTIES TO ANY PERMITTED WORK
 FOR VERIFICATION OF O/B QUALIFICATION.
 ** IF IT IS THE INTEND TO LEASE/RENT OR
 SELL PROPERTY W/IN TIME LIMITS,OR NOT TO
 USE THIS PROPERTY FOR OWN USE AND
 OCCUPANCY,IT IS ADVISABLE TO OBTAIN A
 CONTRACTOR FOR SUCH PERMITTED WORK.
  
 2) NOTE: PLEASE SEE SCOPE PF WORK
 MENTIONED ON APPLICATION AND SCOPE ON
 PLANS DO NOT CORRELATE.
 PLEASE ALSO SEE VALUE SHALL BE ADJUSTED
 FOR COMPLETE SCOPE PF REMODEL. THIS
 SHALL INCLUDE ALL LABOR AND MATERIALS.
 FBC ADMINISTRATIVE SECTION 108.3.
 PLEASE KNOW,IF AN APPROPRIATE VALUE IS
 NOT ADJUSTED, IT WILL BE ADJUSTED BY
 THIS OFFICE BASED ON FAIR MARKET VALUES
 SET FORTH IN THE FBC.
  
 3) NOTE: PLEASE SEE PLANS MUST BE SIGNED
 , DATED AND SEALED BY THE ARCHITECT AS
 RECORD ON TITLE BLOCK OF SAID PLANS.
 PLEASE ALSO SEE BUILDING REVIEW COMMENTS
 WITH RESPECT TO PLANS BEING SIGNED AND
 SEALED BY AN ARCHITECT OR ENGINEER FOR
 SCOPE OF WORK.
 FS 481.221, FBC 106.3.4.3
  
 4) NOTE: PLEASE SEE MISSING INFORMATION
 REQUIRED ON TITLE BLOCK(S) AS REQUIRED
 UNDER FLORIDA ADMINISTRATIVE CODE
 61G1-16.004.
 PLEASE ALSO SEE FS 481.219
 MISSING CERITIFICATE OF AUTHORIZATION
 NUMBER.
  
 5) NOTE: PLEASE SEE FBC FOR EXISTING
 BUILDINS R313 WHICH REQUIRES ALL SD'S TO
 BE BROUGHT UP TO CODE FOR THIS LEVEL OF
 ALTERATION.
 PLEASE KNOW, ALL ARE TO BE WIRED
 INLINE/120V.
 PLEASE INDICATE ALL LOCATION PER NFPA-72
 11.5.1.1
 ** PLEASE SEE THERE SEEMS TO BE A
 PARTIAL "RECEPT" SYMBOL LOCATED NEXT TO
 THE SD'S SHOWN, HOWEVER THIS SYMBOL
 COULD NOT BE LOCATED ON SCHEDULE?
  
 6) NOTE: PLEASE SEE A MIN OF TWO GRND
 RODS WIL BE REQUIRED. 250.50,250.56
  
 7) NOTE: PLEASE SEE PLANS MENTIONS NEW
 PANEL BEING LOCATED OUTSIDE , HOWEVER
 PLANS ONLY SHOW THEMETER. PLEASE SHOW
 THE OUTDOOR PANEL.
  
 8) NOTE: PLEASE VERIFY KW RATING OF
 RANGE AS THIS SEEMS VERY LOW FOR A MIN
 KW OF A RANGE.
 PLEASE ALSO SEE LOADS FOR RANGES AT A
 MIN IN 220.19.
  
 9) NOTE: PLEASE SEE NEC 220.31, FOR MIN
 LOADS FOR A/C SYSTEM. PLEASE SEE LOADS
 AS SHOWN DO NOT CORRELATE WITH ANY LOAD
 CALCUALTIONS INNEC. SHOWS A 65%
 DE-RATING FOR BOTH THE CU AND AHU ???
 PLEASE SEE AHU ALSO SHOWS 8KW AND 10KW?
 WHICH ONE?
 215.5
  
 10) NOTE: PLEASE ALSO ADJUST MIN OCP FOR
 AHU PER 424.3B IF AHU HEAT IS 10KW.
 (125%).
  
 11) NOTE: PLEASE SEE MISSING REQUIRED
 DEDICATED BATH CIRCUIT PER 210.52D,
 210.11C3, MUST BE 20A AND #12.
  
 12) NOTE: PLEASE VERIFY WASHER AND
 DRYER, AS PLANS SHOW A STACK UNIT, AND
 PANEL/LOAD CALCS SHOWS INDIVIDUAL UNITS?
 215.5
  
 13) NOTE: PLEASE SEE MISSING FRONT AND
 REAR GFI PER 210.52E, 210.8A
  
 14) NOTE: PLEASE SEE SOME MISSING
 RECEPTS PER 210.52 ONLY MISSING A FEW,
 THESE ARE REDLINED ON PLANS AT LOCATIONS
 NEEDED.
  
 15) NOTE: PLEASE VERIFY NEW OR EXISTING
 MEANS OF EGRESS LIGHTING CONTROL FOR
 DOOR LEADING TO OUTSIDE MEANS OF EGRESS
 FROM EXISTIGN BEDRM.
 210.70, LS 101 7.8
  
 16) NOTE: PLEASE SEE PLANS MENTIOSN ARC
 FAULT PROTECTION FOR RECEPTS ONLY.
 PLEASE SEE PLANS ARE TO BE DESIGNED
 UNDER THE 2002 NEC/ NFPA-70. PLEASE SEE
 210.12B WHICH REQUIRESALL "OUTLETS" IN
 BEDRMS TO BE AFCI PROTECTED.
  
 17) NOTE: PLEASE SEE MECHANICAL REVIEW
 COMMENTS WITH RESPECT TO NEW OR EXISTING
 EXHAUST FAN IN BATHRM.
 ** THIS WILL BE A MECHANICAL REVIEW
 COMMENT, HOWEVER MAY AFFECT ELECTRICAL
 PLANS.
  
 18) NOTE: PLEASE SHOULD NOTE THE CURRENT
 CODE IN EFFECT. 2002 NEC , 2002 NFPA-72
  
 19) NOTE: PLEASE SUBMIT THE AIC RATINGS
 FOR NEW SERVICE EQUIPMENT/ MAINS. PER
 110.9/215.5
  
 ** WHEN RE-SUBMITTING PLANS, PLEASE BE
 SURE TO COMPLETELY REMOVE ALL OLD/VOIDED
 SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO COMPLETE SETS FOR REVIEW AND
 STAMPING.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE IN CONTACTING
 THIS OFFICE.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date   Cont ID  
Sent By   Date 2007-02-12 Time   Rev Time 0.00
Received By adarroug Date 2007-02-12 Time 14:01 Sent To  
Notes
2007-02-12 14:01:51TO "DPALMER" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-09-18 Cont ID  
Sent By adarroug Date 2006-09-18 Time 14:18 Rev Time 0.00
Received By adarroug Date 2006-09-18 Time 14:18 Sent To E
Notes
2006-09-18 00:00:00TO "DPALMER" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-08-02 Cont ID  
Sent By adarroug Date 2006-08-02 Time 09:09 Rev Time 0.00
Received By adarroug Date 2006-08-02 Time 09:09 Sent To E
Notes
2006-08-02 00:00:00TO "DPALMER" DESK/RESUB AND CHANGE OF
 CONTRACTOR

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-07-24 Cont ID  
Sent By adarroug Date 2006-07-24 Time 13:11 Rev Time 0.00
Received By adarroug Date 2006-07-24 Time 13:11 Sent To Z
Notes
2006-07-24 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-04-06 Cont ID  
Sent By adarroug Date 2006-04-06 Time 10:26 Rev Time 0.00
Received By adarroug Date 2006-04-06 Time 10:26 Sent To E
Notes
2006-04-06 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2006-05-01 Time   Rev Time 0.00
Received By adarroug Date 2006-03-31 Time 15:41 Sent To  
Notes
2006-03-31 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2006-10-04 Cont ID  
Sent By tgordon Date 2006-10-04 Time 15:10 Rev Time 2.30
Received By tgordon Date 2006-10-04 Time 15:10 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2006-09-27 Cont ID  
Sent By tgordon Date 2006-09-27 Time 11:44 Rev Time 1.15
Received By tgordon Date 2006-09-27 Time 11:44 Sent To B
Notes
2006-09-27 00:00:00*** DENIED ***
 1) PLEASE SEE 2004 FBC 13-101.5.1
 EXISTING BUILDINGS EXCEPT THOSE
 CONSIDERED RENOVATED BUILDINGS. THIS
 PERMIT IS FOR A RENOVATED BUILDING .
  
 2) AS REQUESTED IN LAST REVIEW 8-7-06.
 (1) ENERGY CALCULATIONS NEED TO BE
 SIGNED BY OWNER/AGENT ALSO, PER 2004 FBC
 13-600.3.ABC.2 .
  
 (2) PLEASE SUBMIT MANUAL D
 CALCULATIONS FOR RESIDENTIAL DUCT
 DESIGN, PER 2004 FBC/R M1601.1 AND FBC
 13-610.1.ABC.1 . (10" SUPPLY TRUNK LINE
 APPEARS TO SMALL FOR 955 CFM'S). PLEASE
 BE ADVISED THERE ARE NO EXEMPTIONS
 REGARDING MANUAL D CAL'S. IN THE 2004
 FBC THAT I KNOW OF, AND THAT I DID NOT
 REQUEST A MANUAL J CAL. BE SUBMITTED IN
 MY LAST REVIEW.
  
 (3) ALL INFORMATION, DRAWINGS,
 SPECIFICATIONS AND ACCOMPANYING DATA
 SHALL BEAR THE NAME AND SIGNATURE OF THE
 PERSON RESPONSIBLE FOR THE DESIGN. PER
 FBC 104.2.1 . (NO STAMPS).
  
 3)SEE ATTACHED NOTICE FS 553.80(2)(B)
 REGARDING FOUR TIMES THE FEE.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2006-08-07 Cont ID  
Sent By tgordon Date 2006-08-07 Time 09:13 Rev Time 0.30
Received By tgordon Date 2006-08-07 Time 09:13 Sent To P
Notes
2006-08-07 00:00:00*** DENIED ***
 1) ENERGY CALCULATIONS NEED TO BE SIGNED
 BY OWNER/AGENT, PER 2004 FBC
 13-600.3.ABC.2 .
  
 2) PLEASE SUBMIT MANUAL D CALCULATIONS
 FOR RESIDENTIAL DUCT DESIGN, PER 2004
 FBC/R M1601.1 AND FBC 13-610.1.ABC.1 .
 (10" SUPPLY TRUNK LINE APPEARS TO SMALL)
  
 3) ALL INFORMATION, DRAWINGS,
 SPECIFICATIONS AND ACCOMPANYING DATA
 SHALL BEAR THE NAME AND SIGNATURE OF THE
 PERSON RESPONSIBLE FOR THE DESIGN. PER
 FBC 104.2.1 .
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2006-04-07 Cont ID  
Sent By tgordon Date 2006-04-07 Time 09:52 Rev Time 0.30
Received By tgordon Date 2006-04-07 Time 09:52 Sent To P
Notes
2006-04-07 00:00:00*** NOTE ***
 1) A MECHANICAL PERMIT WILL BE REQUIRED.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop P PLUMBING
Rev No 2 Status N Date 2006-08-10 Cont ID  
Sent By jleech Date 2006-08-10 Time 08:05 Rev Time 0.00
Received By jleech Date 2006-08-10 Time 08:05 Sent To B
Notes
2006-08-10 00:00:00NO PLUMBING SHOWN. PLANS TO BE SUBMITED
 WITH PLUMBING APPLICATION.

Review Stop P PLUMBING
Rev No 1 Status F Date 2006-04-07 Cont ID  
Sent By jleech Date 2006-04-07 Time 14:58 Rev Time 0.00
Received By jleech Date 2006-04-07 Time 14:44 Sent To B
Notes
2006-04-07 00:00:00NOT ENOUGH INFORMATION TO DO A PLUMBING
 PLAN REVIEW. PLEASE SUBMIT A SANITARY
 RISER DIAGRAM SHOWING WORK TO BE DONE.
 SEE FBC-2004 CHAPTER 1 SEC.106.3.5.4(9)
 SIZE ALL PIPE TO MEET MINUMUM CODE
 REQUIREMENT SEE FBC-2004 PLUMBING.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop Z ZONING
Rev No 3 Status P Date 2006-08-01 Cont ID  
Sent By mmclean Date 2006-08-01 Time 11:21 Rev Time 0.00
Received By mmclean Date 2006-08-01 Time 11:20 Sent To I
Notes
2006-08-01 00:00:00NOTE: THE PROPOSED A/C SHALL NOT BE
 CLOSER THAN 2FT FROM REAR PROPERTY LINE.

Review Stop Z ZONING
Rev No 2 Status F Date 2006-05-04 Cont ID  
Sent By mmclean Date 2006-05-04 Time 15:30 Rev Time 0.00
Received By mmclean Date 2006-05-04 Time 15:30 Sent To I
Notes
2006-05-04 00:00:00DENIED,
 1. MUST SHOW THE PROPOSED WORK (NEW
 RAISED CONC. ENTRY, ETC) ON TWO COPY OF
 CURRENT SURVEY, WITH SETBACKS.
 2. MUST SHOW THE EXISTING CONC. STOOP ON
 THE TWO COPY OF SURVEY (WITH SETBACKS)
 3. MUST SHOW THE NEW A/C UNIT ON SURVEY
 WITH SETBACKS.
  
 NOTE: MUST PULL A SEPERATE PERMIT FOR
 WALL WITH EASEMENT APPROVAL FROM THE
 CITY OF WEST PALM BEACH UTILITY DEPT AND
 TWO COPY OF WALL DETAIL.
  
 SURVEY PROVIDED DOES NOT SHOW THE
 PROPOSED WORK.
  
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720

Review Stop Z ZONING
Rev No 1 Status F Date 2006-04-05 Cont ID  
Sent By mmclean Date 2006-04-05 Time 17:46 Rev Time 0.00
Received By mmclean Date 2006-04-05 Time 17:46 Sent To I
Notes
2006-04-05 00:00:00DENIED,
 1. NEED TO SHOW THE PROPOSED WORK WITH
 SETBACKS ON TWO COPY OF SURVEY.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720