Plan Review Details - Permit 06031303
Plan Review Stops For Permit 06031303
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2006-05-01 Cont ID  
Sent By lursu Date 2006-05-01 Time 13:40 Rev Time 0.00
Received By lursu Date 2006-05-01 Time 13:40 Sent To  
Notes
2006-05-01 00:00:00NEW ADDRESS:3808 RUSSELL AVE WAS
 ASSIGNED TO THIS VACANT LOT AND A LETTER
 OF NOTIFICATION WAS SENT ON 03/31/06

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2006-06-08 Cont ID  
Sent By alange Date 2006-06-08 Time 09:04 Rev Time 1.00
Received By alange Date 2006-06-08 Time 09:04 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-04-25 Cont ID  
Sent By alange Date 2006-04-25 Time 09:03 Rev Time 2.50
Received By alange Date 2006-04-25 Time 09:03 Sent To AD
Notes
2006-04-25 00:00:00 
 DENIED
  
  
 1. 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE
 RE-RECORDED IF THE DESCRIBED IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 3.BASED ON ICC BUILDING VALUATION DATA
 THE PERMIT VALUE HAS BEEN REVISED TO
 $135,490.00.ADDITIONAL PERMIT FEES ARE
 DUE.
  
 4.THOSE PRODUCT APPROVALS WHICH ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.WPB
 AMENDMENT TO FBC 106.3.3.
  
 5.SUBMIT TWO SETS OF TRUSS DRAWINGS
 FOR REVIEW PER 2004 FBC R-802.10.1
  
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. SUBMIT ONE COPY OF
 OLD PAGES FOR REFERENCE. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET
 OR SPECIFICATION PAGE WHERE THE CHANGES
 CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 ART LANGE
 CONSTRUCTION SERVICES DEPARTMENT
 BUILDING PLANS EXAMINER
 561-805-6672
  
  

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2006-09-27 Cont ID  
Sent By dpalmer Date 2006-09-27 Time 19:24 Rev Time 0.00
Received By dpalmer Date 2006-09-27 Time 19:04 Sent To PC
Notes
2006-09-27 00:00:00REDLINED #14 SHOWN ON 20A BRKR FOR THE
 GDO.
 240.4, 310.16, REQUIRES #12 MIN.
  
 A/C COMP SHOWN FOR THE 100% LOAD FOR
 A/C, HOWEVER IS A MISPRINT FOR THE AHU
 WHICH IS THE LARGEST. 220.20
  
 NO REV NEEDED.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-08-03 Cont ID  
Sent By dpalmer Date 2006-08-03 Time 12:26 Rev Time 0.00
Received By dpalmer Date 2006-08-03 Time 12:26 Sent To  
Notes
2006-08-03 00:00:00REVISED PANEL SCHEDULE TO SHOW WIRE, NO
 CONDUIT.
 REVISED OCP FOR AHU.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-06-02 Cont ID  
Sent By dpalmer Date 2006-06-02 Time 16:25 Rev Time 0.00
Received By dpalmer Date 2006-06-02 Time 16:25 Sent To M
Notes
2006-06-02 00:00:00REDLINED PLANS.
  
 MIN OCP FOR AHU TO BE 125%. 424.3B

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-03-31 Cont ID  
Sent By dpalmer Date 2006-03-31 Time 07:31 Rev Time 0.00
Received By dpalmer Date 2006-03-31 Time 07:02 Sent To M
Notes
2006-03-31 00:00:00********* UNSAT ***********
  
 1)NOTE: PLEASE SEE NOTES MENTIONS WORK
 PER "PALM BEACH COUNTY", PLEASE SEE
 SCOPE OF WORK IS LOCATED IN THE CITY OF
 WEST PALM BEACH.
 PLEASE ADJUST
 PLEASE ALSO KNOW, ONCE ALL REVIEW BY
 ADDRESSING DEPARTMENT IS DONE, AN
 ADDRESS FOR THIS PROJECT WILL BE ISSUED.
 PLEASE ADJUST TITLE BLOCKS TO INCLUDE
 THE NEW ADDRESS. FAC 61G1-16.004
  
 2) NOTE: PLEASE CORRELATE A/C HEAT
 LOADS. MECH PLANS INDICATE 8KW,
 ELECTRICAL PLANS INDICATE 10 KW?
 PLEASE ADJUST AS NEEDED.
 ** PLEASE ALSO SEE LOAD CALCULATIONS AS
 THE LOADS ARE SHOWN AS THE HIGHER LOAD
 WHICH IS THE AHU (10KW), HOWEVER THE
 IDENTIFICATION IS NOTED AS THE A/C
 COMP.?
 PLEASE ADJUST. THIS HAS BEEN REDLINED ON
 OTHER PLANS AND SEEMS TO BE A MISPRINT
 IN PLANS.
  
 3) NOTE: PLEASE SEE BATH CIRCUIT(S) ARE
 REQUIRED TO BE 20A, #12,
 210.52D,210.11C3
 (SHOWN AS 15A #14)
  
 4) NOTE: PLEASE SHOW DISCONNECT FOR AHU.
 440.11
  
 5) NOTE: PLEASE SEE RISER SHOWS A MAIN
 DISCONNECT OUTSIDE , HOWEVER PLANS ONLY
 SHOW THE 200A METER.
  
 PLANS ARE GENERALLY IN GOOD SHAPE,
 HOWEVER THEY ARE COMING BACK FOR OTHER
 COMMENTS AND THE ABOVE SHOULD BE
 CORRECTED AT THIS TIME.
  
  
 PLEASE SEE ANY OTHER POSSIBLE COMMENTS
 FROM OTHER TRADES WHICH MAY AFFECT
 ELECTRICAL PLANS.
  
 ** WHEN AND BEFORE RESUBMITTING PLANS,
 PLEASE COMPLETELY REMOVED ANY OLD/VOIDED
 SHEETS FROM SETS AND ONLY INSERT NEW
 REVISED SHEETS INTO TWO COMPLETE SETS
 FOR REVIEW AND STAMPING.
 ON ECOPY OF THE REMOVED OLD/VOIDED
 SHEETS SHOULD BE SUBMITTED FOR
 REFERENCE.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE AN QUESTIONS,
 PLEASE DO NOT HESITE IN CONTACTING THIS
 OFFICE.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2006-11-14 Cont ID  
Sent By adarroug Date 2006-11-14 Time 14:31 Rev Time 0.00
Received By adarroug Date 2006-11-14 Time 14:31 Sent To M
Notes
2006-11-14 14:32:23TO "TGORDON" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2006-11-03 Cont ID  
Sent By adarroug Date 2006-11-03 Time 09:25 Rev Time 0.00
Received By adarroug Date 2006-11-03 Time 09:25 Sent To M
Notes
2006-11-03 09:25:18TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-09-22 Cont ID  
Sent By adarroug Date 2006-09-22 Time 16:31 Rev Time 0.00
Received By adarroug Date 2006-09-22 Time 16:31 Sent To E
Notes
2006-09-22 00:00:00TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-06-09 Cont ID  
Sent By dpalmer Date 2006-06-09 Time 11:19 Rev Time 0.00
Received By dpalmer Date 2006-06-09 Time 11:18 Sent To Z
Notes
2006-06-09 00:00:00SUBMITTAL PLACED WITH PLANS WHICH WERE
 IN OUT BINS AND ROUTED TO ZONING.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-06-02 Cont ID  
Sent By adarroug Date 2006-06-02 Time 12:13 Rev Time 0.00
Received By adarroug Date 2006-06-02 Time 12:13 Sent To E
Notes
2006-06-02 00:00:00TO "DPALMER" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-05-18 Cont ID  
Sent By adarroug Date 2006-05-18 Time 15:11 Rev Time 0.00
Received By adarroug Date 2006-05-18 Time 15:11 Sent To Z
Notes
2006-05-18 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-04-25 Cont ID  
Sent By alange Date 2006-04-25 Time 09:06 Rev Time 0.00
Received By alange Date 2006-03-29 Time 11:07 Sent To  
Notes
2006-03-29 00:00:00TO "SFR" "Z"

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2006-11-27 Cont ID  
Sent By tgordon Date 2006-11-27 Time 08:30 Rev Time 0.30
Received By tgordon Date 2006-11-27 Time 08:30 Sent To  
Notes
2006-11-27 08:31:43REVISION TO MECH. PLANS AND MANUAL J. CAL'S.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2006-11-06 Cont ID  
Sent By tgordon Date 2006-11-06 Time 08:42 Rev Time 0.30
Received By tgordon Date 2006-11-06 Time 08:42 Sent To  
Notes
2006-11-06 08:47:16REVISION TO MANUAL J CALCULATIONS
 *** DENIED ***
 1) PLEASE SUBMIT A COMPLETE MANUAL J CALCULATION, NOT
 JUST ONE PAGE, PER 2004 FBC 13-607.1.ABC.1.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2006-06-05 Cont ID  
Sent By tgordon Date 2006-06-05 Time 08:31 Rev Time 0.30
Received By tgordon Date 2006-06-05 Time 08:31 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2006-03-31 Cont ID  
Sent By tgordon Date 2006-03-31 Time 08:38 Rev Time 0.45
Received By tgordon Date 2006-03-31 Time 08:38 Sent To P
Notes
2006-03-31 00:00:00*** DENIED ***
 1) ENERGY CALCULATIONS ARE CALLING FOR
 20,900 TOTAL BTU'S AND THE MECHANICAL
 PLANS ARE CALLING FOR 29,800 TOTAL
 BTU'S, THE PLANS CAN NOT CALL FOR MORE
 BTU'S THAN THE ENERGY CAL'S. PLEASE
 CORRECT.
  
 2) PLEASE SUBMIT MANUAL J CALCULATIONS,
 PER 2004 FBC/R M1401.3 .
  
 3) CLOTHES DRYER VENT MUST DISCHARGE A
 MIN. OF 4 FEET FROM THE A/C CONDENSER
 UNIT, PER 2004 FBC/M 501.2 . PLEASE
 CORRECT.
  
 4) THE BATHROOM EXHAUST FAN CAN NOT
 DISCHARGE OVER A WINDOW, PER 2004 FBC/M
 501.2 . PLEASE CORRECT.
  
 5) ELECTRICAL PLANS ARE CALLING FOR A 10
 KW HEATER AND THE MECHANICAL PLANS ARE
 CALLING FOR A 8 KW HEATER, THE TWO MUST
 COINSIDE PLEASE CORRECT.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop P PLUMBING
Rev No 1 Status P Date 2006-03-31 Cont ID  
Sent By jleech Date 2006-03-31 Time 10:29 Rev Time 0.00
Received By jleech Date 2006-03-31 Time 10:28 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status P Date 2006-06-10 Cont ID  
Sent By mmclean Date 2006-06-10 Time 15:58 Rev Time 0.00
Received By mmclean Date 2006-06-10 Time 15:58 Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2006-06-01 Cont ID  
Sent By mmclean Date 2006-06-01 Time 12:12 Rev Time 0.00
Received By mmclean Date 2006-06-01 Time 12:12 Sent To I
Notes
2006-06-01 00:00:00DENIED,
 1. THE PROPOSED DRIVEWAY & WALKWAY HAS
 EXCEEDED THE ZONING GUIDELINES FOR
 CONCRETE WITHIN THE FIRST 25FFT FRONT
 SETBACK.
 2. MUST REDUCE THE PROPOSED DRIVEWAY TO
 11FT WIDE. WITH THE REDUCE DRIVEWAY AND
 PROPOSED WALKWAY THE REQUIREMENTS WILL
 BE MET.
  
 NOTE: MUST MAINTAIN 1000SQ FT OR 75% OF
 LANDSCAPE, WHICHEVER IS LESS WITHIN THE
 FIRST 25FT FRONT SETBACK.
  
 3. MUST PROVIDE TWO COPY OF SURVEY
 SHOWING THE CHANGES IN THE PROPOSED
 DRIVEWAY. & WALKWAY
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720
  

Review Stop Z ZONING
Rev No 1 Status F Date 2006-03-30 Cont ID  
Sent By mmclean Date 2006-03-30 Time 10:32 Rev Time 0.00
Received By mmclean Date 2006-03-30 Time 10:32 Sent To I
Notes
2006-03-30 00:00:00DENIED,
 1. MUST PROVIDE THE DIMENSION OF
 PROPOSED DRIVEWAY (LENGTH & WIDTH)
 2. MUST PROVIDE THE DIMENSION OF WALKWAY
 (LENGTH & WIDTH)
  
 NOTE: MUST MAINTIAN 1000SQ FT OR 75% OF
 LANDSCAPE WITHIN THE FIRST 25FT FRONT
 SETBACK OF PROPERTY (WHICHEVER IS LESS).
  
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720