| Plan Review Stops For Permit 06031114 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2007-02-22 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-02-22 |
Time |
15:51 |
Rev Time |
1.11 |
| Received By |
jwitmer |
Date |
2007-02-22 |
Time |
15:51 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-08-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-08-08 |
Time |
07:11 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2006-08-08 |
Time |
07:11 |
Sent To |
|
|
| Notes |
| 2006-08-08 00:00:00 | PERMIT: 06031114 | | | ADD: 580 VILLAGE BLVD | | | CONT: TEKTRON ELECTRICAL SYSTEMS | | | TEL: (561)844-3156 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | 1)2ND REQUEST,GENERATOR SLAB & ANCHOR | | | REQUIREMENT, PLEASE PROVIDE SIZE OF | | | GENERATOR(WXL), PLUS PROVIDE PLANS WITH | | | THE INFORMATIONDEPICTING HOLD DOWN | | | BRACKETS, TYPE OFFASTENER, AND THE | | | MINIMUM EDGE DISTANCE THE DEVICE | | | REQUIRES WITHOUT LOAD REDUCTION. | | | SECOND, PROVIDE INFORMATION ON THE | | | SLAB, THICKNESS, WIDTH AND LENGTH, IF | | | WIREMESH, FIBER MESH OR IF STEEL REBAR | | | WILL BEUSED. | | | | | | THE PLANS INDICATE THE LENGTH OF | | | THE SLAB MISSING THE WIDTH OF THE | | | PROPOSED SLAB. | | | | | | | | | 2) 2ND REQUEST, 110.2* W. P. B. | | | ADMINISTRATIVE CODE, | | | INFORMATION THAT IS REQUIRED FOR RECORD | | | KEEPING & FOR CERTIFICATE OF OCCUPANCY: | | | A) THE EDITION OFTHE CODE UNDER WHICH | | | THE PERMIT WAS ISSUED. THIS DESIGN IS | | | UNDER THE 2004 FBC, WHICH USES ASCE 7-02 | | | NOT 7-98. CORRECT. THE M).1 SHEET HAS A | | | NOTE THAT THE DESIGN COMPLY WITH HIGH | | | VELOCITY HURRICANE ZONE(FBC 1820.5). | | | THIS IS A REQUIREMENET FOR DADE AND | | | BROWARD COUNTIES UNENFORCEABLE IN PALM | | | BEACH COUNTY. | | | B) PROVIDE OCCUPANCY, IN ACCORDANCE | | | WITH THE PROVISIONS OF CHAPTER 3. SOME | | | OCCUPANCIES REQUIRE EMERGENCY GENERATORS | | | WITH MINIMUM STANDARDS. | | | C) THE TYPE OF CONSTRUCTION AS DEFINED | | | IN CHAPTER 6, TABLE 601. AGAIN | | | PROVIDE THE MINIMUM BUILDING TYPE, SOME | | | BUILDING TYPES REQUIRE GENERATORS WITH | | | MINIMUM STANDARDS. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-05-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-05-08 |
Time |
16:29 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2006-05-08 |
Time |
16:29 |
Sent To |
|
|
| Notes |
| 2006-05-08 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 06031114 | | | ADD: 580 VILLAGE BLVD | | | CONT: TEKTRON ELECTRICAL SYSTEMS | | | TEL: (561)844-3156 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | 1) GENERATOR SLAB & ANCHOR REQUIREMENT | | | PLEASE PROVIDE SIZE OF GENERATOR(WXL), | | | PLUS PROVIDE PLANS WITH THE INFORMATION | | | DEPICTING HOLD DOWN BRACKETS, TYPE OF | | | FASTENER, AND THE MINIMUM EDGE DISTANCE | | | THE DEVICE REQUIRES WITHOUT LOAD | | | REDUCTION. | | | SECOND, PROVIDE INFORMATION ON THE | | | SLAB, THICKNESS, WIDTH AND LENGTH, IF | | | WIREMESH, FIBER MESH OR IF STEEL REBAR | | | WILL BEUSED. | | | THE NEW SLAB AND HOLD DOWN DETAILS: | | | 104.2.1* ALL INFORMATION, DRAWINGS, | | | SPECIFICATIONS AND ACCOMPANYING DATA | | | SHALL BEAR THE NAME AND SIGNATURE OF THE | | | PERSON RESPONSIBLE FOR THE DESIGN. | | | | | | 2)110.2* W. P. B. ADMINISTRATIVE CODE, | | | INFORMATION THAT IS REQUIRED FOR RECORD | | | KEEPING & FOR CERTIFICATE OF OCCUPANCY: | | | A) THE EDITION OFTHE CODE UNDER WHICH | | | THE PERMIT WAS ISSUED. | | | B) THE USE AND OCCUPANCY, IN ACCORDANCE | | | WITH THE PROVISIONS OF CHAPTER 3. | | | C) THE TYPE OF CONSTRUCTION AS DEFINED | | | IN CHAPTER 6, TABLE 601. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2007-01-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-01-22 |
Time |
11:37 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-01-22 |
Time |
11:37 |
Sent To |
|
|
| Notes |
| 2007-01-22 11:38:17 | STAMPED SUBMITTALS OK FOR ELEC, PENDING OTHER TRADES | | | REVIEWS. | | | STAMPED: | | | GEN. | | | ATS, | | | UPS. | | | AND E-SHEETS |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-08-06 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-08-06 |
Time |
19:02 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-08-06 |
Time |
18:30 |
Sent To |
|
|
| Notes |
| 2006-08-06 00:00:00 | ********** UNSAT2ND REVIEW *********** | | | | | | ** PLEASE SEE BELOW FOR NOTES FROM | | | PREVIOUS REVIEW AN NEW NOTES WHICH NEED | | | TO BE ADDRESSED. | | | | | | *** IMPORTANT ** | | | BEFORE RSUBMITTING PLANS!! | | | MUST SUBMIT TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. PLEASE SEE SOME SETS | | | CONTAIN OLD SHEETS WHICH ARE STILL | | | RELEVANT HOWEVER THESE ARE NOT IN NEW | | | SETS. PLEASE SEE SOME ITEMS THERE IS | | | ONLY ONE COPYOF AND IT IS REQUIRED TO | | | SUBMIT TWO OF ALL ITEMS. PLEASE PLACE | | | ALL ITEMS INTO TWO SETS IN A NEAT AND | | | ORDERLY FASHION. THIS WILL HELP IN THE | | | REVIEW PROCESS AND TO HELP EXPEDITE THE | | | REVIEW PROCESS FOR PERMIT ISSUANCE.. | | | THIS OFFICE DOES NOT HAVE THE TIME TO DO | | | THIS. | | | | | | 1)NOTE: NO, PLEASE SEE THE SPECS WERE | | | SUBMITTED, HOWEVER COULD NOT LCOATE ANY | | | LISTINGS FROM ANY NRTL. THE CODE BELOW | | | WHICH WAS REFERENCED IN PREVIOUS REVIEW | | | WAS INCORRECT.SHOULD HAVE BEEN 110.3, | | | 90.8 | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE BE SURE TO SUBMIT ALL | | | SPECS FOR ALL UPS SYSTEMS SHOWING A A | | | LISTING FROM A NRTL. | | | 215.5 | | | | | | 2) NOTE:NO, PLEASE SEE GEN AND ATSARE | | | OK, HOWEVER NOW UPON REVIEWING SPEC ON | | | GEN, COULD NOT LOCATE THE WP HOUSING | | | ASSOCITED WITH SAID GEN. | | | FBC 106.1.2, 90.8 | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SUBMIT ALL MANUFACTURES | | | CUT/SPEC SHEETS FOR GENERATOR AND ATS. | | | UNABLE TO VERIFY SOME ITEMS FOR CODE | | | COMPLIANCE. | | | | | | 3) NOTE:OK, HOWEVER PLEASE SEE PLANS NOW | | | REFLECT THE LATEST EDITION. PLEASE KNOW | | | THE LATEST EDITON WOULD BE THE 2005 NEC, | | | AND AS OF YET THE STATE OF FLORIDA HAS | | | NOT ADOPTED SAID CODE. PLEASE LIST THE | | | 2002 NFPA-70 AND 2002 NFPA-110 | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE PLANS REFERENCE THE | | | 2001 FBC. | | | PLEASE KNOW AS OF OCT 1ST, 2005 THE NEW | | | FBC 2004 IS IN EFFECT. | | | PLEASE ALSO REFERENCE NFPA-110 | | | STANDARDS. | | | | | | 4) NOTE: OK, NEW MAIN ADDED | | | | | | ** NEW NOTES ** | | | | | | 5) NOTE: AS STATED IN THE BEGINING OF | | | THIS REVIEW PLEASE SUBMIT TWO COMPLETE | | | SETS. PLEASE SEE ONE SET IS MISSING | | | SHEET E2.1. PLEASE SEE SHEETS ARE NOT | | | SIGNED, DATED OR SEALED BY THE ENGINEER | | | OF RECORD. | | | PLEASE ALSO SEE OTHER SHEET FOR A/C | | | INFORMATION ARE SIGNED, DATED AND | | | SEALED, HOWEVER NO TITLE BLOCKS ARE ON | | | PLANS AS REQUIRED. FAC 61G15-23.002 | | | FS 471.025 | | | | | | 6) NOTE: PLEASE SEE DISTANCE FOR SET | | | BACKS OF GEN COULD NOT LOCATED ON COPY | | | OF THE SURVEYS, SITE PLANS OR LANDSCAPE | | | PLANS SUBMITTED. | | | PLEASE ALSO SEE ANY SITE LANDSCAPE PLANS | | | DONE BY THE LANDSCAPE ARCHITECT AND | | | FIRM, SHALL BE SIGNED, DATED AND SEALED, | | | PER FS 481.321 | | | THIS IS REQUIRED EVEN IF COMMENT IS NOT | | | MADE BY ZONING. | | | | | | | | | | | | | | | ** PLEASE SEE POSSIBLE ZONING AND | | | BUILDING COMMENTS, AS A SURVEY/SITE PLAN | | | SHOWING ALL SETBACKS FOR LOCATION OF GEN | | | WAS NOT SUBMITTED, AND ALSO A SLAB | | | DETAIL AND ELEVATION COULD NOT BE | | | LOCATED IN PLANS. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-04-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-04-26 |
Time |
11:37 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-04-26 |
Time |
10:47 |
Sent To |
|
|
| Notes |
| 2006-04-26 00:00:00 | ********** UNSAT ************* | | | | | | 1)NOTE: PLEASE BE SURE TO SUBMIT ALL | | | SPECS FOR ALL UPS SYSTEMS SHOWING A A | | | LISTING FROM A NRTL. | | | 215.5 | | | | | | 2) NOTE:PLEASE SUBMIT ALL MANUFACTURES | | | CUT/SPEC SHEETS FOR GENERATOR AND ATS. | | | UNABLE TO VERIFY SOME ITEMS FOR CODE | | | COMPLIANCE. | | | | | | 3) NOTE: PLEASE SEE PLANS REFERENCE THE | | | 2001 FBC. | | | PLEASE KNOW AS OF OCT 1ST, 2005 THE NEW | | | FBC 2004 IS IN EFFECT. | | | PLEASE ALSO REFERENCE NFPA-110 | | | STANDARDS. | | | | | | 4) NOTE: PLEASE MEANS OF DISCONNECT FOR | | | POWER COMING FROM GENERATOR SHALL BE | | | GROUPED WITH EXISTING MAIN(S). | | | 230.72,230.76,230.79, 225.31-225.39. | | | UNABLE TO VERIFY AT THIS TIME AS | | | EXISTING MAIN FOR BUILDING IS NOT SHOWN. | | | | | | | | | ** PLEASE SEE POSSIBLE ZONING ABD | | | BUILDING COMMENTS, AS A SURVEY/SITE PLAN | | | SHOWING ALL SETBACKS FOR LOCATION OF GEN | | | WAS NOT SUBMITTED, AND ALSO A SLAB | | | DETAIL AND ELEVATION COULD NOT BE | | | LOCATED IN PLANS. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | | | | | ** PLEASE BE AWARE OF COMMENTS FROM | | | OTHER TRADES WHICH MAY AFFECT THE PLANS | | | SUBMITTED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2007-02-20 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-02-20 |
Time |
16:31 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-02-20 |
Time |
16:30 |
Sent To |
|
|
| Notes |
| 2007-02-20 16:32:23 | *****APPROVED***** | | | | | | | | | SHEET E1.1 WAS STAMPED, INITIALED, AND DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2006-09-05 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-09-05 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-09-05 |
Time |
15:00 |
Sent To |
|
|
| Notes |
| 2006-09-05 00:00:00 | ***DENIED*** | | | | | | 1) WORK SHALL COMPLY WITH NFPA 110, | | | STANDARD FOR EMERGENCY AND STANDBY POWER | | | SYSTEMS. PLEASE ACKNOWLEDGE AND INDICATE | | | ON PLANS. | | | | | | 2) PLEASE CLARIFY FUEL SOURCE, NATURAL | | | GAS, PROPANE ETC. | | | | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2006-05-24 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2006-05-24 |
Time |
15:20 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2006-05-24 |
Time |
15:13 |
Sent To |
|
|
| Notes |
| 2006-05-24 00:00:00 | *********DENIED******************** | | | | | | 1) THE INSTALLATION SHALL COMPLY NFPA | | | 110 STANDARD FOR EMERGENCY & STANDBY | | | POWER SYSTEMS. | | | | | | 2) PLEASE PROVIDE CUT/SPEC'S SHEETS ON | | | THE GENERATOR | | | | | | | | | NATE MCCRAY, ASSISTANT FIRE MARSHAL | | | 561-804-4754 |
|
|
| Review Stop |
FUEL |
DIESEL GENERATOR |
| Rev No |
1 |
Status |
N |
Date |
2006-05-13 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-05-13 |
Time |
14:48 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-05-13 |
Time |
14:48 |
Sent To |
|
|
| Notes |
| 2006-05-13 00:00:00 | NATURAL GAS |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
5 |
Status |
P |
Date |
2007-04-25 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-04-25 |
Time |
15:13 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2007-04-25 |
Time |
15:13 |
Sent To |
PC |
|
| Notes |
| 2007-04-25 15:15:09 | REVISION: CHANGED PIPING FROM ABOVE GROUND GALVANIZED | | | TO UNDERGROUND PE. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
4 |
Status |
F |
Date |
2007-04-06 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-04-06 |
Time |
15:56 |
Rev Time |
0.45 |
| Received By |
mperson |
Date |
2007-04-06 |
Time |
15:56 |
Sent To |
PC |
|
| Notes |
| 2007-04-06 16:16:34 | REVISION DENIED | | | REFERENCE: | | | ** FBC-2004 FUEL GAS. | | | ** THE CITY OF WEST PALM BEACH GAS PERMIT APPLICATION | | | REQUIREMENTS. | | | ** FBC-2004 CHAPTER 1, THE CITY OF | | | WEST PALM BEACH AMENDMENTS. | | | ** FLORIDA ADMINISTRATIVE CODE. | | | ** FLORIDA STATUTES. | | | | | | THE FOLLOWING CORRECTIONS/INFORMATION REQUIRED FOR GAS | | | PLAN REVIEW TO MEET CODE COMPLIANCE: | | | | | | 1. PLEASE NOTE THAT ON SHEET M1.1 THERE IS AN APPROVED | | | GAS RISER THAT IS SIGNED AND SEALED BE DANIEL E. | | | THOMPSON FLA. REG. NO. 33289 OF THE "THOMPSON & | | | YOUNGROSS ENGINEERING CONSULTANTS, LLC" AND ANY | | | REVISIONS TO THAT GAS RISER NEEDS TO BE SIGNED AND | | | SEALED BY SAID DESIGN PROFESSIONAL PER CHAPTER 471, | | | FLORIDA STATUTES. PLEASE NOTE THAT A GAS PERMIT IS | | | REQUIRED FOR THIS WORK AND ONE HAS NOT BEEN ISSUED AS | | | OF THIS DATE 4/6/07. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2007-02-21 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-02-21 |
Time |
11:12 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-02-21 |
Time |
11:12 |
Sent To |
|
|
| Notes |
| 2007-02-21 11:14:53 | PER CONTRACTOR, (R.B.) THE PIPING IS NOT UNDERGROUND, | | | BUT STRAPPED TO THE SLAB. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2006-08-12 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-08-12 |
Time |
09:07 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-08-12 |
Time |
09:07 |
Sent To |
|
|
| Notes |
| 2006-08-12 00:00:00 | | | | PAUL SCHMITZ | | | FBC 2004 FUEL GAS CODE, PLAN REVIEW | | | | | | | | | NEW COMMENTSUNSAT | | | | | | THE FOLLOWING INFORMATION IS REQUIRED | | | FOR THE GAS PERMIT. | | | | | | 1) SHT M1.1 GAS SYSTEM NOTES: | | | REMOVE NOTES THAT DO NOT PERTAIN TO THE | | | GENERATOR INSTALLATION. | | | | | | 2. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2004 | | | FUEL GAS CODE. | | | | | | 3. SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED,FOR EACH PIPE SIZE BEING | | | USED. | | | | | | 4. TYPE OF GAS, (LP OR NATURAL) | | | | | | 5.BTU LOAD OF GENERATOR UNDER FULL LOAD. | | | REFER TO THE FBC-2004 FUEL GAS CODE | | | SECS. 401.8 THRU 402.6.1 AND TABLES | | | 402.4(1) THRU 402.4(33). | | | | | | 5. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE SYSTEM PER FBC-2004 FUEL | | | GAS CODE APPENDIX A - USE OF CAPACITY | | | TABLES A.3.1(4). | | | | | | 6. INDICATE THE DELIVERY PRESSURE (PSI) | | | PER FBC-2004 FUEL GAS CODE SEC. 402.2. | | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. | | | | | | 7 WHEN RESUBMITTING PLANS PLEASE | | | INDICATE THE REVISION & REMOVE & REPLACE | | | ANY PAGES AS NECESSARY. | | | A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT NUMBER, WITH A | | | DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND, | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 8 SEE OTHER PLAN REVIEW COMMENTS, THAT | | | MAY EFFECT PLUMBING PLAN REVIEW. | | | | | | | | | END OF COMMENTS, QUESTIONS 561-805-6692 |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2006-05-13 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-05-13 |
Time |
14:52 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-05-13 |
Time |
14:52 |
Sent To |
|
|
| Notes |
| 2006-05-13 00:00:00 | | | | | | | PAUL SCHMITZ | | | FBC 2004 FUEL GAS CODE, PLAN REVIEW | | | | | | | | | UNSAT | | | 1) SHT E2.1 | | | | | | THE FOLLOWING INFORMATION IS REQUIRED | | | FOR THE GAS PERMIT: | | | | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2004 | | | FUEL GAS CODE. | | | | | | 2. SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE BEING USED. | | | 3. TYPE OF GAS, (LP OR NATURAL) | | | | | | 4. BTU LOAD OF EACH APPLIANCE AND THE | | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | | THE FBC-2004 FUEL GAS CODE SECS. 401.8 | | | THRU 402.6.1 AND TABLES 402.4(1) THRU | | | 402.4(33). | | | | | | 5. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES A.3.1(4). | | | | | | 6. SUBMIT CALCULATIONS FOR COMBUSTION | | | AIR (IF APPLICABLE) PER FBC-2004 FUEL | | | GAS CODE SECTION 304 | | | . | | | 7. INDICATE THE DELIVERY PRESSURE (PSI) | | | PER FBC-2004 FUEL GAS CODE SEC. 402.2. | | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. | | | | | | 8. SUBMIT A DETAIL SHOWING THE TYPE, | | | LOCATION, SIZE AND TERMINATION OF THE | | | GAS VENTS PER FBC-2004 FUEL GAS CODE | | | SECS. 502 THRU 505. | | | | | | | | | | | | 9. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2004 FUEL GAS CODE SEC 402.2. | | | | | | 10) SEE OTHER PLAN REVIEW COMMENTS, THAT | | | MAY EFFECT PLUMBING PLAN REVIEW. | | | | | | | | | END OF COMMENTS, QUESTIONS 561-805-6692 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2007-04-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-04-19 |
Time |
13:05 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-04-19 |
Time |
13:05 |
Sent To |
M |
|
| Notes |
| 2007-04-19 13:05:49 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2007-03-27 |
|
|
Cont ID |
|
| Sent By |
spalmer |
Date |
2007-03-27 |
Time |
18:38 |
Rev Time |
0.00 |
| Received By |
spalmer |
Date |
2007-03-27 |
Time |
18:38 |
Sent To |
G |
|
| Notes |
| 2007-03-27 18:38:51 | TO MIKE PERSON |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-01-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-01-09 |
Time |
18:43 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-01-09 |
Time |
18:43 |
Sent To |
|
|
| Notes |
| 2007-01-22 08:35:25 | TO "COMM" BD#51 | | 2007-01-09 18:44:03 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-08-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-08-05 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-08-05 |
Time |
14:31 |
Sent To |
|
|
| Notes |
| 2006-08-05 00:00:00 | TO COMM BOARD #28 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-07-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-07-21 |
Time |
15:23 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-07-21 |
Time |
15:23 |
Sent To |
|
|
| Notes |
| 2006-07-21 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-05-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-24 |
Time |
15:21 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-03-24 |
Time |
13:27 |
Sent To |
|
|
| Notes |
| 2006-03-24 00:00:00 | WAITING FOR COMM BOARD. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2007-04-20 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-04-20 |
Time |
08:50 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-04-20 |
Time |
08:50 |
Sent To |
G |
|
| Notes |
| 2007-04-20 08:52:53 | GAS REVISION TO PLANS PAGE M1.1, NO MECHANICAL CHANGES | | | RE-STAMP. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2007-01-22 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-01-22 |
Time |
15:32 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-01-22 |
Time |
15:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2006-08-15 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-08-15 |
Time |
09:38 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2006-08-15 |
Time |
09:38 |
Sent To |
|
|
| Notes |
| 2006-08-15 00:00:00 | *** DENIED *** | | | 1) NEED TWO COPYS OF THE A/C SIZING | | | CALCULATIONS, AND THEY NEED THE | | | ENGINEERSINFORMATION ON THEM NAME | | | ADDRESS, LICENSE NUMBER, ECT. ON TITLI | | | BLOCK OR LETTER HEAD WITH HIE SEAL, PER | | | FAC 61G15-23.002 . | | | | | | 2) SEE ELECTRICAL REVIEW NOTE REGUARDING | | | TWO COMPLETE SETS. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-05-08 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-05-08 |
Time |
14:02 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-05-08 |
Time |
14:02 |
Sent To |
|
|
| Notes |
| 2006-05-08 00:00:00 | *** DENIED *** | | | 1) SHOW SIZES OF ALL SUPPLY AIR DUCTS | | | (FLEX). | | | | | | 2) PLEASE PROVIDE OUTDOOR AIR FOR AHU | | | #1, PER 2004 FBC/M 401 . | | | | | | 3) RETURN AIR TRANSFER DUCTS ARE | | | UNDER-SIZED SEE NOTE #4 (A). | | | | | | 4)BALANCED RETURN AIR. | | | THIS MAY BE ACHIEVED BY. | | | (A)TRANSFER DUCTS MAY ACHIEVE THIS BY | | | INCREASING THE RETURN TRANSFER ONE AND | | | ONE HALF TIMES THE CROSS SECTIONAL AREA | | | (SQUARE INCHES) OF THE SUPPLY DUCT | | | ENTERING THE ROOM OR SPACE IT'S SERVING | | | AND THE DOOR HAVING AT LEAST AN | | | UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE | | | PROPER RETURN AIR BALANCE. | | | (B)TRANSFER GRILLES SHALL USE 50 | | | SQUARE INCHES (OF GRILLE AREA) TO 100 | | | CFM (OF SUPPLY AIR) FOR SIZING | | | THROUGH-THE-WALL TRANSFER GRILLES AND | | | USING AN UNRESTRICTED 1-INCH | | | UNDERCUTTING OF DOORS TO ACHIEVE PROPER | | | RETURN AIR BALANCE | | | (C)HABITABLE ROOMS ONLY SHALL BE | | | REQUIRED TO MEET THESE REQUIREMENTS FOR | | | PROPER BALANCED RETURN AIR EXCLUDING | | | BATHROOMS, CLOSETS, STORAGE ROOMS AND | | | LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY | | | AIR INTO THE MASTER SUITE SHALL BE | | | INCLUDED. PER 2004 FBC/R M1602.4 . | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2006-05-13 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-05-13 |
Time |
14:49 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-05-13 |
Time |
14:49 |
Sent To |
|
|
| Notes |
| 2006-05-13 00:00:00 | NATURAL GAS |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2007-01-26 |
|
|
Cont ID |
|
| Sent By |
kdfreema |
Date |
2007-01-26 |
Time |
08:35 |
Rev Time |
0.00 |
| Received By |
kdfreema |
Date |
2007-01-26 |
Time |
08:35 |
Sent To |
|
|
| Notes |
| 2007-01-26 08:38:36 | A LANDSCAPED SCREEN WALL IS REQUIRED. THE WALL SHALL BE | | | INSTALLED UNDER A SEPERATE PERMIT. | | 2007-01-22 11:16:19 | NEW REVISED SITE, SURVEY AND LANDSCAPE SHEETS |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2006-08-17 |
|
|
Cont ID |
|
| Sent By |
kdfreema |
Date |
2006-08-17 |
Time |
17:50 |
Rev Time |
0.00 |
| Received By |
kdfreema |
Date |
2006-08-17 |
Time |
17:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2006-05-12 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2006-05-12 |
Time |
19:28 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2006-05-12 |
Time |
19:28 |
Sent To |
|
|
| Notes |
| 2006-05-12 00:00:00 | 5/12/06 ***FAILED*** | | | | | | 1) MINOR AMENDMENT TO THE PLANNED | | | DEVELOPMENT SHALL BE SUBMITTED AND | | | APPROVED BY THE PLANNING AND ZONING | | | DEPARTMENT PRIOR TO APPROVAL OF BUILDING | | | PERMIT. | | | | | | 2) SURVEY SHALL BE PROVIDED. | | | | | | 3) SITE PLAN SHALL BE PROVIDED | | | INDICATING THE LOCATION OF ALL EXTERIOR | | | IMPROVEMENTS. | | | | | | 4) ELEVATIONS OF GENERATOR AND OTHER | | | EQUIPMENT LOCATED ON THE EXTERIOR SHALL | | | BE PROVIDED. | | | | | | 5) GENERATOR AND OTHER EXTERIOR | | | EQUIPMENT WILL NEED TO BE SCREENED WITH | | | A SOLID WALL/FENCE AND LANDSCAPING. | | | LANDSCAPE PLANS SHALL BE PROVIDED. | | | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, | | | SENIOR PLANNER, AT (561) 822-1435. |
|
|