Plan Review Details - Permit 06031084
| Plan Review Stops For Permit 06031084 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2006-05-16 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-05-16 |
Time |
13:37 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-05-16 |
Time |
13:37 |
Sent To |
|
|
| Notes |
| 2006-05-16 00:00:00 | PROVISO | | | | | | ON FUTURE SUBMITTALS OF RAS 117 | | | CALCULATIONS FOR ENHANCED FASTENING OF | | | THE BASE SHEET, IN ADDITION TO THE | | | SIGNED AND SEALED CONCLUSION PAGE SUBMIT | | | THE ACTUAL CALCULATIONS SIGNED AND | | | SEALED BY THE ENGINEER. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-04-11 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-04-11 |
Time |
13:10 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-04-11 |
Time |
12:30 |
Sent To |
|
|
| Notes |
| 2006-04-11 00:00:00 | DENIED | | | | | | 1) THE SYSTEM YOU SELECTED FROM THE | | | TAMKO NOA THAT WAS SUBMITTED IS FOR USE | | | AS A TILE UNDERLAYMENT. SELECT A SYSTEM | | | THAT CAN BE USED FOR A FLAT ROOF AND | | | CIRCLE THE DESIGN PRESSURE FOR THE | | | FASTENING METHOD THAT WILL BE USED. | | | | | | 2) THE HIGHEST MAXIMUM DESIGN PRESSURE | | | FOR THE SYSTEMS LISTED IN THE TAMKO NOA | | | IS -60 PSF. THE REQUIRED DESIGN PRESSURE | | | FOR THE CORNERS IS -89 PSF PER FBC TABLE | | | 1609.6B. THEREFORE, ENHANCED FASTENING | | | PER RAS 117 WILL BE REQUIRED. THIS IS | | | ALLOWED FOR SOME OF THE ASSEMBLIES BY | | | LIMITATION NUMBER 7 ON THE LAST PAGE OF | | | THE NOA. HOWEVER, THISLIMITATION ALSO | | | REQUIRES THAT THESE CALCULATIONS ARE | | | SIGNED AND SEALED BY AN ENGINEER, | | | ARCHITECT OR REGISTERED ROOFING | | | CONSULTANT. | | | | | | 3) THE NOA THAT IS LISTED WITH THE STATE | | | FOR THE GAF ROYAL SOVERIGN SHINGLE IS | | | NOA 04-0820.01. PLEASE SUBMIT TWO COPIES | | | OF THIS NOA. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-03-23 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-03-23 |
Time |
11:24 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-03-23 |
Time |
11:24 |
Sent To |
|
|
| Notes |
| 2006-03-23 00:00:00 | DENIED | | | | | | 1) ENHANCED FASTENING IS REQUIRED TO | | | INCREASE DESIGN PRESSURE FOR TAMKO | | | MODIFIED SYSTEM. NOA LIMITATION NUMBER 7 | | | REQUIRES THESE CALCULATIONS TO BE DONE | | | BY ENGINEER, ARCHITECT OR REGISTERED | | | ROOF CONSULTANT. SUBMIT SIGNED AND | | | SEALED CALCULATIONS. | | | | | | 2) SUBMIT THE UPDATED COVERSHEET FROM | | | THE STATE FL #183-R1 AND THE | | | CORRESPONDING NOA 04-0820.01. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | |
|
|
|