Plan Review Details - Permit 06031067
Plan Review Stops For Permit 06031067
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2006-07-25 Cont ID  
Sent By alange Date 2006-07-25 Time 09:32 Rev Time 0.75
Received By alange Date 2006-07-25 Time 09:32 Sent To  
Notes
2006-07-25 00:00:00TRUSS DRAWINGS REVIEWED

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2006-06-08 Cont ID  
Sent By alange Date 2006-06-08 Time 12:52 Rev Time 2.00
Received By alange Date 2006-06-08 Time 12:52 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-04-24 Cont ID  
Sent By alange Date 2006-04-24 Time 09:32 Rev Time 3.00
Received By alange Date 2006-04-24 Time 09:29 Sent To  
Notes
2006-04-24 00:00:00DENIED
  
  
 1. 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE
 RE-RECORDED IF THE DESCRIBED IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 3.THOSE PRODUCT APPROVALS WHICH ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.WPB
 AMENDMENT TO FBC 106.3.3.
  
 4.SUBMIT TWO SETS OF TRUSS DRAWINGS
 FOR REVIEW PER 2004 FBC R-802.10.1
  
 5.SHOW GUARD RAIL DETAIL COMPLYING
 WITH FBC R-312.1 AND R-312.2.
  
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. SUBMIT ONE COPY OF
 OLD PAGES FOR REFERENCE. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET
 OR SPECIFICATION PAGE WHERE THE CHANGES
 CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 ART LANGE
 CONSTRUCTION SERVICES DEPARTMENT
 BUILDING PLANS EXAMINER
 561-805-6672
  
  

Review Stop E ELECTRICAL
Rev No 4 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By btrobaug Date 2007-07-16 Time 15:19 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2007-03-26 Cont ID  
Sent By btrobaug Date 2007-03-26 Time 14:36 Rev Time 0.50
Received By btrobaug Date 2007-03-26 Time 13:16 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-05-26 Cont ID  
Sent By btrobaug Date 2006-05-26 Time 17:38 Rev Time 0.50
Received By btrobaug Date 2006-05-26 Time 17:15 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-03-24 Cont ID  
Sent By btrobaug Date 2006-03-24 Time 07:20 Rev Time 1.50
Received By btrobaug Date 2006-03-24 Time 06:11 Sent To M
Notes
2006-03-24 00:00:00 
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} THE LOAD CALCULATION INDICATES A 250
 AMP MAIN BREAKER, THE RISER DIAGRAM
 SHOWS 2/0 CONDUCTORS FOR THE SERVICE
 FROM THE METER TO THE MAIN
 DISCONNECT.THE MINIMUM CONDUCTOR SIZE IS
 4/0 COPPER PER 310.15(B(6). ALSO THE
 CONDUCTORS IN THE RISER AND THE CONDUIT
 SIZE AND TYPE ARE NOT IDENTIFIED.
  
 2} THE OCP FOR CIRCUITS 19'21'26'28 IN
 PANEL "A", AND 18 THROUGH 22 IN PANEL
 "B" IS TOO LARGE FOR THE CONDUCTORS, 20
 AMP FOR #14 WIRE. SEE 310.16.
  
 NOTE: THE TOTAL LOAD FOR THE SERVICE IS
 207 AMPS ON A 250 AMP SERVICE. THERE IS
 A PROPOSED POOL, THIS REVIEW WOULD
 RECOMMEND A LARGER SERVICEFOR FUTURE
 INCREASED LOADS. PLEASE SEE ARTICLE
 90.1(A) AND THE FPN.
  
 3} A LIGHT IS REQUIRED FOR EXTERIOR
 ILLUMINATION AT THE EXTERIOR SERVICE
 DOOR PER 210.70(A)(2)(B).
  
 4} A SMOKE DETECTOR IS REQUIRED IN
 BEDROOM #5 PER R313 FBC.
  
 5} ELECTRICAL NOTE #3 INDICATES GFI
 PROTECTION FOR RECEPTACLES WITHIN 6'
 OF THE KITCHEN SINK. PLEASE SEE
 210.8(A)(6), ALL COUNTERTOP RECEPTACLES,
 REGERDLESS OF LOCATION. ALSO NOTE #7
 REFERS TO THE 1996 NEC.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2007-03-22 Cont ID  
Sent By adarroug Date 2007-03-22 Time 10:17 Rev Time 0.00
Received By adarroug Date 2007-03-22 Time 10:17 Sent To E
Notes
2007-03-22 10:17:43TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2007-03-12 Cont ID  
Sent By adarroug Date 2007-03-12 Time 08:43 Rev Time 0.00
Received By adarroug Date 2007-03-12 Time 08:43 Sent To M
Notes
2007-03-12 08:43:43TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-07-22 Cont ID  
Sent By adarroug Date 2006-07-22 Time 13:32 Rev Time 0.00
Received By adarroug Date 2006-07-22 Time 13:32 Sent To B
Notes
2006-07-22 00:00:00TO "ALANGE" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-05-26 Cont ID  
Sent By adarroug Date 2006-05-26 Time 11:01 Rev Time 0.00
Received By adarroug Date 2006-05-26 Time 11:01 Sent To E
Notes
2006-05-26 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-05-16 Cont ID  
Sent By adarroug Date 2006-05-16 Time 11:01 Rev Time 0.00
Received By adarroug Date 2006-05-16 Time 11:01 Sent To Z
Notes
2006-05-16 00:00:00TO "Z" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-04-24 Cont ID  
Sent By alange Date 2006-04-24 Time 09:33 Rev Time 0.00
Received By alange Date 2006-03-23 Time 08:48 Sent To Z
Notes
2006-03-23 00:00:00TO SFR RACK

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2007-03-12 Cont ID  
Sent By tgordon Date 2007-03-12 Time 14:48 Rev Time 0.30
Received By tgordon Date 2007-03-12 Time 14:48 Sent To  
Notes
2007-03-12 14:48:51REVISION TO MECH. PLANS PAGE A-14.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2006-05-30 Cont ID  
Sent By tgordon Date 2006-05-30 Time 10:23 Rev Time 0.35
Received By tgordon Date 2006-05-30 Time 10:23 Sent To P
Notes
2006-05-30 00:00:00*** PROVISO ***
 1) PROVIDE COMBUSTION AIR FOR GAS
 CLOTHES DRYER, PER 2004 FBC/M 701.1 .
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2006-03-27 Cont ID  
Sent By tgordon Date 2006-03-27 Time 13:40 Rev Time 0.45
Received By tgordon Date 2006-03-27 Time 13:39 Sent To B
Notes
2006-03-27 00:00:00*** DENIED ***
 1)NEED DETAILED MANUFACTURE'S
 SPECIFICATION'S AND INSTALLATION
 INSTRUCTIONS FOR VENT LESS GAS FIRE
 PLACE.
  
 2)NEED DETAILED MANUFACTURE'S
 SPECIFICATION'S AND INSTALLATION
 INSTRUCTIONS FOR TANKLESS GAS WATER
 HEATER.
  
 3) SHOW LOCATION ON MECHANICAL PLANS FOR
 TANKLESS GAS WATER HEATER.
  
 4) PROVIDE COMBUSTION AIR AND COMBUSTION
 AIR CALCULATIONS ON MECHANICAL PLANS FOR
 GAS CLOTHES DRYER.PER 2004 FBC/R M1701.1
  
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2007-07-18 Cont ID  
Sent By jleech Date 2007-07-18 Time 07:09 Rev Time 0.00
Received By jleech Date 2007-07-18 Time 07:09 Sent To  
Notes
2007-07-18 07:09:51REVISED WATER HEATER TO ON DEMAND TYPE.

Review Stop P PLUMBING
Rev No 2 Status P Date 2006-06-06 Cont ID  
Sent By jleech Date 2006-06-06 Time 15:58 Rev Time 0.00
Received By jleech Date 2006-06-06 Time 15:58 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2006-03-24 Cont ID  
Sent By jleech Date 2006-03-24 Time 08:42 Rev Time 0.33
Received By jleech Date 2006-03-24 Time 08:42 Sent To Z
Notes
2006-03-24 00:00:00DENIED;
 1.THE AUTOMATIC CLOTHES WASHER CANNOT
 RUN THRU THE MASTER BATHROOM GROUP SEC.
 909.1. ( MARKED IN RED)
 2.PAGE A-12
 GAS APPLIANCES. VENTILATION ACCORDING TO
 2004 CODE NOT 2001. WHERE IS LISTED
 WATER HEATER LOCATION? (STANDERD 50 GAL.
 HEATER)
 3.TANKLESS WATER HEATER SHOWN OUTSIDE
 KITCHEN MAYBE TO CLOSE TO KITCHEN
 WINDOW. PLEASE CHECK MANUFACTURE
 INSTALLATION RECOMMENDATIONS.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop Z ZONING
Rev No 2 Status P Date 2006-05-25 Cont ID  
Sent By mmclean Date 2006-05-25 Time 10:36 Rev Time 0.00
Received By mmclean Date 2006-05-25 Time 10:36 Sent To I
Notes
2006-05-25 00:00:00NOTE: MUST PULL A SEPERATE PERMIT FOR
 POOL/SPA/SCREEN ENCLOSURE/DECK.
  
 NOTE: MUST PULL A SEPERATE PERMIT FOR
 WALL/GATE/FENCE WITH EASEMENT APPROVAL
 FROM CITY OF WEST PALM BEACH.IF ANY
 OTHER UTILITY EASEMENT ON PROPERTY
 (BELLSOUTH/ADELPHIA/FPL/FLORIDA PUBLIC
 UTILITIES WILL BE NEEDED) IF APPLICABLE.

Review Stop Z ZONING
Rev No 1 Status F Date 2006-03-27 Cont ID  
Sent By alange Date 2006-04-24 Time 09:33 Rev Time 0.00
Received By mmclean Date 2006-03-27 Time 07:35 Sent To M
Notes
2006-03-27 00:00:00DENIED,
 1. MUST PROVIDE TWO CURRENT COPY OF
 SURVEY SHOWING THE LOCATION OF THE
 STRUCTURE WITH SETBACKS.
 2. THE STRUCTURE IS OVER THE HEIGHT
 REQUIREMENT OF33FT. (ALLOWED 30FT FOR
 STRUCTURE & 10% FOR CHIMNEY = 33FT).
  
 NOTE: MUST PULL A SEPERATE PERMIT FOR
 POOL/SPA/SCREEN ENCLOSURE/DECK.
 NOTE: MUST PULL A SEPERATE PERMIT FOR
 WALL/GATE/FENCE WITH EASEMENT APPROVAL
 FROM CITY OF WEST PALM BEACH.IF ANY
 OTHER UTILITY EASEMENT ON PROPERTY
 (BELLSOUTH/ADELPHIA/FPL/FLORIDA PUBLIC
 UTILITIES WILL BE NEEDED) IF APPLICABLE.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720