| Plan Review Stops For Permit 06031067 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2006-07-25 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-07-25 |
Time |
09:32 |
Rev Time |
0.75 |
| Received By |
alange |
Date |
2006-07-25 |
Time |
09:32 |
Sent To |
|
|
| Notes |
| 2006-07-25 00:00:00 | TRUSS DRAWINGS REVIEWED |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2006-06-08 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-06-08 |
Time |
12:52 |
Rev Time |
2.00 |
| Received By |
alange |
Date |
2006-06-08 |
Time |
12:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-04-24 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-04-24 |
Time |
09:32 |
Rev Time |
3.00 |
| Received By |
alange |
Date |
2006-04-24 |
Time |
09:29 |
Sent To |
|
|
| Notes |
| 2006-04-24 00:00:00 | DENIED | | | | | | | | | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT | | | SHALL BE RECORDED AT PALM BEACH COUNTY | | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | | BLANK FORMS ARE AVAILABLE FROM THIS | | | OFFICE. | | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE | | | RE-RECORDED IF THE DESCRIBED IMPROVEMENT | | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | | 90 DAYS OF RECORDING. | | | | | | 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 3.THOSE PRODUCT APPROVALS WHICH ARE | | | REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL | | | FOR JURISDICTIONAL APPROVAL.WPB | | | AMENDMENT TO FBC 106.3.3. | | | | | | 4.SUBMIT TWO SETS OF TRUSS DRAWINGS | | | FOR REVIEW PER 2004 FBC R-802.10.1 | | | | | | 5.SHOW GUARD RAIL DETAIL COMPLYING | | | WITH FBC R-312.1 AND R-312.2. | | | | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. SUBMIT ONE COPY OF | | | OLD PAGES FOR REFERENCE. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET | | | OR SPECIFICATION PAGE WHERE THE CHANGES | | | CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | ART LANGE | | | CONSTRUCTION SERVICES DEPARTMENT | | | BUILDING PLANS EXAMINER | | | 561-805-6672 | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-07-16 |
Time |
15:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2007-03-26 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-03-26 |
Time |
14:36 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2007-03-26 |
Time |
13:16 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2006-05-26 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-05-26 |
Time |
17:38 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-05-26 |
Time |
17:15 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-03-24 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-03-24 |
Time |
07:20 |
Rev Time |
1.50 |
| Received By |
btrobaug |
Date |
2006-03-24 |
Time |
06:11 |
Sent To |
M |
|
| Notes |
| 2006-03-24 00:00:00 | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} THE LOAD CALCULATION INDICATES A 250 | | | AMP MAIN BREAKER, THE RISER DIAGRAM | | | SHOWS 2/0 CONDUCTORS FOR THE SERVICE | | | FROM THE METER TO THE MAIN | | | DISCONNECT.THE MINIMUM CONDUCTOR SIZE IS | | | 4/0 COPPER PER 310.15(B(6). ALSO THE | | | CONDUCTORS IN THE RISER AND THE CONDUIT | | | SIZE AND TYPE ARE NOT IDENTIFIED. | | | | | | 2} THE OCP FOR CIRCUITS 19'21'26'28 IN | | | PANEL "A", AND 18 THROUGH 22 IN PANEL | | | "B" IS TOO LARGE FOR THE CONDUCTORS, 20 | | | AMP FOR #14 WIRE. SEE 310.16. | | | | | | NOTE: THE TOTAL LOAD FOR THE SERVICE IS | | | 207 AMPS ON A 250 AMP SERVICE. THERE IS | | | A PROPOSED POOL, THIS REVIEW WOULD | | | RECOMMEND A LARGER SERVICEFOR FUTURE | | | INCREASED LOADS. PLEASE SEE ARTICLE | | | 90.1(A) AND THE FPN. | | | | | | 3} A LIGHT IS REQUIRED FOR EXTERIOR | | | ILLUMINATION AT THE EXTERIOR SERVICE | | | DOOR PER 210.70(A)(2)(B). | | | | | | 4} A SMOKE DETECTOR IS REQUIRED IN | | | BEDROOM #5 PER R313 FBC. | | | | | | 5} ELECTRICAL NOTE #3 INDICATES GFI | | | PROTECTION FOR RECEPTACLES WITHIN 6' | | | OF THE KITCHEN SINK. PLEASE SEE | | | 210.8(A)(6), ALL COUNTERTOP RECEPTACLES, | | | REGERDLESS OF LOCATION. ALSO NOTE #7 | | | REFERS TO THE 1996 NEC. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2007-03-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-22 |
Time |
10:17 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-22 |
Time |
10:17 |
Sent To |
E |
|
| Notes |
| 2007-03-22 10:17:43 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2007-03-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-12 |
Time |
08:43 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-12 |
Time |
08:43 |
Sent To |
M |
|
| Notes |
| 2007-03-12 08:43:43 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-07-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-07-22 |
Time |
13:32 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-07-22 |
Time |
13:32 |
Sent To |
B |
|
| Notes |
| 2006-07-22 00:00:00 | TO "ALANGE" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-05-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-26 |
Time |
11:01 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-26 |
Time |
11:01 |
Sent To |
E |
|
| Notes |
| 2006-05-26 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-05-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-16 |
Time |
11:01 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-16 |
Time |
11:01 |
Sent To |
Z |
|
| Notes |
| 2006-05-16 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-04-24 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-04-24 |
Time |
09:33 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-03-23 |
Time |
08:48 |
Sent To |
Z |
|
| Notes |
| 2006-03-23 00:00:00 | TO SFR RACK |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2007-03-12 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-03-12 |
Time |
14:48 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-03-12 |
Time |
14:48 |
Sent To |
|
|
| Notes |
| 2007-03-12 14:48:51 | REVISION TO MECH. PLANS PAGE A-14. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2006-05-30 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-05-30 |
Time |
10:23 |
Rev Time |
0.35 |
| Received By |
tgordon |
Date |
2006-05-30 |
Time |
10:23 |
Sent To |
P |
|
| Notes |
| 2006-05-30 00:00:00 | *** PROVISO *** | | | 1) PROVIDE COMBUSTION AIR FOR GAS | | | CLOTHES DRYER, PER 2004 FBC/M 701.1 . | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-03-27 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-03-27 |
Time |
13:40 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2006-03-27 |
Time |
13:39 |
Sent To |
B |
|
| Notes |
| 2006-03-27 00:00:00 | *** DENIED *** | | | 1)NEED DETAILED MANUFACTURE'S | | | SPECIFICATION'S AND INSTALLATION | | | INSTRUCTIONS FOR VENT LESS GAS FIRE | | | PLACE. | | | | | | 2)NEED DETAILED MANUFACTURE'S | | | SPECIFICATION'S AND INSTALLATION | | | INSTRUCTIONS FOR TANKLESS GAS WATER | | | HEATER. | | | | | | 3) SHOW LOCATION ON MECHANICAL PLANS FOR | | | TANKLESS GAS WATER HEATER. | | | | | | 4) PROVIDE COMBUSTION AIR AND COMBUSTION | | | AIR CALCULATIONS ON MECHANICAL PLANS FOR | | | GAS CLOTHES DRYER.PER 2004 FBC/R M1701.1 | | | | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2007-07-18 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-07-18 |
Time |
07:09 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-07-18 |
Time |
07:09 |
Sent To |
|
|
| Notes |
| 2007-07-18 07:09:51 | REVISED WATER HEATER TO ON DEMAND TYPE. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2006-06-06 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-06-06 |
Time |
15:58 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-06-06 |
Time |
15:58 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-03-24 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-03-24 |
Time |
08:42 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2006-03-24 |
Time |
08:42 |
Sent To |
Z |
|
| Notes |
| 2006-03-24 00:00:00 | DENIED; | | | 1.THE AUTOMATIC CLOTHES WASHER CANNOT | | | RUN THRU THE MASTER BATHROOM GROUP SEC. | | | 909.1. ( MARKED IN RED) | | | 2.PAGE A-12 | | | GAS APPLIANCES. VENTILATION ACCORDING TO | | | 2004 CODE NOT 2001. WHERE IS LISTED | | | WATER HEATER LOCATION? (STANDERD 50 GAL. | | | HEATER) | | | 3.TANKLESS WATER HEATER SHOWN OUTSIDE | | | KITCHEN MAYBE TO CLOSE TO KITCHEN | | | WINDOW. PLEASE CHECK MANUFACTURE | | | INSTALLATION RECOMMENDATIONS. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2006-05-25 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-05-25 |
Time |
10:36 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-05-25 |
Time |
10:36 |
Sent To |
I |
|
| Notes |
| 2006-05-25 00:00:00 | NOTE: MUST PULL A SEPERATE PERMIT FOR | | | POOL/SPA/SCREEN ENCLOSURE/DECK. | | | | | | NOTE: MUST PULL A SEPERATE PERMIT FOR | | | WALL/GATE/FENCE WITH EASEMENT APPROVAL | | | FROM CITY OF WEST PALM BEACH.IF ANY | | | OTHER UTILITY EASEMENT ON PROPERTY | | | (BELLSOUTH/ADELPHIA/FPL/FLORIDA PUBLIC | | | UTILITIES WILL BE NEEDED) IF APPLICABLE. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2006-03-27 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-04-24 |
Time |
09:33 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-03-27 |
Time |
07:35 |
Sent To |
M |
|
| Notes |
| 2006-03-27 00:00:00 | DENIED, | | | 1. MUST PROVIDE TWO CURRENT COPY OF | | | SURVEY SHOWING THE LOCATION OF THE | | | STRUCTURE WITH SETBACKS. | | | 2. THE STRUCTURE IS OVER THE HEIGHT | | | REQUIREMENT OF33FT. (ALLOWED 30FT FOR | | | STRUCTURE & 10% FOR CHIMNEY = 33FT). | | | | | | NOTE: MUST PULL A SEPERATE PERMIT FOR | | | POOL/SPA/SCREEN ENCLOSURE/DECK. | | | NOTE: MUST PULL A SEPERATE PERMIT FOR | | | WALL/GATE/FENCE WITH EASEMENT APPROVAL | | | FROM CITY OF WEST PALM BEACH.IF ANY | | | OTHER UTILITY EASEMENT ON PROPERTY | | | (BELLSOUTH/ADELPHIA/FPL/FLORIDA PUBLIC | | | UTILITIES WILL BE NEEDED) IF APPLICABLE. | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|