Plan Review Details - Permit 06031064
Plan Review Stops For Permit 06031064
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2006-05-08 Cont ID  
Sent By lursu Date 2006-05-08 Time 14:39 Rev Time 0.00
Received By jwitmer Date 2006-08-03 Time 16:44 Sent To  
Notes
2006-05-08 00:00:00PERMIT ATTACHED TO THE CORRECT ADDRESS
 FOR THE TEMP SALES TRAILER @9763
 BAYWINDS DR.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2006-08-31 Cont ID  
Sent By jwitmer Date 2006-08-31 Time 16:49 Rev Time 1.11
Received By jwitmer Date 2006-08-31 Time 16:49 Sent To  
Notes
2006-08-31 00:00:00CONT: LENNAR HOMES
 TEL: (561)790-0202
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 4TH REVIEW
 ACTION: DENIED
  
 1) WHEN RESUBMITTING PLANS PLEASE
 INDICATE THE REVISION & REMOVE & REPLACE
 ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET
 OR SPECIFICATION PAGE WHERE THE CHANGES
 CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. PLEASE CREATE (2) SETS OF PLANS
 FROM ALL THE LOOSE SHEETS. THANK YOU FOR
 YOUR ANTICIPATED COOPERATION.
 THIS STILL HAS NOT BEEN COMPLETED.
 WE ARE LOOKING FOR THE CONTRACTOR TO
 COMBINE ALL DOCUMENTS FOR PERMIT TO BE
 COLLATED INTO (2) SETS OF PLANS. THE
 SITE PLAN, LANDSCAPE PLANS, STATE
 APPROVED MANUFACTURED BUILDING,
 ARCHITECTURAL AND STRUCTURAL ALL
 COMBINED INTO A SINGLE PLAN SET (2)
 REQUIRED.
  
 2) FL S S 713.13
 NOTICE OF COMMENCEMENT, TO BE FILED
 WITH THE CLERK OF THE COURT BEFORE A
 PERMIT WILL BE ISSUED. NOTE: 713.13(2)
 IF THE WORK DESCRIBED IN THE NOTICE OF
 COMMENCEMENT IS NOT ACTUALLY COMMENCED
 WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF, SUCH NOTICE IS NULL & VOID.
  
 3) COMPLIED.
  
 4) COMPLIED.
  
 5) PROVISO: THE SALES TRAILER IS LOCATED
 IN A FLOOD ZONE.
 PROVIDE FLOOD ZONE ELEVATION
 CERTIFICATE FOR NEW CONSTRUTION WITH
 BASE FLOOD ELEVATION, CITY CODE REQUIRES
 AN ADDITIONAL 6".
 LETTER OF MAP REVISION- STUDY UNDER WAY.
  
 6) 3RD REQUEST, PLANS DO NOT PROVIDE
 ENOUGH INFORMATION AS TO ACCESSIBLE
 ROUTE, RAMPAGE STRUCTURAL PLANS FOR RAMP
 ACCESS TO SALES TRAILER. 11-4.1.3(1) AT
 LEAST ONE ACCESSIBLE ROUTTE COMPLYING
 WITH 11-4.3 SHALL CONNECT ACCESSIBLE
 BUILDING OR FACILITY ENETRANCES WITH ALL
 ACCESSIBLE SPACES AND ELEMENTS WITHIN
 THE BUILDING OR FACILITY.
 THE LANDSCAPE PLAN SHOWS AN ARIAL
 VIEW, BUT NO INFORMATION, NO DETAILS,
 AS TO HOW TO BUILD THE STAIRS RAMPS OR
 HANDRAILS.
 6A) ACCESSIBLE ROUTE AND RAMPAGE:
 NEITHER THE LANDSCAPE PLAN NOR THE A-1
 SHEET INDICATE WHAAT MATERIALS THE
 PARKING LOT, ACCESSIBLE AISLE OR
 WALKWAYS WILL CONSIST OF.DEFINITIONS
 11-3:ACCESSIBLE ROUTE . A CONTINUOUS
 UNOBSTRUCTED PATH CONNECTING ALL
 ACCESSIBLE ELEMENTS AND SPACES OF A
 BUILDING OR FACILITY. INTERIOR
 ACCESSIBLE ROUTES MAY INCLUDE CORRIDORS,
 FLOORS, RAMPS, ELEVATORS, LIFTS, AND
 CLEAR FLOOR SPACE AT FIXTURES. EXTERIOR
 ACCESSIBLE ROUTES MAY INCLUDE PARKING
 ACCESS AISLES, CURB RAMPS, CROSSWALKS AT
 VEHICULAR WAYS, WALKS, RAMPS AND LIFTS.
 IN REVIEWING THE SITE PLAN AND SHEET
 LP-1 SOME ONE HAS HAND WRITTEN IN PAVERS
 ON THE WALKWAY. ONLY THE DESIGNER OF
 RECORD CAN MAKE CHANGES TO THEIR SHEETS.
 THE ISSUE OF WHAT MATERIAL THE PARKING
 LOT IS MADE OF WAS NOT ANSWERED.
 THE SITE PLAN INDICATES IT IS THE
 DESIGN OF LAND DESIGN SOUTH NOT SIGNED
 NOR SEALED. ALSO NOTE THERE IS NO
 CERTIFICATE OF AUTHORIZATION NUMBER
 LOCATED ON PLANS FOR THIS FIRM.
 481.219 F.S.CERTIFICATE OF
 AUTHORIZATION.THE TITLE BLOCK FOR ANY
 SHEET BEARING THE NAME OF AN ARCHITECT
 PRACTICING UNDER A FICTITIOUS NAME, A
 CORPORATION, OR A PARTNERSHIP, OFFERING
 ARCHITECTURAL SERVICES, SHALL INCLUDE
 THE CERTIFICATE OF AUTHORIZATION
 NUMBER.ADD THE NUMBER TO EACH SHEET.
 THIS MAY BE ADDED BY HAND.
  
 6B) COMPLIED.
  
 6C) COMPLIED.
  
 6D) COMPLIED.
  
 6E) COMPLIED.
  
 6F) COMPLIED.
  
 6G) COMPLIED.
  
 7) COMPLIED.
  
 8) COMPLIED.
  
 9) COMPLIED.
  
 10) COMPLIED.
  
 11) COMPLIED.
  
 12) COMPLIED.
  
 BUILDING PROVISO:
  
 109.3.10* IMPACT OF CONSTRUCTION. ALL
 CONSTRUCTION ACTIVITY REGULATED BY THIS
 CODE SHALL BE PERMORMED IN A MANNER SO
 AS NOT TO ADVERSELY IMPACT THE CONDITION
 OF ADJACENT PROPERTY, UNLESS SUCH
 ACTIVITY IS PERMITTED TO AFFECT SAID
 PROPERTY PURSUANT TO A CONSENT BY THE
 APPLICABLE PROPERTY OWNER, UNDER TERMS &
 CONDITIONS AGREEABLE TO THE APPLICABLE
 PROPERTY OWNER.THIS INCLUDES BUT IS NOT
 LIMITED TO THE CONTROL OF DUST, NOISE,
 WATER OR DRAINAGE RUN-OFF, DEBRIS, AND
 THE STORAGE OF CONSTRUCTION MATERIALS.
 NEW CONSTRUCTION ACTIVITY SHALL NOT
 ADVERSELY IMPACT HISTORIC SURFACE WATER
 DRAINAGE FLOWS SERVING ADJACENT
 PROPERTIES, & MAY REQUIRE SPECIAL
 DRAINAGE DESIGN COMPLYING WITH
 ENGINEERING STANDARDS TO PRESERVE THE
 POSITIVE PATTERNS OF THE AFFECTED SITES.
 ACCORDINGLY, DEVELOPERS, CONTRACTORS,
 AND OWNERS OF ALL NEW RESIDENTIAL
 DEVELOPMENT, INCLUDING ADDITIONS, POOLS,
 PATIOS, DRIVEWAYS, DECKS, OR SIMILAR
 ITEMS, ON EXISTING PROPERTIES RESULTING
 IN A DECREASE IN EXCESS OF 800SQ FT OF
 PERMEABLE LAND AREA ON ANY PARCELL SHALL
 AS A PERMIT CONDITION, PROVIDE A
 PROFESSIONALLY PREPARED DRAINAGE PLAN
 CLEARLY INDICATING COMPLIANCE WITH THIS
 PARAGRAPH. UPON COMPLETION OF THE
 IMPROVEMENT, A CERTIFICATE FROM A
 LICENSED ENGINEER SHALL BE SUBMITTED TO
 THE INSPECTOR IN ORDER TO RECEIVE
 APPROVAL OF THE FINAL INSPECTION.
  
 109.3.10.1 HURICANE PROTECTION.
 IT SHALL BE UNLAWFUL FOR ANY PERSON TO
 ALLOW CONSTRUCTION RELATED MATERIALS
 EQUIPMENT AND DEBRIS TO REMAIN LOOSE OR
 OTHERWISE UNSECURED AT A CONSTRUCTION
 SITE FROM 24 HRS. AFTER A HURRICANE
 WATCH HAS BEEN ISSUED UNTIL THE
 HURRICANE WATCH OR WARNING HAS BEEN
 LIFTED. ALL SUCH CONSTRUCTION MATERIALS,
 EQUIPMENT AND DEBRIS SHALL BE EITHER
 REMOVED FROM THE CONSTRUCTION SITE OR
 SECURED IN SUCH A MANNER AS TO MINIMIZE
 THE DANGER OF SUCH CONSTRUCTION
 MATERIALS, EQUIPMENT AND DEBRIS CAUSING
 DAMAGE TO PERSONS OR PROPERTY FROM HIGH
 WINDS.
 ANY PERSONS WHO FAILS TO COMPLY TO
 REMOVE OR SECURE THE CONSTRUCTION
 MATERIALS EQUIPMENT AND DEBRIS WITHIN
 24 HRS AFTER A HURRICANE WATCH HAS BEEN
 ISSUED SHALL BE SUBJECT TO A FINE NOT TO
 EXCEED $500.00.
 IN ADDITION TO THE ABOVE, A LICENSED
 CONTRACTOR WHO VIOLATES THIS SECTION
 SHALL BE SUBJECT TO DISCIPLINE PURSUANT
 TO SECTION 113 OF THIS CHAPTER.
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2006-08-03 Cont ID  
Sent By jwitmer Date 2006-08-03 Time 16:44 Rev Time 2.22
Received By jwitmer Date 2006-08-03 Time 16:44 Sent To  
Notes
2006-08-03 00:00:00CONT: LENNAR HOMES
 TEL: (561)790-0202
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 3RD REVIEW
 ACTION: DENIED
  
 1) WHEN RESUBMITTING PLANS PLEASE
 INDICATE THE REVISION & REMOVE & REPLACE
 ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET
 OR SPECIFICA TION PAGE WHERE THE CHANGES
 CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. PLEASE CREATE (2) SETS OF PLANS
 FROM ALL THE LOOSE SHEETS. THANK YOU FOR
 YOUR ANTICIPATED
 COOPERATION.
  
 2) FL S S 713.13
 NOTICE OF COMMENCEMENT, TO BE FILED
 WITH THE CLERK OF THE COURT BEFORE A
 PERMIT WILL BE ISSUED. NOTE: 713.13(2)
 IF THE WORK DESCRIBED IN THE NOTICE OF
 COMMENCEMENT IS NOT ACTUALLY COMMENCED
 WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF, SUCH NOTICE IS NULL & VOID.
  
 3) COMPLIED.
  
 4) COMPLIED.
  
 5) 3RD REQUEST, THE SALES TRAILER IS
 LOCATED IN A FLOOD ZONE "AO". PLEASE
 PROVIDE THE ELEVATION THAT THE BOTTOM OF
 THE SALES TRAILER WILL BE SET AT.
 PROVIDE FLOOD ZONE ELEVATION CERTIFICATE
 FOR NEW CONSTRUCTION WITH BASE FLOOD
 ELEVATION. REQUIRED INFO:
 "AO FLOOD ZONE"
 PANEL# 120192 0150 A
 DATE 2/1/79
 IF LOMAR FOR SITE PLEASE PROVIDE LOMAR.
  
 THE ELEVATION CERTIFICATE PROVIDED IS
 NOT FOR 8763 BAYWINDS DR BUT FOR 9770
 BOWLINE DR.
  
 NOTE IS A DOCUMENT REQUIRED BEFORE A
 C. O. WILL BE ISSUED. THE BUILDING
 SHOULD NOT BE SET MAKING IT THAT THE
 SURVEYOR CAN NOT PROVIDE A CERTIFICATE
 AT THIS TIME.
  
 6) 2ND REQUEST, PLANS DO NOT PROVIDE
 ENOUGH INFORMATION AS TO ACCESSIBLE
 ROUTE, RAMPAGE STRUCTURAL PLANS FOR RAMP
 ACCESS TO SALES TRAILER. 11-4.1.3(1) AT
 LEAST ONE ACCESSIBLE ROUTTE COMPLYING
 WITH 11-4.3 SHALL CONNECT ACCESSIBLE
 BUILDING OR FACILITY ENETRANCES WITH ALL
 ACCESSIBLE SPACES AND ELEMENTS WITHIN
 THE BUILDING OR FACILITY.
 THE LANDSCAPE PLAN SHOWS AN ARIAL
 VIEW, BUT NO INFORMATION, NO DETAILS,
 AS TO HOW TO BUILD THE STAIRS RAMPS OR
 HANDRAILS.
 6A) ACCESSIBLE ROUTE AND RAMPAGE:
 NEITHER THE LANDSCAPE PLAN NOR THE A-1
 SHEET INDICATE WHAAT MATERIALS THE
 PARKKING LOT, ACCESSIBLE AISLE OR
 WALKWAYS WILL CONSIST OF.DEFINITIONS
 11-3:ACCESSIBLE ROUTE . A CONTINUOUS
 UNOBSTRUCTED PATH CONNECTING ALL
 ACCESSIBLE ELEMENTS AND SPACES OF A
 BUILDING OR FACILITY. INTERIOR
 ACCESSIBLE ROUTES MAY INCLUDE CORRIDORS,
 FLOORS, RAMPS, ELEVATORS, LIFTS, AND
 CLEAR FLOOR SPACE AT FIXTURES. EXTERIOR
 ACCESSIBLE ROUTES MAY INCLUDE PARKING
 ACCESS AISLES, CURB RAMPS, CROSSWALKS AT
 VEHICULAR WAYS, WALKS, RAMPS AND LIFTS.
 6B) RAMP:A-1 INDICATES THE BOTTOM
 LANDING TO BE 18". 11-4.8.4(2)ALL
 LANDINGS ON RAMPS SHALL BE NOT LESS THAN
 60 INCHES (1524 MM) CLEAR, AND THE
 BOTTOM OF EACH RAMP SHALL HAVE NOT LESS
 THAN 72 INCHES (1829 MM) OF STRAIGHT AND
 LEVEL CLEARANCE.
 6C) THE PLANS INDICATE THE DECK TO BE
 24'X8'. THE FRONT OF THE DECK INDICATES
 (2) 2X12 WITH A TOTAL OF 4 POST CARRYING
 THE WEIGHT OF THE DECK WHEREAS THE BACK
 OF THE DECK ONLY INDICATE (1) 2X12 AND
 (2) END POST, ISN'T THE LOADS TO BE
 CARRIED THE SAME. PLANS DO NOT SHOW
 FLOOR JOIST CONNECTIONS IF NAILS OR IF
 JOIST HANGERS ARE REQUIRED.
 6D) PLANS DO NOT INDICATE IF WOOD IS TO
 BE PRESSURE TREATED. 2304.11.4 WOOD IN
 CONTACT WITH THE GROUND OR FRESH WATER.
 WOOD IN CONTACT WITH THE GROUND (EXPOSED
 EARTH) THAT SUPPORTS PERMANENT
 STRUCTURES SHALL BE OF NATURALLY DURABLE
 (SPECIES FOR BOTH DECAY AND TERMITE
 RESISTANCE) OR PRESERVATIVE-TREATED WOOD
 USING WATER-BORNE PRESERVATIVES AND
 SHALL BE TREATED IN ACCORDANCE WITH AWPA
 C2, C9 OR OTHER APPLICABLE AWPA STANDARD
 FOR SOIL OR FRESH WATER CONTACT, WHERE
 USED IN THE LOCATIONS SPECIFIED IN
 SECTIONS 2304.11.4.1 AND 2304.11.4.2 .
 2304.11.2 WOOD USED ABOVE GROUND.
 WOOD INSTALLED ABOVE GROUND IN THE
 LOCATIONS SPECIFIED IN SECTIONS
 2304.11.2.1 THROUGH 2304.11.2.6 SHALL BE
 NATURALLY DURABLE WOOD OR
 PRESERVATIVE-TREATED WOOD THAT USES
 WATER-BORNE PRESERVATIVES, AND SHALL BE
 TREATED IN ACCORDANCE WITH AWPA C2 OR C9
 OR APPLICABLE AWPA STANDARDS FOR
 ABOVE-GROUND USE.
 6D)THE STAIRS ARE DIMENSIONED AS 7 1/2"
 RISERS.1009.3STAIR RISER HEIGHTS SHALL
 BE 7 INCHES (178 MM) MAXIMUM AND 4
 INCHES (102 MM) MINIMUM. STAIR TREAD
 DEPTHS SHALL BE 11 INCHES (279 MM)
 MINIMUM.
 6E) PLANS INDICATE A 31" RISE FROM GRADE
 TO THE TOP OF DECK. GUARDRAILS 1012.1
 GUARDS SHALL BE LOCATED ALONG OPEN-SIDED
 WALKING SURFACES, MEZZANINES, INDUSTRIAL
 EQUIPMENT PLATFORMS, STAIRWAYS, RAMPS
 AND LANDINGS WHICH ARE LOCATED MORE THAN
 30 INCHES (762 MM) ABOVE THE FLOOR OR
 GRADE BELOW.
 6F)1012.3 OPENING LIMITATIONS.
 OPEN GUARDS SHALL HAVE BALUSTERS OR
 ORNAMENTAL PATTERNS SUCH THAT A
 4-INCH-DIAMETER (102 MM) SPHERE CANNOT
 PASS THROUGH ANY OPENING UP TO A HEIGHT
 OF 34 INCHES (864 MM). FROM A HEIGHT OF
 34 INCHES (864 MM) TO 42 INCHES (1067
 MM) ABOVE THE ADJACENT WALKING SURFACES,
 A SPHERE 8 INCHES (203 MM) IN DIAMETER
 SHALL NOT PASS.
 6G) HANDRAILS:11-4.9.4(3)THE CLEAR SPACE
 BETWEEN HANDRAILS AND WALL SHALL BE 1?
 INCHES (38 MM).
  
 7)COMPLIED.
  
 8) COMPLIED.
  
 9) SAME AS 6B REQUIRING A 72" BOTTOM
 LANDING ON RAMP.
  
 10) COMPLIED.
  
 11) HANDRAILS, SEE COMMENT 6G) CLEAR
 DISTANCE BETWEEN THE HANDRAIL AND
 PICKETS.
  
 12) NEW COMMENT: SHEET A-1 INDICATES
 PLANS DESIGNED TO THE 2001 FBC.
  
 BUILDING PROVISO:
 109.3.10* IMPACT OF CONSTRUCTION. ALL
 CONSTRUCTION ACTIVITY REGULATED BY THIS
 CODE SHALL BE PERMORMED IN A MANNER SO
 AS NOT TO ADVERSELY IMPACT THE CONDITION
 OF ADJACENT PROPERTY, UNLESS SUCH
 ACTIVITY IS PERMITTED TO AFFECT SAID
 PROPERTY PURSUANT TO A CONSENT BY THE
 APPLICABLE PROPERTY OWNER, UNDER TERMS &
 CONDITIONS AGREEABLE TO THE APPLICABLE
 PROPERTY OWNER.THIS INCLUDES BUT IS NOT
 LIMITED TO THE CONTROL OF DUST, NOISE,
 WATER OR DRAINAGE RUN-OFF, DEBRIS, AND
 THE STORAGE OF CONSTRUCTION MATERIALS.
 NEW CONSTRUCTION ACTIVITY SHALL NOT
 ADVERSELY IMPACT HISTORIC SURFACE WATER
 DRAINAGE FLOWS SERVING ADJACENT
 PROPERTIES, & MAY REQUIRE SPECIAL
 DRAINAGE DESIGN COMPLYING WITH
 ENGINEERING STANDARDS TO PRESERVE THE
 POSITIVE PATTERNS OF THE AFFECTED SITES.
 ACCORDINGLY, DEVELOPERS, CONTRACTORS,
 AND OWNERS OF ALL NEW RESIDENTIAL
 DEVELOPMENT, INCLUDING ADDITIONS, POOLS,
 PATIOS, DRIVEWAYS, DECKS, OR SIMILAR
 ITEMS, ON EXISTING PROPERTIES RESULTING
 IN A DECREASE IN EXCESS OF 800SQ FT OF
 PERMEABLE LAND AREA ON ANY PARCELL SHALL
 AS A PERMIT CONDITION, PROVIDE A
 PROFESSIONALLY PREPARED DRAINAGE PLAN
 CLEARLY INDICATING COMPLIANCE WITH THIS
 PARAGRAPH. UPON COMPLETION OF THE
 IMPROVEMENT, A CERTIFICATE FROM A
 LICENSED ENGINEER SHALL BE SUBMITTED TO
 THE INSPECTOR IN ORDER TO RECEIVE
 APPROVAL OF THE FINAL INSPECTION.
  
 109.3.10.1 HURICANE PROTECTION.
 IT SHALL BE UNLAWFUL FOR ANY PERSON TO
 ALLOW CONSTRUCTION RELATED MATERIALS
 EQUIPMENT AND DEBRIS TO REMAIN LOOSE OR
 OTHERWISE UNSECURED AT A CONSTRUCTION
 SITE FROM 24 HRS. AFTER A HURRICANE
 WATCH HAS BEEN ISSUED UNTIL THE
 HURRICANE WATCH OR WARNING HAS BEEN
 LIFTED. ALL SUCH CONSTRUCTION MATERIALS,
 EQUIPMENT AND DEBRIS SHALL BE EITHER
 REMOVED FROM THE CONSTRUCTION SITE OR
 SECURED IN SUCH A MANNER AS TO MINIMIZE
 THE DANGER OF SUCH CONSTRUCTION
 MATERIALS, EQUIPMENT AND DEBRIS CAUSING
 DAMAGE TO PERSONS OR PROPERTY FROM HIGH
 WINDS.
 ANY PERSONS WHO FAILS TO COMPLY TO
 REMOVE OR SECURE THE CONSTRUCTION
 MATERIALS EQUIPMENT AND DEBRIS WITHIN
 24 HRS AFTER A HURRICANE WATCH HAS BEEN
 ISSUED SHALL BE SUBJECT TO A FINE NOT TO
 EXCEED $500.00.
 IN ADDITION TO THE ABOVE, A LICENSED
 CONTRACTOR WHO VIOLATES THIS SECTION
 SHALL BE SUBJECT TO DISCIPLINE PURSUANT
 TO SECTION 113 OF THIS CHAPTER.
  
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-06-20 Cont ID  
Sent By jwitmer Date 2006-06-20 Time 08:03 Rev Time 0.77
Received By jwitmer Date 2006-06-20 Time 07:38 Sent To  
Notes
2006-06-20 00:00:00CONT: LENNAR HOMES
 TEL: (561)790-0202
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 2ND REVIEW
 ACTION: DENIED
  
 1) WHEN RESUBMITTING PLANS PLEASE
 INDICATE THE REVISION & REMOVE & REPLACE
 ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUM- BER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET
 OR SPECIFICA TION PAGE WHERE THE CHANGES
 CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 2) FL S S 713.13
 NOTICE OF COMMENCEMENT, TO BE FILED
 WITH THE CLERK OF THE COURT BEFORE A
 PERMIT WILL BE ISSUED. NOTE: 713.13(2)
 IF THE WORK DESCRIBED IN THE NOTICE OF
 COMMENCEMENT IS NOT ACTUALLY COMMENCED
 WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF, SUCH NOTICE IS NULL & VOID.
  
 3) THE LANDSCAPE ARCHITECURAL PLANS
 (SITE PLAN) DO NOT HAVE A RAISED SEAL
 NOR ARE THEY SIGNED.PLANS,
 SPECIFICATIONS,REPORTS OR OTHER
 DOCUMENTS PREPARED BY THE DESIGN
 PROFESSIONAL AND BEING FILED FOR
 PUBLIC RECORD SHALL HAVE THE SIGNATURE
 AND SEAL OF THE DESIGN PROFESSIONAL
 AFFIXED TO THE DOCUMENT.
 FL STATE STAT: 61G15-23.002 ENGINEERS
 FL ATATE STAT: 61G16.003 ARCHITECTS
  
 4)COMPLIED.
  
 5)SALES TRAILER IS LOCATED IN A FLOOD
 ZONE "AO". PROVIDE THE HEIGHT THAT THE
 BOTTOM OF THE SALES TRAILER IS TO BE SET
 AT.PROVIDE FLOOD ZONE ELEVATION
 CERTIFICATE FOR NEW CONSTRUTION WITH
 BASE FLOOD ELEVATION.
 REQUIRED INFO:
 "AO" FLOOD ZONE
 PANEL# 120192 0150 A
 2/1/79
 IF LOMAR FOR SITE PROVIDE COPY OF LOMAR
  
  
 6) PLANS DO NOT PROVIDE ENOUGH
 INFORMATION AS TO ACCESSIBLE ROUTE,
 RAMPAGE STRUCTURAL PLANS FOR RAMP ACCESS
 TO SALES TRAILER. 11-4.1.3(1) AT LEAST
 ONE ACCESSIBLE ROUTTE COMPLYING WITH
 11-4.3 SHALL CONNECT ACCESSIBLE BUILDING
 OR FACILITY ENETRANCES WITH ALL
 ACCESSIBLE SPACES AND ELEMENTS WITHIN
 THE BUILDING OR FACILITY.
 THE LANDSCAPE PLAN SHOWS AN ARIAL
 VIEW, BUT NO INFORMATION, NO DETAILS,
 AS TO HOW TO BUILD THE STAIRS RAMPS OR
 HANDRAILS.
  
 7) 11-4.8.3. CLEAR WIDTH. THE MINIMUM
 CLEAR WIDTH OF A RAMP SHALL BE 36".
 EXCEPTION: RAMPS THAT ARE PART OF A
 REQUIRED MEANS OF EGRESS SHALL NOT BE
 LESS THAN 44 INCHES WIDE.
  
 8) 11-4.8.2 SLOPE & RISE. THE LEAST
 POSSIBLE SLOPE SHALL BE USED FOR ANY
 RAMP. THE MAXIMUM SLOPE FOR A RAMP IN
 NEW CONSTRUCTION SHALL BE 1 TO 12. THE
 MAXIMUM RISE FOR RUN SHALL BE 30" (SEE
 FIGURE 16).
  
 9) 11-4.8.4.(2) LANDINGS. ALL LANDINGS
 ON RAMPS SHALL NOT BE LESS THAN 60"
 CLEAR, & THE BOTTOM OF EACH RAMP SHALL
 HAVE NOT LESS THAN 72" OF STRAIGHT &
 LEVEL CLEARENCE.
  
 10) 11-4.8.4(3) IF RAMPS CHANGE DIREC-
 TION AT LANDINGS, THE MINIMUM LANDING
 SIZE SHALL BE 60" X 60".
  
 11) 11.4.8.5. HANDRAILS: IF A RAMP HAS A
 RISE GREATER THAN 6" OR A HORIZONTAL
 PROJECTION GREATER THAN 72", THEN IT
 SHALL HAVE HANDRAILS ON BOTH SIDES.
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-05-08 Cont ID  
Sent By jwitmer Date 2006-05-08 Time 08:35 Rev Time 2.22
Received By jwitmer Date 2006-05-08 Time 08:35 Sent To  
Notes
2006-05-08 00:00:00BUILDING PLAN REVIEW
 PERMIT: 06031064
 ADD: 9787 MIDSHIP WAY
 CONT: LENNAR HOMES
 TEL: (561)790-0202
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
  
 1) WHEN RESUBMITTING PLANS PLEASE
 INDICATE THE REVISION & REMOVE & REPLACE
 ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUM- BER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET
 OR SPECIFICA TION PAGE WHERE THE CHANGES
 CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 2) FL S S 713.13
 NOTICE OF COMMENCEMENT, TO BE FILED
 WITH THE CLERK OF THE COURT BEFORE A
 PERMIT WILL BE ISSUED. NOTE: 713.13(2)
 IF THE WORK DESCRIBED IN THE NOTICE OF
 COMMENCEMENT IS NOT ACTUALLY COMMENCED
 WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF, SUCH NOTICE IS NULL & VOID.
  
 3) THE LANDSCAPE ARCHITECURAL PLANS
 (SITE PLAN) DO NOT HAVE A RAISED SEAL
 NOR ARE THEY SIGNED.PLANS,
 SPECIFICATIONS,REPORTS OR OTHER
 DOCUMENTS PREPARED BY THE DESIGN
 PROFESSIONAL AND BEING FILED FOR
 PUBLIC RECORD SHALL HAVE THE SIGNATURE
 AND SEAL OF THE DESIGN PROFESSIONAL
 AFFIXED TO THE DOCUMENT.
 FL STATE STAT: 61G15-23.002 ENGINEERS
 FL ATATE STAT: 61G16.003 ARCHITECTS
  
 4) THERE ARE ONLY ONE SET OF
 ARCHITECRURAL PLANS (2) SETS ARE
 REQUIRED.
  
 5)SALES TRAILER IS LOCATED IN A FLOOD
 ZONE "AO". PROVIDE THE HEIGHT THAT THE
 BOTTOM OF THE SALES TRAILER IS TO BE SET
 AT.PROVIDE FLOOD ZONE ELEVATION
 CERTIFICATE FOR NEW CONSTRUTION WITH
 BASE FLOOD ELEVATION.
  
 6) PLANS DO NOT PROVIDE ENOUGH
 INFORMATION AS TO ACCESSIBLE ROUTE,
 RAMPAGE STRUCTURAL PLANS FOR RAMP ACCESS
 TO SALES TRAILER. 11-4.1.3(1) AT LEAST
 ONE ACCESSIBLE ROUTTE COMPLYING WITH
 11-4.3 SHALL CONNECT ACCESSIBLE BUILDING
 OR FACILITY ENETRANCES WITH ALL
 ACCESSIBLE SPACES AND ELEMENTS WITHIN
 THE BUILDING OR FACILITY.
  
 7) 11-4.8.3. CLEAR WIDTH. THE MINIMUM
 CLEAR WIDTH OF A RAMP SHALL BE 36".
 EXCEPTION: RAMPS THAT ARE PART OF A
 REQUIRED MEANS OF EGRESS SHALL NOT BE
 LESS THAN 44 INCHES WIDE.
  
 8) 11-4.8.2 SLOPE & RISE. THE LEAST
 POSSIBLE SLOPE SHALL BE USED FOR ANY
 RAMP. THE MAXIMUM SLOPE FOR A RAMP IN
 NEW CONSTRUCTION SHALL BE 1 TO 12. THE
 MAXIMUM RISE FOR RUN SHALL BE 30" (SEE
 FIGURE 16).
  
 9) 11-4.8.4.(2) LANDINGS. ALL LANDINGS
 ON RAMPS SHALL NOT BE LESS THAN 60"
 CLEAR, & THE BOTTOM OF EACH RAMP SHALL
 HAVE NOT LESS THAN 72" OF STRAIGHT &
 LEVEL CLEARENCE.
  
 10) 11-4.8.4(3) IF RAMPS CHANGE DIREC-
 TION AT LANDINGS, THE MINIMUM LANDING
 SIZE SHALL BE 60" X 60".
  
 11) 11.4.8.5. HANDRAILS: IF A RAMP HAS A
 RISE GREATER THAN 6" OR A HORIZONTAL
 PROJECTION GREATER THAN 72", THEN IT
 SHALL HAVE HANDRAILS ON BOTH SIDES.
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2006-08-23 Cont ID  
Sent By dpalmer Date 2006-08-23 Time 20:03 Rev Time 0.00
Received By dpalmer Date 2006-08-23 Time 19:52 Sent To  
Notes
2006-08-23 00:00:00**** UNSAT 4TH REVIEW *****
  
 1) NOTE: PLEASE SEE NOTES FROM PREVIOUS
 REVIEW STILL ARE IN NEED OF ADDRESSING.
 PLEASE SEE THE EXACT SAME RISER DIAGRAM
 WAS SUBMITTED BACK FOR REVIEW.
 PLEASE SEE THIS SHEET WAS DATED 5/8/06
 PLEASE SUBMIT AND PLACE ALL PLANS INTO
 COMPLETE SETS FOR REVIEW AND STAMPING.
 PLEASE SEE EACH TRADE SETS ARE SEPARATE
 AND NOT PART OF A COMPLETE PACKAGE FOR
 EACH SET.
  
 2) NOTE:A 4X FEE FOR THE PLAN REVIEW
 PORTION OF THE PERMIT FEE IS NOW
 ASSESSED DUE TO REPEAT COMMENTS FOR CODE
 COMPLIANCE PER FS 553.80(2)(B).
 PLEASE SEE A NOTICE WAS PLACED IN THE
 PERMIT PACKAGE ON THE LAST SUBMITTIAL.
 A FEE OF $192.00 IS NOW DUE AND MUST BE
 PAID BEFORE PLANS CAN BE RESUBMITTED.
 IF PLANS ARE NOT ADDRESSED , A FEE IS
 ASSESSED EACH TIME.
  
 ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE
 PICKED UP FOR CORRECTIONS, PLEASE BE
 SURE TO COMPLETELY REMOVE ALL OLD/VOIDED
 SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW
 AND STAMPING. DO NOT LEAVE ANY
 OLD/VOIDED SHEETS IN SETS.
 PLEASE KNOW ONLY ONE SET OF THE
 OLD/VOIDED SHEETS SHOULD BE SUBMITTED
 FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND
 AVOID ANY DELAYS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CONSTUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2006-07-21 Cont ID  
Sent By dpalmer Date 2006-07-21 Time 16:25 Rev Time 0.00
Received By dpalmer Date 2006-07-21 Time 16:16 Sent To  
Notes
2006-07-21 00:00:00******* UNSAT 3RD REVIEW ******
  
 1) NOTE: PLEASE SEE THIS SUBMITTAL NOW
 CONTAINS THE RISER DIAGRAM AND ONCE
 AGAIN IT STILL DOES NOT CORRELATE WITH
 STATE APPROVED PLANS.
 PLEASE SEE PLANS.
  
 2) NOTE: PLEASE BE SURE THEPERSON
 TAKING REPSONSIBILTY FOR PLANS AND
 DESIGN FOR SERVICE PRINTS DRAWN BY:
 PRINTED NAME AND SIGNATURE.
 FBC 106.1.2 ADMIN SECT.
  
 3) NOTE: PLEASE SEE A LETTER FROM GE
 CAPITAL ISNOTING REVISED PLANS TO
 FOLLOW FOR NEW ADDED EXIT/ EM LTS.
 THESE PLANS COULD NOT BE LOCATED IN SETS
 TO ADDRESS FIRE REVIEWS COMMENTS.
  
 4) NOTE: PLEASE SEE BLDG REVIEW
 COMMENTS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2006-06-18 Cont ID  
Sent By dpalmer Date 2006-06-18 Time 14:37 Rev Time 0.00
Received By dpalmer Date 2006-06-18 Time 14:30 Sent To  
Notes
2006-06-18 00:00:00***** UNSAT *******
  
 1) NOTE: PLEASE SEE PLANS CAME BACK
 WITHOUT ELECTRICAL RISER DIAGRAM
 SUBMITTED FOR REVIEW. NEED TO CORRELATE
 WITH ELECTRICAL FOR TRAILER.
 215.5
  
 2) NOTE: PLEASE SEE FIRE REVIEW NOTES
 FOR EM LTS,AND RESPONSE LTR MENTIONS
 THESE WILL BE INSTALLED BEFORE, FINAL,
 HOWEVER PLEASE KNOW, THESE NEED TO BE ON
 PLANS AT THIS TIME.
  
 3) NOTE: PLEASE SEE ADDRESS ON
 APPLICATIONWAS CHANGED TO 9787 MIDSHIP
 WAY, WHERE ADDRESSING REVIEWER HAS GIVEN
 THE ADDRESS OF 9763 BAYWINDS.
 IF THERE IS A CONFLICT, PLEASE CONTACT
 ADDRESSING REVIEWER.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-04-14 Cont ID  
Sent By dpalmer Date 2006-04-14 Time 07:57 Rev Time 0.00
Received By dpalmer Date 2006-04-14 Time 07:42 Sent To  
Notes
2006-04-14 00:00:00*** UNSAT****
  
  
 PLEASE KNOW, PLANS WILL BE COMING BACK
 FOR BLDG COMMENTS, PLEASE SUBMIT THE
 FOLLOWING INFORMATION .
  
  
 1) NOTE: PLEASE SUBMIT AN ELECTRICAL
 RISER DIAGRAM FOR SERVICE AND HOOK UP OF
 TEMPORARY SALES TRAILER.
 THIS SHOULD REFLECT SIZE SERVICE FOR
 DEMAND OF TRAILER AND CORRELATE.
 PLEASE ALSO INDICATE THE GROUNDING AT
 TRAILER AND ANY DISCONNECTING MEANS AT
 TRAILER (IF REQUIED).
  
 215.5,250,550
  
 PLEASE SUBMIT THE ABBOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status P Date 2006-09-26 Cont ID  
Sent By mwennerg Date 2006-09-26 Time 11:11 Rev Time 0.00
Received By mwennerg Date 2006-09-26 Time 11:11 Sent To  
Notes
2006-09-26 00:00:00ADDRESS REQUIRED ON STRUCTURE THAT SHALL
 MEET THE REQUIREMENTS FOR COMMERCIAL
 BUILDINGS.

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status F Date 2006-08-16 Cont ID  
Sent By mwennerg Date 2006-08-16 Time 15:56 Rev Time 0.00
Received By mwennerg Date 2006-08-16 Time 15:56 Sent To  
Notes
2006-08-16 00:00:00***DENIED***
  
 1) PLEASE SEE LAST FIRE REVIEW AND
 ELECTRICAL COMMENTS.
  
  
 MIKE WENNERGREN, CAPTAIN/WPBFR
 FIRE PLAN REVIEW (561) 805-6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2006-06-27 Cont ID  
Sent By mwennerg Date 2006-06-27 Time 10:39 Rev Time 0.00
Received By mwennerg Date 2006-06-27 Time 10:39 Sent To  
Notes
2006-06-27 00:00:00***DENIED***
  
 PLEASE NOTE THAT COMMENTS FROM LAST FIRE
 REVIEW DO NOT APPEAR TO BE ADDRESSED.
  
 1) LIFE SAFETY SHALL COMPLY WITH NFPA
 101, AND NFPA 1, 2003 EDITIONS.
  
 2) INTERIOR FINISH CLASSIFICATION FOR
 TEMPORARY STRUCTURES TO BE CLASS A ONLY.
  
  
 3) HOW LONG WILL THIS STRUCTURE BE UP?
 THIS CODE ALLOWS FOR 180 DAYS.
  
 4) PLEASE SHOW LOCATION OF EMERGENCY
 LIGHTING FACILITIES ON PLANS.
  
  
 MIKE WENNERGREN, CAPTAIN/WPBFR
 FIRE PLAN REVIEW (561) 805-6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2006-05-24 Cont ID  
Sent By nmccray Date 2006-05-24 Time 14:14 Rev Time 0.00
Received By nmccray Date 2006-05-24 Time 14:14 Sent To  
Notes
2006-05-24 00:00:00********DENIED********************
  
 1) SHALL COMPLY WITH NFPA 101 LIFE
 SAFETY CODE, 2003 EDITION AND NFPA 1
 UNIFORM FIRE CODE, 2003 EDITION.
  
 2) THE INTERIOR FINISH IN TEMPORARY
 STRUCTURE SHALL BE CLASS A ONLY.
  
 3) HOW LONG WILL THIS TEMPORARY
 STRUCTURE BE UP. THIS CODE ALLOWS 180
 DAYS
  
 4) PLEASE SHOW EMERGENCY LIGHTS IN
 TRAILER ON THE FLOOR PLAN.
  
  
 NATE MCCRAY, ASSISTANT FIRE MARSHAL
 561-804-4754

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-08-17 Cont ID  
Sent By adarroug Date 2006-08-17 Time 14:08 Rev Time 0.00
Received By adarroug Date 2006-08-17 Time 14:08 Sent To  
Notes
2006-08-23 00:00:00TO "COMM" BD#13
2006-08-17 00:00:00WAITING FOR "COMM" BD

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-07-05 Cont ID  
Sent By adarroug Date 2006-07-05 Time 13:51 Rev Time 0.00
Received By adarroug Date 2006-07-05 Time 13:51 Sent To  
Notes
2006-07-19 00:00:00TO "COMM" BD#25
2006-07-05 00:00:00WAITING FOR "COMM" BD

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-06-02 Cont ID  
Sent By adarroug Date 2006-06-02 Time 16:36 Rev Time 0.00
Received By adarroug Date 2006-06-02 Time 16:36 Sent To  
Notes
2006-06-18 00:00:00TO COMM BOARDSPACE #61
2006-06-02 00:00:00WAITING FOR "COMM" BD

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-05-13 Cont ID  
Sent By adarroug Date 2006-05-13 Time 16:33 Rev Time 0.00
Received By rbrown Date 2006-03-23 Time 12:13 Sent To  
Notes
2006-04-13 00:00:00TO "COMM" BD#9
2006-03-23 00:00:00WAITING FOR COMM BOARD.

Review Stop P PLUMBING
Rev No 2 Status P Date 2006-09-06 Cont ID  
Sent By kstevens Date 2006-09-06 Time 17:58 Rev Time 0.00
Received By kstevens Date 2006-09-06 Time 17:58 Sent To  
Notes
2006-09-06 00:00:00MODULAR SPACE PLANS - INDICATED
 CONNECTION TO SANITARY SEWER REQUIRED,
 AND RPZV BACKFLOW REQUIRED ON WATER
 SERVICE.
2006-08-23 00:00:00NEW SHEETS

Review Stop P PLUMBING
Rev No 1 Status P Date 2006-05-13 Cont ID  
Sent By pschmitz Date 2006-05-13 Time 13:54 Rev Time 0.00
Received By pschmitz Date 2006-05-13 Time 13:54 Sent To  
Notes
2006-05-13 00:00:00PROVISO:
 BACK FLOW PREVENTER, WATER SERVICE.
 CONNECT TO SANITARY SEWER.

Review Stop Z ZONING
Rev No 4 Status F Date 2006-09-07 Cont ID  
Sent By jroach Date 2006-09-07 Time 18:14 Rev Time 0.00
Received By jroach Date 2006-09-07 Time 18:14 Sent To  
Notes
2006-09-07 00:00:009/7/2006 ***FAILED***
  
 1) THE RAMP/STAIR PLAN DOES NOT MATCH
 THE SITE PLAN, NOR THE LANDSCAPE PLAN
 WITH RESPECT TO THE FRONT AND REAR OF
 THE BUILDING.ALL PLANS NEED TO BE
 CONSISTENT.EITHER REVISE THE
 RAMP/STAIR PLAN, OR MODIFY THE SITE PLAN
 AND LANDSCAPE PLAN TO ACCOMODATE FOR THE
 NEW CONFIGURATION.
  
 2) ONLY ONE (1) COPY OF THE SITE PLAN
 WAS SUBMITTED.AT LEAST TWO (2) COPIES
 SHALL BE PROVIDED.
  
 QUESTIONS/COMMENTS, CONTACT JOHN ROACH,
 SENIOR PLANNER, AT (561) 822-1435.

Review Stop Z ZONING
Rev No 3 Status F Date 2006-07-30 Cont ID  
Sent By jroach Date 2006-07-30 Time 13:03 Rev Time 0.00
Received By jroach Date 2006-07-30 Time 13:03 Sent To  
Notes
2006-07-30 00:00:007/30/2006 ***FAILED***
  
 1) THE RAMP/STAIR PLAN DOES NOT MATCH
 THE SITE PLAN, NOR THE LANDSCAPE PLAN
 WITH RESPECT TO THE FRONT AND REAR OF
 THE BUILDING.ALL PLANS NEED TO BE
 CONSISTENT.EITHER REVISE THE
 RAMP/STAIR PLAN, OR MODIFY THE SITE PLAN
 AND LANDSCAPE PLAN TO ACCOMODATE FOR THE
 NEW CONFIGURATION.
  
 QUESTIONS/COMMENTS, CONTACT JOHN ROACH,
 SENIOR PLANNER, AT (561) 822-1435.

Review Stop Z ZONING
Rev No 2 Status F Date 2006-06-30 Cont ID  
Sent By jroach Date 2006-06-30 Time 15:53 Rev Time 0.00
Received By jroach Date 2006-06-30 Time 15:53 Sent To  
Notes
2006-06-30 00:00:006/30/06 ***FAILED***
  
 1) NO LANDSCAPE PLANS SUBMITTED.
 LANDSCAPING AND PARKING SHALL BE
 INSTALLED PRIOR TO ISSUANCE OF A CO OF
 THE SALES TRAILER.PLEASE SUBMIT
 LANDSCAPE PLANS FOR REVIEW.
  
 QUESTIONS/COMMENTS, CONTACT JOHN ROACH,
 SENIOR PLANNER, AT (561) 822-1435.

Review Stop Z ZONING
Rev No 1 Status F Date 2006-05-12 Cont ID  
Sent By jroach Date 2006-05-12 Time 19:09 Rev Time 0.00
Received By jroach Date 2006-05-12 Time 19:09 Sent To  
Notes
2006-05-12 00:00:005/12/06 ***FAILED***
  
 1) NO LANDSCAPE PLANS SUBMITTED.
 LANDSCAPING AND PARKING SHALL BE
 INSTALLED PRIOR TO ISSUANCE OF A CO OF
 THE SALES TRAILER.PLEASE SUBMIT
 LANDSCAPE PLANS FOR REVIEW.
  
 QUESTIONS/COMMENTS, CONTACT JOHN ROACH,
 SENIOR PLANNER, AT (561) 822-1435.