| Plan Review Stops For Permit 06030729 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
P |
Date |
2007-07-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-07-06 |
Time |
13:23 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2007-07-06 |
Time |
13:23 |
Sent To |
PC |
|
| Notes |
| 2007-07-06 14:13:31 | SHOP DRAWINGS: KORETECK PANELIZED BUILDING SYSTEMS | | | SENERGY SUFFACING SYSTEMS FOR THE KORETECK PANELIZED | | | WALL SYSTEM | | | ARCH ALUMINUM OUTSWING DOOR05-0829.08 | | | ROLL UP DOOR: BEST NOA 05-0606.01 | | | GRENENECK LOUVER | | | ROOF DECK FL 2635-R1 BUTLER MANUFACTURING | | | SOUTHEAST DOORS | | | FIREDOOR NOA 05-1129.07 | | | FIREDOOR NOA 03-0206.15 | | | FIREDOOR NOA 06-0512.04 | | | SHOP DRAWINGS ARCH IMPACT DOORS & STOREFRONT | | | SHOP DRAWINGS FOR RINKER RE-INFORCING STEEL | | | MSDS SHEET FOR AQUA KURE CLEAR | | | KORETECK BASE DETAIL | | | SHOP DRAWINGS FOR ELEVATOR | | | SHOP DRAWINGS FOR STEEL STAIRS | | | MEZZANINE FIBER MESH MIX DESIGN |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2007-06-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-06-14 |
Time |
16:41 |
Rev Time |
1.33 |
| Received By |
jwitmer |
Date |
2007-06-14 |
Time |
16:41 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2007-04-10 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-04-10 |
Time |
10:29 |
Rev Time |
3.33 |
| Received By |
jwitmer |
Date |
2007-04-10 |
Time |
10:29 |
Sent To |
PC |
|
| Notes |
| 2007-04-10 10:32:26 | BUILDING PLAN REVIEW | | | PERMIT: 06030729 | | | ADD: 4200 N. FLAGLER DR | | | CONT: CENTEX | | | TEL: (954)605-1010 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVISIONREVIEW | | | ACTION: DENIED | | | | | | THIS REVISION # 4 IN CREATING A TRUE SECOND STORY WILL | | | NEED THREE AREAS TO BE CORRECTED BEFORE THE REVIEW | | | PROCESS CAN BE COMPLETED. | | | 1) IN CREATINF A TRUE SECOND STORY THE BUILDING CODE | | | ANALYSIS NEEDS TO BE CORRECTED. CHANGE NUMBER 5 HAS | | | CRETED A SECOND STORY BUT THE AREA | | | INCREASES TAKEN ARE FOR A SINGLE STORY BUILDING. A 200% | | | INCREASE CAN BE TAKEN FOR MULTIPLE STORY BUILDINGS ( | | | 506.3) NOT THE 300%. THE DESIGNERS HAVEN'T SHOWN | | | ANY FRONTAGE INCEASES AAS LISTED UNDER 506.2. PLEASE | | | CORRECT, SHOW CALCULATIONS. | | | | | | 2) NUMBER TWO IS AN EITHER OR SITUATION, THE NEW | | | OFFICES OVER THE PAINT SHOP WILL REQUIRE EXITS, SHEET | | | A-2.05 INDICATES THE TWO EXITS IN A HASHED LINE GOING | | | TO THE ENCLOSED EXITS GOING TO THE OPPOSITE ENDS OF | | | THIS PORTION OF THE BUILDING. | | | 2A) SITUATION # 1- WITH THE SCENARIOLISTED ABOVE, THE | | | CODE REQUIRES TWO EXITS TABLE 1018.2 LIMITS THE TRAVEL | | | TO 75 FEET FOR A SINGLE EXIT. FOR SPRINKLERED BUILDINGS | | | THE EXIT ACCESS TRAVEL DISTANCE IS MOST RESTRICTIVE AT | | | 250' FOR AN F1 OCCUPANCY, THE DESIGN DOES COMPLY WITH | | | THIS REQUIREMENT. PLEASE INDICATE THE 36" PATH OF | | | TRAVEL ON THE PLAN. THE SITUATION THAT OCCURS WHEN THE | | | OCCUPANT LOAD OF THE NEWLY CREATED SECOND FLOOR | | | BUSINESS | | | 27 OCCUPANT LOAD/ 2 = 13.5 OR 14 OCCUPANTS PER EXIT | | | PLUS THE MEZANINE OCCUPANTS(6) WILL EQUAL 20 OCCUPANTS | | | THAT WILL CROSS THE AREA THAT IS OPEN TO BELOW IN THE | | | PARTS DEPARTMENT. THE SECTION ON THE OPENNESS OF | | | MEZZANINES 505.4(2) AT LEAST ONE DIRECT ACCESS TO AN | | | EXIT FROM THE MEZZANINE. THE AREA THAT IS OPEN TO THE | | | PARTS DEPARTMENT WOULD HAVE TO BE ENCLOSED. NEITHER THE | | | ENCLOSED MEZZANINE AREAS NEED TO BE FIRE RATED NOR THE | | | ACCESS CORRIDOR DUE TO THE FIRE SPRINKLERS. IF THIS | | | SITUATION IS DESIRED TWO ISSUES NEED TO BE CORRECTED | | | A) THE STAIRWAY THAT LEADS FROM THE BUSINESS OFFICE TO | | | THEPAINT SHOP WOULD NEED TO HAVE THE EXIT SIGN | | | REMOVED SINCE THIS EXIT LEADS INTO A MORE DANGEROUS | | | OCCUPANCY AND NOT DIRECTLY TO THE EXTERIOR. | | | B) ENCLOSE THAT PORTION OF WALL IN THE PARTS MEZZANINE | | | LEVEL. IF THIS SITATION IS DECIDED TO BE USED ON SHEET | | | E-2.3 THE EGRESS LIGHT WOULD NEED TO BE REMOVED FROM | | | THIS STAIRWAY. THE STAIRWAY NEXT TO THE CONTAINMENT BAY | | | WOULD NEED TO BE 1 HR FIRE RATED AS WELL AS THE | | | RESTROOM BELOW1019.1.5. THE OTHER ISSUE WILL BE THE | | | EXTERIOR WALL OF THIS STARWELL WHICH WOULS NOT NORMALLY | | | NEED TO BE RATED WILL NEED TO BE RATED BECAUSE OF THE | | | CLOSENESS OF THE CONTAINMENT TANK, RESTROOM EXHAUST FAN | | | INDICATES PENETRATING THIS WALL REQUIRING A FIRE | | | DAMPER. | | | | | | SITUATION # 2- IF THE PORTION OF THE MEZZANINE IN THE | | | PARTS ROOM IS TO REMAIN OPEN, THEN THE OCCUPANT LOAD | | | FROM THE BUSINESS OCCUPANCY CAN'T CROSS THIS PORTION OF | | | OPEN MEZZANIN AND THE STAIRWELL NEXT TO THE BUSINESS | | | OCCUPANCY WILL NEED TO BE 1 HR FIRE RATED, WITH A NEW | | | DOORWAY BEING CREATED SO THE EXIT DISCHARGE FROM THE | | | STAIRS WILL LEAD DIRECTLY TO THE EXTERIOR WITHOUT GOING | | | THROUGH THE PAINT SHOP A MORE DANGERIOUS OCCUPANCY. | | | GROUP. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER C. B. O. | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2006-12-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-12-20 |
Time |
14:54 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2006-12-20 |
Time |
14:54 |
Sent To |
PC |
|
| Notes |
| 2006-12-20 14:56:40 | ONT: ROONEY CENTEX CONSTRUCTION | | | TEL: (561)478-0381 | | | | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * 2004 WEST PALM BEACH AMENDMENTS | | | CHAPTER 1 OF FBC | | | | | | ACTION: BUILDING PROVISO | | | | | | -----NOTE----- | | | | | | THIS PERMIT APPLICATION IS FOR THE MTC | | | (MARINE TECHNOLOGIES CENTER) BUILDING. | | | | | | | | | 1) BUILDING PROVISO: 109.3.10* IMPACT OF CONSTRUCTION. | | | ALL | | | CONSTRUCTION ACTIVITY REGULATED BY THIS | | | CODE SHALL BE PERMORMED IN A MANNER SO | | | AS NOT TO ADVERSLY IMPACT THE CONDITION | | | OF ADJACENT PROPERTY, UNLESS SUCH | | | ACTIVITY IS PERMITTED TO AFFECT SAID | | | PROPERTY PURSUANT TO A CONSENT BY THE | | | APPLICABLE PROPERTY OWNER, UNDER TERMS & CONDITIONS | | | AGREEABLE TO THE APPLICABLE | | | PROPERTY OWNER.THIS INCLUDES BUT IS NOT | | | LIMITED TO THE CONTROL OF DUST, NOISE, | | | WATER OR DRAINAGE RUN-OFF, DEBRIS, AND | | | THE STORAGE OF CONSTRUCTION MATERIALS. | | | NEW CONSTRUCTION ACTIVITY SHALL NOT | | | ADVERSELY IMPACT HISTORICSURFACE WATER | | | DRAINAGE FLOWS SERVING ADJACENT | | | PROPERTIES, & MAY REQUIRE SPECIAL | | | DRAINAGE DESIGNCOMPLYING WITH | | | ENGINEERING STANDARDS TO PRESERVE THE | | | POSITIVE PATTERNS OF THE AFFECTED SITES.ACCORDINGLY, | | | DEVELOPERS, | | | CONTRACTORS, AND OWNERS OF ALL NEW | | | RESIDENTIAL DEVELOPMENET, INCLUDING | | | ADDITIONS, POOLS, PATIOS, DRIVEWAYS, | | | DECKS, OR SIMILAR ITEMS, ON EXISTING | | | PROPERTIES RESULTING IN A DECREASE IN | | | EXCESS OF 800SQ FT OF PERMEABLE LAND | | | AREA ON ANY PARCELL SHALL AS A PERMIT | | | CONDITION, PROVIDE A PROFESSIONALY | | | PREPARED DRAINAGE PLAN CLEARLY | | | INDICATING COMPLIANCE WITH THIS | | | PARAGRAPH. UPON COMPLETION OF THE | | | IMPROVEMENT, A CERTIFICATE FROM A | | | LICENSED ENGINEER SHALL BE SUBMITTED TO | | | THE INSPECTOR IN ORDER TO RECEIVE | | | APPROVAL OF THE FINAL INSPECTION. | | | | | | 2) BUILDING PROVISO: 109.3.10.1 HURICANE PROTECTION. IT | | | SHALL BE UNLAWFUL FOR ANY PERSON TO | | | ALLOW CONSTRUCTION RELATED MATERIALS | | | EQUIPMENET AND DEBRIS TO REMAIN LOOSE OR | | | OTHERWISE UNSECURED AT A CONSTRUCTION | | | SITE FROM 24 HRS. AFTER A HURRICANE | | | WATCH HAS BEEN ISSUED UNTIL THE | | | HURRICANE WATCH OR WARNING HAS BEEN | | | LIFTED. ALL SUCH CONSTRUCTION MATERIALS, | | | EQUIPMENT AND DEBRIS SHALL BE EITHER | | | REMOVED FROM THE CONSTRUCTION SITE OR | | | SECURED IN SUCH A MANNER AS TO MINIMIZE | | | THE DANGER OF SUCH CONSTRUCTION | | | MATERIALS, EQUIPMENT AND DEBRIS CAUSING | | | DAMAGE TO PERSONS OR PROPERTY FROM | | | HIGHWINDS. | | | ANY PERSONS WHO FAILS TO COMPLY TO | | | REMOVE OR SECURE THE CONSTRUCTION | | | MATERIALS EQUIPMENT AND DEBRIS WITHIN | | | 24 HRS AFTER A HURRICANE WATCH HAS BEEN | | | ISSUED SHALL BE SUBJECT TO A FINE NOT TO | | | EXCEED $500.00. | | | IN ADDITION TO THE ABOVE, A LICENSED | | | CONTRACTOR WHO VIOLATES THIS SECTION | | | SHALL BE SUBJECT TO DISCIPLINE PURSUANT | | | TO SECTION 113 OF THIS CHAPTER. | | | | | | 3) THISPERMIT FOR THIS PROJECT WAS FOR UNITS 3 & 4 | | | ELECTRIC GEAR BUILDING ONLY. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2006-11-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-11-13 |
Time |
11:26 |
Rev Time |
3.33 |
| Received By |
jwitmer |
Date |
2006-11-13 |
Time |
11:26 |
Sent To |
|
|
| Notes |
| 2006-11-13 14:00:40 | ADD:4300 N FLAGLER DR | | | CONT: ROONEY CENTEX CONSTRUCTION | | | TEL: (561)478-0381 | | | | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * 2004 WEST PALM BEACH AMENDMENTS | | | CHAPTER 1 OF FBC | | | | | | ACTION: BUILDING PROVISO | | | | | | -----NOTE----- | | | | | | THIS PERMIT APPLICATION IS FOR THE MTC | | | (MARINE TECHNOLOGIES CENTER) BUILDING. | | | | | | | | | 1) BUILDING PROVISO: 109.3.10* IMPACT OF CONSTRUCTION. | | | ALL | | | CONSTRUCTION ACTIVITY REGULATED BY THIS | | | CODE SHALL BE PERMORMED IN A MANNER SO | | | AS NOT TO ADVERSLY IMPACT THE CONDITION | | | OF ADJACENT PROPERTY, UNLESS SUCH | | | ACTIVITY IS PERMITTED TO AFFECT SAID | | | PROPERTY PURSUANT TO A CONSENT BY THE | | | APPLICABLE PROPERTY OWNER, UNDER TERMS & CONDITIONS | | | AGREEABLE TO THE APPLICABLE | | | PROPERTY OWNER.THIS INCLUDES BUT IS NOT | | | LIMITED TO THE CONTROL OF DUST, NOISE, | | | WATER OR DRAINAGE RUN-OFF, DEBRIS, AND | | | THE STORAGE OF CONSTRUCTION MATERIALS. | | | NEW CONSTRUCTION ACTIVITY SHALL NOT | | | ADVERSELY IMPACT HISTORICSURFACE WATER | | | DRAINAGE FLOWS SERVING ADJACENT | | | PROPERTIES, & MAY REQUIRE SPECIAL | | | DRAINAGE DESIGNCOMPLYING WITH | | | ENGINEERING STANDARDS TO PRESERVE THE | | | POSITIVE PATTERNS OF THE AFFECTED SITES.ACCORDINGLY, | | | DEVELOPERS, | | | CONTRACTORS, AND OWNERS OF ALL NEW | | | RESIDENTIAL DEVELOPMENET, INCLUDING | | | ADDITIONS, POOLS, PATIOS, DRIVEWAYS, | | | DECKS, OR SIMILAR ITEMS, ON EXISTING | | | PROPERTIES RESULTING IN A DECREASE IN | | | EXCESS OF 800SQ FT OF PERMEABLE LAND | | | AREA ON ANY PARCELL SHALL AS A PERMIT | | | CONDITION, PROVIDE A PROFESSIONALY | | | PREPARED DRAINAGE PLAN CLEARLY | | | INDICATING COMPLIANCE WITH THIS | | | PARAGRAPH. UPON COMPLETION OF THE | | | IMPROVEMENT, A CERTIFICATE FROM A | | | LICENSED ENGINEER SHALL BE SUBMITTED TO | | | THE INSPECTOR IN ORDER TO RECEIVE | | | APPROVAL OF THE FINAL INSPECTION. | | | | | | 2) BUILDING PROVISO: 109.3.10.1 HURICANE PROTECTION. IT | | | SHALL BE UNLAWFUL FOR ANY PERSON TO | | | ALLOW CONSTRUCTION RELATED MATERIALS | | | EQUIPMENET AND DEBRIS TO REMAIN LOOSE OR | | | OTHERWISE UNSECURED AT A CONSTRUCTION | | | SITE FROM 24 HRS. AFTER A HURRICANE | | | WATCH HAS BEEN ISSUED UNTIL THE | | | HURRICANE WATCH OR WARNING HAS BEEN | | | LIFTED. ALL SUCH CONSTRUCTION MATERIALS, | | | EQUIPMENT AND DEBRIS SHALL BE EITHER | | | REMOVED FROM THE CONSTRUCTION SITE OR | | | SECURED IN SUCH A MANNER AS TO MINIMIZE | | | THE DANGER OF SUCH CONSTRUCTION | | | MATERIALS, EQUIPMENT AND DEBRIS CAUSING | | | DAMAGE TO PERSONS OR PROPERTY FROM | | | HIGHWINDS. | | | ANY PERSONS WHO FAILS TO COMPLY TO | | | REMOVE OR SECURE THE CONSTRUCTION | | | MATERIALS EQUIPMENT AND DEBRIS WITHIN | | | 24 HRS AFTER A HURRICANE WATCH HAS BEEN | | | ISSUED SHALL BE SUBJECT TO A FINE NOT TO | | | EXCEED $500.00. | | | IN ADDITION TO THE ABOVE, A LICENSED | | | CONTRACTOR WHO VIOLATES THIS SECTION | | | SHALL BE SUBJECT TO DISCIPLINE PURSUANT | | | TO SECTION 113 OF THIS CHAPTER. | | | | | | 3) THISPERMIT FOR THIS PROJECT WAS FOR UNITS 3 & 4 | | | ONLY. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-09-18 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-09-18 |
Time |
12:42 |
Rev Time |
7.50 |
| Received By |
jwitmer |
Date |
2006-09-15 |
Time |
14:55 |
Sent To |
|
|
| Notes |
| 2006-09-18 00:00:00 | PERMIT: 06030729 | | | ADD:4300 N FLAGLER DR | | | CONT: ROONEY CENTEX CONSTRUCTION | | | TEL: (561)478-0381 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * 2004 WEST PALM BEACH AMENDMENTS | | | CHAPTER 1 OF FBC | | | | | | 2ND REVIEW | | | ACTION: DENIED | | | | | | -----NOTE----- | | | | | | THIS PERMIT APPLICATION IS FOR THE MTC | | | (MARINE TECHNOLOGIES CENTER) BUILDING. | | | | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 1) FL S S 713.13 | | | NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT BEFORE A | | | PERMIT WILL BE ISSUED. NOTE: 713.13(2) | | | IF THE WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS | | | NOT ACTUALLY COMMENCED | | | WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. | | | | | | 2)BUILDING PROVISO: 109.3.10* IMPACT OF CONSTRUCTION. | | | ALL | | | CONSTRUCTION ACTIVITY REGULATED BY THIS | | | CODE SHALL BE PERMORMED IN A MANNER SO | | | AS NOT TO ADVERSLY IMPACT THE CONDITION | | | OF ADJACENT PROPERTY, UNLESS SUCH | | | ACTIVITY IS PERMITTED TO AFFECT SAID | | | PROPERTY PURSUANT TO A CONSENT BY THE | | | APPLICABLE PROPERTY OWNER, UNDER TERMS & CONDITIONS | | | AGREEABLE TO THE APPLICABLE | | | PROPERTY OWNER.THIS INCLUDES BUT IS NOT | | | LIMITED TO THE CONTROL OF DUST, NOISE, | | | WATER OR DRAINAGE RUN-OFF, DEBRIS, AND | | | THE STORAGE OF CONSTRUCTION MATERIALS. | | | NEW CONSTRUCTION ACTIVITY SHALL NOT | | | ADVERSELY IMPACT HISTORICSURFACE WATER | | | DRAINAGE FLOWS SERVING ADJACENT | | | PROPERTIES, & MAY REQUIRE SPECIAL | | | DRAINAGE DESIGNCOMPLYING WITH | | | ENGINEERING STANDARDS TO PRESERVE THE | | | POSITIVE PATTERNS OF THE AFFECTED SITES.ACCORDINGLY, | | | DEVELOPERS, | | | CONTRACTORS, AND OWNERS OF ALL NEW | | | RESIDENTIAL DEVELOPMENET, INCLUDING | | | ADDITIONS, POOLS, PATIOS, DRIVEWAYS, | | | DECKS, OR SIMILAR ITEMS, ON EXISTING | | | PROPERTIES RESULTING IN A DECREASE IN | | | EXCESS OF 800SQ FT OF PERMEABLE LAND | | | AREA ON ANY PARCELL SHALL AS A PERMIT | | | CONDITION, PROVIDE A PROFESSIONALY | | | PREPARED DRAINAGE PLAN CLEARLY | | | INDICATING COMPLIANCE WITH THIS | | | PARAGRAPH. UPON COMPLETION OF THE | | | IMPROVEMENT, A CERTIFICATE FROM A | | | LICENSED ENGINEER SHALL BE SUBMITTED TO | | | THE INSPECTOR IN ORDER TO RECEIVE | | | APPROVAL OF THE FINAL INSPECTION. | | | | | | 3)BUILDING PROVISO: 109.3.10.1 HURICANE PROTECTION. IT | | | SHALL BE UNLAWFUL FOR ANY PERSON TO | | | ALLOW CONSTRUCTION RELATED MATERIALS | | | EQUIPMENET AND DEBRIS TO REMAIN LOOSE OR | | | OTHERWISE UNSECURED AT A CONSTRUCTION | | | SITE FROM 24 HRS. AFTER A HURRICANE | | | WATCH HAS BEEN ISSUED UNTIL THE | | | HURRICANE WATCH OR WARNING HAS BEEN | | | LIFTED. ALL SUCH CONSTRUCTION MATERIALS, | | | EQUIPMENT AND DEBRIS SHALL BE EITHER | | | REMOVED FROM THE CONSTRUCTION SITE OR | | | SECURED IN SUCH A MANNER AS TO MINIMIZE | | | THE DANGER OF SUCH CONSTRUCTION | | | MATERIALS, EQUIPMENT AND DEBRIS CAUSING | | | DAMAGE TO PERSONS OR PROPERTY FROM | | | HIGHWINDS. | | | ANY PERSONS WHO FAILS TO COMPLY TO | | | REMOVE OR SECURE THE CONSTRUCTION | | | MATERIALS EQUIPMENT AND DEBRIS WITHIN | | | 24 HRS AFTER A HURRICANE WATCH HAS BEEN | | | ISSUED SHALL BE SUBJECT TO A FINE NOT TO | | | EXCEED $500.00. | | | IN ADDITION TO THE ABOVE, A LICENSED | | | CONTRACTOR WHO VIOLATES THIS SECTION | | | SHALL BE SUBJECT TO DISCIPLINE PURSUANT | | | TO SECTION 113 OF THIS CHAPTER. | | | | | | 4) COMPLIED. | | | | | | 5) COMPLIED. | | | | | | 6) PLANSCOMPLIED WITH THE DEFINITION | | | OF MEZZANINE THERE ARE OTHER CODE ISSUE | | | THAT WILL NEED TO BE ADDRESSED: | | | 6A) PLEASE PROVIDE INFORMATION HOW | | | VERTICAL ACCESSIBILITY WILL BE | | | ADDRESSED. PROVIDE DOCUMENTATION. | | | | | | 6B)2ND REQUEST, PLEASE SEE 110.4.2 | | | STORAGE & FACTORY- INDUSTRIAL | | | OCCUPANCIES. IT SHALL BE THE | | | RESPONSIBILITY OF THE OWNER, AGENT, | | | PROPIETOR OR OCCUPANT OF GROUP S AND | | | GROUP F OCCUPANCIES, OR ANY OCCUPANCY | | | WHERE EXCESSIVE FLOOR LOADING IS LIKELY | | | TO OCCUR, TO EMPLOY A COMPETENT ARCHI- | | | TECT OR ENGINEER IN COMPUTING THE SAFE | | | FLOOR LOAD CAPACITY. ALL SUCH COMPUTA- | | | TIONS SHALL BE ACCOMPANIED BY AN AFFA- | | | DAVIT FROM THE ARCHITECT OR ENGINEER | | | STATING THE SAFE ALLOWABLE FLOOR LOADS | | | ON EACH FLOOR IN POUNDS PER SQ FT.THE | | | COMPUTATIONS & AFFADAVIT SHALL BE FILED | | | AS A PERMANENT RECORD OF THE BLDG DEPT. | | | RESPONCE: PLEAASE SEE AFFIDAVIT AND | | | COMPUTATIONS FOR SAFE ALLOWABLE FLOOR | | | LOAD CAPACITY. (BUTLER TO PROVIDE) | | | | | | NO AFFADAVIT OR CALCULATIONS WERE | | | SUBMITTED. CUT SECTION DO6-137731-02B | | | DOES INDICATE MEZZANINE LEVEL BUT NO | | | FLOOR LOADS. I ALSO CHECKED COLUMNS FOR | | | POINT LOADING. | | | | | | 6C) 2ND REQUEST, 10.4.3.SIGNS REQUIRED. | | | IN EVERY | | | BUILDING OR PART OF A BUILDING USED FOR | | | STORAGE, INDUSTRIAL OR HAZARDOUS PUR- | | | POSES, THE SAFE FLOOR LOADS, AS REVIEWED | | | BY THE BUILDING OFFICIAL ON THE PLAN, | | | SHALL BE MARKED ON PLATES OF APPROVED DE | | | SIGN WHICH SHALL BE SUPPLIED & SECURELY | | | AFFIXED BY THE OWNER OF THE BUILDING IN | | | A CONSPICUOUS PLACE IN EACH STORY TO | | | WHICH THEY RELATE. SUCH PLATES SHALL NOT | | | BE REMOVEDOR DEFACED, & IF LOST, | | | REMOVED THE OWNER OF THE BUILDING SHALL | | | REPLACE THEM. | | | | | | THE SIGNAGE HAS TO CORRALATE WITH THE | | | DESIGN FLOOR LOAD FOR THE MEZZANINE: | | | 125 LBS/ SQ FT LIGHT | | | 250 LBS/ SQ FT HEAVY | | | | | | 7) 2ND REQUEST, THE SECOND FLOOR OFFICE | | | AREA HOW MANY | | | PEOPLE WILL OCCUPY THIS AREA? WILL THERE | | | BE ANY STORAGE AREAS ON THE SECOND | | | FLOOR? POSSIBLE VERTICAL ACCESSABILITY. | | | PROVIDE DETAILS HOW VERTICAL | | | ACCESSBILITY WILL BE MET. | | | | | | 8) COMPLIED. | | | | | | 9) 2ND REQUEST, ) PROVIDE INFORMATION | | | WHY THERE IS A CONTAINMENT AREA, BAY# 8? | | | THE RESPONSE IS : PLEASE SEE ATTACHED | | | LETTER OF THE PURPOSE OF THE CONTAINMENT RYBOVICH). | | | THERE IS NO LETTER OR OTHER DOCUMENTATION ATTACHED TO | | | THESE REVIEW | | | COMMENTS! | | | | | | 10) COMPLIED. | | | | | | 11) COMPLIED. | | | | | | 12) COMPLIED. | | | | | | 13) COMPLIED THROUGH FOUNDATION PERMIT | | | ELEVATION CERTIFICATE. | | | | | | 14) COMPLIED. | | | | | | 15) COMPLIED. | | | | | | 16) COMPLIED. | | | | | | 17) BUTLER LAYOUT SHEETS 2 OF THE 3 | | | SEEETS HAVE RAISED SEALS THE OTHER IS | | | MISSING THE RAISED SEAL. FAC | | | 61G15-23.002 (FROM FOUNDATION SET, NO | | | PLANS FOUND IN THE BLDG SET). | | | MISSING THE BUTLER LAYOUT SHEETS ALL | | | TOGETHER. | | | | | | 18) COMPLIED. | | | | | | 19) COMPLIED. | | | | | | 20) COMPLIED. | | | | | | 21) 2ND REQUEST, W P B ADMINISTRTIVE | | | CODE 106.3.3* PRODUCT APPROVALS. THOSE | | | PRODUCTS WHICH ARE REGULATED BY DCA RULE | | | 9B-72 SHALL BE REVIEWED AND APPROVED IN | | | WRITING BY THE DESIGNER OF RECORD PRIOR | | | TO SUBMITTAL FOR JURISDICTIONAL | | | APPROVAL. | | | | | | 22) COMPLIED. | | | | | | 23) COMPLIED. | | | | | | 24) 2ND REQUEST,THE PERMIT APPLICATION | | | STATES DESCRIPTION OF WORK TO BE A 1 | | | STORY MTC PRE-ENGINEERED BUILDING. NO | | | OTHER IMPROVEMENTS ARE MENTIONED UNDER | | | THE PREMIT APPLICATION DESRIPTION OF | | | WORK. THE PLANS SUBMITTED HAVE AN | | | ELECTRICAL GEAR BUILDING WITH ARCH M-E-P | | | AND STRUCTURAL PLANS INCLUDED. NOT TO BE | | | PART OF THIS PERMIT, NOR IS SITE | | | IMPROVEMETNS. | | | | | | THE RESPONSE INDICATES , YES THE | | | ELECTRICAL GEAR ROOM IS TO BE PART OF | | | THIS PERMIT APPLICATION, PLEASE ADD TO | | | THE PROJECT DESCRIPTION. | | | | | | THE PERMIT APPLICATION NOT SUBMITTED. | | | | | | | | | 25) 2ND REQUEST, A-6.01 INDICATES A | | | DETAIL 2/A-6.02 WHICH INDICATES USE OF | | | FOAM TRIM. 1406.2.2 ARCHITECTURAL TRIM. ARCHITECTURAL | | | TRIM THAT EXCEEDS 40 FEET | | | (12 192 MM) IN HEIGHT ABOVE GRADE PLANE | | | SHALL BE CONSTRUCTED OF APPROVED | | | NONCOMBUSTIBLE MATERIALS AND SHALL BE | | | SECURED TO THE WALL WITH METAL OR OTHER | | | APPROVED NONCOMBUSTIBLE BRACKETS. | | | | | | IF YOU DO NOT AGREE WITH THE BUILDING | | | OFFICIALS DECISION AND OR INTERPRETATION | | | OF THE CODE YOU MAY APPLY FOR AN | | | APPEAL TO THE CONSTRUCTION BOARD OF | | | ADJUSTMENT & APPEAL, OR YOU MAY APPLY | | | FOR A VARIANCE TO THE TECHNICAL CODES. | | | ACOPY OF THE FORM IS ATTACHED. | | | | | | 26) 2ND REQUEST,BEFORE A PERMIT TO | | | CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-05-18 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-05-18 |
Time |
07:46 |
Rev Time |
10.00 |
| Received By |
jwitmer |
Date |
2006-05-17 |
Time |
07:08 |
Sent To |
|
|
| Notes |
| 2006-05-18 00:00:00 | PERMIT: 06030729 | | | ADD:4300 N FLAGLER DR | | | CONT: ROONEY CENTEX CONSTRUCTION | | | TEL: (561)478-0381 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * 2004 WEST PALM BEACH AMENDMENTS | | | CHAPTER 1 OF FBC | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | -----NOTE----- | | | | | | THIS PERMIT APPLICATION IS FOR SITE | | | CLEARING AND SITE UTILITIES AND | | | FOUNDATION OF THE MTC (MARINE | | | TECHNOLOGIES CENTER) BUILDING. | | | | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 1) FL S S 713.13 | | | NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT BEFORE A | | | PERMIT WILL BE ISSUED. NOTE: 713.13(2) | | | IF THE WORK DESCRIBED IN THE NOTICE OF | | | COMMENCEMENT IS NOT ACTUALLY COMMENCED | | | WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. | | | | | | 2) 109.3.10* IMPACT OF CONSTRUCTION. ALL | | | CONSTRUCTION ACTIVITY REGULATED BY THIS | | | CODE SHALL BE PERMORMED IN A MANNER SO | | | AS NOT TO ADVERSLY IMPACT THE CONDITION | | | OF ADJACENT PROPERTY, UNLESS SUCH | | | ACTIVITY IS PERMITTED TO AFFECT SAID | | | PROPERTY PURSUANT TO A CONSENT BY THE | | | APPLICABLE PROPERTY OWNER, UNDER TERMS & | | | CONDITIONS AGREEABLE TO THE APPLICABLE | | | PROPERTY OWNER.THIS INCLUDES BUT IS NOT | | | LIMITED TO THE CONTROL OF DUST, NOISE, | | | WATER OR DRAINAGE RUN-OFF, DEBRIS, AND | | | THE STORAGE OF CONSTRUCTION MATERIALS. | | | NEW CONSTRUCTION ACTIVITY SHALL NOT | | | ADVERSELY IMPACT HISTORICSURFACE WATER | | | DRAINAGE FLOWS SERVING ADJACENT | | | PROPERTIES, & MAY REQUIRE SPECIAL | | | DRAINAGE DESIGNCOMPLYING WITH | | | ENGINEERING STANDARDS TO PRESERVE THE | | | POSITIVE PATTERNS OF THE AFFECTED | | | SITES.ACCORDINGLY, DEVELOPERS, | | | CONTRACTORS, AND OWNERS OF ALL NEW | | | RESIDENTIAL DEVELOPMENET, INCLUDING | | | ADDITIONS, POOLS, PATIOS, DRIVEWAYS, | | | DECKS, OR SIMILAR ITEMS, ON EXISTING | | | PROPERTIES RESULTING IN A DECREASE IN | | | EXCESS OF 800SQ FT OF PERMEABLE LAND | | | AREA ON ANY PARCELL SHALL AS A PERMIT | | | CONDITION, PROVIDE A PROFESSIONALY | | | PREPARED DRAINAGE PLAN CLEARLY | | | INDICATING COMPLIANCE WITH THIS | | | PARAGRAPH. UPON COMPLETION OF THE | | | IMPROVEMENT, A CERTIFICATE FROM A | | | LICENSED ENGINEER SHALL BE SUBMITTED TO | | | THE INSPECTOR IN ORDER TO RECEIVE | | | APPROVAL OF THE FINAL INSPECTION. | | | | | | 3) 109.3.10.1 HURICANE PROTECTION. | | | IT SHALL BE UNLAWFUL FOR ANY PERSON TO | | | ALLOW CONSTRUCTION RELATED MATERIALS | | | EQUIPMENET AND DEBRIS TO REMAIN LOOSE OR | | | OTHERWISE UNSECURED AT A CONSTRUCTION | | | SITE FROM 24 HRS. AFTER A HURRICANE | | | WATCH HAS BEEN ISSUED UNTIL THE | | | HURRICANE WATCH OR WARNING HAS BEEN | | | LIFTED. ALL SUCH CONSTRUCTION MATERIALS, | | | EQUIPMENT AND DEBRIS SHALL BE EITHER | | | REMOVED FROM THE CONSTRUCTION SITE OR | | | SECURED IN SUCH A MANNER AS TO MINIMIZE | | | THE DANGER OF SUCH CONSTRUCTION | | | MATERIALS, EQUIPMENT AND DEBRIS CAUSING | | | DAMAGE TO PERSONS OR PROPERTY FROM | | | HIGHWINDS. | | | ANY PERSONS WHO FAILS TO COMPLY TO | | | REMOVE OR SECURE THE CONSTRUCTION | | | MATERIALS EQUIPMENT AND DEBRIS WITHIN | | | 24 HRS AFTER A HURRICANE WATCH HAS BEEN | | | ISSUED SHALL BE SUBJECT TO A FINE NOT TO | | | EXCEED $500.00. | | | IN ADDITION TO THE ABOVE, A LICENSED | | | CONTRACTOR WHO VIOLATES THIS SECTION | | | SHALL BE SUBJECT TO DISCIPLINE PURSUANT | | | TO SECTION 113 OF THIS CHAPTER. | | | | | | 4) A-2.04 BAY# 19 PLEASE PROVIDE | | | ADDITIONAL INFORMATION AS TO WHAT TYPE | | | OF MATERIALS ARE TO BE STORED, WHAT TYPE | | | | | | OF RACKS, AND HEIGHT OF RACKS. S1 VS S2 | | | OCCUPANCY, SECTION 311.1. | | | | | | 5) NOTE FOR BAYS 2,14,15 & 16 WITH OPEN | | | MEZZANINES. THE AREA BELOW THE | | | MEZZANINES CAN NOT BE FILED IN AFTER | | | C.O. WILL MAKE A CODE VIOLATION.THIS | | | WILL BE A STIPULATION FOR ALL MEZZANINES | | | IN THIS BUILDING. | | | 505.2 AREA LIMITATION. | | | THE AGGREGATE AREA OF A MEZZANINE OR | | | MEZZANINES WITHIN A ROOM SHALL NOT | | | EXCEED ONE-THIRD OF THE AREA OF THAT | | | ROOM OR SPACE IN WHICH THEY ARE LOCATED. | | | THE ENCLOSED PORTIONS OF ROOMS SHALL NOT | | | BE INCLUDED IN A DETERMINATION OF THE | | | SIZE OF THE ROOM IN WHICH THE MEZZANINE | | | IS LOCATED. IN DETERMINING THE ALLOWABLE | | | MEZZANINE AREA, THE AREA OF THE | | | MEZZANINE SHALL NOT BE INCLUDED IN THE | | | AREA OF THE ROOM. | | | | | | 6A) A-2.04 / A2.05 OFFICE BAY # 1. | | | DEFINITION: MEZZANINE. AN INTERMEDIATE | | | LEVEL OR LEVELS BETWEEN THE FLOOR AND | | | CEILING OF ANY STORY WITH AN AGGREGATE | | | FLOOR AREA OF NOT MORE THAN ONE-THIRD OF | | | THE AREA OF THE ROOM OR SPACE IN WHICH | | | THE LEVEL OR LEVELS ARE LOCATED (SEE | | | SECTION 505 ). | | | 505.2 AREA LIMITATION. | | | THE AGGREGATE AREA OF A MEZZANINE OR | | | MEZZANINES WITHIN A ROOM SHALL NOT | | | EXCEED ONE-THIRD OF THE AREA OF THAT | | | ROOM OR SPACE IN WHICH THEY ARE LOCATED. | | | THE ENCLOSED PORTIONS OF ROOMS SHALL NOT | | | BE INCLUDED IN A DETERMINATION OF THE | | | SIZE OF THE ROOM IN WHICH THE MEZZANINE | | | IS LOCATED. IN DETERMINING THE ALLOWABLE | | | MEZZANINE AREA, THE AREA OF THE | | | MEZZANINE SHALL NOT BE INCLUDED IN THE | | | AREA OF THE ROOM. | | | IN THE OFFICE BAY THERE ISN'T A | | | MEZZANINE BUT A TRUE SECOND STORY. THE | | | DEFINITION AND AREA LIMITATION | | | INDICATES THAT THE MEZZANINE MUST | | | COMMUNICATE WITHIN THE ROOM IT IS IN. | | | THIS CONFIGURATION IS TRUELY A SECOND | | | STORY AND MUST MEET THE EGRESS | | | REQUIREMENTS OF VERTICAL EXIT | | | ENCLOSURERS, SECTION 1019. | | | | | | 6B)110.4.2 STORAGE & FACTORY- INDUS- | | | TRIAL OCCUPANCIES. IT SHALL BE THE | | | RESPONSIBILITY OF THE OWNER, AGENT, | | | PROPIETOR OR OCCUPANT OF GROUP S AND | | | GROUP F OCCUPANCIES, OR ANY OCCUPANCY | | | WHERE EXCESSIVE FLOOR LOADING IS LIKELY | | | TO OCCUR, TO EMPLOY A COMPETENT ARCHI- | | | TECT OR ENGINEER IN COMPUTING THE SAFE | | | FLOOR LOAD CAPACITY. ALL SUCH COMPUTA- | | | TIONS SHALL BE ACCOMPANIED BY AN AFFA- | | | DAVIT FROM THE ARCHITECT OR ENGINEER | | | STATING THE SAFE ALLOWABLE FLOOR LOADS | | | ON EACH FLOOR IN POUNDS PER SQ FT.THE | | | COMPUTATIONS & AFFADAVIT SHALL BE FILED | | | AS A PERMANENT RECORD OF THE BLDG DEPT. | | | | | | 6C) 10.4.3.SIGNS REQUIRED. IN EVERY | | | BUILDING OR PART OF A BUILDING USED FOR | | | STORAGE, INDUSTRIAL OR HAZARDOUS PUR- | | | POSES, THE SAFE FLOOR LOADS, AS REVIEWED | | | BY THE BUILDING OFFICIAL ON THE PLAN, | | | SHALL BE MARKED ON PLATES OF APPROVED DE | | | SIGN WHICH SHALL BE SUPPLIED & SECURELY | | | AFFIXED BY THE OWNER OF THE BUILDING IN | | | A CONSPICUOUS PLACE IN EACH STORY TO | | | WHICH THEY RELATE. SUCH PLATES SHALL NOT | | | BE REMOVEDOR DEFACED, & IF LOST, | | | REMOVED THE OWNER OF THE BUILDING SHALL | | | REPLACE THEM. | | | | | | 7) THE SECOND FLOOR OFFICE AREA HOW MANY | | | PEOPLE WILL OCCUPY THIS AREA? WILL THERE | | | BE ANY STORAGE AREAS ON THE SECOND | | | FLOOR? POSSIBLE VERTICAL ACCESSABILITY. | | | | | | 8) ADDITIONAL INFORMATION REQUIRED. | | | PLEASE DESCRIBE THE USAGE OF THE PARTS | | | DEPOT ROOM. | | | | | | 9) PROVIDE INFORMATION WHY THERE IS A | | | CONTAINMENT AREA, BAY# 8? | | | | | | 10) FP2.2 DOESN'T INDICATE THE STORAGE | | | ROOM# 19, NO OTHER SHEETS. | | | | | | 11) S-1 INDICATES THERE IS A SOILS | | | REPORT PLEASE PROVIDE.1802.2.1 | | | QUESTIONABLE SOIL. | | | WHERE THE SAFE-SUSTAINING POWER OF THE | | | SOIL IS IN DOUBT, OR WHERE A | | | LOAD-BEARING VALUE SUPERIOR TO THAT | | | SPECIFIED IN THIS CODE IS CLAIMED, THE | | | BUILDING OFFICIAL SHALL REQUIRE THAT THE | | | NECESSARY INVESTIGATION BE MADE. SUCH | | | INVESTIGATION SHALL COMPLY WITH THE | | | PROVISIONS OF SECTIONS 1802.4 THROUGH | | | 1802.6 . | | | | | | 12) S-1 NOTE FOR PRE-ENGINEERED BUILDING | | | INDICATES THE FBC 2001 CODE EDITION, | | | PLEASE CORRECT. | | | | | | 13) PROVIDE FLOOD ZONE ELEVATION | | | CERTIFICATE FOR NEW CONSTRUTION WITH | | | BASE FLOOD ELEVATION, CITY CODE REQUIRES | | | AN ADDITIONAL 6". | | | | | | 14) S1-S2 MISSING INFORMATION, ANCHOR | | | BOLT DESCRIPTION, SIZE LENGTH AND GRADE | | | OF STEEL.BUTLERNOTE " FOUNDATION | | | DESIGN AND ANCHOR BOLTS, NUTS AND | | | WASHERS ARE NOT FURNISHED BY BUTLER. | | | PROPER EMBEDMENT LENGTH MUST BE DESIGNED | | | BY THE FOUNDATION DESIGN ENGINEER. | | | | | | 15)****CAUTION**** | | | BUTLER NOTE:(FROM FOUNDATION PERMIT, | | | PLANS NOT FOUND IN BLDG PERMIT SET!) | | | RIGID FRAMES HAVE BOTH HORIZONTAL AND | | | VERTICAL REACTIONS ACTING AT THE BASE OF | | | THE COLUMN. IN SOME CASES THE HORIZONTAL | | | FORCE IS GREATER THAN THE VERTICAL. A | | | FOUNDATION DESIGNED FOR A CONVENTIONAL | | | STRUCTURE WILL NOT BE SATISFACTORY. | | | FAILURE TO MAKE ADEQUATE PROVISION FOR | | | THE HORIZONTAL THRUST CAN RESULT IN | | | FOUNDATION FAILURE. | | | PLEASE PROVIDE RESPONCE. | | | | | | 16) BUTLER LAYOUT PLANS HAVE COPIED | | | ENGINEERS SIGNATURES:(FROM FOUNDATION | | | PLAN, PLANS NOT FOUND IN BLDG SET FOR | | | SHELL OR MEZZANINE LEVEL) | | | PLANS, SPECIFICATIONS,REPORTS OR | | | OTHER DOCUMENTS PREPARED BY THE DESIGN | | | PROFESSIONAL AND BEING FILED FOR PUBLIC | | | RECORD SHALL HAVE THE SIGNATURE AND | | | SEAL OF THE DESIGN PROFESSIONAL AFFIXED | | | TO THE DOCUMENT. | | | FL STATE STAT: 61G15-23.002 ENGINEERS | | | FL ATATE STAT: 61G16.003 ARCHITECTS | | | | | | 17) BUTLER LAYOUT SHEETS 2 OF THE 3 SETS | | | HAVE RAISED SEALS THE OTHER IS MISSING | | | THE RAISED SEAL. FAC 61G15-23.002 | | | (FROM FOUNDATION SET, NO PLANS GOUND IN | | | BLDG SET) | | | | | | 18) LETTERFROM BUTLER MANUFACTURING CO | | | PATRICK A. KREUSER P.E. ALSO REQUIRES | | | SIGNATURE TO BE SEALED. | | | PLANS, SPECIFICATIONS,REPORTS OR | | | OTHER DOCUMENTS PREPARED BY THE DESIGN | | | PROFESSIONAL AND BEING FILED FOR PUBLIC | | | RECORD SHALL HAVE THE SIGNATURE AND | | | SEAL OF THE DESIGN PROFESSIONAL AFFIXED | | | TO THE DOCUMENT. | | | FL STATE STAT: 61G15-23.002 ENGINEERS | | | FL ATATE STAT: 61G16.003 ARCHITECTS | | | (FROM FOUNDATION SET, NOT FOUND IN BLDG | | | SET) | | | | | | 19) GROUND FLOOR ENGINEERING:MISSING, | | | FAC 471.023 F.S.CERTIFICATE OF | | | AUTHORIZATION.THE TITLE BLOCK FOR ANY | | | SHEET BEARING THE NAME OF AN ENGINEER | | | PRACTICING UNDER A FICTITIOUS NAME, A | | | CORPORATION, OR A PARTNERSHIP, OFFERING | | | ENGINEERING SERVICES, SHALL INCLUDE THE | | | CERTIFICATE OF AUTHORIZATION NUMBER. | | | ADD THE NUMBER TO EACH SHEET.THIS MAY | | | BE ADDED BY HAND. | | | | | | 20) 1609.1.4 PROTECTION OF OPENINGS. | | | IN WIND-BORNE DEBRIS REGIONS, EXTERIOR | | | GLAZING THAT RECEIVES POSITIVE PRESSURE | | | IN THE LOWER 60 FEET (18.3 M) IN | | | BUILDINGS SHALL BE ASSUMED TO BE | | | OPENINGS AND THE BALANCE OF GLAZED | | | OPENINGS IN THE REST OF THE BUILDING | | | SHALL BE ASSUMED TO BE ZERO UNLESS SUCH | | | GLAZING THAT RECEIVES POSITIVE PRESSURE | | | IS IMPACT RESISTANT OR PROTECTED WITH AN | | | IMPACT RESISTANT COVERING MEETING THE | | | REQUIREMENTS OF SSTD 12, ASTM E 1886 AND | | | ASTM E 1996, OR MIAMI-DADE TAS 201, 202 | | | AND 203 REFERENCED THEREIN AS FOLLOWS: | | | 1.GLAZED OPENINGS LOCATED WITHIN 30 | | | FEET (9.1 M) OF GRADE SHALL MEET THE | | | REQUIREMENTS OF THE LARGE MISSILE TEST. | | | 2.GLAZED OPENINGS LOCATED MORE THAN | | | 30 FEET (9.1 M) ABOVE GRADE SHALL MEET | | | THE PROVISIONS OF THE SMALL MISSILE | | | TEST. | | | | | | 21) WPB ADMIN CODE 106.3* PRODUCT | | | APPROVALS. THOSE PRODUCT WHICH ARE | | | REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL | | | FOR JURISDICTIONAL APPROVAL. | | | | | | 22) PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 23)FL BLD CODE 1609.1.5: COMPONENTS & | | | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- | | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | | TESTING REPORTS,MISSING REPORTS ARE AS | | | FOLLOWS: | | | A) WINDOWS | | | B) SWING DOORS | | | C) OVERHEAD DOORS | | | D) PANEL WALLS | | | E) ROOFING ASSEMBLIES | | | F) LOUVERS | | | | | | 24) THE PERMIT APPLICATION STATES | | | DESCRIPTION OF WORK TO BE A 1 STORY MTC | | | PRE-ENGINEERED BUILDING. NO OTHER | | | IMPROVEMENTS ARE MENTIONED UNDER THE | | | PREMIT APPLICATION DESRIPTION OF WORK. | | | THE PLANS SUBMITTED HAVE AN ELECTRICAL | | | GEAR BUILDING WITH ARCH M-E-P AND | | | STRUCTURAL PLANS INCLUDED. NOT TO BE | | | PART OF THIS PERMIT, NOR IS SITE | | | IMPROVEMETNS. | | | | | | 25) A-6.01 INDICATES A DETAIL 2/A-6.02 | | | WHICH INDICATES USE OF FOAM TRIM. | | | 1406.2.2 ARCHITECTURAL TRIM. | | | ARCHITECTURAL TRIM THAT EXCEEDS 40 FEET | | | (12 192 MM) IN HEIGHT ABOVE GRADE PLANE | | | SHALL BE CONSTRUCTED OF APPROVED | | | NONCOMBUSTIBLE MATERIALS AND SHALL BE | | | SECURED TO THE WALL WITH METAL OR OTHER | | | APPROVED NONCOMBUSTIBLE BRACKETS | | | | | | 26)BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
10 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-08-08 |
Time |
12:07 |
Sent To |
|
|
| Notes |
| 2007-08-08 12:07:53 | | | | | | | ELECTRICAL SUBMITTALS OK./WRT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
9 |
Status |
P |
Date |
2007-07-24 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-07-12 |
Time |
16:08 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-07-12 |
Time |
12:09 |
Sent To |
PC |
|
| Notes |
| 2007-07-12 12:10:12 | | | | | | | REVISED ELECTRICAL ROOM EQUIPMENT LAYOUT./WRT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
8 |
Status |
P |
Date |
2007-07-12 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-07-12 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-07-12 |
Time |
08:38 |
Sent To |
|
|
| Notes |
| 2007-07-12 11:43:36 | | | | | | | PROVISO | | | | | | COMMENT FROM PREVIOUS REVIEW NOT ADDRESSED: | | | | | | 4} INDICATE COMPLIANCE WITH CHAPTER 13 FBC. PLACE ALL | | | RELATED EQUIPMENT ON THE PLAN, PROVIDE A LEGENDFOR | | | SAME. SUBMIT NEW ENERGY CALCULATIONS CORRELATING WITH | | | ALL FIXTURE TYPES INDICATED ON THE DRAWINGS. | | | | | | THE REASON FOR THIS COMMENT WAS THE CHANGES FROM | | | MEZANINE TO OFFICE AREAS ON THE SECOND FLOOR. | | | LUMINAIRES HAVE BEEN ADDED AND CHANGED TYPES THROUGHOUT | | | MUCH OF THE PROJECT. THE CALCULATIONS FOR THE SHELL | | | BUILDING THAT WERE SUBMITTED FOR PERMITTING NEED TO BE | | | AMENDED PER 13-103.3 ATTACHED. | | | | | | 13-103.3 BUILDING PERMITS. | | | PRIOR TO RECEIVING THE PERMIT TO BEGIN CONSTRUCTION OR | | | RENOVATION, OWNERS, OR AN AGENT DULY DESIGNATED BY THE | | | OWNER, OF ALL BUILDINGS SHALL CERTIFY ENERGY CODE | | | COMPLIANCE TO THE DESIGNATED LOCAL ENFORCEMENT AGENCY. | | | IF, DURING THE BUILDING CONSTRUCTION OR RENOVATION, | | | ALTERATIONS ARE MADE IN THE DESIGN, MATERIALS, OR | | | EQUIPMENT WHICH WOULD DIMINISH THE ENERGY PERFORMANCE | | | OF THE BUILDING, AN AMENDED COPY OF THE COMPLIANCE | | | CERTIFICATIONS SHALL BE SUBMITTED TO THE LOCAL | | | ENFORCEMENT AGENCY ON OR BEFORE THE DATE OF FINAL | | | INSPECTION BY THE BUILDING OWNER OR HIS OR HER AGENT. | | | BUILDING OFFICIALS OR THEIR OFFICIALLY DESIGNATED | | | REPRESENTATIVES SHALL ASSURE THAT THE COMPLIANCE FORMS | | | ARE COMPLETE AND WITHOUT GROSS ERRORS. | | | | | | PLEASE SUBMIT THE COMPLIANCE CERTIFICATION ONLY AS THE | | | REVIEWED PLANS WITH FIXTURE SCHEDULES ARE ON FILE. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
F |
Date |
2007-05-10 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-05-10 |
Time |
10:12 |
Rev Time |
6.00 |
| Received By |
btrobaug |
Date |
2007-05-08 |
Time |
07:04 |
Sent To |
|
|
| Notes |
| 2007-05-09 16:58:20 | | | | | | | REVISION DENIED | | | | | | 1} THE VALUE ON THE APPLICATION MUST INCLUDE THE TOTAL | | | COST OF LABOR AND MATERIAL.THE ADDITION OF THE | | | ELEVATOR, MDP-3 SERVICE ANDRELATED EQUIPMENT, 2000 | | | AMP QUICK DISCONNECT SWITCHBOARD, THE FEEDER AND BRANCH | | | CIRCUITING FOR EQUIPMENT IN THE CARPENTER SHOP, METAL | | | SHOP, PAINT SHOP, SANDING AREA ETC. THAT ARE ADDED IN | | | THIS REVISION REQUIRE THE VALUE TO BE INCREASED. ADJUST | | | THE VALUE AT THE PERMIT CLERKS DESK, AND PAY THE | | | DIFFERENCE IN FEES PRIOR TO RESUBMITTING. | | | | | | 2}IDENTIFICATION IS REQUIRED AT MDP-3, AS IS SHOWN AT | | | MSB-5 PER 230.2(E). PLEASE ADD TO THE PLAN. SHEET | | | E3.2. | | | | | | 3} MDP-1, MDP-2 AND MSB5 REQUIRE GROUND FAULT | | | PROTECTION PER 230.95 AND 240.13. PLEASE INDICATE ON | | | PLANS AT THE PANEL SCHEDULES. | | | | | | 4} INDICATE COMPLIANCE WITH CHAPTER 13 FBC. PLACE ALL | | | RELATED EQUIPMENT ON THE PLAN, PROVIDE A LEGENDFOR | | | SAME. SUBMIT NEW ENERGY CALCULATIONS CORRELATING WITH | | | ALL FIXTURE TYPES INDICATED ON THE DRAWINGS. | | | | | | 5} PLEASE SEE CIRCUITS LABLED P5-4, P5-17,19, P5- 21,23 | | | ANDP5-32 ARE MISMARKED. (THOSE CIRCUITS ARE LISTED IN | | | PANEL B5). | | | | | | 6} PLEASE INDICATE THE DUTY-CYCLE SERVICE OF THE 25 HP | | | ELEVATOR MOTOR. VERIFY THAT THERE IS A 400 AMP FUSED | | | DISCONNECT ON THE LOAD SIDE OF A 225 AMP DISCONNECT. | | | SHEET E4.5, MSB5 RISER. | | | | | | 7} PANEL HB4 FEEDER IS 250 AMPS PER THE FEEDER | | | SCHEDULE, LISTED AS 225 AMP ON THE RISER (SHEET E4.5), | | | AND LISTED AS 400 AMPS ON THE PANEL SCHEDULE SHEET | | | E4.7. CORRELATE SAME. | | | | | | 8} PLEASE VERIFY OR REMOVE THE NOTE UNDER MSB5, SHEET | | | E4.1, REGARDING THE 6' WIDTH. | | | | | | 9} PLEASE INDICATE THEDESIGNERS INTENDED | | | CLASSIFICATION OF THE CARPENTER SHOP. NOT KNOWINGTHE | | | TYPE OF DUST COLLECTION SYSTEM TO BE INSTALLED, THE | | | REVIEWER CANNOT DETERMINE THAT CLASSIFICATION AT THIS | | | TIME.PER 500.5. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
F |
Date |
2007-03-28 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-03-28 |
Time |
12:22 |
Rev Time |
2.00 |
| Received By |
btrobaug |
Date |
2007-03-28 |
Time |
09:53 |
Sent To |
|
|
| Notes |
| 2007-03-28 12:22:37 | | | | | | | DENIED/CONFLICTING INFORMATION | | | | | | PLEASE MAKE THE FOLLOWING CHANGES ON THE PLANS FOR | | | CLARITY. | | | | | | 1} E.2.1 THE SHEET SUBMITTED FOR REVISION DOES NOT THE | | | CONTAIN THE SAME FLOOR PLANS AS THE SHEET IN THE PERMIT | | | SET IT IS INTENDED TO REPLACE.ALSO PLEASE NOTE | | | "REVISION #3 DATED 9/1/06 AND THE DELTA NUMBERED THE | | | SAME IN THE BLOCK WITH THE SHEET NUMBER, IS A DATE | | | PRIOR TO THE PERMIT SET DATE. SINCE ALL SHEETS | | | SUBMITTED DO NOT MATCH THE PERMIT SET, POSSIBLY THE | | | WRONG SET WAS SUBMITTED. | | | | | | 2} E2.2, NOT THE SAME FLOOR PLANS AS PERMIT SET. ALSO | | | THE "COVERED WORKSHED" AND STORAGE SHED HAVE BEEN | | | REMOVED WITH OUT CLOUDING OR OTHER INDICATION THEY WERE | | | INTENTIONALLY REMOVED. | | | | | | 3} E2.3, THIS SHEET CONTAINS NO POWER OR SYSTEMS PLAN | | | AS THE SHEET IT IS INTENDED TO REPLACE DOES. | | | | | | 4} E2.4, THE REVISION IS SHOWING 2ND FLOOR LIGHTING, | | | THE PERMIT SET IS 1ST FLOOR PLANS. | | | | | | 5} E3.1 OF THE PERMIT SET IS THE RISER AND FEEDER | | | SCHEDULES AND CANNOT BE REVISED WITH A FLOOR PLAN | | | DRAWING. ALSO THE REVISED SHEET SHOWS A "GENERATOR | | | QUICK DISCONNECT" SWITCHBOARD AT THE RELOCATED | | | MSB.PLEASE SUBMIT SPECIFICATIONS FOR THIS AND ADD TO | | | THE RISER TO INDICATE LOCATION IN THE SERVICE SYSTEM. | | | | | | 6} E3.2, REVISION CANNOT REPLACE THE RISER ON THE | | | PERMIT SET. | | | | | | 7} E4.1 AND E4.2 DO NOT CORRELATE TO THE PANELS ON THE | | | PERMITTED SHEETS. THEY CONTAIN SCHEDULES NOT ON PERMIT | | | SET AND OMIT SCHEDULES CONTAINED ON THE PERMIT SET. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2007-02-21 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-02-21 |
Time |
17:00 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2007-02-13 |
Time |
14:20 |
Sent To |
PC |
|
| Notes |
| 2007-02-21 16:33:25 | | | | SWITCHGEAR SUBMITTAL NONCOMPLIANT | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE | | | COMPLIANCE AND RESUBMIT FOR REVIEW. | | | | | | THE SUBMITTAL FOR SWITCHBOARD MSB5 SHOWS IT BEING | | | LARGER THAN THE 6' MAXIMUM ALLOWED FOR THE ROOM IN | | | WHICH IT'S DESIGNATED TO BE INSTALLED, WHICH DOES NOT | | | CONFORM TO110.26(C)(2),"ENTRANCE--- AT EACH END" ALSO | | | WITH FRONT AND LEFT ACCESS REQUIRED, IT WILL NOT ALLOW | | | WORKING SPACE AT THE END OF THE GEAR. | | | | | | I AM RETURNING BOTH FULL SETS OF SUBMITTALS CONTAINING | | | THE SWITCHBOARD INFORMATION FOR CORRECTION OF MSB5. | | | | | | WILLIAM R. TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | CONSTRUCTION SERVICES DEPARTMENT | | | 561) 805-6718 | | 2007-02-21 12:54:06 | | | | SUBMITTAL REVISIION. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2006-12-20 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-12-20 |
Time |
12:20 |
Rev Time |
0.25 |
| Received By |
btrobaug |
Date |
2006-12-20 |
Time |
12:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2006-12-04 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-12-04 |
Time |
15:59 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2006-12-01 |
Time |
15:04 |
Sent To |
|
|
| Notes |
| 2006-12-04 15:59:15 | | | | | | | | | | THE PERMIT APPLICATION IS NOT WITH THE RESUBMITTED | | | PACKAGE, PLEASE INCLUDE IT WITH THE NEXT RESUBMITTAL. | | | THE PERMIT CANNOT BE ISSUED UNLESS THE APPLICATION IS | | | AVAILABLE. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW. | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-09-26 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-09-26 |
Time |
11:49 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2006-09-22 |
Time |
17:05 |
Sent To |
|
|
| Notes |
| 2006-09-26 00:00:00 | | | | | | | | | | NONCOMPLIANT | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} PLEASE SHOW COMPLIANCE WITH CHAPTER | | | 13, ENERGY CODE, SECTIONS 413,414 AND | | | 415 FOR LIGHTING CONTROLS. INDICATE | | | LOCATION OF EQUUIPMENT AND DEVICES SUCH | | | AS TIME CLOCKS AND OCCUPANCY SENSORS ON | | | THE PLAN. | | | | | | 2} MDP2 IS LISTED AS A MLO ON THE PLAN. | | | PLEASE CORRECT OR SHOW COMPLIANCE WITH | | | 230.71. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-06-16 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-06-16 |
Time |
17:42 |
Rev Time |
5.00 |
| Received By |
btrobaug |
Date |
2006-05-30 |
Time |
17:15 |
Sent To |
|
|
| Notes |
| 2006-06-16 00:00:00 | | | | | | | NONCOMPLIANT | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} PROVIDE PANEL SCHEDULES AND LOAD | | | CALCULATIONS FOR MSB5 AND PANELS A AND | | | B'S THAT IT FEEDS, 215.5 NEC, | | | 106.3.5.1.2 FBC. | | | | | | 2} INDICATE THE ELEVATION OF THE SERVICE | | | EQUIPMENT AND TRANSFORMERS, IN RELATION | | | TO THE ELECTRICAL DATUM PLANE. ARTICLE | | | 555.5. | | | | | | 3}PER 110.9 AND 110.10: OBTAIN THE | | | AVAILABLE FAULT CURRENT AT THE UTILITY | | | AND CALCULATE THE SAME AT THE EQUIPMENT. | | | INDICATE THE AIC RATING FOR THE | | | EQUIPMENT IS EQUAL TO OR GREATER THAN | | | THE AVAILABLE FAULT FOR MSB5 AND THE | | | PANELS IT FEEDS. | | | | | | 4} PROVIDE SPECIFICATIONS FOR ALL MAIN | | | SERVICE EQUIPMENT. | | | | | | 5} THE ELECTRIC ROOM IN BAY 1 THAT | | | HOUSES MSB5 IS NOT IN COMPLIANCE WITH | | | 110.26(C)(2). THE PANIC HARDWARE | | | REQUIRED IS NOT LISTED ON SHEET A-2.03 | | | FOR DOOR TYPE 1.12A. | | | | | | 6} INDICATE MSB5 COMPLIANCE WITH 230.71 | | | THROUGH 230.79. THERE IS NO INDICATION | | | OF A MAIN BREAKER ON THE PLAN. | | | | | | 7} THE EMERGENCY WALL PACKS IN THE | | | OFFICE LOBBY SHOULD BE ON CIRCUIT | | | "A1-23" TO COMPLY WITH 700.12(E). ALSO | | | THE LIGHTING SCHEDULE DOES NOT INDICATE | | | THESE ARE BATTERY BACK-UP, PER SAME | | | ARTICLE. | | | | | | 8} PROVIDE SCHEDULES, RATINGS AND | | | INDICATE COMPLIANCE WITH 230.71 THROUGH | | | 230.79 FOR MDP1 AND MDP2. | | | | | | 9} THE CODE REFERENCES FOR NFPA 101 AND | | | THE FLORIDA FIRE PREVENTION CODE ON | | | SHEET GN-01 ARE INCORRECT. THEY ARE 2003 | | | FOR 101 AND 2004 FOR FFP. SEE FBC | | | CHAPTER 35. PLEASE CORRECT ALL CODE | | | REFERENCES WHERE THEY APPEAR ON PLANS. | | | | | | 10} SEE ONE OF THE GN-01 SHEET ON ONE | | | SET OF PLANS DOES NOT CONTAIN ALL | | | INFORMATION THAT APPEARS ON THE OTHER | | | TWO. | | | | | | 11} INDICATE COMPLIANCE WITH CHAPTER 13, | | | ENERGY CODE, ON THE PLANS, 413 THROUGH | | | 415. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | | | | | | | | | | | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2006-08-15 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2006-08-15 |
Time |
13:49 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2006-08-15 |
Time |
13:49 |
Sent To |
Z |
|
| Notes |
| 2006-08-15 00:00:00 | ALL COMMENTS MADE BY M. AMINI IN 6/06 | | | WERE CORRECTED PER STEVE S. SO, MADE IT | | | PASS. | | | | | | RASIK CHOKSHI 805-6723 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2006-06-26 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2006-04-24 |
Time |
12:55 |
Rev Time |
0.00 |
| Received By |
MAMINI |
Date |
2006-06-26 |
Time |
13:05 |
Sent To |
I |
|
| Notes |
| 2006-04-24 00:00:00 | THESE NOTES UNDER 05110729 | | 2006-03-17 00:00:00 | FAILED: | | | | | | 1. PLEASE SUBMIT STORM WATER | | | CALCULATIONS AND INCLUDE PERVIOUS, | | | IMPERVIOUS, AND BUILDING AREA FOR THE | | | ENTIRE SITE. | | | 2. PLEASE SUBMIT A COPY OF SFWMD PERMIT. | | | 3. CITY CODE STATES NO NEW OUTFALL IN | | | LAKE WORTH WATERWAYS, ARE THEY APPROVED | | | BY STEVE SARLEY, AS PROPOSED. | | | 4. PLEASE ADDRESS ALL COMMENTS FROM | | | ENGINEERING SERVICES AND REVISE CIVIL | | | PLANS AS REQUIRED. | | | 5. PLEASE SUBMIT CALCULATION FOR THE | | | PROPOSED LIFT STATION. | | | | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2007-04-05 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-04-05 |
Time |
12:12 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-04-05 |
Time |
11:04 |
Sent To |
|
|
| Notes |
| 2007-04-05 12:12:21 | *****REVISIONS APPROVED***** | | | | | | | | | REVISED SHEETS A-2.04, A-2.05, A-5.01, FP2.1, FP2.2, | | | FP2.3, AND FP2.4 WERE STAMPED, INITIALED, AND DATED | | | | | | | | | *****PROVISO***** | | | | | | THE APPROPIATE REVISED ELECTRICAL SHEETS WILL BE | | | STAMPED WHEN THEIR PLAN REVIEW HAS BEEN SATISFIED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2007-03-21 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-03-21 |
Time |
17:16 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-03-21 |
Time |
16:48 |
Sent To |
|
|
| Notes |
| 2007-03-21 17:16:02 | *****SUBMITTAL RECEIVED***** | | | | | | | | | FIRE SPRINKLER PRODUCT DATA SUBMITTAL DATE STAMPED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2006-10-17 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2006-10-17 |
Time |
10:22 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2006-10-17 |
Time |
10:22 |
Sent To |
|
|
| Notes |
| 2006-10-17 10:48:40 | *****APPROVED***** | | | | | | | | | | | | RESPONSES TO THE 1ST FIRE PLAN REVIEW COMMENTS AS | | | FOLLOWS: | | | | | | | | | | | | | | | 1.)OK | | | | | | 2.)SO NOTED. | | | | | | 3.)SO NOTED. | | | | | | 4.)SO NOTED. | | | | | | 5.)SO NOTED. | | | | | | 6.)SO NOTED. | | | | | | 7.)OK | | | | | | 8.)OK | | | | | | 9.)OK | | | | | | 10.)OK | | | | | | 11.)SO NOTED. | | | | | | 12.)OK | | | | | | 13.)SO NOTED. | | | | | | 14.)SO NOTED.YOUR RESPONSE MENTIONS THAT THE | | | NUMERICAL ADDRESS WILL BE AS PER WEST PALM BEACH CODE. | | | PLEASE BE REMINDED THAT IN ADDITION TO THOSE NUMBERS | | | BEING NO LESS THAN 6" IN HEIGHT, THE SAME SAID NUMBERS | | | SHOULD ALSO BE NO LESS THAN 1" IN WIDTH.ALSO IN | | | ADDITION TO THE REQUIRED NUMERICAL ADDRESS ON THE | | | BUILDING, YOU WOULD ALSO HAVE THE NUMERICAL ADDRESS ON | | | THE MARQUEE AND/OR MONUMENT SIGN IF INSTALLED. | | | | | | 15.)SO NOTED. | | | | | | 16.)OK | | | | | | 17.)OK | | | | | | 18.)SO NOTED. | | | | | | 19.)SO NOTED. | | | | | | 20.)SO NOTED. | | | | | | 21.)OK | | | | | | 22.)OK | | | | | | | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2006-06-19 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2006-06-19 |
Time |
10:02 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2006-06-19 |
Time |
09:14 |
Sent To |
|
|
| Notes |
| 2006-06-19 00:00:00 | 1. CONSTRUCTION, DEMOLITION, AND | | | RENOVATION TO COMPLY WITH NFPA 241. | | | | | | 2. SUITABLE ROADS ARE TO PROVIDED DURING | | | CONSTRUCTION FOR FIRE AND PARAMEDICAL | | | EQUIPMENT. | | | | | | 3. WET FIRE HYDRANTS ARE REQUIRED PRIOR | | | TO, DURING, AND AFTER CONSTRUCTION. | | | | | | 4. PLEASE INDICATE HOW FIRE RESCUE | | | ENTERS THROUGH THE ROLL GATE FENCE. WHAT | | | SECURITY OR LOCKING ARRANGEMENTS WILL BE | | | PRESENT AND IS A KNOX-BOX BEING | | | PROPOSED. | | | | | | 5. PRIVATE FIRE SERVICE MAINS AND | | | HYDRANTS SHALL COMPLY WITH NFPA 24. THE | | | STANDARD FOR PRIVATE FIRE SERVICE MAINS | | | AND THEIR APPURTENANCES. | | | | | | 6. NEW PRIVATE FIRE HYDRANTS TO COMPLY | | | WITH UTILITY AND FIRE RESCUE STANDARDS. | | | | | | 7. FIRE HYDRANT # 8 SHOULD BE RELOCATED | | | IN FRONT OF GATE OR FENCE OPENING. | | | | | | 8. ALL FIRE HYDRANTS SHALL BE PROVIDED | | | WITH SEVEN AND HALF FEET CLEARANCE TO | | | THE FRONT AND SIDES AND FOUR FEET TO THE | | | REAR OF THEM. (PAGE C-21) | | | | | | 9. ALL PAVEMENT ROAD SYSTEMS SHALL BE | | | CAPABLE OF SUPPORTING 32 TONS FOR FIRE | | | EQUIPMENT. | | | | | | 10. ELECTRONIC SWITCHES, CHAIN AND LOCK | | | ARE REQUIRED ON FIRE LINE BACKFLOW | | | DEVICES. | | | | | | 11. SEPERATE PLANS AND PERMITS REQUIRED | | | FOR FIRE SPRINKLER AND FIRE ALARM | | | SYSTEM. | | | | | | 12. FIRE DEPARTMENT CONNECTIONS (FDC'S) | | | SHALL BE LOCATED NO FARTHER THAN 150 | | | FEET FROM FIRE HYDRANTS. | | | | | | 13. ALL FIRE DEPARTMENT CONNECTIONS | | | (FDC'S) SHALL BE POSITIONED SO THEY | | | CANNOT BE BLOCKED BY STORAGE, VESSELS, | | | EQUIPMENT, ETC. | | | | | | 14. BUILDING ADDRESSES REQUIRED ON | | | PROPER ELEVATIONS. A MINIMUM OF AT LEAST | | | 6" HIGH NUMBERS WITH 1" WIDTH SHALL BE | | | PROVIDED. | | | | | | 15. KNOX-BOXES WILL BE REQUIRED. | | | | | | 16. NO ILLUMINATED EXIT SIGNS OR | | | EMERGENCY LIGHTS SHOWN FOR COVERED WORK | | | SHED VESSEL AREAS. | | | | | | 17. PLEASE INDICATE ANY AND ALL | | | HAZARDOUS MATERIALS PLANNED TO BE STORED | | | AT THE NEW FACILITY. THESE MATERIALS | | | INCLUDE FLAMMABLE AND COMBUSTIBLE | | | LIQUIDS, CORROSIVES, OXIDIZERS, | | | FLAMMABLE GASES, POSIONS, ETC. | | | | | | 18. WHERE WILL FLAMMABLE LIQUIDS, | | | SOLVENTS, ETC. PLANNED TO BE STORED. | | | | | | 19. WHAT TYPE OF WORK IS PLANNED TO BE | | | PERFORMED WHERE THE VESSELS ARE TO BE | | | STORED. | | | | | | 20. NO FIRE RATED DOORS SHOWN ON DOOR | | | SCHEDULE. IS THERE NO FIRE RATING FOR | | | BAYS 15 AND 16 LOCATED DIRECTLY IN FRONT | | | OF THE VESSEL FIT UP AREA. | | | | | | 21. WHERE IS THE FIBERGLASS AND GELCOAT | | | MATERIALS PLANNED TO BE STORED OR | | | UTILIZED. | | | | | | 22. NEW FIRE ALARM SYSTEM SHALL MEET THE | | | REQUIREMENTS OF BEING MONITORED BY A | | | LICENSED UL LISTED CENTRAL STATION | | | APPROVED FOR CENTRAL STATION SERVICE. | | | | | | MIKE CARSILLO, CHIEF FIRE PREVENTION | | | OFFICER | | | 804-4709 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
13 |
Status |
N |
Date |
2007-07-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-07-24 |
Time |
16:49 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-07-24 |
Time |
16:49 |
Sent To |
E |
|
| Notes |
| 2007-07-24 16:50:16 | TO "BTROBAUG "DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2007-06-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-25 |
Time |
15:07 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-25 |
Time |
15:07 |
Sent To |
|
|
| Notes |
| 2007-07-10 13:40:21 | TO "COMM" BD#24 | | 2007-06-25 15:07:30 | WAITING FOR "COMM" BD--REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2007-04-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-04-18 |
Time |
09:28 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-04-18 |
Time |
09:28 |
Sent To |
|
|
| Notes |
| 2007-04-18 09:31:29 | TO "COMM" BD#46 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2007-03-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-24 |
Time |
16:45 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-24 |
Time |
16:45 |
Sent To |
|
|
| Notes |
| 2007-03-24 16:48:26 | TO "COMM" BD#55 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2007-03-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-06 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-06 |
Time |
11:42 |
Sent To |
|
|
| Notes |
| 2007-03-08 11:51:43 | TO "COMM"BD#20 | | 2007-03-06 11:42:21 | WAITING FOR "COMM" BD-REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2007-02-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-13 |
Time |
08:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-13 |
Time |
08:50 |
Sent To |
M |
|
| Notes |
| 2007-02-13 08:50:40 | TO "M" BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2007-02-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-13 |
Time |
08:39 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-13 |
Time |
08:39 |
Sent To |
E |
|
| Notes |
| 2007-02-13 08:39:42 | TO "BTROBAUG" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2007-02-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-13 |
Time |
08:34 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-13 |
Time |
08:34 |
Sent To |
P |
|
| Notes |
| 2007-02-13 08:35:03 | TO "P" BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2007-02-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-13 |
Time |
08:30 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-13 |
Time |
08:30 |
Sent To |
B |
|
| Notes |
| 2007-02-13 08:30:29 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-11-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-11-06 |
Time |
11:51 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-11-06 |
Time |
11:50 |
Sent To |
|
|
| Notes |
| 2006-11-08 09:52:25 | TO "COMM" BD#32/PLANS ON RACK--4 ROLLS AND 1 BOX | | 2006-11-06 11:51:15 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-08-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-07 |
Time |
09:34 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-07 |
Time |
09:34 |
Sent To |
|
|
| Notes |
| 2006-08-11 00:00:00 | TO "COMM" BD#43 | | 2006-08-07 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-04-18 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-06-26 |
Time |
13:05 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-18 |
Time |
13:58 |
Sent To |
|
|
| Notes |
| 2006-05-10 00:00:00 | TO "COMM" BD#38 | | 2006-04-18 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-06-26 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-06-26 |
Time |
12:59 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-03-17 |
Time |
09:47 |
Sent To |
|
|
| Notes |
| 2006-03-17 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
P |
Date |
2007-04-24 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-04-24 |
Time |
10:56 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-04-21 |
Time |
09:43 |
Sent To |
|
|
| Notes |
| 2007-04-21 11:08:43 | MECH REVISION PAGES: | | | M0.1, M0.2, M2.1, M2.2, M2.3, M2.4, M2.5, M3.1 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
N |
Date |
2007-03-29 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-03-29 |
Time |
10:21 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-03-29 |
Time |
09:13 |
Sent To |
|
|
| Notes |
| 2007-03-29 10:21:15 | THIS SUBMITTED REVISION ON HOLD PENDING COORDINATION | | | WITH REVISIONS SUBMITTED ON 3/9/07 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2007-03-19 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-03-19 |
Time |
14:47 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-03-19 |
Time |
09:00 |
Sent To |
|
|
| Notes |
| 2007-03-19 14:48:31 | MECHANICAL SUBMITTALS RECEIVED. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2007-03-12 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-03-12 |
Time |
15:26 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-03-09 |
Time |
10:15 |
Sent To |
|
|
| Notes |
| 2007-03-12 15:42:02 | -------------DENIED----------------- | | | | | | 1. PG M2.1 NOTE #3: FLAME SPREAD OF 25 OR LESS IS | | | REQUIRED IN PLENUMS PER FBC,M 602.2.1. PLAN STATES A | | | FLAME SPREAD OF 250 IS ACCEPTABLE. PLEASE CORRECT AND | | | RESUBMIT. | | | | | | 2. PG M2.1 - EF1 & EF2 ARE BOTH LOCATE IN A PLENUM | | | CEILING AREA, CAUSING DOWNSTREAM DUCTS UNDER POSITIVE | | | PRESSURE TO ALSO BE LOCATED IN A PLENUM. EXHAUST DUCTS | | | UNDER POSITIVE PRESSURE SHALL NOT BE LOCATED IN A | | | RETURN AIR PLENUM PER FBC,M 601.3. | | | | | | 3. PG M2.1 - EF1 IN BATHROOM UNDER RATED VERTICAL EXIT | | | ACCESS (STAIRWAY). THE EXHAUST DUCT WILL BE PENETRATING | | | ONE OR MORE RATED ASEMBLIES (SEE FBC 1019.1.5). THESE | | | OPENINGS SHALL BE PROTECTED PER FBC,M 607.5. | | | | | | 4. PG M2.3 & M2.4 PLAN SHOWS SUPPLY AIR DUCTS ENTERING | | | STAIR SERVING AS VERTICAL EXIT ENCLOSURES. THESE | | | OPENINGS ARE PROHIBITED PER FBC 1019.1.2. | | | | | | 5. A2.03 SHOWS A RATED WALL SEPARATING SPACES (SEE COL. | | | LINE 16) WHICH IS NOT SHOWN ON MECHANICAL REVISIONS. IF | | | PARTITIONS AND/OR RATED ASSEMBLIES WHICH ARE NOT SHOWN | | | ON MECHANICAL DRAWINGS ARE INSTALLED, THEY WILL IMPACT | | | THE MECHANICAL SYSTEM. A COMPLETE REVIEW OF THESE PAGES | | | CAN NOT BE DONE AT THIS TIME. PLEASE REVISE DRAWINS SO | | | THAT MECHANICAL AND ARCHITECTURAL PLANS CORRELATE SO A | | | COMPLETE REVIEW CAN BE PERFORMED. FBC 106.1.1. | | | | | | | | | REVIEWED BY: | | | RONALD J REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2006-10-10 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-10-10 |
Time |
14:18 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-10-10 |
Time |
10:52 |
Sent To |
|
|
| Notes |
| 2006-10-10 14:49:29 | PROVISO: | | | | | | SMOKE DETECTORS ARE REQUIRED IN SUPPLY AIR SYSTEMS WITH | | | A DESIGN CAPACITY GREATER THAN 2,000 CFM, PER 2004 FMC | | | 606.2.1.PLEASE NOTE, AHU SYSTEM 1 INDICATES A 5 TON | | | SYSTEM WHICH MAY HAVE THE CAPACITY TO PRODUCE GREATER | | | THAN 2,000 CFM.PLEASE VERIFY WITH MANUFACTURER. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT PATTY KRAUSS | | | AT (561)805-6719 OR E-MAIL [email protected]. | | 2006-10-10 13:01:53 | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-06-26 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-06-26 |
Time |
10:23 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-06-26 |
Time |
10:23 |
Sent To |
|
|
| Notes |
| 2006-06-26 00:00:00 | DENIED:2004 FLORIDA BUILDING CODE. | | | | | | 1.PLEASE PROVIDE INFORMATION AS TO | | | WHAT TYOE IF WORK WILL BE PERFORMED IN | | | THE DIFFERENT BAY'S. | | | | | | 2.PROVIDE MSDS SHEETS FOR ANY | | | HAZARDOUS LIQUIDS AND MATERIALS. | | | | | | 3.THE FOLLOWING FANS ARE LOCATED OVER | | | DOOR EXITS, BAY 12, 10, 3, 5, 7, & 14. | | | PLEASE NOTE, PER 2004 FMC 401.5.2, | | | IYTDIIR EXHAUST OPENINGS SHALL NOT BE | | | DIRECTED ONTO WALKWAYS AND SHALL BE | | | LOCATED AS NOT TO CREATE A NUISANCE. | | | | | | 4.TEF2 IS ALSO TERMINATING OVER A | | | DOOR. | | | | | | 5.HAZARDOUS EXHAUST SYSTEMS SHALL | | | COMPLY WITH 2004 FMC 510. | | | | | | 6.PLEASE PROVIDE ENERGY & SIZING | | | CALCULATIONS IN ACCORDANCE WITH 2004 FBC | | | CHAPTER 13, SECTION 13-400.0.ABC AND | | | 13-407.1ABC.1. | | | | | | 7.PLEASE PROVIDE FLOOD ELEVATION | | | CERTFICATE.PLEASE NOTE, THE CITY CODE | | | REQUIRES AND ADDITIONAL 6" TO THE | | | FEDERAL STANDARD. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
8 |
Status |
P |
Date |
2007-08-28 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-08-28 |
Time |
13:41 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-08-28 |
Time |
13:41 |
Sent To |
PC |
|
| Notes |
| 2007-08-28 13:56:15 | RESTAMP PLANS: | | | | | | ****************PROVISO**************** | | | PER FBC-2004 PLUMBING SECTION 604.9 WATER HAMMER | | | ARRESTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE | | | MANUFACTURER'S SPECIFICATIONS. | | | | | | NOTE: RESEARCH FOR THIS REVISION WAS ALSO DONE OFF OF | | | THE FOUNDATION PERMIT NUMBER 05110729. | | | | | | REVIEW BY MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL= [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
7 |
Status |
P |
Date |
2007-08-28 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-08-28 |
Time |
13:23 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-08-28 |
Time |
13:23 |
Sent To |
|
|
| Notes |
| 2007-08-28 13:37:35 | REVISION: NEW SHEETS P0.0, P2.1, P2.2, P2.3, P3.0 | | | | | | ****************PROVISO*************** | | | PER FBC-2004 PLUMBING SECTION 604.9 WATER HAMMER | | | ARRESTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE | | | MANUFACTURER'S SPECIFICATIONS. | | | | | | NOTE: RESEARCH FOR THIS REVISION WAS ALSO DONE OFF OF | | | THE FOUNDATION PERMIT NUMBER 05110729. | | | | | | REVIEW BY MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL= [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
6 |
Status |
F |
Date |
2007-08-24 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-08-24 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-08-24 |
Time |
14:16 |
Sent To |
PC |
|
| Notes |
| 2007-08-24 14:39:11 | RESTAMP DENIED | | | REFERENCE: | | | ** FBC-2004 PLUMBING. | | | ** FBC-2004 CHAPTER 1, THE CITY OF | | | WEST PALM BEACH AMENDMENTS. | | | ** FLORIDA ADMINISTRATIVE CODE. | | | ** FLORIDA STATUTES. | | | | | | 1. THE SUBMITTED SHEETS FOR THE RESTAMP DO NOT MATCH | | | THE APPROVED FILE SET OF PLANS. THESE SHEETS NEED TO BE | | | SUBMITTED AS A REVISION WITH TWO COMPLETE SETS OF | | | REVISED SHEETS. ALL CHANGES NEED TO BE CLOUDED WITH A | | | REVISION NUMBER. | | | NOTE: THE APPROVED FILE COPY SHEETS ARE IDENTIFIED AS | | | SUCH: P0.1, P2.1, P2.2 AND P2.3. | | | | | | NOTE: THE SHEETS SUBMITTED FOR THE RESTAMP ARE | | | IDENTIFIED AS SUCH: P0.0, P2.1, P2.2, P2.3 AND P3.0. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL= [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2007-03-17 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2007-03-17 |
Time |
09:13 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2007-03-17 |
Time |
06:06 |
Sent To |
|
|
| Notes |
| 2007-03-17 09:14:31 | PROVISO | | | PREVIOUS COMMENT | | | SHOCK ARRESTORS NOT AT THE TOP OF THE RISER |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2007-03-06 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-03-06 |
Time |
17:55 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-03-06 |
Time |
17:55 |
Sent To |
|
|
| Notes |
| 2007-03-06 17:55:46 | PLUMBING SUBMITTALS APPROVED |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2006-12-14 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-12-14 |
Time |
13:51 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-12-14 |
Time |
13:51 |
Sent To |
|
|
| Notes |
| 2006-12-15 11:30:32 | PROVISO: | | | 1)ALL DOORS TO ACCESSIBLE TOILET ROOMS | | | SHALL COMPLY WITH SECTION 11-4.13. DOORS | | | SHALL NOT SWING INTO THE CLEAR FLOOR | | | SPACE REQUIRED FOR ANY FIXTURE. | | | | | | 2) SHOCK ARRESTORS NOT AT THE TOP OF THE RISER |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2006-08-13 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-08-13 |
Time |
13:27 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-08-13 |
Time |
13:27 |
Sent To |
|
|
| Notes |
| 2006-08-13 00:00:00 | PAUL SCHMITZ | | | [email protected] | | | FBC 2004 PLUMBING CODE PLAN REVIEW | | | FBC2004 FUEL GAS CODEPLAN REVIEW | | | FBC 2004 CH 11, FL ACESSIBILITY CODE | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPT.1, ADMINISTRATION, 2004 EDITION | | | | | | UNSAT | | | 1) NOTE ONE, OK | | | | | | 2) SHT A-2.04 NOTE TWO, OK | | | | | | | | | 3)SHT A-2.04 UNSAT:NEW COMMENT | | | DOOR SWINGS INTO TURNING SPACE. | | | RESPONSE: SEE SHT A-301 | | | PROVIDE ASELEVATION DETAIL OF TOILET | | | ROOMS WITH DIMENSIONS. | | | 11-4.22 TOILET ROOMS. | | | 11-4.22.2 DOORS. | | | (1)ALL DOORS TO ACCESSIBLE TOILET ROOMS | | | SHALL COMPLY WITH SECTION 11-4.13. DOORS | | | SHALL NOT SWING INTO THE CLEAR FLOOR | | | SPACE REQUIRED FOR ANY FIXTURE. | | | 11-4.22.3 CLEAR FLOOR SPACE. | | | THE ACCESSIBLE FIXTURES AND CONTROLS | | | REQUIRED IN SECTIONS 11-4.22.4, | | | 11-4.22.5, 11-4.22.6 AND 11-4.22.7 SHALL | | | BE ON AN ACCESSIBLE ROUTE. | | | AN UNOBSTRUCTED TURNING SPACE COMPLYING | | | WITH SECTION 11-4.2.3 SHALL BE PROVIDED | | | WITHIN AN ACCESSIBLE TOILET ROOM. | | | THE CLEAR FLOOR SPACE AT FIXTURES AND | | | CONTROLS, THE ACCESSIBLE ROUTE, AND THE | | | TURNING SPACE MAY OVERLAP. | | | | | | 4-A) SHTS P0.1 UNSAT: NOT ADDRESSED. | | | PROVIDE ABBREVIATION FOR "SA" | | | NOT TO BE INSTALLED AT TOP OF RISER | | | NEW COMMENT. | | | 604.9 WATER HAMMER. | | | THE FLOW VELOCITY OF THE WATER | | | DISTRIBUTION SYSTEM SHALL BE CONTROLLED | | | TO REDUCE THE POSSIBILITY OF WATER | | | HAMMER. A WATER-HAMMER ARRESTOR SHALL BE | | | INSTALLED WHERE QUICK-CLOSING VALVES ARE | | | UTILIZED. WATER-HAMMER ARRESTORS SHALL | | | BE INSTALLED IN ACCORDANCE WITH THE | | | MANUFACTURER?S SPECIFICATIONS. | | | WATER-HAMMER ARRESTORS SHALL CONFORM TO | | | ASSE 1010. | | | | | | 4-B) SHTP0.1 NEW COMMENT | | | PLUMBING SPECIFICATIONS | | | MATERIALS: VALVES | | | REFERENCE TO NOTE "B" PROVIDE BALL | | | VALVES WITH LOCKING HANDLES FOR MEDICAL | | | GAS SYSTEMS. | | | PLEASE REMOVE NOTE, OR EXPLAIN USE. | | | | | | 5) SHT P2.3 UNSAT | | | SEE COMMENT 4-A, "SA" NOT ADDRESSED. | | | SEC.604.9WATER HAMMER ARRESTOR | | | REQUIRED ON I.M. | | | END OF COMMENTS QUESTIONS 561-805-6692 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-06-18 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-06-18 |
Time |
09:44 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-06-18 |
Time |
08:54 |
Sent To |
|
|
| Notes |
| 2006-06-18 00:00:00 | PAUL SCHMITZ | | | [email protected] | | | FBC 2004 PLUMBING CODE PLAN REVIEW | | | FBC2004 FUEL GAS CODEPLAN REVIEW | | | FBC 2004 CH 11, FL ACESSIBILITY CODE | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPT.1, ADMINISTRATION, 2004 EDITION | | | | | | UNSAT | | | 1) PLEASE SEE ANY POSSIBLE COMMENTS FROM | | | OTHER TRADES WHICH MAY AFFECT PLUMBING | | | PLANS. | | | | | | 2) SHT A-2.04 | | | PLUMBING FIXTURE REQUIRMENTS: | | | BUSINESS OCCUPANCY NOT LISTED. | | | EACH TENANT SPACE TO COMPLY WITH TABLE | | | 403.1 FOR MINIMUM FACILITIES. | | | ONE W/C & LAV, ONE SAFTEY SHOWER, ONE | | | DRINKING FOUNTAIN, ONE S/S. | | | | | | 2)SHT A-2.04 | | | PROVIDE A ELEVATION DETAIL OF TOILET | | | ROOMS AND DRINK FOUNTAINS WITH | | | DIMENSIONS. | | | 11-4.22 TOILET ROOMS. | | | 11-4.22.1 MINIMUM NUMBER. | | | TOILET FACILITIES REQUIRED TO BE | | | ACCESSIBLE BY SECTION 11-4.1 SHALL | | | COMPLY WITH SECTION 11-4.22. ACCESSIBLE | | | TOILET ROOMS SHALL BE ON AN ACCESSIBLE | | | ROUTE. | | | 11-4.22.2 DOORS. | | | (1)ALL DOORS TO ACCESSIBLE TOILET ROOMS | | | SHALL COMPLY WITH SECTION 11-4.13. DOORS | | | SHALL NOT SWING INTO THE CLEAR FLOOR | | | SPACE REQUIRED FOR ANY FIXTURE. | | | 11-4.22.3 CLEAR FLOOR SPACE. | | | THE ACCESSIBLE FIXTURES AND CONTROLS | | | REQUIRED IN SECTIONS 11-4.22.4, | | | 11-4.22.5, 11-4.22.6 AND 11-4.22.7 SHALL | | | BE ON AN ACCESSIBLE ROUTE. AN | | | UNOBSTRUCTED TURNING SPACE COMPLYING | | | WITH SECTION 11-4.2.3 SHALL BE PROVIDED | | | WITHIN AN ACCESSIBLE TOILET ROOM. THE | | | CLEAR FLOOR SPACE AT FIXTURES AND | | | CONTROLS, THE ACCESSIBLE ROUTE, AND THE | | | TURNING SPACE MAY OVERLAP. | | | 11-4.22.6 LAVATORIES AND MIRRORS. | | | IF LAVATORIES AND MIRRORS ARE PROVIDED, | | | THEN AT LEAST ONE OF EACH SHALL COMPLY | | | WITH SECTION 11-4.19. | | | 11-4.22.7 CONTROLS AND DISPENSERS. | | | IF CONTROLS, DISPENSERS, RECEPTACLES, OR | | | OTHER EQUIPMENT ARE PROVIDED, THEN AT | | | LEAST ONE OF EACH SHALL BE ON AN | | | ACCESSIBLE ROUTE AND SHALL COMPLY WITH | | | SECTION 11-4.27. | | | 11-4.23 BATHROOMS, BATHING FACILITIES | | | AND SHOWER ROOMS. | | | 11-4.23.1 MINIMUM NUMBER. | | | BATHROOMS, BATHING FACILITIES, OR SHOWER | | | ROOMS REQUIRED TO BE ACCESSIBLE BY | | | SECTION 11-4.1 SHALL COMPLY WITH SECTION | | | 11-4.23 AND SHALL BE ON AN ACCESSIBLE | | | ROUTE. | | | 11-4.23.2 DOORS. | | | DOORS TO ACCESSIBLE BATHROOMS SHALL | | | COMPLY WITH SECTION 11-4.13. DOORS SHALL | | | NOT SWING INTO THE FLOOR SPACE REQUIRED | | | FOR ANY FIXTURE. IF ONLY A TOILET ROOM | | | IS PROVIDED AT GRADE LEVEL, SUCH TOILET | | | ROOM SHALL HAVE A CLEAR OPENING OF NOT | | | LESS THAN 29 INCHES (737 MM). | | | 11-4.23.3 CLEAR FLOOR SPACE. | | | THE ACCESSIBLE FIXTURES AND CONTROLS | | | REQUIRED IN SECTIONS 11-4.23.4, | | | 11-4.23.5, 11-4.23.6, 11-4.23.7, | | | 11-4.23.8 AND 11-4.23.9 SHALL BE ON AN | | | ACCESSIBLE ROUTE. AN UNOBSTRUCTED | | | TURNING SPACE COMPLYING WITH SECTION | | | 11-4.2.3 SHALL BE PROVIDED WITHIN AN | | | ACCESSIBLE BATHROOM. THE CLEAR FLOOR | | | SPACES AT FIXTURES AND CONTROLS, THE | | | ACCESSIBLE ROUTE, AND THE TURNING SPACE | | | MAY OVERLAP. | | | | | | 3) SHTS P0.1 PLUMBING GENERAL NOTES #6 | | | CLARIFI USE OF DUCTILE IRON PIPE LESS | | | THAN 2 FEET UNDER GROUND. | | | PLUMBING FIXTURE SCHEDULE P-42, CLARIFI | | | TYPE OF SHOWER, SAFETY OR PERSONEL? | | | P-62B HOSE BIBB, PROVIDE VACUM BREAKER. | | | PLUMBING ABBREVATIONS: | | | PROVIDE ABBREVIATION FOR "SA" | | | | | | | | | 4) SHT P2.3 PROVIDE A ISOMETRIC DRAWING | | | FOR BUSINESS OFFICE, SANITARY AND WATER | | | PIPEING. INCLUDE DRINKING FOUNTAIN, | | | EMERGENCY SHOWER AND EYE WASH. | | | | | | END OF COMMENTS, QUESTIONS 561-805-6692 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
P |
Date |
2007-08-29 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2007-08-29 |
Time |
15:25 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2007-08-29 |
Time |
15:25 |
Sent To |
|
|
| Notes |
| 2007-08-29 15:25:52 | 8/29/07 | | | | | | LANDSCAPE AS-BUILTS APPROVED. | | | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER, | | | AT (561) 822-1435. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2007-07-22 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2007-07-22 |
Time |
21:00 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2007-07-22 |
Time |
21:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2007-04-30 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2007-04-30 |
Time |
23:45 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2007-04-30 |
Time |
23:45 |
Sent To |
|
|
| Notes |
| 2007-04-30 23:47:51 | ***REVISION FAILED*** | | | | | | PLEASE CLARIFY WHEN INTERIOR MODIFICATIONS WERE MADE, | | | INCREASE THE AMOUNT OF OFFICE SPACE FROM WHAT WAS | | | ORIGINALLY APPROVED.THE SITE PLAN SHOULD HAVE BEEN | | | REVISED ACCORDINGLY, SHOWING IN THE PARKING | | | CALCULATIONS THAT SUFFICIENT PARKING IS STILL BEING | | | PROVIDED.PLEASE PROVIDE A COPY OF THE LATEST SITE | | | PLAN, ACCURATELY REFELECTING THE SQUARE FOOTAGE | | | ALLOCATIONS TO EACH TYPE OF USE (OFFICE, WAREHOUSE, | | | ETC.). | | | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER, | | | AT (561) 822-1435. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2006-11-30 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2006-11-30 |
Time |
15:28 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2006-11-30 |
Time |
15:28 |
Sent To |
|
|
| Notes |
| 2006-11-30 15:30:15 | ***PASSED WITH PROVISOS*** | | | | | | 1) THE EXISTING BUILDING SHALL BE DEMOLISHED PRIOR TO | | | THE ISSUANCE OF A C.O. | | | | | | 2) THE TEMPORARY PENINSULA PARKING LOT SHALL BE | | | INSTALLED PRIOR TO THE ISSUANCE OF A C.O. | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT JOHN ROACH, SENIOR | | | PLANNER, AT (561) 822-1435. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2006-09-22 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2006-09-22 |
Time |
22:36 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2006-09-22 |
Time |
22:36 |
Sent To |
|
|
| Notes |
| 2006-09-22 00:00:00 | 9/22/06 ***FAILED*** | | | | | | 1) THE MTC BUILDING WILL NOT BE CO'D | | | UNTIL THE EXISTING BUILDING HAS BEEN | | | DEMOLISHED. | | | | | | 2) THE TEMPORARY PENINSULA PARKING | | | APPEARS TO BE LOCATED OUTSIDE OF THE | | | LIMITS OF WORK.THE CIVIL DRAWINGS | | | INDICATE THAT THIS WILL BE SUBMITTED | | | UNDER A SEPARATE PERMIT.THIS PARKING | | | MUST BE INSTALLED PRIOR TO THE ISSUANCE | | | OF A CO AS THIS IS REQUIRED PARKING FOR | | | THE MTC BUILDING. | | | | | | 3) IN ACCORDANCE WITH SECTION | | | 94-273(D)(30) OF THE CITY OF WEST PALM | | | BEACH ZONING AND LAND DEVELOPMENT | | | REGULATIONS, THE FOLLOWING SHALL BE | | | SUBMITTED REGARDING THE RELOCATED | | | HELIPAD: | | | | | | 3A) COPY OF THE LATEST FAA/FDOT PERMIT | | | FOR THE NEW HELIPAD LOCATION. | | | | | | 3B) STATEMENT OF PROPOSED HOURS AND | | | FREQUENCY OF USE. | | | | | | 3C) DIAGRAM INDICATING THE PROPOSED | | | FLIGHT PATHS WITHIN 1,000 FOOT RADIUS OF | | | THE HELIPAD. | | | | | | 4) PLEASE INCLUDE A COPY OF THE APPROVED | | | TREE REMOVAL LICENSE WITH THE PERMIT | | | APPLICATION. | | | | | | 5) INDICATE THE HEIGHT OF THE FENCE/GATE | | | LOCATED ON THE WEST SIDE OF THE "OPEN | | | STORAGE AREA."ALSO, PLEASE PROVIDE | | | DETAILS AS TO WHAT SCREENING WILL OCCUR | | | (SLATS IN THE FENCE, ETC.). | | | | | | 6) PROVIDE DETAILS AND/OR NOTES OF THE | | | FENCE/WALL/ETC. SURROUNDING THE | | | "CONTAINMENT AREA."ALSO, BE PROVIDE | | | DETAILS AS TO WHAT WILL BE STORED IN | | | THIS AREA. | | | | | | 7) THE PLANT LIST SHALL INCLUDE A PLANT | | | COUNT.PLEASE IDENTIFY THE SPECIES AS | | | SHADE TREES, FLOWERING TREES, PALMS, | | | SHRUBS, GROUNDCOVER, ETC. | | | | | | 8) THE SITE PLAN, LANDSCAPE PLAN AND | | | HORIZONTAL CONTROL PLAN DO NOT SHOW THE | | | LOCATION OF THE LIFT STATION.THIS | | | DRAMATICALLY INTERFERES WITH THE | | | PROPOSED LANDSCAPING. | | | | | | 9) PLEASE CLARIFY THE LOCATION OF THE | | | "TYPICAL 6' HGIH SECURITY FENCE." | | | | | | 10) THE BUILDING AND USE SQUARE FOOTAGES | | | SHOWN ON THE SITE PLAN DO NOT MATCH THE | | | FRONT SHEET OF THE ARHCITECTURAL | | | DRAWINGS.THIS AFFECTS THE REQUIRED | | | PARKING COUNT. | | | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, | | | SENIOR PLANNER, AT (561) 822-1435. |
|
|