Plan Review Details - Permit 06030614
Plan Review Stops For Permit 06030614
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2006-04-10 Cont ID  
Sent By mjacobs Date 2006-04-10 Time 09:23 Rev Time 0.00
Received By mjacobs Date 2006-04-10 Time 07:26 Sent To  
Notes
2006-04-10 00:00:00PROVISO
 BUILDING PROVISO:
 TO BE IN PLACE AT C.O.:
  
 1) 424.2.17.1 OUTDOOR SWIMMING POOLS.
 OUTDOOR SWIMMING POOLS SHALL BE PROVIDED
 WITH A BARRIER COMPLYING WITH
 424.2.17.1.1 THROUGH 424.2.17.1.14.
  
 424.2.17.1.5 CHILD SAFETY BARRIER
 ASTM D5034 100 LB TENSILE STRNGTH
 ASTM D3787 150 LB BALL BURST
 STRENGTH
  
 2) 13-612.1.ABC.2.3.2 COVERS REQUIRED.
 SPAS AND HEATED SWIMMING POOLS SHALL BE
 EQUIPPED WITH A COVER DESIGNED TO
 MINIMIZE HEAT LOSS.
  
 3) 11-4.13.6 MANEUVERING CLEARANCES AT
 DOORS.
 MINIMUM MANEUVERING CLEARANCES AT DOORS
 THAT ARE NOT AUTOMATIC OR POWER-ASSISTED
 SHALL BE AS SHOWN IN FIGURE 11-25 . THE
 FLOOR OR GROUND AREA WITHIN THE REQUIRED
 CLEARANCES SHALL BE LEVEL AND CLEAR. AT
 THE PULL SIDE OF DOORS A 18"MIN IS
 REQUIRED. SEE THE TWO SINGLE DOORS
 LEADING TO THE POOL. SHEETS S-1 AND S-2
 SHOW THE DOORS SWINGING IN WHILE SHEET
 S-5 SHOWS THE SAME DOORS SINGING OUT
 PLEASE CLARIFY.
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-09-20 Cont ID  
Sent By btrobaug Date 2006-09-20 Time 13:07 Rev Time 0.50
Received By btrobaug Date 2006-09-20 Time 11:59 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2006-09-14 Cont ID  
Sent By btrobaug Date 2006-09-14 Time 10:46 Rev Time 0.50
Received By btrobaug Date 2006-09-14 Time 10:40 Sent To P
Notes
2006-09-14 00:00:00 
  
 PROVIDE DETAILS ON THE POWER SOURCE FOR
 ALL ELECTRICAL EQUIPMENT. THIS
 INFORMATION MUST BE SUBMITTED BY THE
 ENGINEER OF RECORD FOR THE POOL PLANS.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2006-04-12 Cont ID  
Sent By btrobaug Date 2006-04-12 Time 16:37 Rev Time 0.75
Received By btrobaug Date 2006-04-12 Time 16:22 Sent To G
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2006-04-13 Cont ID  
Sent By jleech Date 2006-04-13 Time 07:05 Rev Time 0.00
Received By jleech Date 2006-04-13 Time 07:05 Sent To  
Notes
2006-04-13 00:00:00GAS PERMIT REQUIRED; A LICENSED GAS
 CONTRACTOR IS REQUIRED TO MAKE
 APPLICATION FOR A GAS PERMIT DRAWINGS
 REQUIRED.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-09-06 Cont ID  
Sent By adarroug Date 2006-09-06 Time 14:48 Rev Time 0.00
Received By adarroug Date 2006-09-06 Time 14:48 Sent To P
Notes
2006-09-06 00:00:00TO "P" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-04-06 Cont ID  
Sent By adarroug Date 2006-04-06 Time 10:21 Rev Time 0.00
Received By adarroug Date 2006-04-06 Time 10:21 Sent To E
Notes
2006-04-06 00:00:00TO "BOB"#1

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-04-13 Cont ID  
Sent By jleech Date 2006-04-13 Time 07:30 Rev Time 0.00
Received By jleech Date 2006-03-16 Time 13:31 Sent To  
Notes
2006-03-16 00:00:00TO "Z" BOX

Review Stop P PLUMBING
Rev No 3 Status P Date 2006-09-20 Cont ID  
Sent By kstevens Date 2006-09-20 Time 11:20 Rev Time 0.00
Received By kstevens Date 2006-09-20 Time 10:29 Sent To E
Notes
2006-09-20 00:00:00REVISION APPROVED - 1700GAL TANK AND
 INDIRECT WASTE TO SANT. FOR POOL FILTER
 BACKWASH WITH APPROVAL BY M. GONZALES
 FOR THE SANT. AND THE HEALTH DEPT FOR
 THE HOLDING TANK.

Review Stop P PLUMBING
Rev No 2 Status F Date 2006-09-14 Cont ID  
Sent By btrobaug Date 2006-09-14 Time 10:47 Rev Time 0.00
Received By kstevens Date 2006-09-14 Time 09:29 Sent To  
Notes
2006-09-14 00:00:00DENIED
 REFERENCE: FBC-2004 CHAPTER 1
  
 1. SINCE THIS IS THE DISCHARGE IS FROM
 THE POOL EQUIPMENT, THE POOL ENGINEER
 SHALL SIGN, SEAL, DATE ALL COPIES. TITLE
 BLOCKS WITH ALL REQUIRED INFORMATION IS
 REQUIRED ON EACH SHEET. SECTION 106.1
  
 2. SUBMIT A DETAIL FOR THE PAD THAT THE
 TANK WILL BE SET UPON. INDICATE THE
 THICKNESS OF THE SLAB AND INDICATE ANY
 REINFORCEMENT REQUIRED. THE TOTAL WEIGHT
 OF THE WATER IN THE TANK WILL BE 9,960
 LBS FOR 1,200 GALS. TO 14,161 LBS OF
 WATER FOR 1,700 GALS. PLUS THE WEIGHT OF
 THE STORAGE TANK. PLEASE PROVIDE
 CALCULATIONS INDICATING TOTAL WEIGHT.
 SUBMIT A DETAIL FOR THECONNECTIONS TO
 THE PAD SHOWING COMPLIANCE WITH THE
 REQUIREMENT TO MEET THE 140 MPH
 WINDLOAD. SECTION 106.1.1.
  
 3. PLANS SHALL BE ROUTED TO THE CITY
 ENGINEERING DEPT FOR APPROVAL PRIOR TO
 RESUBMITTING TO CONSTRUCTION SERVICES
 FOR APPROVAL AS A REVISION. (SEE
 ATTACHED LETTER).
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status P Date 2006-04-07 Cont ID  
Sent By jleech Date 2006-04-07 Time 13:11 Rev Time 0.00
Received By jleech Date 2006-04-07 Time 13:11 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2006-04-04 Cont ID  
Sent By eschneid Date 2006-04-04 Time 17:43 Rev Time 0.00
Received By eschneid Date 2006-04-04 Time 17:43 Sent To  
Notes
***NONE***