| 2006-04-06 00:00:00 | 1) ALL PLANS SUBMITTED AFTER OCTOBER, 1, |
| | 2004 SHALL BE DESIGNED TO THE 2004 |
| | FLORIDA BUILDING CODE. |
| | |
| | 2) 3105.4.2.1 |
| | THE WIND DESIGN LOADS FOR ANY FABRIC OR |
| | MEMBRANE-COVERED STRUCTURE DESIGNED WITH |
| | A QUICK REMOVAL OR BREAKAWAY MEMBRANE OR |
| | FABRIC AT WIND VELOCITIES OF 75 MPH, |
| | SHALL BE BASED ON THE FOLLOWING |
| | CRITERIA: |
| | 1.MINIMUM WIND VELOCITY OF 3-SECOND |
| | WIND GUST 90 MPH |
| | 2.IMPORTANCE FACTOR BASED ON LOW |
| | HAZARD TO HUMAN LIFE OF 0.77. |
| | 3.EXPOSURE CATEGORY B FOR OR C AS |
| | DEFINED IN CHAPTER 16 . SHOW A DETAIL |
| | DRAWING OF THE QUICK REMOVAL OR |
| | BREAKAWAY SYSTEM WHICH WILL BE USED. |
| | SEE FBC. SECTION 3501 FOR MORE |
| | INFORMATION ON LOADS AND DESIGN ETC. |
| | |
| | 3) 2004 FL. BLD CODE 1603.1.4 THE |
| | FOLLOWING INFORMATION RELATED TO WIND |
| | SHALL BE SHOWN ON THE CONSTRUCTION |
| | DRAWINGS, |
| | 1)- BASIC WIND SPEED, MPH |
| | 2)- WIND IMPORTANCE FACTOR, & BUILDING |
| | CATEGORY |
| | 3)- WIND EXPOSURE |
| | 4)- INTERNAL PRESSURE COEFFICIENT, |
| | 5)- COMPONENTS & CLADDING, THE DESIGN |
| | WIND PRESSURES IN TERMS OF PSF. |
| | |
| | 4) FL S S 713.13 |
| | NOTICE OF COMMENCEMENT, TO BE FILED |
| | WITH THE CLERK OF THE COURT BEFORE A |
| | PERMIT WILL BE ISSUED. NOTE: 713.13(2) |
| | IF THE WORK DESCRIBED IN THE NOTICE OF |
| | COMMENCEMENT IS NOT ACTUALLY COMMENCED |
| | WITHIN 90 DAYS AFTER THE RECORDING |
| | THEREOF, SUCH NOTICE IS NULL & VOID. |
| | |
| | MYRON JACOBS |
| | BUILDING PLAN REVIEWER |
| | TEL:(561)805-6726 |