Plan Review Details - Permit 06030400
| Plan Review Stops For Permit 06030400 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2006-08-28 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2006-08-28 |
Time |
14:07 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2006-08-28 |
Time |
14:07 |
Sent To |
PC |
|
| Notes |
| 2006-08-28 00:00:00 | | | | | | | *****PASSED REVISION***** | | | | | | UPDATE VALUE OF PERMIT TO COVER NEW | | | SCOPE OF WORK, THIS IS REQUIRED BEFORE | | | C/O CAN BE CALLED. STRUCTURAL CONCRETE | | | KNEE WALL IS NOT UNDER SCOPE OF GLASS | | | AND GLAZING CONTRACTOR BUT MAY BE | | | SUB-CONTRACTED TO LICENCED CONTRACTOR IF | | | WORK IS NOT THE PRIMARY PURPOSE OF THE | | | CONTRACT OR MORE THAN 49% OF THE TOTAL | | | PRIME CONTRACT. | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2006-05-18 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2006-05-18 |
Time |
09:02 |
Rev Time |
0.75 |
| Received By |
amorse |
Date |
2006-05-18 |
Time |
09:02 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-04-03 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2006-04-03 |
Time |
07:09 |
Rev Time |
0.75 |
| Received By |
amorse |
Date |
2006-04-03 |
Time |
07:09 |
Sent To |
PC |
|
| Notes |
| 2006-04-03 00:00:00 | | | | | | | DENIED | | | | | | 1) PRODUCT APPROVAL HAS NO IMPACT RATING | | | FOR THIS PRODUCT. NOA TO SHOW IMPACT | | | RATED GLASS AND FRAME AS PART OF PRODUCT | | | APPROVALS | | | | | | 2) A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT IS REQUIRED PRIOR TO | | | A PERMIT BEING ISSUED | | | | | | 3) THE PERMIT APPLICATION SHALL INCLUDE | | | TWO COPIES OF EACH PRODUCT APPROVAL THAT | | | IS RELEVANT PER 9B-72. THESE SHOULD | | | INCLUDE THE FLORIDA STATE APPROVAL COVER | | | PAGES, AND THE PRODUCT NOA THAT LISTS | | | THE SYSTEM COMPONENTS/ FASTENER LIST | | | PAGES, THE PAGES WITH THE CHOSEN | | | ASSEMBLY/ SYSTEM TO BE USED AND THE | | | GENERAL LIMITATIONS PAGE. ALL CAN BE | | | FOUND ON WWW.FLORIDABUILDING.ORG | | | (SEE ATTACHED FLORIDA COVER) | | | | | | 4) PROVIDE PLAN DRAWING OF BUILDING | | | SHOWING LOCATION OF WINDOWS | | | | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-08-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-28 |
Time |
08:59 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-28 |
Time |
08:59 |
Sent To |
B |
|
| Notes |
| 2006-08-28 00:00:00 | TO "AMORSE" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-05-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-17 |
Time |
11:52 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-17 |
Time |
11:52 |
Sent To |
B |
|
| Notes |
| 2006-05-17 00:00:00 | TO "AMORSE" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2006-04-03 |
Time |
|
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-03-10 |
Time |
13:52 |
Sent To |
|
|
| Notes |
| 2006-03-10 00:00:00 | TO "MISC" BOX#1 |
|
|
|
Account Summary | Usage Policy | Privacy Policy