Plan Review Details - Permit 06030376
Plan Review Stops For Permit 06030376
Review Stop B BUILDING (STRUCTURAL)
Rev No 9 Status P Date 2008-02-19 Cont ID  
Sent By shill Date 2008-02-19 Time 16:17 Rev Time 0.00
Received By shill Date 2008-02-19 Time 16:17 Sent To  
Notes
2008-02-19 16:30:18PROVISO - SUBMIT DETAIL 4/S222

Review Stop B BUILDING (STRUCTURAL)
Rev No 8 Status F Date 2008-02-04 Cont ID  
Sent By shill Date 2008-02-04 Time 09:34 Rev Time 0.00
Received By shill Date 2008-02-04 Time 09:34 Sent To  
Notes
2008-02-04 09:45:42****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 1.SHEET 4 S222 IS TO INCLUDE ALL INFORMATION REQUIRED
 BY FAC61G15-23.002.
  
 2.PLEASE INCORPORATE THE REVISION INTO THE PLAN
 SHEET(S) WHICH IT REPLACES.DOESN'T THIS AFFECT MORE
 THAN THE FOUNDATION PLAN, SUCH AS THE ELEVATIONS?THE
 OLD SHEETS IN OUR RECORD SET WILL BE VOIDED, REPLACED
 WITH THE NEW SHEETS.
  
 3.THE SKETCH IS NOT REFERENCED ON THE PLAN PROVIDED.
 DOES THIS DETAIL REPLACE ANOTHER DETAIL OR IS IT
 SUPPLEMENTARY?WHERE WILL THE 2'X6" REINFORCED
 CONCRETE BE INSTALLED, AND FOR WHAT LENGTH?PLEASE
 REVISE THE PLAN TO MAKE USE OF THIS DETAIL CLEAR.

Review Stop B BUILDING (STRUCTURAL)
Rev No 7 Status P Date 2008-01-17 Cont ID  
Sent By shill Date 2008-01-17 Time 12:03 Rev Time 0.00
Received By shill Date 2008-01-17 Time 12:03 Sent To  
Notes
2008-01-17 12:04:21RESTAMP OF TRUSS ENGINEERING, PARTIAL (REMOVED NON
 COMPLIANT SHEETS, SPOKE WITH CONTRACTOR AND ENGINEER)

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status P Date 2007-12-28 Cont ID  
Sent By shill Date 2007-12-28 Time 09:26 Rev Time 0.00
Received By shill Date 2007-12-28 Time 09:26 Sent To  
Notes
2007-12-28 09:26:52RESTAMP OK

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2007-01-29 Cont ID  
Sent By shill Date 2007-01-29 Time 18:34 Rev Time 0.00
Received By shill Date 2007-01-29 Time 18:34 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2007-01-23 Cont ID  
Sent By shill Date 2007-01-23 Time 14:02 Rev Time 0.00
Received By shill Date 2007-01-23 Time 14:02 Sent To  
Notes
2007-01-23 14:03:08REVISION

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2006-11-16 Cont ID  
Sent By alange Date 2006-11-16 Time 10:00 Rev Time 0.00
Received By alange Date 2006-11-16 Time 09:53 Sent To  
Notes
2006-11-16 10:00:42DENIED
  
 1. PLEASE SIGN AND SEAL BOTH SETS OF PLANS
 SUBMITTED.
  
 2.SKYLIGHTS SHOWN ON UN SIGNED ELECTRICAL PAGE.
  
 3.SUBMIT TWO COMPLETE SETS OF PRODUCT APPROVALS.
  
 4.ACORDING TO ICC BUILDING VALUATION DATA THE PERMIT
 VALUATION HAS BEEN REVISED TO $34,375.ADDITION PERMIT
 FEES ARE DUE.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 CONSTRUCTION SERVICES DEPARTMENT
 561-805-6672
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2006-08-25 Cont ID  
Sent By alange Date 2006-08-25 Time 14:14 Rev Time 1.50
Received By alange Date 2006-08-25 Time 11:19 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-04-07 Cont ID  
Sent By alange Date 2006-04-07 Time 08:33 Rev Time 2.00
Received By alange Date 2006-04-07 Time 08:28 Sent To  
Notes
2006-04-07 00:00:00DENIED
  
  
 1. 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE
 RE-RECORDED IF THE DESCRIBED IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
 2.MINIMUM FOOTING DEPTH BELOW GRADE IS
 12" R403.1.4
  
 3.BASED ON ICC BUILDING VALUATION DATA
 THE PERMIT VALUE HAS BEEN REVISED TO
 $25,594.ADDITIONAL PERMIT FEES ARE
 DUE.
  
 4. THERMATRUE DOOR MISSING STATE PRODUCT
 APPROVAL.
 ALL PRODUCT APPROVALS SUBMITTED WITH
 QUALITY ASSURANCE SHALL HAVE THE
 FOLLOWING STATE APPROVAL ATTACHED.
  
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A STATE PRODUCT APPROVAL
 SHEETS THAT LISTS THE PRODUCT IDENTITY
 NUMBER FROM THE STATE. IF THE PRODUCT
 DOES NOT HAVE STATEWIDE APPROVAL, SUBMIT
 AN APPLICATION FOR LOCAL PRODUCT
 APPROVAL OR SITE SPECIFIC FORM PER RULE
 9B-72. SEE ATTACHMENT.
 WWW.FLORIDABUILDING.ORG
  
 5.THOSE PRODUCT APPROVALS WHICH ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.WPB
 AMENDMENT TO FBC 106.3.3.
  
 6.SUBMIT TWO SETS OF TRUSS DRAWINGS
 FOR REVIEW PER 2004 FBC R-802.10.1
  
 7.A DESIGN PROFESSIONAL OR AN OWNER
 MUST ELECT ONE OR A COMBINATION OF
 LEVELS OF ALTERATION PURSUANT TO
 SECTIONS 303, 304 AND 305 OF THIS CODE.
 SHOW HOW PLANS WILL COMPLY WITH THE
 SECTION(S) SELECTED.2004 FBC EXISTING
 BUILDING 301.5
  
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. SUBMIT ONE COPY OF
 OLD PAGES FOR REFERENCE. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET
 OR SPECIFICATION PAGE WHERE THE CHANGES
 CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 ART LANGE
 CONSTRUCTION SERVICES DEPARTMENT
 BUILDING PLANS EXAMINER
 561-805-6672
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2008-02-14 Cont ID  
Sent By btrobaug Date 2008-02-14 Time 15:56 Rev Time 0.00
Received By btrobaug Date 2008-02-14 Time 15:56 Sent To B
Notes
2008-02-14 15:57:13 
  
 REVISION AND FILE SET TO SAMANTHA, MET WITH CONTRACTOR
 WHO WANTED BUILDING REVIEW ONLY FOR CHANGING GARAGE
 DOOR FROM DOUBLE TO SINGLE./WRT.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-08-24 Cont ID  
Sent By btrobaug Date 2006-08-24 Time 11:40 Rev Time 0.50
Received By btrobaug Date 2006-08-24 Time 11:15 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-03-24 Cont ID  
Sent By btrobaug Date 2006-03-24 Time 11:26 Rev Time 0.33
Received By btrobaug Date 2006-03-24 Time 11:16 Sent To P
Notes
2006-03-24 00:00:00 
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 250.32 TWO OR MORE BUILDINGS OR
 STRUCTURES SUPPLIED FROM A COMMON
 SERVICE.
 (A) GROUNDING ELECTRODE. WHERE TWO OR
 MORE BUILDINGS OR STRUCTURES ARE
 SUPPLIED FROM A COMMON AC SERVICE BY A
 FEEDER(S) OR BRANCH CIRCUIT(S), THE
 GROUNDING ELECTRODE(S) REQUIRED IN PART
 III OF THIS ARTICLE AT EACH BUILDING OR
 STRUCTURE SHALL BE CONNECTED IN THE
 MANNER SPECIFIED IN 250.32(B) OR (C).
 WHERE THERE ARE NO EXISTING GROUNDING
 ELECTRODES, THE GROUNDING ELECTRODE(S)
 REQUIRED IN PART III OF THIS ARTICLE
 SHALL BE INSTALLED.
  
 PLEASE INDICATE ON THE RISER .
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  

Review Stop I INCOMING/PROCESSING
Rev No 10 Status N Date 2008-02-07 Cont ID  
Sent By adarroug Date 2008-02-07 Time 16:37 Rev Time 0.00
Received By adarroug Date 2008-02-07 Time 16:37 Sent To E
Notes
2008-02-07 16:38:01TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2008-01-29 Cont ID  
Sent By adarroug Date 2008-01-29 Time 16:18 Rev Time 0.00
Received By adarroug Date 2008-01-29 Time 16:18 Sent To B
Notes
2008-01-29 16:18:37TO "SHILL" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2008-01-15 Cont ID  
Sent By adarroug Date 2008-01-15 Time 08:27 Rev Time 0.00
Received By adarroug Date 2008-01-15 Time 08:27 Sent To B
Notes
2008-01-15 08:27:57TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2007-12-18 Cont ID  
Sent By adarroug Date 2007-12-18 Time 09:48 Rev Time 0.00
Received By adarroug Date 2007-12-18 Time 09:47 Sent To B
Notes
2007-12-18 09:48:17TO "SHILL" DESK/RESTAMP

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2006-12-01 Cont ID  
Sent By adarroug Date 2006-12-01 Time 11:41 Rev Time 0.00
Received By adarroug Date 2006-12-01 Time 11:40 Sent To B
Notes
2006-12-01 11:41:24TO "LMARTINEZ" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-11-01 Cont ID  
Sent By alange Date 2006-11-16 Time 10:00 Rev Time 0.00
Received By adarroug Date 2006-11-01 Time 11:27 Sent To B
Notes
2006-11-01 11:27:53TO "ALANGE" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-08-22 Cont ID  
Sent By adarroug Date 2006-08-22 Time 13:29 Rev Time 0.00
Received By adarroug Date 2006-08-22 Time 13:29 Sent To E
Notes
2006-08-22 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-08-12 Cont ID  
Sent By adarroug Date 2006-08-12 Time 16:36 Rev Time 0.00
Received By adarroug Date 2006-08-12 Time 16:36 Sent To Z
Notes
2006-08-12 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-03-23 Cont ID  
Sent By dpalmer Date 2006-03-23 Time 16:33 Rev Time 0.00
Received By dpalmer Date 2006-03-23 Time 16:33 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-04-07 Cont ID  
Sent By alange Date 2006-04-07 Time 08:34 Rev Time 0.00
Received By alange Date 2006-03-10 Time 10:14 Sent To  
Notes
2006-03-10 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2006-03-24 Cont ID  
Sent By tgordon Date 2006-03-24 Time 14:58 Rev Time 0.15
Received By tgordon Date 2006-03-24 Time 14:58 Sent To B
Notes
2006-03-24 00:00:00*** NOTE ***
 1) A MECHANICAL PERMIT WILL BE REQUIRED
 DUE TO BATHROOM EXHAUST FAN AND DRYER
 VENT.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop P PLUMBING
Rev No 1 Status P Date 2006-03-24 Cont ID  
Sent By btrobaug Date 2008-02-15 Time 15:03 Rev Time 0.00
Received By jleech Date 2006-03-24 Time 14:13 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2006-08-19 Cont ID  
Sent By mmclean Date 2006-08-19 Time 06:17 Rev Time 0.00
Received By mmclean Date 2006-08-19 Time 06:17 Sent To I
Notes
2006-08-19 00:00:00APPROVED BY ZBA BOARD, VARIANCE CASE
 #3161 FOR A DETACHED GARAGE 6FT

Review Stop Z ZONING
Rev No 1 Status F Date 2006-11-16 Cont ID  
Sent By mmclean Date 2006-03-22 Time 16:29 Rev Time 0.00
Received By mmclean Date 2006-03-22 Time 15:17 Sent To I
Notes
2006-03-22 00:00:00DENIED,
 1. THE PROPOSED GARAGE MUST SIT BACK
 25FT FROM FRONT SETBACK. (FLAGLER ST)
 2. THE PROPOSED GARAGE MUST BE 12.5 FT
 FROM SIDE SETBACK. ( POINSETTIA AVE).
 3. THE PROPOSED GARAGE MUST BE A MINIMUM
 OF 6FT FROM THE MAIN STRUCTURE.
 4. THE SITEPLAN DOES NOT IDENTIFY THE
 LOCATION OF THE PROPOSED WORK.
 5. THE SITPLAN DOES NOT SHOW THE
 DIEMNSION OF LOT AND SETBACKS OF THE
 EXISTING STRUCTURE.
 6. PLEASE SHOW THE PROPOSED GARAGE ON
 THE TWO COPY OF SURVEY (THAT WAS
 SUBMITTED), SHOWING THE SETBACK SIDE &
 FRONT SETBACK AND DISTANCE FROM THE MAIN
 STRUCTURE.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720