| Plan Review Stops For Permit 06030234 |
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2006-07-08 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-07-08 |
Time |
12:06 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-07-08 |
Time |
12:06 |
Sent To |
|
|
| Notes |
| 2006-07-08 00:00:00 | REVISION: | | | TO PIPE SIZE, AS BUILT. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2006-05-03 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-05-03 |
Time |
09:30 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-05-03 |
Time |
09:29 |
Sent To |
|
|
| Notes |
| 2006-05-03 00:00:00 | GAS PSI VERIFIED BY FPU, IS ACCEPTABLE | | | AT THE BOILERS BY SKIP KNIGHT |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2006-03-14 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-03-14 |
Time |
13:32 |
Rev Time |
1.00 |
| Received By |
mperson |
Date |
2006-03-14 |
Time |
13:32 |
Sent To |
PC |
|
| Notes |
| 2006-03-14 00:00:00 | DENIED | | | REFERENCE: FLORIDA STATE STATUTES 489 | | | | | | ACCORDING TO FLORIDA STATE STATUTES 489 | | | A CLASS "A" REGISTERED AIR CONDITIONING | | | CONTRACTOR SHALL NOT WORK ON NATURAL GAS | | | OR POTABLE WATER. PERMIT APPLICATION IS | | | OUT OF SCOPE OF LICENSE. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561)805-6730 | | | FAX (561)805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561)805-6721 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-06-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-29 |
Time |
13:25 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-29 |
Time |
13:25 |
Sent To |
P |
|
| Notes |
| 2006-06-29 00:00:00 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-05-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-01 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-01 |
Time |
14:53 |
Sent To |
M |
|
| Notes |
| 2006-05-01 00:00:00 | TO "M" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-05-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-01 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-03-09 |
Time |
13:22 |
Sent To |
|
|
| Notes |
| 2006-03-09 00:00:00 | TO "M" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2006-05-03 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-05-03 |
Time |
11:28 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2006-05-03 |
Time |
11:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-03-13 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-03-13 |
Time |
13:47 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2006-03-13 |
Time |
13:46 |
Sent To |
G |
|
| Notes |
| 2006-03-13 00:00:00 | *** DENIED *** | | | 1) PLEASE PROVIDE MANUFACTURE'S | | | SPECIFICATION'S AND INSTALLATION | | | INSTRUCTIONS FOR BOILERS. | | | | | | 2) PLEASE PROVIDE DETAILED INFORMATION | | | (DRAWINGS) FOR BOILER VENTS AND VENT | | | CONNECTORS. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2006-05-03 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-05-03 |
Time |
09:34 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-05-03 |
Time |
09:32 |
Sent To |
M |
|
| Notes |
| 2006-05-03 00:00:00 | PSI CONFIRMED BY FPU SKIP KNIGHT IS | | | ACCEPTABLE AT THE BOILERS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-04-12 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-04-01 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-04-01 |
Time |
05:59 |
Sent To |
|
|
| Notes |
| 2006-04-01 00:00:00 | PAUL SCHMITZ | | | [email protected] | | | FBC 2004 PLUMBING CODE PLAN REVIEW | | | FBC2004 FUEL GAS CODEPLAN REVIEW | | | FBC 2004 CH 11, FL ACESSIBILITY CODE | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | | | | CHAPT.1, ADMINISTRATION, 2004 EDITION | | | | | | CONTACTED FPU SKIP KNIGHT, TO CONFIRM | | | DELIVERY PSI AT METER. | | | | | | |
|
|