| Plan Review Stops For Permit 06030171 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2006-04-05 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-04-05 |
Time |
15:21 |
Rev Time |
0.50 |
| Received By |
alange |
Date |
2006-04-05 |
Time |
15:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2006-04-26 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-04-26 |
Time |
11:41 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-04-26 |
Time |
09:56 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-03-23 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-03-23 |
Time |
13:46 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-03-23 |
Time |
13:09 |
Sent To |
M |
|
| Notes |
| 2006-03-23 00:00:00 | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} THE VALUE OF THE PERMIT MUST INCLUDE | | | ALL EQUIPMENT AND LABOR PER 108.3 FBC, | | | ATTACHED. | | | | | | 2} PLEASE SEE RESIDENTIAL PERMIT | | | APPLICATION REQUIREMENTS, | | | ATTACHED.PLEASE SEE THE SITE PLAN MUST | | | SHOW THE LOCATION OF ALL EQUIPMENT, | | | INCLUDING EXISTING SREVICE EQUIPMENT, | | | AND COMPLIANCE WITH 225.31 THROUGH | | | 225.39 NEC. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2006-04-04 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-04-04 |
Time |
13:56 |
Rev Time |
0.15 |
| Received By |
mperson |
Date |
2006-04-04 |
Time |
13:56 |
Sent To |
B |
|
| Notes |
| 2006-04-04 00:00:00 | NOTE: GAS PERMIT REQUIRED. GAS CONTRAC- | | | TOR TO SUBMIT PLANS WITH PERMIT | | | APPLICATION. ALL GAS INSPECTIONS TO BE | | | COMPLETE BEFORE FINAL RES-GEN INSPECTION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-04-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-25 |
Time |
10:54 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-25 |
Time |
10:54 |
Sent To |
E |
|
| Notes |
| 2006-04-25 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-04-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-17 |
Time |
09:11 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-17 |
Time |
09:11 |
Sent To |
Z |
|
| Notes |
| 2006-04-17 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-03-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-03-16 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-03-16 |
Time |
14:01 |
Sent To |
E |
|
| Notes |
| 2006-03-16 00:00:00 | TO "GEN-RES" BOX"E" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-04-05 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-04-05 |
Time |
15:22 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-03-07 |
Time |
16:16 |
Sent To |
|
|
| Notes |
| 2006-03-07 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2006-03-30 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-03-30 |
Time |
08:29 |
Rev Time |
0.15 |
| Received By |
tgordon |
Date |
2006-03-30 |
Time |
08:29 |
Sent To |
P |
|
| Notes |
| 2006-03-30 00:00:00 | *** PROVISO *** | | | 1)GENERATOR EXHUST MUST BE TEN FEET AWAY | | | FROM ANY BUILDING OPENINGS (WINDOWS, | | | DOORS, ROOF & EAVE VENTS), AND TEN FEET | | | AWAY FROM ADJECENT BUILDING OPENS. PER | | | 2004 FBC/M 401.5.1 . | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2006-04-04 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-04-04 |
Time |
13:55 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2006-04-04 |
Time |
13:55 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2006-04-24 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-04-24 |
Time |
13:28 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-04-24 |
Time |
13:28 |
Sent To |
I |
|
| Notes |
| 2006-04-24 00:00:00 | NOTE: GENERATOR CAN ONLY ENCROACH 4FT | | | UBTI A SETBACK. DIMENISON OF GENERATOR | | | IS 48"X28". |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2006-03-14 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-03-14 |
Time |
13:50 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-03-14 |
Time |
13:50 |
Sent To |
I |
|
| Notes |
| 2006-03-14 00:00:00 | DENIED, | | | 1. THE PROPOSED GENERATOR MUST BE THE | | | REQUIRED REAR SETBACK. | | | 2. GENERATOR MUST BE CLEARLY SHOWN ON | | | SURVEY (2 COPY) AND PROVIDE THE SETBACK | | | FOR SIDE/REAR. | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|