| Plan Review Stops For Permit 06030119 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
P |
Date |
2007-12-11 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2007-12-11 |
Time |
11:02 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2007-12-11 |
Time |
11:02 |
Sent To |
|
|
| Notes |
| 2007-12-11 11:03:35 | APPROVED RE-STAMP ENERGY CALCULATIONS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
P |
Date |
2006-09-14 |
|
|
Cont ID |
|
| Sent By |
rnuquist |
Date |
2006-09-14 |
Time |
17:29 |
Rev Time |
0.00 |
| Received By |
rnuquist |
Date |
2006-09-14 |
Time |
17:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2006-07-24 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-07-24 |
Time |
13:42 |
Rev Time |
0.33 |
| Received By |
alange |
Date |
2006-07-24 |
Time |
13:42 |
Sent To |
|
|
| Notes |
| 2006-07-24 00:00:00 | TRUSS DRAWINGS APPROVED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2006-07-05 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-07-05 |
Time |
14:09 |
Rev Time |
0.50 |
| Received By |
alange |
Date |
2006-07-05 |
Time |
14:09 |
Sent To |
|
|
| Notes |
| 2006-07-05 00:00:00 | SITE WALL REVISION DENIED | | | | | | 1.CHANGES TO PLANS SHALL BE DONE BY | | | THE DESIGNER OF RECORD. FS481 | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2006-06-27 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-06-27 |
Time |
10:51 |
Rev Time |
0.33 |
| Received By |
alange |
Date |
2006-06-27 |
Time |
10:51 |
Sent To |
|
|
| Notes |
| 2006-06-27 00:00:00 | TRUSS SUBMITTAL DENIED | | | | | | TRUSS DRAWINGS NOT SUBMITTED WITH ROOF | | | PLAN. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2006-05-25 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-05-25 |
Time |
13:49 |
Rev Time |
1.50 |
| Received By |
alange |
Date |
2006-05-25 |
Time |
11:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-05-09 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-05-09 |
Time |
14:01 |
Rev Time |
1.25 |
| Received By |
alange |
Date |
2006-05-09 |
Time |
13:49 |
Sent To |
|
|
| Notes |
| 2006-05-09 00:00:00 | DENIED | | | | | | | | | 6.ALL PRODUCT APPROVALS SUBMITTED WITH | | | QUALITY ASSURANCE SHALL HAVE THE | | | FOLLOWING STATE APPROVAL ATTACHED. | | | | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A STATE PRODUCT APPROVAL | | | SHEETS THAT LISTS THE PRODUCT IDENTITY | | | NUMBER FROM THE STATE. IF THE PRODUCT | | | DOES NOT HAVE STATEWIDE APPROVAL, SUBMIT | | | AN APPLICATION FOR LOCAL PRODUCT | | | APPROVAL OR SITE SPECIFIC FORM PER RULE | | | 9B-72. SEE ATTACHMENT. | | | WWW.FLORIDABUILDING.ORG | | | | | | | | | ART LANGE | | | CONSTRUCTION SERVICES DEPARTMENT | | | BUILDING PLANS EXAMINER | | | 561-805-6672 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-04-06 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-04-06 |
Time |
09:03 |
Rev Time |
3.00 |
| Received By |
alange |
Date |
2006-04-05 |
Time |
14:45 |
Sent To |
|
|
| Notes |
| 2006-04-06 00:00:00 | DENIED | | | | | | | | | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT | | | SHALL BE RECORDED AT PALM BEACH COUNTY | | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | | BLANK FORMS ARE AVAILABLE FROM THIS | | | OFFICE. | | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE | | | RE-RECORDED IF THE DESCRIBED IMPROVEMENT | | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | | 90 DAYS OF RECORDING. | | | | | | 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 3.BASED ON ICC BUILDING VALUATION DATA | | | THE PERMIT VALUE HAS BEEN REVISED TO | | | $451,531.ADDITIONAL PERMIT FEES ARE | | | DUE. | | | | | | | | | 4. FOOTING DEPTH BELOW GRADE SHALL BE A | | | MIN OF 12" R403.1.4 | | | | | | 5.PRODUCT APPROVALS REQUIRED FOR | | | LINTELS AND TRANSOM WINDOWS. | | | | | | 6.ALL PRODUCT APPROVALS SUBMITTED WITH | | | QUALITY ASSURANCE SHALL HAVE THE | | | FOLLOWING STATE APPROVAL ATTACHED. | | | | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A STATE PRODUCT APPROVAL | | | SHEETS THAT LISTS THE PRODUCT IDENTITY | | | NUMBER FROM THE STATE. IF THE PRODUCT | | | DOES NOT HAVE STATEWIDE APPROVAL, SUBMIT | | | AN APPLICATION FOR LOCAL PRODUCT | | | APPROVAL OR SITE SPECIFIC FORM PER RULE | | | 9B-72. SEE ATTACHMENT. | | | WWW.FLORIDABUILDING.ORG | | | | | | 7.THOSE PRODUCT APPROVALS WHICH ARE | | | REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL | | | FOR JURISDICTIONAL APPROVAL.WPB | | | AMENDMENT TO FBC 106.3.3. | | | | | | 8.SUBMIT TWO SETS OF TRUSS DRAWINGS | | | FOR REVIEW PER 2004 FBC R-802.10.1 | | | | | | | | | 9.GUARD RAILINGS SHALL COMPLY WITH | | | R-312.2 SHOW DETAIL ON PLANS. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. SUBMIT ONE COPY OF | | | OLD PAGES FOR REFERENCE. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET | | | OR SPECIFICATION PAGE WHERE THE CHANGES | | | CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | ART LANGE | | | CONSTRUCTION SERVICES DEPARTMENT | | | BUILDING PLANS EXAMINER | | | 561-805-6672 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
8 |
Status |
P |
Date |
2007-11-27 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-11-27 |
Time |
07:33 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-11-27 |
Time |
06:42 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
P |
Date |
2007-10-23 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-10-23 |
Time |
12:51 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-10-23 |
Time |
12:17 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2007-03-20 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-03-20 |
Time |
08:06 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2007-03-20 |
Time |
07:33 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2007-02-12 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-02-12 |
Time |
15:13 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2007-02-12 |
Time |
11:30 |
Sent To |
PC |
|
| Notes |
| 2007-02-12 13:06:02 | | | | | | | NONCOMPLIANT | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE | | | COMPLIANCE AND RESUBMIT FOR REVIEW. | | | | | | 1}THE EQUIPMENT GROUNDING CONDUCTOR MUST COMPLY WITH | | | 250.66. SEE NOTE #1 REGARDING THE SUM OF THE SERVICE | | | ENTRANCE CONDUCTORS:SIZE OF LARGEST UNGROUNDED | | | SERVICE-ENTRANCE CONDUCTOR OR EQUIVALENT AREA FOR | | | PARALLEL CONDUCTORSA (AWG/KCMIL)-250 MCM LATERAL= #2 | | | CU, OR PARALLEL 2/0 CONDUCTORS @0.137 X 2=0.274 | | | EQUIVALENT 300 MCM, WHICH WOULD ALSOREQUIRE A #2 | | | GEC. | | | | | | 2} THE GEC IS REQUIRED TO BE CONTINUOUS TO THE NEUTRAL | | | BOND PER 250.64. IT HAS NOW BEEN REMOVED FROM THE METER | | | AND TWO GEC'S HAVE BEEN INSTALLED IN THE DISCONNECTS, | | | BREAKING THE CONTINUOUS BOND. THIS COULD BE RESOLVED BY | | | PUTTING THE GEC IN THE METER ENCLOSURE. | | | | | | 3} THE #1/0 CONDUCTORS BEING RAN FROM THE METER TO THE | | | 200 AMP DISCONNECTS ARE NOT IN COMPLIANCEWITH | | | 310.15(B)(6) WHICH REQUIRE A 2/0 MINIMUM. SAME COMMENT | | | FOR THE FEEDERS FROM THE DISCONNECT TO THE PANELS. | | | | | | 3} THE #6 EQUIPMENT GROUNDS BEING RAN TO THE | | | DISCONNECTS FROM THE METER PARALLEL THE NEUTRAL AND | | | MUST BE REMOVED.THEY ARE OK FROM THE DISCONNECTS TO THE | | | PANELS. | | | | | | 4} THE 60 AMP POOL DISCONNECT IS LOCATED AT A SEPARATE | | | STRUCTURE BY DEFINITION ARTICLE 100, AND THEREFORE | | | NEEDS A GEC INSTALLED AT THAT LOCATION PER 250.32. THIS | | | WAS REDLINED ON THE 4/06 PLAN. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2006-06-29 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-06-29 |
Time |
16:05 |
Rev Time |
0.25 |
| Received By |
btrobaug |
Date |
2006-06-29 |
Time |
14:03 |
Sent To |
B |
|
| Notes |
| 2006-06-29 00:00:00 | | | | | | | CHANGES TO PLANS DRAWN BY THE ARCHITECT | | | MUST BE MADE TO THE ARCHITECT OF RECORD | | | PER CHAPTER 481 FS. | | | | | | | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-06-13 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-06-13 |
Time |
07:40 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2006-06-13 |
Time |
07:40 |
Sent To |
PC |
|
| Notes |
| 2007-03-20 08:06:17 | | | | | | | THIS REVISION WAS FOR A TEMPORARY SERVICE. THERE ARE NO | | | SHEETS ON THE MAIN PLANS, RATHER A 8.5" X 11". |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2006-04-27 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-04-27 |
Time |
16:02 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-04-27 |
Time |
14:51 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-03-22 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-03-22 |
Time |
12:49 |
Rev Time |
1.50 |
| Received By |
btrobaug |
Date |
2006-03-22 |
Time |
09:29 |
Sent To |
Z |
|
| Notes |
| 2006-03-22 00:00:00 | | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} THE RISER DIAGRAM INDICATES A | | | METER/MAIN AND TWO PANELS. THE PLAN | | | INDICATES A METER AND THREE PANELS, | | | PLEASE CORRELATE. | | | | | | 2} PANELS #2 & 3 ARE SHOWN AS MLO. | | | CONDUCTORS ENERING SEPARATE STRUCTURES | | | MUST HAVE A DISCONNECTING MEANS PER | | | 225.31 AN BE GROUNDED PER 250.32. THE | | | RISER AN DPANEL SCHEDULE ARE NOT IN | | | COMPLIANCE. | | | | | | 3} THE 1/0 SERVICE CONDUCTORSINDICATED | | | ON THE RISER TO FPL ARE TOO SMALL FOR A | | | 400 AMP SERVICE PER 310.15(B)(6). | | | | | | 4} THE PANEL MARKED #1 HAS CIRCUITS | | | 1'3'5'AND 7 ON A COMMON TRIP BREAKER | | | WITH ONLY ONE 10K LOAD INDICATED FOR TWO | | | AHU'S. | | | | | | 5} CIRCUITS 2&4, PANEL #1 SHOWS #14 WIRE | | | ON A 50 AMP BREAKER. SEE 310.16. | | | | | | 6} THE MINIMUM GROUNDING ELECTRODE | | | CONDUCTOR FOR A 400 AMP SERVICE IS 1/0 | | | CU PER 250.66. SEE RISER. | | | | | | 7} THE ELEVATOR SHOWN ON THE PLAN IS NOT | | | IN THE LOAD CALCULATION OR ON A PANEL | | | SCHEDULE . PLEASE INDICATE ALL EQUIPMENT | | | ON THE PLAN. | | | | | | 8} THE ROOMS ON THE FIRST AND SECOND | | | FLOOR, EXCEPT THE BATHS AND SITTING | | | ROOM, ALL NEED RECEPTACLES ADDED TO | | | COMPLY WITH THE SPACING REQUIREMENTS OF | | | 210.52(A)(1)&(2). SEE REVIEWED PLAN FOR | | | SOME REDLINED AREAS. | | | | | | 9} THE ATTIC AREA USED AS MECHANICAL | | | SPACE MUST HAVE LIGHT PER 210.70(A)(3) | | | AND RECEPTACLES PER 210.63. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
20 |
Status |
N |
Date |
2008-03-31 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-03-31 |
Time |
09:53 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-03-31 |
Time |
09:53 |
Sent To |
M |
|
| Notes |
| 2008-03-31 09:55:01 | TO "M" BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
19 |
Status |
N |
Date |
2008-03-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-03-13 |
Time |
14:04 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-03-13 |
Time |
14:04 |
Sent To |
M |
|
| Notes |
| 2008-03-13 14:05:15 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
18 |
Status |
N |
Date |
2007-12-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-12-06 |
Time |
10:15 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-12-06 |
Time |
10:15 |
Sent To |
B |
|
| Notes |
| 2007-12-06 10:16:15 | TO "LMARTINEZ" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
17 |
Status |
N |
Date |
2007-11-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-19 |
Time |
08:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-11-19 |
Time |
08:50 |
Sent To |
E |
|
| Notes |
| 2007-11-19 08:50:41 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
16 |
Status |
N |
Date |
2007-10-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-10-16 |
Time |
09:30 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-10-16 |
Time |
09:30 |
Sent To |
E |
|
| Notes |
| 2007-10-16 09:30:28 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
15 |
Status |
N |
Date |
2007-08-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-30 |
Time |
16:08 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-30 |
Time |
16:08 |
Sent To |
M |
|
| Notes |
| 2007-08-30 16:08:16 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
14 |
Status |
N |
Date |
2007-08-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-03 |
Time |
09:46 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-03 |
Time |
09:45 |
Sent To |
M |
|
| Notes |
| 2007-08-03 09:46:22 | TO "TGORDON" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
13 |
Status |
N |
Date |
2007-07-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-07-24 |
Time |
09:16 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-07-24 |
Time |
09:16 |
Sent To |
M |
|
| Notes |
| 2007-07-24 09:17:12 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2007-03-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-13 |
Time |
15:30 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-13 |
Time |
15:30 |
Sent To |
E |
|
| Notes |
| 2007-03-13 15:31:08 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2006-08-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-07 |
Time |
17:00 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-07 |
Time |
17:00 |
Sent To |
Z |
|
| Notes |
| 2006-08-07 00:00:00 | TO "Z" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2006-07-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-07-18 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-07-18 |
Time |
13:45 |
Sent To |
B |
|
| Notes |
| 2006-07-18 00:00:00 | TO "ALANGE" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2006-07-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-07-10 |
Time |
09:21 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-07-10 |
Time |
09:20 |
Sent To |
Z |
|
| Notes |
| 2006-07-10 00:00:00 | TO "Z" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2006-06-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-27 |
Time |
09:45 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-27 |
Time |
09:45 |
Sent To |
E |
|
| Notes |
| 2006-06-27 00:00:00 | TO "E" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2006-06-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-22 |
Time |
10:25 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-22 |
Time |
10:25 |
Sent To |
B |
|
| Notes |
| 2006-06-22 00:00:00 | TO "ALANGE" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-06-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-22 |
Time |
10:10 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-22 |
Time |
10:10 |
Sent To |
Z |
|
| Notes |
| 2006-06-22 00:00:00 | TO "Z" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-06-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-07 |
Time |
18:18 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-07 |
Time |
18:18 |
Sent To |
E |
|
| Notes |
| 2006-06-07 00:00:00 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-05-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-18 |
Time |
10:25 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-18 |
Time |
10:24 |
Sent To |
M |
|
| Notes |
| 2006-05-18 00:00:00 | TO "M" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-04-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-27 |
Time |
09:10 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-27 |
Time |
09:10 |
Sent To |
E |
|
| Notes |
| 2006-04-27 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-04-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-21 |
Time |
11:35 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-21 |
Time |
11:35 |
Sent To |
Z |
|
| Notes |
| 2006-04-21 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-04-06 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-04-06 |
Time |
09:04 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-03-06 |
Time |
16:20 |
Sent To |
|
|
| Notes |
| 2006-03-06 00:00:00 | TO "SFR" "Z" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
9 |
Status |
P |
Date |
2008-04-01 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-04-01 |
Time |
09:50 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2008-04-01 |
Time |
09:50 |
Sent To |
|
|
| Notes |
| 2008-04-01 09:52:11 | REVISION TO A/C EQUIPMENT SCHEDULE. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
8 |
Status |
F |
Date |
2008-03-14 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-03-14 |
Time |
10:49 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2008-03-14 |
Time |
10:49 |
Sent To |
|
|
| Notes |
| 2008-03-14 10:54:04 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | REVISION TO MECHANICAL PLANS | | | *** DENIED *** | | | 1) MECHANICAL PLANS ON FILE ARE SIGNED AND SEALED BY AN | | | ARCHITECT (JAMES C. PAINE) SO ONLY HE CAN MAKE | | | REVISIONS TO THEM. PLEASE HAVE HIM SIGN AND SEAL THE | | | REVISION OR SUBMIT A LETTER REMOVING HIMSELF FROM THE | | | PROJECT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
7 |
Status |
P |
Date |
2007-09-04 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-09-04 |
Time |
10:10 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2007-09-04 |
Time |
10:10 |
Sent To |
|
|
| Notes |
| 2007-09-04 10:10:55 | REVISION TO MECH. PLAN PAGE M-1. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
P |
Date |
2007-08-06 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-08-06 |
Time |
16:15 |
Rev Time |
0.15 |
| Received By |
tgordon |
Date |
2007-08-06 |
Time |
16:15 |
Sent To |
|
|
| Notes |
| 2007-08-06 16:18:02 | MECH. REVISION TO PAGE M-2 HAS BEEN APPROVED, REVISION | | | TO PAGE M-1 HAS BEEN DENIED DUE TO DRYER VENT CAP. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
F |
Date |
2007-08-06 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-08-06 |
Time |
15:40 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-08-06 |
Time |
15:40 |
Sent To |
|
|
| Notes |
| 2007-08-06 15:59:10 | ** MECHANICAL REVISION ** | | | *** DENIED *** | | | 1) THE DEFLECT-O ADJUSTABLE DIFFUSER SUBMITTED IS NOT | | | STATE THAT IT IS DESIGNED TO BE A CLOTHES DRYER VENT | | | CAP, PLEASE SUBMIT THE CLOTHES DRYER MANUFACTURER'S | | | INSTALLATION INSTRUCTIONS SHOWING THAT THIS TYPE OF CAP | | | MAY BE USED ON THEIR DRYER EXHAUST, AND INFORMATION | | | FROM DEFLECT-O SHOWING THAT IT IS UL APPROVED AS A | | | CLOTHES DRYER VENT CAP, SEE 2004 FBC M1501.1. | | | | | | **2004 FBC/R M1501.1 GENERAL. | | | DRYER EXHAUST SYSTEMS SHALL BE INDEPENDENT OF ALL OTHER | | | SYSTEMS, SHALL CONVEY THE MOISTURE TO THE OUTDOORS AND | | | SHALL TERMINATE ON THE OUTSIDE OF THE BUILDING. EXHAUST | | | DUCT TERMINATIONS SHALL BE IN ACCORDANCE WITH THE DRYER | | | MANUFACTURER'S INSTALLATION INSTRUCTIONS. SCREENS SHALL | | | NOT BE INSTALLED AT THE DUCT TERMINATION. EXHAUST DUCTS | | | SHALL NOT BE CONNECTED WITH SHEET-METAL SCREWS OR | | | FASTENING MEANS WHICH EXTEND INTO THE DUCT. EXHAUST | | | DUCTS SHALL BE EQUIPPED WITH A BACKDRAFT DAMPER. | | | EXHAUST DUCTS SHALL BE CONSTRUCTED OF MINIMUM | | | 0.016-INCH-THICK (0.406 MM) RIGID METAL DUCTS, HAVING | | | SMOOTH INTERIOR SURFACES WITH JOINTS RUNNING IN THE | | | DIRECTION OF AIR FLOW. FLEXIBLE TRANSITION DUCTS USED | | | TO CONNECT THE DRYER TO THE EXHAUST DUCT SYSTEM SHALL | | | BE LIMITED TO SINGLE LENGTHS, NOT TO EXCEED 8 FEET | | | (2438 MM) IN LENGTH AND SHALL BE LISTED AND LABELED IN | | | ACCORDANCE WITH UL 2158A. TRANSITION DUCTS SHALL NOT BE | | | CONCEALED WITHIN CONSTRUCTION. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2007-07-25 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-07-25 |
Time |
08:03 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-07-25 |
Time |
08:03 |
Sent To |
|
|
| Notes |
| 2007-07-25 08:34:34 | ** MECHANICAL REVISION ** | | | *** DENIED *** | | | 1) PLANS PAGE M-1 SHOWS THE RANGE HOOD VENT AND THE | | | CLOTHES DRYER VENT TERMINATING AT THE SOFFIT, PLEASE | | | SHOW A DETAIL HOW THIS IS BEING INSTALLED AND SUBMIT A | | | MANUFACTURERS SPECIFICATION SHEET FOR THE END CAP THAT | | | IS BEING USED, SEE 2004 FBC/R M1501.1 SCREENS SHALL NOT | | | BE INSTALLED AT DUCT TERMINATION AND SHALL BE EQUIPPED | | | WITH A BACKDRAFT DAMPER. | | | | | | 2) SEE YELLOW HIGH LIGHTS ON PLANS PAGE M-2 SHOWING | | | RETURN AIR DUCTS THAT NEED TO BE SIZED. | | | | | | 3) PAGE M-2 SHOWS ONLY ONE 8" RETURN AIR DUCT TO AHU-1 | | | AND ONE 10" RETURN AIR DUCT TO AHU-2 IF THIS IS THE | | | ONLY MEANS OF RETURN TO THE AIR HANDLERS THAT WOULD PUT | | | THEM AT A VELOCITY OF 4000 AND 2600, IF THIS IS THE | | | CASE PLEASE SUBMIT MANUAL D CALCULATIONS, DETAILED | | | MANUFACTURER'S SPECIFICATION'S FOR THE AIR HANDLER WITH | | | COOLING COIL, AND FLEX DUCTS. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2006-05-18 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-05-18 |
Time |
15:38 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2006-05-18 |
Time |
15:38 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2006-05-01 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-05-01 |
Time |
09:00 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2006-05-01 |
Time |
09:00 |
Sent To |
P |
|
| Notes |
| 2006-05-01 00:00:00 | *** DENIED *** | | | 1) RETURN AIR TRANSFER DUCT TO MASTER | | | SUITE IS TO SMALL, SEE NOTE #3(C) | | | EXCEPT. | | | | | | 2) RETURN AIR TRANSFER DUCTS TO DINING | | | ROOM AND OFFICE NEED TO BE SIZED. | | | | | | 3)BALANCED RETURN AIR. | | | THIS MAY BE ACHIEVED BY. | | | (A)TRANSFER DUCTS MAY ACHIEVE THIS BY | | | INCREASING THE RETURN TRANSFER ONE AND | | | ONE HALF TIMES THE CROSS SECTIONAL AREA | | | (SQUARE INCHES) OF THE SUPPLY DUCT | | | ENTERING THE ROOM OR SPACE IT'S SERVING | | | AND THE DOOR HAVING AT LEAST AN | | | UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE | | | PROPER RETURN AIR BALANCE. | | | (B)TRANSFER GRILLES SHALL USE 50 | | | SQUARE INCHES (OF GRILLE AREA) TO 100 | | | CFM (OF SUPPLY AIR) FOR SIZING | | | THROUGH-THE-WALL TRANSFER GRILLES AND | | | USING AN UNRESTRICTED 1-INCH | | | UNDERCUTTING OF DOORS TO ACHIEVE PROPER | | | RETURN AIR BALANCE | | | (C)HABITABLE ROOMS ONLY SHALL BE | | | REQUIRED TO MEET THESE REQUIREMENTS FOR | | | PROPER BALANCED RETURN AIR EXCLUDING | | | BATHROOMS, CLOSETS, STORAGE ROOMS AND | | | LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY | | | AIR INTO THE MASTER SUITE SHALL BE | | | INCLUDED. PER 2004 FBC/R M1602.4 . | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-03-08 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-03-08 |
Time |
15:47 |
Rev Time |
0.40 |
| Received By |
tgordon |
Date |
2006-03-08 |
Time |
15:47 |
Sent To |
Z |
|
| Notes |
| 2006-03-08 00:00:00 | *** DENIED *** | | | 1) ENERGY CALCULATIONS ARE CALLING FOR | | | 84,000 TOTAL BTU'S, MECHANICAL PLANS ARE | | | CALLING FOR 90,000 TOTAL BTU'S. THE | | | PLANS CAN NOT CALL FOR MORE THAN THE | | | ENERGY CAL'S, PLEASE CORRECT. | | | | | | 2) THE MANUAL J IS CALLING FOR A TOTAL | | | SENSIBLE BTU'S OF 56,203 AND THE MECH. | | | PLANS ARE CALLING FOR A TOTAL SENSIBLE | | | BTU'S OF 68,800. THE PLANS CAN ONLY CALL | | | FOR 20% MORE THAN THE MANUAL J, PER 2004 | | | FBC 13-607.1.ABC.1.1 .PLEASE CORRECT. | | | | | | 3) PLEASE SUBMIT MANUAL J (LONG FORM) | | | SHOWING DUCT SIZES AND CFM'S FOR EACH | | | ROOM. AS MECH. PLAN DUCT (FLEX) SIZES | | | AND CFM'S SHOWING WILL CAUSE TO LOW AN | | | AIR VELOCITY. | | | | | | 4) PROVIDE RETURN AIR FOR THE OFFICE AND | | | LIVING ROOM, SEE NOTE #6. | | | | | | 5) TRANSFER RETURN AIR DUCTS (FLEX) ON | | | SECOND FLOOR, NEED TO SHOW SIZES, SEE | | | NOTE #6. | | | | | | 6) BALANCED RETURN AIR. | | | THIS MAY BE ACHIEVED BY. | | | (A)TRANSFER DUCTS MAY ACHIEVE THIS BY | | | INCREASING THE RETURN TRANSFER ONE AND | | | ONE HALF TIMES THE CROSS SECTIONAL AREA | | | (SQUARE INCHES) OF THE SUPPLY DUCT | | | ENTERING THE ROOM OR SPACE IT'S SERVING | | | AND THE DOOR HAVING AT LEAST AN | | | UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE | | | PROPER RETURN AIR BALANCE. | | | (B)TRANSFER GRILLES SHALL USE 50 | | | SQUARE INCHES (OF GRILLE AREA) TO 100 | | | CFM (OF SUPPLY AIR) FOR SIZING | | | THROUGH-THE-WALL TRANSFER GRILLES AND | | | USING AN UNRESTRICTED 1-INCH | | | UNDERCUTTING OF DOORS TO ACHIEVE PROPER | | | RETURN AIR BALANCE | | | (C)HABITABLE ROOMS ONLY SHALL BE | | | REQUIRED TO MEET THESE REQUIREMENTS FOR | | | PROPER BALANCED RETURN AIR EXCLUDING | | | BATHROOMS, CLOSETS, STORAGE ROOMS AND | | | LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY | | | AIR INTO THE MASTER SUITE SHALL BE | | | INCLUDED. PER 2004 FBC/R M1602.4 . | | | | | | 7) PLEASE SHOW LOCATION AND SIZES OF | | | MAIN RETURN AIR GRILLS TO AIR HANDLERS. | | | | | | 8) PLEASE SHOW LOCATION OF DRYER VENT ON | | | MECH. PLANS. | | | | | | 9) PLEASE SUBMIT DETAILED MANUFACTURE'S | | | SPECIFICATION'S AND INSTALLATION | | | INSTRUCTIONS FOR GAS FIRE PLACE. | | | | | | 10) PLEASE PROVIDE COMBUSTION AIR | | | CALCULATIONS ON MECHANICAL PLANS, FOR | | | GAS FIRE PLACE. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2006-05-05 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-05-05 |
Time |
09:36 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-05-05 |
Time |
09:36 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-03-24 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-03-24 |
Time |
09:56 |
Rev Time |
0.75 |
| Received By |
jleech |
Date |
2006-03-24 |
Time |
09:56 |
Sent To |
Z |
|
| Notes |
| 2006-03-24 00:00:00 | DENIED; | | | RISER DIAGRAM NOT TO CODE; | | | FIRST FLOOR | | | 1.1/2 BATH TOILET NOT VENTED. FBC-2004 | | | PLUMBING SEC.909.1. | | | 2.AUTOMATIC CLOTHES WASHER AND LAUNDRY | | | TUB NOT VENTED. CLEANOT REQUIRED ON | | | WASHER AT 48" AFF. | | | 3.AUTOMATIC CLOTHES WASHER DRAIN TO BE | | | 3" SEE SEC. 406.3. | | | SECOND FLOOR | | | 1.TUB NOT VENTED. | | | 2.BIDET NOT VENTED | | | 3.URINAL NOT VENTED. | | | 4.AUTOMATIC CLOTHES WASHER DRAIN TO BE | | | 3" SEC.406.3 | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2006-06-25 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-06-25 |
Time |
15:19 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-06-25 |
Time |
15:19 |
Sent To |
I |
|
| Notes |
| 2006-06-25 00:00:00 | DENIED, | | | 1. MUST PULL A SEPERATE PERMIT FOR WALL | | | WITH UTILITY EASEMENT APPROVAL FROM THE | | | CITY OF WEST PALM BEACH UTILITY DEPT. | | | (AS MENTION IN REVIEW 3/27/06) | | | 2. PLEASE PROVIDE A COPY OF CURRENT | | | SURVEY WITHE THE SITEPLAN SHOWING THE | | | LOCATION OF THE PROPOSED WALL/COLUMNS | | | | | | NOTE: THE MAXIMUM HEIGHT ALLOWED WITHIN | | | THE FIRST 25FT FRONT SETBACK IS 4FT | | | ONLY. BEYOND THE 25FT FRONT SETBACK THE | | | MAXIMUM HEIGHT ALLOWED IS 6FT ONLY. | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2006-04-26 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-04-26 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-04-26 |
Time |
15:53 |
Sent To |
I |
|
| Notes |
| 2006-04-26 00:00:00 | LETTER ATTACHED FOR THE 15FT ALLEY | | | ABANDONED BY THE CITY. RES #72-73 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2006-03-27 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-03-27 |
Time |
08:16 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-03-27 |
Time |
08:16 |
Sent To |
B |
|
| Notes |
| 2006-03-27 00:00:00 | DENIED, | | | 1. MUST PROVIDED PROOF OF THE 15FT ALLEY | | | BEING ABANDONED (BY THE CITY - | | | ENGINEERING DEPT). | | | | | | | | | NOTE: MUST PULL A SEPERATE PERMIT FOR | | | POOL/SPA/DECK/SCREEN ENCLOSURE. | | | NOTE: MUST PULL A SEPERATE PERMIT FOR | | | FENCE/WALL/GATE WITH EASEMENT APPROVAL | | | FROM CITY OF WEST PALM BEACH UTILITY | | | DEPT. | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|