Plan Review Details - Permit 06030119
Plan Review Stops For Permit 06030119
Review Stop B BUILDING (STRUCTURAL)
Rev No 8 Status P Date 2007-12-11 Cont ID  
Sent By lmartine Date 2007-12-11 Time 11:02 Rev Time 0.00
Received By lmartine Date 2007-12-11 Time 11:02 Sent To  
Notes
2007-12-11 11:03:35APPROVED RE-STAMP ENERGY CALCULATIONS

Review Stop B BUILDING (STRUCTURAL)
Rev No 7 Status P Date 2006-09-14 Cont ID  
Sent By rnuquist Date 2006-09-14 Time 17:29 Rev Time 0.00
Received By rnuquist Date 2006-09-14 Time 17:29 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status P Date 2006-07-24 Cont ID  
Sent By alange Date 2006-07-24 Time 13:42 Rev Time 0.33
Received By alange Date 2006-07-24 Time 13:42 Sent To  
Notes
2006-07-24 00:00:00TRUSS DRAWINGS APPROVED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status F Date 2006-07-05 Cont ID  
Sent By alange Date 2006-07-05 Time 14:09 Rev Time 0.50
Received By alange Date 2006-07-05 Time 14:09 Sent To  
Notes
2006-07-05 00:00:00SITE WALL REVISION DENIED
  
 1.CHANGES TO PLANS SHALL BE DONE BY
 THE DESIGNER OF RECORD. FS481
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2006-06-27 Cont ID  
Sent By alange Date 2006-06-27 Time 10:51 Rev Time 0.33
Received By alange Date 2006-06-27 Time 10:51 Sent To  
Notes
2006-06-27 00:00:00TRUSS SUBMITTAL DENIED
  
 TRUSS DRAWINGS NOT SUBMITTED WITH ROOF
 PLAN.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2006-05-25 Cont ID  
Sent By alange Date 2006-05-25 Time 13:49 Rev Time 1.50
Received By alange Date 2006-05-25 Time 11:53 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-05-09 Cont ID  
Sent By alange Date 2006-05-09 Time 14:01 Rev Time 1.25
Received By alange Date 2006-05-09 Time 13:49 Sent To  
Notes
2006-05-09 00:00:00DENIED
  
  
 6.ALL PRODUCT APPROVALS SUBMITTED WITH
 QUALITY ASSURANCE SHALL HAVE THE
 FOLLOWING STATE APPROVAL ATTACHED.
  
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A STATE PRODUCT APPROVAL
 SHEETS THAT LISTS THE PRODUCT IDENTITY
 NUMBER FROM THE STATE. IF THE PRODUCT
 DOES NOT HAVE STATEWIDE APPROVAL, SUBMIT
 AN APPLICATION FOR LOCAL PRODUCT
 APPROVAL OR SITE SPECIFIC FORM PER RULE
 9B-72. SEE ATTACHMENT.
 WWW.FLORIDABUILDING.ORG
  
  
 ART LANGE
 CONSTRUCTION SERVICES DEPARTMENT
 BUILDING PLANS EXAMINER
 561-805-6672
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-04-06 Cont ID  
Sent By alange Date 2006-04-06 Time 09:03 Rev Time 3.00
Received By alange Date 2006-04-05 Time 14:45 Sent To  
Notes
2006-04-06 00:00:00DENIED
  
  
 1. 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE
 RE-RECORDED IF THE DESCRIBED IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 3.BASED ON ICC BUILDING VALUATION DATA
 THE PERMIT VALUE HAS BEEN REVISED TO
 $451,531.ADDITIONAL PERMIT FEES ARE
 DUE.
  
  
 4. FOOTING DEPTH BELOW GRADE SHALL BE A
 MIN OF 12" R403.1.4
  
 5.PRODUCT APPROVALS REQUIRED FOR
 LINTELS AND TRANSOM WINDOWS.
  
 6.ALL PRODUCT APPROVALS SUBMITTED WITH
 QUALITY ASSURANCE SHALL HAVE THE
 FOLLOWING STATE APPROVAL ATTACHED.
  
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A STATE PRODUCT APPROVAL
 SHEETS THAT LISTS THE PRODUCT IDENTITY
 NUMBER FROM THE STATE. IF THE PRODUCT
 DOES NOT HAVE STATEWIDE APPROVAL, SUBMIT
 AN APPLICATION FOR LOCAL PRODUCT
 APPROVAL OR SITE SPECIFIC FORM PER RULE
 9B-72. SEE ATTACHMENT.
 WWW.FLORIDABUILDING.ORG
  
 7.THOSE PRODUCT APPROVALS WHICH ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.WPB
 AMENDMENT TO FBC 106.3.3.
  
 8.SUBMIT TWO SETS OF TRUSS DRAWINGS
 FOR REVIEW PER 2004 FBC R-802.10.1
  
  
 9.GUARD RAILINGS SHALL COMPLY WITH
 R-312.2 SHOW DETAIL ON PLANS.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. SUBMIT ONE COPY OF
 OLD PAGES FOR REFERENCE. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET
 OR SPECIFICATION PAGE WHERE THE CHANGES
 CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 ART LANGE
 CONSTRUCTION SERVICES DEPARTMENT
 BUILDING PLANS EXAMINER
 561-805-6672
  

Review Stop E ELECTRICAL
Rev No 8 Status P Date 2007-11-27 Cont ID  
Sent By btrobaug Date 2007-11-27 Time 07:33 Rev Time 0.00
Received By btrobaug Date 2007-11-27 Time 06:42 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 7 Status P Date 2007-10-23 Cont ID  
Sent By btrobaug Date 2007-10-23 Time 12:51 Rev Time 0.00
Received By btrobaug Date 2007-10-23 Time 12:17 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 6 Status P Date 2007-03-20 Cont ID  
Sent By btrobaug Date 2007-03-20 Time 08:06 Rev Time 0.50
Received By btrobaug Date 2007-03-20 Time 07:33 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 5 Status F Date 2007-02-12 Cont ID  
Sent By btrobaug Date 2007-02-12 Time 15:13 Rev Time 1.00
Received By btrobaug Date 2007-02-12 Time 11:30 Sent To PC
Notes
2007-02-12 13:06:02 
  
 NONCOMPLIANT
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE
 COMPLIANCE AND RESUBMIT FOR REVIEW.
  
 1}THE EQUIPMENT GROUNDING CONDUCTOR MUST COMPLY WITH
 250.66. SEE NOTE #1 REGARDING THE SUM OF THE SERVICE
 ENTRANCE CONDUCTORS:SIZE OF LARGEST UNGROUNDED
 SERVICE-ENTRANCE CONDUCTOR OR EQUIVALENT AREA FOR
 PARALLEL CONDUCTORSA (AWG/KCMIL)-250 MCM LATERAL= #2
 CU, OR PARALLEL 2/0 CONDUCTORS @0.137 X 2=0.274
 EQUIVALENT 300 MCM, WHICH WOULD ALSOREQUIRE A #2
 GEC.
  
 2} THE GEC IS REQUIRED TO BE CONTINUOUS TO THE NEUTRAL
 BOND PER 250.64. IT HAS NOW BEEN REMOVED FROM THE METER
 AND TWO GEC'S HAVE BEEN INSTALLED IN THE DISCONNECTS,
 BREAKING THE CONTINUOUS BOND. THIS COULD BE RESOLVED BY
 PUTTING THE GEC IN THE METER ENCLOSURE.
  
 3} THE #1/0 CONDUCTORS BEING RAN FROM THE METER TO THE
 200 AMP DISCONNECTS ARE NOT IN COMPLIANCEWITH
 310.15(B)(6) WHICH REQUIRE A 2/0 MINIMUM. SAME COMMENT
 FOR THE FEEDERS FROM THE DISCONNECT TO THE PANELS.
  
 3} THE #6 EQUIPMENT GROUNDS BEING RAN TO THE
 DISCONNECTS FROM THE METER PARALLEL THE NEUTRAL AND
 MUST BE REMOVED.THEY ARE OK FROM THE DISCONNECTS TO THE
 PANELS.
  
 4} THE 60 AMP POOL DISCONNECT IS LOCATED AT A SEPARATE
 STRUCTURE BY DEFINITION ARTICLE 100, AND THEREFORE
 NEEDS A GEC INSTALLED AT THAT LOCATION PER 250.32. THIS
 WAS REDLINED ON THE 4/06 PLAN.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2006-06-29 Cont ID  
Sent By btrobaug Date 2006-06-29 Time 16:05 Rev Time 0.25
Received By btrobaug Date 2006-06-29 Time 14:03 Sent To B
Notes
2006-06-29 00:00:00 
  
 CHANGES TO PLANS DRAWN BY THE ARCHITECT
 MUST BE MADE TO THE ARCHITECT OF RECORD
 PER CHAPTER 481 FS.
  
  
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-06-13 Cont ID  
Sent By btrobaug Date 2006-06-13 Time 07:40 Rev Time 0.33
Received By btrobaug Date 2006-06-13 Time 07:40 Sent To PC
Notes
2007-03-20 08:06:17 
  
 THIS REVISION WAS FOR A TEMPORARY SERVICE. THERE ARE NO
 SHEETS ON THE MAIN PLANS, RATHER A 8.5" X 11".

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-04-27 Cont ID  
Sent By btrobaug Date 2006-04-27 Time 16:02 Rev Time 0.50
Received By btrobaug Date 2006-04-27 Time 14:51 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-03-22 Cont ID  
Sent By btrobaug Date 2006-03-22 Time 12:49 Rev Time 1.50
Received By btrobaug Date 2006-03-22 Time 09:29 Sent To Z
Notes
2006-03-22 00:00:00 
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} THE RISER DIAGRAM INDICATES A
 METER/MAIN AND TWO PANELS. THE PLAN
 INDICATES A METER AND THREE PANELS,
 PLEASE CORRELATE.
  
 2} PANELS #2 & 3 ARE SHOWN AS MLO.
 CONDUCTORS ENERING SEPARATE STRUCTURES
 MUST HAVE A DISCONNECTING MEANS PER
 225.31 AN BE GROUNDED PER 250.32. THE
 RISER AN DPANEL SCHEDULE ARE NOT IN
 COMPLIANCE.
  
 3} THE 1/0 SERVICE CONDUCTORSINDICATED
 ON THE RISER TO FPL ARE TOO SMALL FOR A
 400 AMP SERVICE PER 310.15(B)(6).
  
 4} THE PANEL MARKED #1 HAS CIRCUITS
 1'3'5'AND 7 ON A COMMON TRIP BREAKER
 WITH ONLY ONE 10K LOAD INDICATED FOR TWO
 AHU'S.
  
 5} CIRCUITS 2&4, PANEL #1 SHOWS #14 WIRE
 ON A 50 AMP BREAKER. SEE 310.16.
  
 6} THE MINIMUM GROUNDING ELECTRODE
 CONDUCTOR FOR A 400 AMP SERVICE IS 1/0
 CU PER 250.66. SEE RISER.
  
 7} THE ELEVATOR SHOWN ON THE PLAN IS NOT
 IN THE LOAD CALCULATION OR ON A PANEL
 SCHEDULE . PLEASE INDICATE ALL EQUIPMENT
 ON THE PLAN.
  
 8} THE ROOMS ON THE FIRST AND SECOND
 FLOOR, EXCEPT THE BATHS AND SITTING
 ROOM, ALL NEED RECEPTACLES ADDED TO
 COMPLY WITH THE SPACING REQUIREMENTS OF
 210.52(A)(1)&(2). SEE REVIEWED PLAN FOR
 SOME REDLINED AREAS.
  
 9} THE ATTIC AREA USED AS MECHANICAL
 SPACE MUST HAVE LIGHT PER 210.70(A)(3)
 AND RECEPTACLES PER 210.63.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  
  
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 20 Status N Date 2008-03-31 Cont ID  
Sent By adarroug Date 2008-03-31 Time 09:53 Rev Time 0.00
Received By adarroug Date 2008-03-31 Time 09:53 Sent To M
Notes
2008-03-31 09:55:01TO "M" BOX/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 19 Status N Date 2008-03-13 Cont ID  
Sent By adarroug Date 2008-03-13 Time 14:04 Rev Time 0.00
Received By adarroug Date 2008-03-13 Time 14:04 Sent To M
Notes
2008-03-13 14:05:15TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 18 Status N Date 2007-12-06 Cont ID  
Sent By adarroug Date 2007-12-06 Time 10:15 Rev Time 0.00
Received By adarroug Date 2007-12-06 Time 10:15 Sent To B
Notes
2007-12-06 10:16:15TO "LMARTINEZ" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 17 Status N Date 2007-11-19 Cont ID  
Sent By adarroug Date 2007-11-19 Time 08:50 Rev Time 0.00
Received By adarroug Date 2007-11-19 Time 08:50 Sent To E
Notes
2007-11-19 08:50:41TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 16 Status N Date 2007-10-16 Cont ID  
Sent By adarroug Date 2007-10-16 Time 09:30 Rev Time 0.00
Received By adarroug Date 2007-10-16 Time 09:30 Sent To E
Notes
2007-10-16 09:30:28TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 15 Status N Date 2007-08-30 Cont ID  
Sent By adarroug Date 2007-08-30 Time 16:08 Rev Time 0.00
Received By adarroug Date 2007-08-30 Time 16:08 Sent To M
Notes
2007-08-30 16:08:16TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 14 Status N Date 2007-08-03 Cont ID  
Sent By adarroug Date 2007-08-03 Time 09:46 Rev Time 0.00
Received By adarroug Date 2007-08-03 Time 09:45 Sent To M
Notes
2007-08-03 09:46:22TO "TGORDON" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 13 Status N Date 2007-07-24 Cont ID  
Sent By adarroug Date 2007-07-24 Time 09:16 Rev Time 0.00
Received By adarroug Date 2007-07-24 Time 09:16 Sent To M
Notes
2007-07-24 09:17:12TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 12 Status N Date 2007-03-13 Cont ID  
Sent By adarroug Date 2007-03-13 Time 15:30 Rev Time 0.00
Received By adarroug Date 2007-03-13 Time 15:30 Sent To E
Notes
2007-03-13 15:31:08TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 11 Status N Date 2006-08-07 Cont ID  
Sent By adarroug Date 2006-08-07 Time 17:00 Rev Time 0.00
Received By adarroug Date 2006-08-07 Time 17:00 Sent To Z
Notes
2006-08-07 00:00:00TO "Z" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 10 Status N Date 2006-07-18 Cont ID  
Sent By adarroug Date 2006-07-18 Time 13:45 Rev Time 0.00
Received By adarroug Date 2006-07-18 Time 13:45 Sent To B
Notes
2006-07-18 00:00:00TO "ALANGE" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2006-07-10 Cont ID  
Sent By adarroug Date 2006-07-10 Time 09:21 Rev Time 0.00
Received By adarroug Date 2006-07-10 Time 09:20 Sent To Z
Notes
2006-07-10 00:00:00TO "Z" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2006-06-27 Cont ID  
Sent By adarroug Date 2006-06-27 Time 09:45 Rev Time 0.00
Received By adarroug Date 2006-06-27 Time 09:45 Sent To E
Notes
2006-06-27 00:00:00TO "E" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2006-06-22 Cont ID  
Sent By adarroug Date 2006-06-22 Time 10:25 Rev Time 0.00
Received By adarroug Date 2006-06-22 Time 10:25 Sent To B
Notes
2006-06-22 00:00:00TO "ALANGE" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2006-06-22 Cont ID  
Sent By adarroug Date 2006-06-22 Time 10:10 Rev Time 0.00
Received By adarroug Date 2006-06-22 Time 10:10 Sent To Z
Notes
2006-06-22 00:00:00TO "Z" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-06-07 Cont ID  
Sent By adarroug Date 2006-06-07 Time 18:18 Rev Time 0.00
Received By adarroug Date 2006-06-07 Time 18:18 Sent To E
Notes
2006-06-07 00:00:00TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-05-18 Cont ID  
Sent By adarroug Date 2006-05-18 Time 10:25 Rev Time 0.00
Received By adarroug Date 2006-05-18 Time 10:24 Sent To M
Notes
2006-05-18 00:00:00TO "M" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-04-27 Cont ID  
Sent By adarroug Date 2006-04-27 Time 09:10 Rev Time 0.00
Received By adarroug Date 2006-04-27 Time 09:10 Sent To E
Notes
2006-04-27 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-04-21 Cont ID  
Sent By adarroug Date 2006-04-21 Time 11:35 Rev Time 0.00
Received By adarroug Date 2006-04-21 Time 11:35 Sent To Z
Notes
2006-04-21 00:00:00TO "Z" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-04-06 Cont ID  
Sent By alange Date 2006-04-06 Time 09:04 Rev Time 0.00
Received By alange Date 2006-03-06 Time 16:20 Sent To  
Notes
2006-03-06 00:00:00TO "SFR" "Z"

Review Stop M MECHANICAL (A/C)
Rev No 9 Status P Date 2008-04-01 Cont ID  
Sent By tgordon Date 2008-04-01 Time 09:50 Rev Time 0.30
Received By tgordon Date 2008-04-01 Time 09:50 Sent To  
Notes
2008-04-01 09:52:11REVISION TO A/C EQUIPMENT SCHEDULE.

Review Stop M MECHANICAL (A/C)
Rev No 8 Status F Date 2008-03-14 Cont ID  
Sent By tgordon Date 2008-03-14 Time 10:49 Rev Time 0.30
Received By tgordon Date 2008-03-14 Time 10:49 Sent To  
Notes
2008-03-14 10:54:04PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM
 BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 REVISION TO MECHANICAL PLANS
 *** DENIED ***
 1) MECHANICAL PLANS ON FILE ARE SIGNED AND SEALED BY AN
 ARCHITECT (JAMES C. PAINE) SO ONLY HE CAN MAKE
 REVISIONS TO THEM. PLEASE HAVE HIM SIGN AND SEAL THE
 REVISION OR SUBMIT A LETTER REMOVING HIMSELF FROM THE
 PROJECT.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 7 Status P Date 2007-09-04 Cont ID  
Sent By tgordon Date 2007-09-04 Time 10:10 Rev Time 0.25
Received By tgordon Date 2007-09-04 Time 10:10 Sent To  
Notes
2007-09-04 10:10:55REVISION TO MECH. PLAN PAGE M-1.

Review Stop M MECHANICAL (A/C)
Rev No 6 Status P Date 2007-08-06 Cont ID  
Sent By tgordon Date 2007-08-06 Time 16:15 Rev Time 0.15
Received By tgordon Date 2007-08-06 Time 16:15 Sent To  
Notes
2007-08-06 16:18:02MECH. REVISION TO PAGE M-2 HAS BEEN APPROVED, REVISION
 TO PAGE M-1 HAS BEEN DENIED DUE TO DRYER VENT CAP.

Review Stop M MECHANICAL (A/C)
Rev No 5 Status F Date 2007-08-06 Cont ID  
Sent By tgordon Date 2007-08-06 Time 15:40 Rev Time 0.30
Received By tgordon Date 2007-08-06 Time 15:40 Sent To  
Notes
2007-08-06 15:59:10** MECHANICAL REVISION **
 *** DENIED ***
 1) THE DEFLECT-O ADJUSTABLE DIFFUSER SUBMITTED IS NOT
 STATE THAT IT IS DESIGNED TO BE A CLOTHES DRYER VENT
 CAP, PLEASE SUBMIT THE CLOTHES DRYER MANUFACTURER'S
 INSTALLATION INSTRUCTIONS SHOWING THAT THIS TYPE OF CAP
 MAY BE USED ON THEIR DRYER EXHAUST, AND INFORMATION
 FROM DEFLECT-O SHOWING THAT IT IS UL APPROVED AS A
 CLOTHES DRYER VENT CAP, SEE 2004 FBC M1501.1.
  
 **2004 FBC/R M1501.1 GENERAL.
 DRYER EXHAUST SYSTEMS SHALL BE INDEPENDENT OF ALL OTHER
 SYSTEMS, SHALL CONVEY THE MOISTURE TO THE OUTDOORS AND
 SHALL TERMINATE ON THE OUTSIDE OF THE BUILDING. EXHAUST
 DUCT TERMINATIONS SHALL BE IN ACCORDANCE WITH THE DRYER
 MANUFACTURER'S INSTALLATION INSTRUCTIONS. SCREENS SHALL
 NOT BE INSTALLED AT THE DUCT TERMINATION. EXHAUST DUCTS
 SHALL NOT BE CONNECTED WITH SHEET-METAL SCREWS OR
 FASTENING MEANS WHICH EXTEND INTO THE DUCT. EXHAUST
 DUCTS SHALL BE EQUIPPED WITH A BACKDRAFT DAMPER.
 EXHAUST DUCTS SHALL BE CONSTRUCTED OF MINIMUM
 0.016-INCH-THICK (0.406 MM) RIGID METAL DUCTS, HAVING
 SMOOTH INTERIOR SURFACES WITH JOINTS RUNNING IN THE
 DIRECTION OF AIR FLOW. FLEXIBLE TRANSITION DUCTS USED
 TO CONNECT THE DRYER TO THE EXHAUST DUCT SYSTEM SHALL
 BE LIMITED TO SINGLE LENGTHS, NOT TO EXCEED 8 FEET
 (2438 MM) IN LENGTH AND SHALL BE LISTED AND LABELED IN
 ACCORDANCE WITH UL 2158A. TRANSITION DUCTS SHALL NOT BE
 CONCEALED WITHIN CONSTRUCTION.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 4 Status F Date 2007-07-25 Cont ID  
Sent By tgordon Date 2007-07-25 Time 08:03 Rev Time 0.30
Received By tgordon Date 2007-07-25 Time 08:03 Sent To  
Notes
2007-07-25 08:34:34** MECHANICAL REVISION **
 *** DENIED ***
 1) PLANS PAGE M-1 SHOWS THE RANGE HOOD VENT AND THE
 CLOTHES DRYER VENT TERMINATING AT THE SOFFIT, PLEASE
 SHOW A DETAIL HOW THIS IS BEING INSTALLED AND SUBMIT A
 MANUFACTURERS SPECIFICATION SHEET FOR THE END CAP THAT
 IS BEING USED, SEE 2004 FBC/R M1501.1 SCREENS SHALL NOT
 BE INSTALLED AT DUCT TERMINATION AND SHALL BE EQUIPPED
 WITH A BACKDRAFT DAMPER.
  
 2) SEE YELLOW HIGH LIGHTS ON PLANS PAGE M-2 SHOWING
 RETURN AIR DUCTS THAT NEED TO BE SIZED.
  
 3) PAGE M-2 SHOWS ONLY ONE 8" RETURN AIR DUCT TO AHU-1
 AND ONE 10" RETURN AIR DUCT TO AHU-2 IF THIS IS THE
 ONLY MEANS OF RETURN TO THE AIR HANDLERS THAT WOULD PUT
 THEM AT A VELOCITY OF 4000 AND 2600, IF THIS IS THE
 CASE PLEASE SUBMIT MANUAL D CALCULATIONS, DETAILED
 MANUFACTURER'S SPECIFICATION'S FOR THE AIR HANDLER WITH
 COOLING COIL, AND FLEX DUCTS.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2006-05-18 Cont ID  
Sent By tgordon Date 2006-05-18 Time 15:38 Rev Time 0.45
Received By tgordon Date 2006-05-18 Time 15:38 Sent To P
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2006-05-01 Cont ID  
Sent By tgordon Date 2006-05-01 Time 09:00 Rev Time 0.45
Received By tgordon Date 2006-05-01 Time 09:00 Sent To P
Notes
2006-05-01 00:00:00*** DENIED ***
 1) RETURN AIR TRANSFER DUCT TO MASTER
 SUITE IS TO SMALL, SEE NOTE #3(C)
 EXCEPT.
  
 2) RETURN AIR TRANSFER DUCTS TO DINING
 ROOM AND OFFICE NEED TO BE SIZED.
  
 3)BALANCED RETURN AIR.
 THIS MAY BE ACHIEVED BY.
 (A)TRANSFER DUCTS MAY ACHIEVE THIS BY
 INCREASING THE RETURN TRANSFER ONE AND
 ONE HALF TIMES THE CROSS SECTIONAL AREA
 (SQUARE INCHES) OF THE SUPPLY DUCT
 ENTERING THE ROOM OR SPACE IT'S SERVING
 AND THE DOOR HAVING AT LEAST AN
 UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE
 PROPER RETURN AIR BALANCE.
 (B)TRANSFER GRILLES SHALL USE 50
 SQUARE INCHES (OF GRILLE AREA) TO 100
 CFM (OF SUPPLY AIR) FOR SIZING
 THROUGH-THE-WALL TRANSFER GRILLES AND
 USING AN UNRESTRICTED 1-INCH
 UNDERCUTTING OF DOORS TO ACHIEVE PROPER
 RETURN AIR BALANCE
 (C)HABITABLE ROOMS ONLY SHALL BE
 REQUIRED TO MEET THESE REQUIREMENTS FOR
 PROPER BALANCED RETURN AIR EXCLUDING
 BATHROOMS, CLOSETS, STORAGE ROOMS AND
 LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY
 AIR INTO THE MASTER SUITE SHALL BE
 INCLUDED. PER 2004 FBC/R M1602.4 .
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2006-03-08 Cont ID  
Sent By tgordon Date 2006-03-08 Time 15:47 Rev Time 0.40
Received By tgordon Date 2006-03-08 Time 15:47 Sent To Z
Notes
2006-03-08 00:00:00*** DENIED ***
 1) ENERGY CALCULATIONS ARE CALLING FOR
 84,000 TOTAL BTU'S, MECHANICAL PLANS ARE
 CALLING FOR 90,000 TOTAL BTU'S. THE
 PLANS CAN NOT CALL FOR MORE THAN THE
 ENERGY CAL'S, PLEASE CORRECT.
  
 2) THE MANUAL J IS CALLING FOR A TOTAL
 SENSIBLE BTU'S OF 56,203 AND THE MECH.
 PLANS ARE CALLING FOR A TOTAL SENSIBLE
 BTU'S OF 68,800. THE PLANS CAN ONLY CALL
 FOR 20% MORE THAN THE MANUAL J, PER 2004
 FBC 13-607.1.ABC.1.1 .PLEASE CORRECT.
  
 3) PLEASE SUBMIT MANUAL J (LONG FORM)
 SHOWING DUCT SIZES AND CFM'S FOR EACH
 ROOM. AS MECH. PLAN DUCT (FLEX) SIZES
 AND CFM'S SHOWING WILL CAUSE TO LOW AN
 AIR VELOCITY.
  
 4) PROVIDE RETURN AIR FOR THE OFFICE AND
 LIVING ROOM, SEE NOTE #6.
  
 5) TRANSFER RETURN AIR DUCTS (FLEX) ON
 SECOND FLOOR, NEED TO SHOW SIZES, SEE
 NOTE #6.
  
 6) BALANCED RETURN AIR.
 THIS MAY BE ACHIEVED BY.
 (A)TRANSFER DUCTS MAY ACHIEVE THIS BY
 INCREASING THE RETURN TRANSFER ONE AND
 ONE HALF TIMES THE CROSS SECTIONAL AREA
 (SQUARE INCHES) OF THE SUPPLY DUCT
 ENTERING THE ROOM OR SPACE IT'S SERVING
 AND THE DOOR HAVING AT LEAST AN
 UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE
 PROPER RETURN AIR BALANCE.
 (B)TRANSFER GRILLES SHALL USE 50
 SQUARE INCHES (OF GRILLE AREA) TO 100
 CFM (OF SUPPLY AIR) FOR SIZING
 THROUGH-THE-WALL TRANSFER GRILLES AND
 USING AN UNRESTRICTED 1-INCH
 UNDERCUTTING OF DOORS TO ACHIEVE PROPER
 RETURN AIR BALANCE
 (C)HABITABLE ROOMS ONLY SHALL BE
 REQUIRED TO MEET THESE REQUIREMENTS FOR
 PROPER BALANCED RETURN AIR EXCLUDING
 BATHROOMS, CLOSETS, STORAGE ROOMS AND
 LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY
 AIR INTO THE MASTER SUITE SHALL BE
 INCLUDED. PER 2004 FBC/R M1602.4 .
  
 7) PLEASE SHOW LOCATION AND SIZES OF
 MAIN RETURN AIR GRILLS TO AIR HANDLERS.
  
 8) PLEASE SHOW LOCATION OF DRYER VENT ON
 MECH. PLANS.
  
 9) PLEASE SUBMIT DETAILED MANUFACTURE'S
 SPECIFICATION'S AND INSTALLATION
 INSTRUCTIONS FOR GAS FIRE PLACE.
  
 10) PLEASE PROVIDE COMBUSTION AIR
 CALCULATIONS ON MECHANICAL PLANS, FOR
 GAS FIRE PLACE.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.
  
  
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2006-05-05 Cont ID  
Sent By jleech Date 2006-05-05 Time 09:36 Rev Time 0.00
Received By jleech Date 2006-05-05 Time 09:36 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2006-03-24 Cont ID  
Sent By jleech Date 2006-03-24 Time 09:56 Rev Time 0.75
Received By jleech Date 2006-03-24 Time 09:56 Sent To Z
Notes
2006-03-24 00:00:00DENIED;
 RISER DIAGRAM NOT TO CODE;
 FIRST FLOOR
 1.1/2 BATH TOILET NOT VENTED. FBC-2004
 PLUMBING SEC.909.1.
 2.AUTOMATIC CLOTHES WASHER AND LAUNDRY
 TUB NOT VENTED. CLEANOT REQUIRED ON
 WASHER AT 48" AFF.
 3.AUTOMATIC CLOTHES WASHER DRAIN TO BE
 3" SEE SEC. 406.3.
 SECOND FLOOR
 1.TUB NOT VENTED.
 2.BIDET NOT VENTED
 3.URINAL NOT VENTED.
 4.AUTOMATIC CLOTHES WASHER DRAIN TO BE
 3" SEC.406.3
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop Z ZONING
Rev No 3 Status F Date 2006-06-25 Cont ID  
Sent By mmclean Date 2006-06-25 Time 15:19 Rev Time 0.00
Received By mmclean Date 2006-06-25 Time 15:19 Sent To I
Notes
2006-06-25 00:00:00DENIED,
 1. MUST PULL A SEPERATE PERMIT FOR WALL
 WITH UTILITY EASEMENT APPROVAL FROM THE
 CITY OF WEST PALM BEACH UTILITY DEPT.
 (AS MENTION IN REVIEW 3/27/06)
 2. PLEASE PROVIDE A COPY OF CURRENT
 SURVEY WITHE THE SITEPLAN SHOWING THE
 LOCATION OF THE PROPOSED WALL/COLUMNS
  
 NOTE: THE MAXIMUM HEIGHT ALLOWED WITHIN
 THE FIRST 25FT FRONT SETBACK IS 4FT
 ONLY. BEYOND THE 25FT FRONT SETBACK THE
 MAXIMUM HEIGHT ALLOWED IS 6FT ONLY.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720

Review Stop Z ZONING
Rev No 2 Status P Date 2006-04-26 Cont ID  
Sent By mmclean Date 2006-04-26 Time 15:53 Rev Time 0.00
Received By mmclean Date 2006-04-26 Time 15:53 Sent To I
Notes
2006-04-26 00:00:00LETTER ATTACHED FOR THE 15FT ALLEY
 ABANDONED BY THE CITY. RES #72-73

Review Stop Z ZONING
Rev No 1 Status F Date 2006-03-27 Cont ID  
Sent By mmclean Date 2006-03-27 Time 08:16 Rev Time 0.00
Received By mmclean Date 2006-03-27 Time 08:16 Sent To B
Notes
2006-03-27 00:00:00DENIED,
 1. MUST PROVIDED PROOF OF THE 15FT ALLEY
 BEING ABANDONED (BY THE CITY -
 ENGINEERING DEPT).
  
  
 NOTE: MUST PULL A SEPERATE PERMIT FOR
 POOL/SPA/DECK/SCREEN ENCLOSURE.
 NOTE: MUST PULL A SEPERATE PERMIT FOR
 FENCE/WALL/GATE WITH EASEMENT APPROVAL
 FROM CITY OF WEST PALM BEACH UTILITY
 DEPT.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720


Account Summary | Usage Policy | Privacy Policy