Plan Review Details - Permit 06030093
Plan Review Stops For Permit 06030093
Review Stop AD ADDRESSING
Rev No 1 Status N Date 2006-06-07 Cont ID  
Sent By btrobaug Date 2006-06-07 Time 07:27 Rev Time 0.00
Received By btrobaug Date 2006-06-07 Time 07:27 Sent To  
Notes
2006-03-02 00:00:00PLEASE CHANGE OWNER INFO PER ATTACHED
 PAPERWORK

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2006-05-15 Cont ID  
Sent By amorse Date 2006-05-15 Time 15:28 Rev Time 0.50
Received By amorse Date 2006-05-15 Time 15:28 Sent To M
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2006-04-05 Cont ID  
Sent By amorse Date 2006-04-05 Time 06:55 Rev Time 0.50
Received By amorse Date 2006-04-05 Time 06:55 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 6 Status P Date 2007-04-27 Cont ID  
Sent By btrobaug Date 2007-04-27 Time 11:06 Rev Time 0.50
Received By btrobaug Date 2007-04-27 Time 11:06 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2006-11-01 Cont ID  
Sent By btrobaug Date 2006-11-01 Time 07:45 Rev Time 0.50
Received By btrobaug Date 2006-11-01 Time 06:51 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2006-10-23 Cont ID  
Sent By btrobaug Date 2006-10-05 Time 08:07 Rev Time 0.50
Received By btrobaug Date 2006-10-05 Time 07:13 Sent To P
Notes
2006-10-05 00:00:00 
  
 NONCOMPLIANT
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} THE ENGINEER OF RECORD MUST MAKE
 CHANGES/REVISIONS TO HIS/HER DESIGN. SEE
 CHAPTER 471 FLORIDA STATUTES.
  
 2} WHEN MAKING REVISIONS, USE THE SAME
 PAGE NUMBER AS THE SHEET ORIGINALLY
 PERMITED, FOR CHANGES AFFECTING THAT
 SHEET.
  
 3} REVISE SHEETS WITH THE SAME SIZE
 SHEETS AS ORIGINALLY PERMITTED FOR THE
 SAKE OF CONSISTENCY IN RECORD RETENTION
 AND GOOD DRAFTING PRACTICE. 106.1.3 FBC
 AS AMENDED.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-06-07 Cont ID  
Sent By btrobaug Date 2006-06-07 Time 07:26 Rev Time 1.00
Received By btrobaug Date 2006-06-07 Time 06:28 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2006-05-04 Cont ID  
Sent By btrobaug Date 2006-05-04 Time 07:38 Rev Time 1.00
Received By btrobaug Date 2006-05-04 Time 06:32 Sent To P
Notes
2006-05-04 00:00:00 
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} THE NOTE NOW APPEARING ON THE RISER
 REGARDING CONDUIT TO THE "MAIN BUILDING"
 INDICATES THAT THE SERVICE IS ON A
 SEPARATE STRUCTURE FROM THE MAIN HOUSE.
 PLEASE SHOW THE LOCATION OF ALL SERVICE
 EQUIPMENT SO THAT COMPLIANCE WITH
 ARTICLES 225, 250, AND 230 CAN BE
 REVIEWED. INDICATE CORRECT DISCONNECTING
 MEANS, GROUNDING AND GROUPING OF MAINS
 AND DISCONNECTING MEANS.
  
 2} THE #1 FEEDERS TO THE 150 AMP
 SUB-PANEL HAVE A 200 AMP OVERCURRENT
 PROTECTION, AND MUST BE INCREASED TO A
 MINIMUM OF 2/0CU PER 310.15.
  
 3} INDICATE THE ACTUAL SIZE OF THE
 GROUNDING ELECTRODE CONDUCTOR FOR THE
 SERVICE , NOT THE NUMBER OF THE ARTICLE
 REQUIRING IT.
  
 4} A SMOKE DETECTOR IS REQUIRED ON THE
 FIRST LEVEL AT THE STAIRS PER R313
 .1.1 FBC.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-03-14 Cont ID  
Sent By btrobaug Date 2006-03-14 Time 15:59 Rev Time 0.75
Received By btrobaug Date 2006-03-14 Time 15:27 Sent To P
Notes
2006-03-14 00:00:00 
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} PROVIDE AIC RATINGS FOR THE SERVICE
 EQUIPMENT PER 110.9 AND 110.10.
  
 2} PLEASE PROVIDE A PANEL SCHEDULE FOR
 THE NEW PANEL SO THAT BRANCH CIRCUIT
 COMPLIANCE MAY BE REVIEWED.
  
 3} THE 1/0 CU ON THE RISER IS INCORRECT.
 TO THE PANEL 2/0 MINIMUM IS REQUIRED PER
 310.15(B).
  
 4} THE NOTE REGARDING GROUNDING
 (250.83C) SHOULD READ 250.50, THE
 CURRENT 2002 CODE SECTION.
  
 5} THE KITCHEN COUNTERTOP RECEPTACLES
 MUST BE SPACED PER 210.52(C).
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  
  
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2007-04-17 Cont ID  
Sent By adarroug Date 2007-04-17 Time 11:33 Rev Time 0.00
Received By adarroug Date 2007-04-17 Time 11:33 Sent To E
Notes
2007-04-17 11:34:07TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2006-10-26 Cont ID  
Sent By adarroug Date 2006-10-26 Time 13:47 Rev Time 0.00
Received By adarroug Date 2006-10-26 Time 13:47 Sent To E
Notes
2006-10-26 13:47:20TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-10-02 Cont ID  
Sent By adarroug Date 2006-10-02 Time 12:42 Rev Time 0.00
Received By adarroug Date 2006-10-02 Time 12:42 Sent To E
Notes
2006-10-02 00:00:00TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-05-24 Cont ID  
Sent By adarroug Date 2006-05-24 Time 18:36 Rev Time 0.00
Received By adarroug Date 2006-05-24 Time 18:36 Sent To E
Notes
2006-05-24 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-05-02 Cont ID  
Sent By adarroug Date 2006-05-02 Time 14:47 Rev Time 0.00
Received By adarroug Date 2006-05-02 Time 14:47 Sent To E
Notes
2006-05-02 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-03-09 Cont ID  
Sent By adarroug Date 2006-03-09 Time 11:40 Rev Time 0.00
Received By adarroug Date 2006-03-09 Time 11:40 Sent To E
Notes
2006-03-09 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By mmclean Date 2006-04-05 Time 17:05 Rev Time 0.00
Received By adarroug Date 2006-03-03 Time 12:47 Sent To  
Notes
2006-03-03 00:00:00TO "Z" BOX--NEW KITCHEN

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2006-05-15 Cont ID  
Sent By tgordon Date 2006-05-15 Time 15:45 Rev Time 0.10
Received By tgordon Date 2006-05-15 Time 15:45 Sent To  
Notes
2006-05-15 00:00:00NO MECHANICAL PLANS SUBMITTED, AND NO
 MECHANICAL PERMIT NUMBER APPLIED FOR AT
 THIS TIME. MECH. PERMIT # 06030095 HAS
 BEN VOIDED.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2006-03-20 Cont ID  
Sent By tgordon Date 2006-03-20 Time 14:10 Rev Time 0.20
Received By tgordon Date 2006-03-20 Time 14:10 Sent To B
Notes
2006-03-20 00:00:00*** DENIED ***
 1) NO MECHANICAL PLANS WERE SUBMITTED
 FOR REVIEW. PLEASE SUBMIT MECHANICAL
 PLANS FOR REVIEW, OR YOU MAY WISH TO
 VOID YOUR MECHANICAL PERMIT NUMBER
 06030095 SO YOUR BUILDING PLANS MAY
 BY-PASS A MECHANICAL REVIEW.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.
  

Review Stop P PLUMBING
Rev No 4 Status P Date 2006-11-02 Cont ID  
Sent By jleech Date 2006-11-02 Time 07:17 Rev Time 0.00
Received By jleech Date 2006-11-02 Time 07:17 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2006-10-21 Cont ID  
Sent By btrobaug Date 2006-10-23 Time 15:15 Rev Time 0.00
Received By jleech Date 2006-10-21 Time 13:17 Sent To M
Notes
2006-10-21 13:20:02DENIED;
 SEE ELECTRICAL NOTES. PLANS NOTE SEALED ETC.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop P PLUMBING
Rev No 2 Status P Date 2006-05-15 Cont ID  
Sent By jleech Date 2006-05-15 Time 13:17 Rev Time 0.00
Received By jleech Date 2006-05-15 Time 13:17 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2006-03-20 Cont ID  
Sent By jleech Date 2006-03-20 Time 10:08 Rev Time 0.00
Received By jleech Date 2006-03-20 Time 10:08 Sent To M
Notes
2006-03-20 00:00:00DENIED;
 SHOW SANITARY RISER DIAGRAM FOR LAUNDRY
 ROOM. TRAP PRIMER REQUIRED IN FLOOR
 DRAIN TO PREVENT TRAP FROM DRYING OUT.
 HORIZONTAL DRY VENTS ARE NOT PERMITED,
 W/C JACK AND GILL BATHROOM.FBC-2004
 SEC.905.3
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop Z ZONING
Rev No 1 Status N Date 2006-03-08 Cont ID  
Sent By mmclean Date 2006-03-08 Time 17:05 Rev Time 0.00
Received By mmclean Date 2006-03-08 Time 17:05 Sent To I
Notes
2006-03-08 00:00:00NO CHANGE IN FOOTPRINT OF EXISTING
 STRUCTURTE.