| Plan Review Stops For Permit 06030074 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2006-09-27 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-09-15 |
Time |
15:02 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2006-09-15 |
Time |
14:05 |
Sent To |
|
|
| Notes |
| 2006-09-27 00:00:00 | | | | | | | ACCIDENTALY ENTERED ADDRESSING REVIEW | | | ADRIAN |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2006-09-27 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2006-09-27 |
Time |
14:10 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2006-09-27 |
Time |
14:10 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2006-08-05 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-08-05 |
Time |
15:04 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2006-08-05 |
Time |
11:59 |
Sent To |
PC |
|
| Notes |
| 2006-08-05 00:00:00 | | | | | | | DENIED | | | | | | 1) AN ENGINEER PRACTICING THROUGH A DULY | | | AUTHORIZED ENGINEERING BUSINESS SHALL | | | INDICATE THEIR NAME AND LICENCE #, AS | | | WELL AS THE NAME,ADDRESS AND CERTIFICATE | | | OF AUTHORIZATION #ON EACH SHEET PER | | | 61G15-23.002(2) FAC | | | | | | 2) PER 713.13(2) F.S. IF THE IMPROVEMENT | | | DESCRIBED IN THE NOC HAS NOT COMMENCED | | | WITHIN 90 DAYS OF RECORDING THE NOTICE | | | IS VOID | | | | | | 3) NO WHITE OUT PERMITTED ON DRAWINGS | | | PLEASE CORRECT | | | | | | 4) SUB TRADES ON APPLICATION BUT NO | | | LICENCE NUMBERS OR PERMIT NUMBERS | | | GENERATED PLEASE CORRECT | | | | | | 5) EXISTING GARAGE DOOR ON ELECTRICAL | | | SHOWS GFI MOUNTED ON IT PLEASE CLARIFY | | | | | | 6)THE PERMIT APPLICATION SHALL INCLUDE | | | TWO COPIES OF EACH PRODUCT APPROVAL THAT | | | IS RELEVANT PER 9B-72. THESE SHOULD | | | INCLUDE THE FLORIDA STATE APPROVAL COVER | | | PAGES, AND THE PRODUCT NOA THAT LISTS | | | THE SYSTEM COMPONENTS/ FASTENER LIST | | | PAGES, THE PAGES WITH THE CHOSEN | | | ASSEMBLY/ SYSTEM TO BE USED AND THE | | | GENERAL LIMITATIONS PAGE. ALL CAN BE | | | FOUND ON WWW.FLORIDABUILDING.ORG | | | (9B-72 INCLUDES ALL EXTERIOR COMPONENTS | | | SUCH AS WINDOWS, DOORS, MULLIONS, ETC.) | | | *************************************** | | | 1)PROVIDE FLORIDA COVER SHEETS FOR TRACO | | | WINDOWS FL# 6585 AND NEW UPDATED NOA# | | | 05-0729.03 | | | 2) THURMA-TRU COVER IS CORRECT BUT NO | | | DRAWINGS WERE SUBMITTED PLEASE SEE PAGE | | | 2 OF THE COVER SHEET TO PRINT OUT THE | | | APPLICABLE DRAWING | | | 3) PROVIDE COVER SHEETS FOR ARMOR | | | SCREEN, FL# 320 | | | | | | 7) SUBMIT PROOF OF OWNERSHIP OR CHANGE | | | OWNER INFORMATION ON APPLICATION | | | *****PROPERTY APPRAISER HAS RUTH AND | | | FREEMAN L REAMES AS OWNER APPLICATION | | | HAS DANIEL PLEASE CORRECT*** | | | | | | 8) PROPERTY HAS HISTORIC DESIGNATION AND | | | REQUIRES HISTORIC APPROVAL AND STAMP | | | | | | ADRIAN MORSE | | | BLDG PLAN REVIEW | | | 561-805-6716 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-06-08 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2006-06-08 |
Time |
09:02 |
Rev Time |
0.50 |
| Received By |
amorse |
Date |
2006-06-08 |
Time |
09:02 |
Sent To |
PC |
|
| Notes |
| 2006-06-08 00:00:00 | | | | | | | DENIED | | | | | | REQUESTED INFORMATION NOT SUBMITTED FROM | | | FIRST REVIEW | | | | | | | | | 1) PROVIDE PREVIOUS LAYOUT OR DEMOLITION | | | PLAN | | | | | | 2) PROVIDE COMPLETE DRAWINGS FOR REVIEW | | | TO INCLUDE WORK BY ALL TRADES, ALSO | | | STRUCTURAL WORK FOR CLOSE IN OF GARAGE | | | DOOR | | | | | | 3) THE PERMIT APPLICATION SHALL INCLUDE | | | TWO COPIES OF EACH PRODUCT APPROVAL THAT | | | IS RELEVANT PER 9B-72. THESE SHOULD | | | INCLUDE THE FLORIDA STATE APPROVAL COVER | | | PAGES, AND THE PRODUCT NOA THAT LISTS | | | THE SYSTEM COMPONENTS/ FASTENER LIST | | | PAGES, THE PAGES WITH THE CHOSEN | | | ASSEMBLY/ SYSTEM TO BE USED AND THE | | | GENERAL LIMITATIONS PAGE. ALL CAN BE | | | FOUND ON WWW.FLORIDABUILDING.ORG | | | (9B-72 INCLUDES ALL EXTERIOR COMPONENTS | | | SUCH AS WINDOWS, DOORS, MULLIONS, ETC.) | | | | | | 4) SUBMIT PROOF OF OWNERSHIP OR CHANGE | | | OWNER INFORMATION ON APPLICATION | | | | | | 5) A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT IS REQUIRED PRIOR TO | | | A PERMIT BEING ISSUED | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-04-05 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2006-04-05 |
Time |
07:09 |
Rev Time |
0.50 |
| Received By |
amorse |
Date |
2006-04-05 |
Time |
07:09 |
Sent To |
PC |
|
| Notes |
| 2006-04-05 00:00:00 | | | | | | | DENIED | | | | | | 1) PROVIDE PREVIOUS LAYOUT OR DEMOLITION | | | PLAN | | | | | | 2) PROVIDE COMPLETE DRAWINGS FOR REVIEW | | | TO INCLUDE WORK BY ALL TRADES, ALSO | | | STRUCTURAL WORK FOR CLOSE IN OF GARAGE | | | DOOR | | | | | | 3) THE PERMIT APPLICATION SHALL INCLUDE | | | TWO COPIES OF EACH PRODUCT APPROVAL THAT | | | IS RELEVANT PER 9B-72. THESE SHOULD | | | INCLUDE THE FLORIDA STATE APPROVAL COVER | | | PAGES, AND THE PRODUCT NOA THAT LISTS | | | THE SYSTEM COMPONENTS/ FASTENER LIST | | | PAGES, THE PAGES WITH THE CHOSEN | | | ASSEMBLY/ SYSTEM TO BE USED AND THE | | | GENERAL LIMITATIONS PAGE. ALL CAN BE | | | FOUND ON WWW.FLORIDABUILDING.ORG | | | (9B-72 INCLUDES ALL EXTERIOR COMPONENTS | | | SUCH AS WINDOWS, DOORS, ETC.) | | | | | | 4) SUBMIT PROOF OF OWNERSHIP OR CHANGE | | | OWNER INFORMATION ON APPLICATION | | | | | | 5) A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT IS REQUIRED PRIOR TO | | | A PERMIT BEING ISSUED | | | | | | | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2006-09-15 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-09-15 |
Time |
14:20 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-09-15 |
Time |
14:09 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2006-08-02 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-08-02 |
Time |
16:01 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-08-02 |
Time |
14:33 |
Sent To |
P |
|
| Notes |
| 2006-08-02 00:00:00 | | | | NONCOMPLIANT | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} THE GARAGE RECEPTACLES MUST COMPLY | | | WITH 210.8(A)(2). | | | | | | 2} THE ENGINEER OF RECORD SHALL INDICATE | | | THE CERTIFICATE OF AUTHORIZATIONNUMBER | | | ALONG WITH OTHER INFORMATION REQUIRED BY | | | 61G15-23.002FLORIDA ADMINISTRATIVE | | | CODE. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-05-26 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-05-26 |
Time |
15:45 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2006-05-26 |
Time |
14:53 |
Sent To |
P |
|
| Notes |
| 2006-05-26 00:00:00 | | | | NONCOMPLIANT | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} PANEL SCHEDULE AND LOAD CALCULATIONS | | | FOR "B" ARE INCOMPLETE. THERE IS A | | | KITCHEN, 220.16"A", A BATHROOM, | | | 210.11(C)(3)., MICROWAVE, STOVE OR | | | REFRIGERATOR LISTED. | | | | | | 2} THE KITCHEN DOES NOT APPEAR TO HAVE | | | THE REQUIRED NUMBER OF RECEPTACLES PER | | | 210.52(C). NOTE THE SCALE ON PLANS. DRAW | | | TO SCALE PER FBC ADMIN CODE, CHAPTER 1. | | | | | | 3} THE SMOKE DETECTOR IN THE KITCHEN | | | MUST BE 3" FRROM THE DOOR, 20" FROM THE | | | RANGE, OR BE HEAT SENSING TYPE. NFPA-72. | | | | | | 4} GFI'S ARE MISSING IN THE BATHROOM, | | | 210.8(A)(1), GARAGE 210.8(A)(2), AND | | | KITCHEN, 210.8(A)(6). | | | | | | THE PERSON TAKING RESPONSIBILITY FOR THE | | | DESIGN MUST PRINT AND SIGN THEIR NAME TO | | | SAME PER 106.3.4.2. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-03-08 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-03-08 |
Time |
07:31 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-03-08 |
Time |
07:04 |
Sent To |
Z |
|
| Notes |
| 2006-03-08 00:00:00 | | | | AN ELECTRICAL PERMIT IS REQUIRED FOR THE | | | SCOPE OF THIS PROJECT. THE ELECTRRCAL | | | CONTRACTOR SHALL SUBMIT THE FOLLOWING | | | WITH APPLICATION. | | | | | | 1} COMPLETE RISER DIAGRAM PER 215.5. | | | | | | 2} AN ELECTRICAL FLOOR PLAN. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2006-09-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-14 |
Time |
13:24 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-14 |
Time |
13:24 |
Sent To |
E |
|
| Notes |
| 2006-09-14 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2006-09-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-08 |
Time |
16:06 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-08 |
Time |
16:06 |
Sent To |
Z |
|
| Notes |
| 2006-09-08 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2006-08-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-01 |
Time |
18:59 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-01 |
Time |
18:59 |
Sent To |
E |
|
| Notes |
| 2006-08-01 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-07-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-07-27 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-07-27 |
Time |
14:16 |
Sent To |
Z |
|
| Notes |
| 2006-07-27 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-07-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-07-17 |
Time |
15:35 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-07-17 |
Time |
15:35 |
Sent To |
Z |
|
| Notes |
| 2006-07-17 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-05-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-26 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-26 |
Time |
10:52 |
Sent To |
E |
|
| Notes |
| 2006-05-26 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-05-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-16 |
Time |
15:07 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-16 |
Time |
15:07 |
Sent To |
Z |
|
| Notes |
| 2006-05-16 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-03-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-03-21 |
Time |
15:42 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-03-21 |
Time |
15:42 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2006-04-05 |
Time |
|
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-03-04 |
Time |
14:02 |
Sent To |
|
|
| Notes |
| 2006-03-04 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2006-06-05 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-06-05 |
Time |
11:27 |
Rev Time |
0.15 |
| Received By |
tgordon |
Date |
2006-06-05 |
Time |
11:27 |
Sent To |
B |
|
| Notes |
| 2006-06-05 00:00:00 | NO MECHANICAL PLANS SUBMITTED, AND NO | | | MECHANICAL PERMIT NUMBER APPLIED FOR AT | | | THIS TIME. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-03-21 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-03-08 |
Time |
07:32 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2006-03-21 |
Time |
16:18 |
Sent To |
P |
|
| Notes |
| 2006-03-21 00:00:00 | *** DENIED *** | | | 1) PLEASE SUBMIT PLANS SHOWING EXISTING | | | FLOOR PLAN LAY-OUT OF ROOMS AND PROPOSED | | | FLOOR PLAN. | | | | | | 2) PLEASE PROVIDE VENTING FOR CLOTHS | | | DRYER IF NOT EXISTING. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2006-09-15 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-09-15 |
Time |
15:04 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2006-09-15 |
Time |
15:00 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2006-08-03 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-08-03 |
Time |
13:40 |
Rev Time |
1.25 |
| Received By |
mperson |
Date |
2006-08-03 |
Time |
13:39 |
Sent To |
B |
|
| Notes |
| 2006-08-03 00:00:00 | ******DENIED 3RD TIME****** | | | REFERENCE: FBC-2004 PLUMBING | | | | | | THE FOLLOWING INFORMATION IS STILL | | | REQUIRED FOR PLUMBING PLAN REVIEW: | | | | | | 1. PER FBC-2004, PLUMBING, SECTION 909.1 | | | WET VENT PERMITTED: ONLY THE FIXTURES | | | WITHIN THE BATHROOM GROUPS SHALL CONNECT | | | TO THE WET-VENTED HORIZONTAL BRANCH | | | DRAIN. ANY ADDITIONAL FIXTURES SHALL | | | DISCHARGE DOWNSTREAM OF THE WET VENT. | | | PLEASE SEE CORECTED DRAWING OF KITCHEN | | | SINK. | | | 2. PER FBC-2004,PLUMBING, SECTION 905.3 | | | VENT CONNECTIONS TO DRAINAGE SYSTEM. | | | EVERY DRY VENT CONNECTING TO A | | | HORIZONTAL DRAIN SHALL CONNECT ABOVE THE | | | CENTERLINE OF THE HORIZONTAL DRAIN PIPE. | | | PLEASE SEE CORRECTED DRAWING OF 3" | | | HORIZONTAL VENT BRANCH DOWNSTREAM OF THE | | | W.C. | | | 3. PER FBC-2004 PLUMBING, SECTION | | | 901.2.1 VENTING REQUIRED: EVERY TRAP AND | | | TRAPPED FIXTURE SHALL BE VENTED IN | | | ACCORDANCE WITH ONE OF THE VENTING | | | METHODS SPECIFIED IN THIS CHAPTER. | | | PLEASE SEE WHERE THE HORIZONTAL BRANCH | | | TO THE BATH LAV. MOVED ABOVE THE TUB. | | | 4. PER FBC-2004 PLUMBING, SECTION 708.7, | | | EXCEPTION 1, CLEANOUT NOT REQUIRED ON | | | KITCHEN SINK DUE TO THE FACT TRAP IS NOT | | | MORE THAN ONE PIPE SIZE SMALLLER THAN | | | THE DRAIN SERVED. PLEASE SEE CORRECTED | | | DRAWING WHERE CLEANOUT INDICATED ON | | | KITCHEN SINK P-TRAP. | | | | | | **IN ORDER TO EXPIDITE PLAN REVIEW: WHEN | | | RESUBMITTING, PLEASE REPLACE ONLY SHEETS | | | WHICH HAVE CHANGED AND PROVIDE ONE COPY | | | OF ALL OLD/VOIDED SHEETS FOR REFERENCE | | | ONLY. (NOTE: PLEASE SEE CORRECTED | | | DRAWING IN RED INK FOR REFERENCE FOR | | | RESUBMITTAL, ONLY ONE CORRECTED DRAWING | | | IN RED INK) | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2006-06-05 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-06-05 |
Time |
09:24 |
Rev Time |
1.00 |
| Received By |
mperson |
Date |
2006-06-05 |
Time |
09:24 |
Sent To |
M |
|
| Notes |
| 2006-06-05 00:00:00 | ******DENIED 2ND TIME****** | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | | | | THE FOLLOWING INFORMATION IS STILL | | | REQUIRED FROM PLUMBING PLAN REVIEW: | | | | | | 1. PER CHAPTER 1, SECTION 106: | | | MORE INFORMATION REQUIRED. PLEASE | | | INDICATE ON DRAWING EXISTING PLUMBING | | | LAYOUT, AND ON A SEPERATE DRAWING | | | INDICATE ON THE DRAWING THE NEW PROPOSED | | | PLUMBING LAYOUT. IF NEW PROPOSED | | | PLUMBING LAYOUT IS DIFFERENT FROM | | | EXISTING PLEASE FOLLOW WHAT IS REQUIRED | | | IN #2. IF PLUMBING LAYOUT IS THE SAME | | | WITH NO CHANGES, PLEASE INDICATE THIS ON | | | THE DRAWING. IF PLUMBING LAYOUT IS THE | | | SAME AND THE PLUMBING FIXTURES ARE TO BE | | | CHANGED, PLEASE INDCATE ON DRAWING | | | FIXTURE CHANGE OUT ONLY. | | | 2. 106.3.5.4 RESIDENTIAL (ONE AND TWO | | | FAMILY) SUBMIT A PLUMBING SANITARY | | | ISOMETRIC RISER DIAGRAM INDICATING ALL | | | WASTE, VENTS, TRAPS WITH SIZES, AND | | | CLEANOUT LOCATIONS.(NOTE: PLEASE SEE | | | CORRECTED DRAWING IN RED INK FOR | | | REFERENCE FOR RESUBMITTAL) | | | 3. THE FOLLOWING IS REQUIRED FOR CLEAN- | | | OUT LOCATIONS PLEASE SEE CORRECTED | | | DRAWING IN RED INK FOR REFERENCE FOR | | | RESUBMITTAL. | | | (A) 708.3.4 BASE OF STACK. A CLEANOUT | | | SHALL BE PROVIDED AT THE BASE OF EACH | | | WASTE OR SOIL STACK(NOTE: SEE CORRECTED | | | DRAWING IN RED INK FOR REFERENCE FOR | | | RESUBMITTAL) | | | (B) 708.3.5 BUILDING DRAIN AND BUILDING | | | SEWER JUNCTION. THERE SHALL BE A | | | CLEANOUT NEAR THE JUNCTION OF THE | | | BUILDING DRAIN AND THE BUILDING SEWER. | | | (NOTE: SEE CORRECTED DRAWING IN RED INK | | | FOR REFERENCE FOR RESUBMITTAL) | | | (C) 708.9 ACCESS. ACCESS SHALL BE | | | PROVIDED TO ALL CLEANOUTS.(NOTE: SEE | | | LOCATION OF WASHING MACHINE CLEANOUT | | | LOCATION IN RED INK OF CORRECTED DRAWING | | | FOR REFERENCE FOR RESUBMITTAL) | | | 4. CHANGE S.V. ON KITCHEN SINK TO | | | AUTOMATIC AIR VENT (A.A.V.) SEE | | | CORRECTED DRAWING IN RED INK FOR | | | REFERENCE FOR RESUBMITTAL. | | | 5. THERE IS ONLY ONE CORRECTED DRAWING | | | IN RED INK OF THE PLUMBING ISOMETRIC | | | RISER DIAGARAM. TWO RESUBMITTED DRAWINGS | | | OF THE ISOMETRIC PLUMBING RISER DIAGRAM | | | INDICATING THE ABOVE CORRECTIONS AND | | | THOSE CORRECTIONS INDICATED ON THE | | | CORRECTED RISER DIAGRAM ARE REQUIRED FOR | | | RESUBMITTAL. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-03-22 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-03-22 |
Time |
09:50 |
Rev Time |
1.00 |
| Received By |
mperson |
Date |
2006-03-22 |
Time |
09:49 |
Sent To |
B |
|
| Notes |
| 2006-03-22 00:00:00 | ****DENIED**** | | | REFERENCE: FBC-2004 PLUMBING AND CITY OF | | | WEST PALM BEACH, AMENDMENTS TO FBC, | | | CHAPTER 1: | | | | | | PLEASE REFLECT THE FOLLOWING INFORMATION | | | REQUIRED FOR PLAN REVIEW: | | | | | | 1. A PLUMBING PERMIT IS REQUIRED FOR THE | | | SCOPE OF THIS PROJECT. THE PLUMBING | | | CONTRACTER SHALL SUBMIT THE FOLLOWING | | | INFORMATION WITH APPLICATION. | | | 2. PER CHAPTER 1, SEC. 106, PLEASE | | | SUBMIT DRAWING SHOWING EXISTING FLOOR | | | PLAN LAY-OUT OF ROOMS AND A DRAWING IN- | | | DICATING PROPOSED FLOOR PLAN. | | | 3. PER CHAPTER 1, SEC. 106.3.5.4 RESI- | | | DENTIAL (ONE-AND TWO-FAMILY) ANY NEW OR | | | CHANGES TO EXISTING PLUMBING A SANITARY | | | ISOMETRIC RISER DIAGRAM REQUIRED. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561)805-6730 | | | FAX (561)805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561)805-6721 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
P |
Date |
2006-09-11 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-09-11 |
Time |
13:46 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-09-11 |
Time |
13:46 |
Sent To |
I |
|
| Notes |
| 2006-09-11 00:00:00 | NOTE: THE NONCONFORMING STRUCTURE SHALL | | | NOT BE IMPROVED, CONSTRUCTRED, ENLARGED | | | OR ALTERED IN ANY MANNER TO CREATE A NEW | | | NONCONFORMITY OR TO INCREASE AN EXISTING | | | NONCONFORMITY.STRUCTURE MUST STAY AS A | | | APT WITH GARAGE. MUST HAVE INTERIOR | | | ACCESS FROM THE APT TO THE GARAGE. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
F |
Date |
2006-07-31 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-07-31 |
Time |
14:41 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-07-31 |
Time |
14:41 |
Sent To |
I |
|
| Notes |
| 2006-07-31 00:00:00 | DENIED, | | | 1. THE PROPOSED SCOPE OF WORK MUST BE | | | CORRECTED ON THE PERMIT APPLICATION AND | | | COMPUTER SYSTEM. PLEASE HAVE STAFF TO | | | CORRECT IN THE SYSTEM AND MAKE CHANGES. | | | 2. THE PLANS MUST ALL MATCH TO THE SCOPE | | | OF WORK.THE EXISTING PLANS THAT DOES | | | NOT PROVIDE/SHOW THE INTERIOR ACCESS | | | FROM THE APT TO GARAGE (ELECTRICAL PLANS | | | AND EXISTING FLOOR PLANS). PLEASE | | | PROVIDE TWO SETS AND REMOVE THE OLD | | | PLANS AND INDICATE ON PLANS OLD COPIES. | | | 3. THE NONCONFORMING STRUCTURE SHALL NOT | | | BE IMPROVED, CONSTRUCTRED, ENLARGED OR | | | ALTERED IN ANY MANNER TO CREATE A NEW | | | NONCONFORMITY OR TO INCREASE AN EXISTING | | | NONCONFORMITY.STRUCTURE MUST STAY AS A | | | APT WITH GARAGE. | | | | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2006-07-19 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-07-19 |
Time |
11:12 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-07-18 |
Time |
18:35 |
Sent To |
|
|
| Notes |
| 2006-07-19 00:00:00 | DENIED, SEC 94-513 (2) ZONED SF7 | | | 1. NONCONFORMING STRUCTURE SHALL NOT BE | | | IMPROVED, CONSTRCUTRED, ENLARGED OR | | | ALTERED IN ANY MANNER TO CREATE A NEW | | | NONCONFORMITY OR TO INCREASE AN EXISTING | | | NONCONFORMITY. | | | 2. THE STRUCTURE MUST STAY AS IS (APT | | | WITH GARAGE), CANNOT INCREASE THE LIVING | | | SPACE TO INCREASE THE NONCONFORMITY. | | | 3. IF THE PROPOSED WORK IS JUST INTERIOR | | | (GARAGE DOOR CANNOT BE ENCLOSED) AND | | | WOULD NEED TO PROVIDE A EXISTING FLOOR | | | PLAN, DEMO OF THE EXISTING FLOOR PLAN | | | AND A PROPOSED, PLUMBING PLANS WOULD BE | | | NEEDED IF PLUMBING IS BEING REPLACE, | | | RELOCATED ETC. | | | | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 | | | | | | GREEN CARD PULLED SHOWS A RES & GARAGE | | | APT. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2006-05-25 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-05-25 |
Time |
13:09 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-05-25 |
Time |
13:09 |
Sent To |
|
|
| Notes |
| 2006-05-25 00:00:00 | DENIED, 2ND REQUEST. | | | 1. PLEASE PROVIDE TWO COPY OF SURVEY | | | SHOWING THE LOCATION OF THE PROPOSED | | | WORK (HIGHLIGHT THE AREA OF GARAGE DOOR | | | BEING REPLACED). | | | 2. NEED TO SEE THE ADDRESSING STAFF | | | (LILLY AT 822-1239) REGARDING THE | | | ADDRESS 505 45TH STREET. PROPERTY | | | ADDRESS IS 501 45TH STREET. | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2006-03-17 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-03-17 |
Time |
14:28 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-03-17 |
Time |
14:28 |
Sent To |
I |
|
| Notes |
| 2006-03-17 00:00:00 | DENIED, | | | 1. PLEASE PROVIDE TWO COPY OF SURVEY | | | SHOWING THE LOCATION OF THE PROPOSED | | | WORK (HIGHLIGHT THE AREA OF GARAGE DOOR | | | BEING REPLACED). | | | 2. MUST PROVIDE A TWO FULL COPY OF FLOOR | | | PLANS IDENTIFYING ALL AREA OF THE HOUSE. | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|