Plan Review Details - Permit 06030074
Plan Review Stops For Permit 06030074
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2006-09-27 Cont ID  
Sent By mperson Date 2006-09-15 Time 15:02 Rev Time 0.00
Received By amorse Date 2006-09-15 Time 14:05 Sent To  
Notes
2006-09-27 00:00:00 
  
 ACCIDENTALY ENTERED ADDRESSING REVIEW
 ADRIAN

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2006-09-27 Cont ID  
Sent By amorse Date 2006-09-27 Time 14:10 Rev Time 0.00
Received By amorse Date 2006-09-27 Time 14:10 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2006-08-05 Cont ID  
Sent By mperson Date 2006-08-05 Time 15:04 Rev Time 0.00
Received By amorse Date 2006-08-05 Time 11:59 Sent To PC
Notes
2006-08-05 00:00:00 
  
 DENIED
  
 1) AN ENGINEER PRACTICING THROUGH A DULY
 AUTHORIZED ENGINEERING BUSINESS SHALL
 INDICATE THEIR NAME AND LICENCE #, AS
 WELL AS THE NAME,ADDRESS AND CERTIFICATE
 OF AUTHORIZATION #ON EACH SHEET PER
 61G15-23.002(2) FAC
  
 2) PER 713.13(2) F.S. IF THE IMPROVEMENT
 DESCRIBED IN THE NOC HAS NOT COMMENCED
 WITHIN 90 DAYS OF RECORDING THE NOTICE
 IS VOID
  
 3) NO WHITE OUT PERMITTED ON DRAWINGS
 PLEASE CORRECT
  
 4) SUB TRADES ON APPLICATION BUT NO
 LICENCE NUMBERS OR PERMIT NUMBERS
 GENERATED PLEASE CORRECT
  
 5) EXISTING GARAGE DOOR ON ELECTRICAL
 SHOWS GFI MOUNTED ON IT PLEASE CLARIFY
  
 6)THE PERMIT APPLICATION SHALL INCLUDE
 TWO COPIES OF EACH PRODUCT APPROVAL THAT
 IS RELEVANT PER 9B-72. THESE SHOULD
 INCLUDE THE FLORIDA STATE APPROVAL COVER
 PAGES, AND THE PRODUCT NOA THAT LISTS
 THE SYSTEM COMPONENTS/ FASTENER LIST
 PAGES, THE PAGES WITH THE CHOSEN
 ASSEMBLY/ SYSTEM TO BE USED AND THE
 GENERAL LIMITATIONS PAGE. ALL CAN BE
 FOUND ON WWW.FLORIDABUILDING.ORG
 (9B-72 INCLUDES ALL EXTERIOR COMPONENTS
 SUCH AS WINDOWS, DOORS, MULLIONS, ETC.)
 ***************************************
 1)PROVIDE FLORIDA COVER SHEETS FOR TRACO
 WINDOWS FL# 6585 AND NEW UPDATED NOA#
 05-0729.03
 2) THURMA-TRU COVER IS CORRECT BUT NO
 DRAWINGS WERE SUBMITTED PLEASE SEE PAGE
 2 OF THE COVER SHEET TO PRINT OUT THE
 APPLICABLE DRAWING
 3) PROVIDE COVER SHEETS FOR ARMOR
 SCREEN, FL# 320
  
 7) SUBMIT PROOF OF OWNERSHIP OR CHANGE
 OWNER INFORMATION ON APPLICATION
 *****PROPERTY APPRAISER HAS RUTH AND
 FREEMAN L REAMES AS OWNER APPLICATION
 HAS DANIEL PLEASE CORRECT***
  
 8) PROPERTY HAS HISTORIC DESIGNATION AND
 REQUIRES HISTORIC APPROVAL AND STAMP
  
 ADRIAN MORSE
 BLDG PLAN REVIEW
 561-805-6716
  
  
  
  
  
  
  
  
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-06-08 Cont ID  
Sent By amorse Date 2006-06-08 Time 09:02 Rev Time 0.50
Received By amorse Date 2006-06-08 Time 09:02 Sent To PC
Notes
2006-06-08 00:00:00 
  
 DENIED
  
 REQUESTED INFORMATION NOT SUBMITTED FROM
 FIRST REVIEW
  
  
 1) PROVIDE PREVIOUS LAYOUT OR DEMOLITION
 PLAN
  
 2) PROVIDE COMPLETE DRAWINGS FOR REVIEW
 TO INCLUDE WORK BY ALL TRADES, ALSO
 STRUCTURAL WORK FOR CLOSE IN OF GARAGE
 DOOR
  
 3) THE PERMIT APPLICATION SHALL INCLUDE
 TWO COPIES OF EACH PRODUCT APPROVAL THAT
 IS RELEVANT PER 9B-72. THESE SHOULD
 INCLUDE THE FLORIDA STATE APPROVAL COVER
 PAGES, AND THE PRODUCT NOA THAT LISTS
 THE SYSTEM COMPONENTS/ FASTENER LIST
 PAGES, THE PAGES WITH THE CHOSEN
 ASSEMBLY/ SYSTEM TO BE USED AND THE
 GENERAL LIMITATIONS PAGE. ALL CAN BE
 FOUND ON WWW.FLORIDABUILDING.ORG
 (9B-72 INCLUDES ALL EXTERIOR COMPONENTS
 SUCH AS WINDOWS, DOORS, MULLIONS, ETC.)
  
 4) SUBMIT PROOF OF OWNERSHIP OR CHANGE
 OWNER INFORMATION ON APPLICATION
  
 5) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT IS REQUIRED PRIOR TO
 A PERMIT BEING ISSUED
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-04-05 Cont ID  
Sent By amorse Date 2006-04-05 Time 07:09 Rev Time 0.50
Received By amorse Date 2006-04-05 Time 07:09 Sent To PC
Notes
2006-04-05 00:00:00 
  
 DENIED
  
 1) PROVIDE PREVIOUS LAYOUT OR DEMOLITION
 PLAN
  
 2) PROVIDE COMPLETE DRAWINGS FOR REVIEW
 TO INCLUDE WORK BY ALL TRADES, ALSO
 STRUCTURAL WORK FOR CLOSE IN OF GARAGE
 DOOR
  
 3) THE PERMIT APPLICATION SHALL INCLUDE
 TWO COPIES OF EACH PRODUCT APPROVAL THAT
 IS RELEVANT PER 9B-72. THESE SHOULD
 INCLUDE THE FLORIDA STATE APPROVAL COVER
 PAGES, AND THE PRODUCT NOA THAT LISTS
 THE SYSTEM COMPONENTS/ FASTENER LIST
 PAGES, THE PAGES WITH THE CHOSEN
 ASSEMBLY/ SYSTEM TO BE USED AND THE
 GENERAL LIMITATIONS PAGE. ALL CAN BE
 FOUND ON WWW.FLORIDABUILDING.ORG
 (9B-72 INCLUDES ALL EXTERIOR COMPONENTS
 SUCH AS WINDOWS, DOORS, ETC.)
  
 4) SUBMIT PROOF OF OWNERSHIP OR CHANGE
 OWNER INFORMATION ON APPLICATION
  
 5) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT IS REQUIRED PRIOR TO
 A PERMIT BEING ISSUED
  
  
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716
  
  
  
  

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2006-09-15 Cont ID  
Sent By btrobaug Date 2006-09-15 Time 14:20 Rev Time 0.50
Received By btrobaug Date 2006-09-15 Time 14:09 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2006-08-02 Cont ID  
Sent By btrobaug Date 2006-08-02 Time 16:01 Rev Time 0.50
Received By btrobaug Date 2006-08-02 Time 14:33 Sent To P
Notes
2006-08-02 00:00:00 
 NONCOMPLIANT
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} THE GARAGE RECEPTACLES MUST COMPLY
 WITH 210.8(A)(2).
  
 2} THE ENGINEER OF RECORD SHALL INDICATE
 THE CERTIFICATE OF AUTHORIZATIONNUMBER
 ALONG WITH OTHER INFORMATION REQUIRED BY
 61G15-23.002FLORIDA ADMINISTRATIVE
 CODE.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2006-05-26 Cont ID  
Sent By btrobaug Date 2006-05-26 Time 15:45 Rev Time 0.75
Received By btrobaug Date 2006-05-26 Time 14:53 Sent To P
Notes
2006-05-26 00:00:00 
 NONCOMPLIANT
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} PANEL SCHEDULE AND LOAD CALCULATIONS
 FOR "B" ARE INCOMPLETE. THERE IS A
 KITCHEN, 220.16"A", A BATHROOM,
 210.11(C)(3)., MICROWAVE, STOVE OR
 REFRIGERATOR LISTED.
  
 2} THE KITCHEN DOES NOT APPEAR TO HAVE
 THE REQUIRED NUMBER OF RECEPTACLES PER
 210.52(C). NOTE THE SCALE ON PLANS. DRAW
 TO SCALE PER FBC ADMIN CODE, CHAPTER 1.
  
 3} THE SMOKE DETECTOR IN THE KITCHEN
 MUST BE 3" FRROM THE DOOR, 20" FROM THE
 RANGE, OR BE HEAT SENSING TYPE. NFPA-72.
  
 4} GFI'S ARE MISSING IN THE BATHROOM,
 210.8(A)(1), GARAGE 210.8(A)(2), AND
 KITCHEN, 210.8(A)(6).
  
 THE PERSON TAKING RESPONSIBILITY FOR THE
 DESIGN MUST PRINT AND SIGN THEIR NAME TO
 SAME PER 106.3.4.2.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-03-08 Cont ID  
Sent By btrobaug Date 2006-03-08 Time 07:31 Rev Time 0.50
Received By btrobaug Date 2006-03-08 Time 07:04 Sent To Z
Notes
2006-03-08 00:00:00 
 AN ELECTRICAL PERMIT IS REQUIRED FOR THE
 SCOPE OF THIS PROJECT. THE ELECTRRCAL
 CONTRACTOR SHALL SUBMIT THE FOLLOWING
 WITH APPLICATION.
  
 1} COMPLETE RISER DIAGRAM PER 215.5.
  
 2} AN ELECTRICAL FLOOR PLAN.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2006-09-14 Cont ID  
Sent By adarroug Date 2006-09-14 Time 13:24 Rev Time 0.00
Received By adarroug Date 2006-09-14 Time 13:24 Sent To E
Notes
2006-09-14 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2006-09-08 Cont ID  
Sent By adarroug Date 2006-09-08 Time 16:06 Rev Time 0.00
Received By adarroug Date 2006-09-08 Time 16:06 Sent To Z
Notes
2006-09-08 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2006-08-01 Cont ID  
Sent By adarroug Date 2006-08-01 Time 18:59 Rev Time 0.00
Received By adarroug Date 2006-08-01 Time 18:59 Sent To E
Notes
2006-08-01 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2006-07-27 Cont ID  
Sent By adarroug Date 2006-07-27 Time 14:16 Rev Time 0.00
Received By adarroug Date 2006-07-27 Time 14:16 Sent To Z
Notes
2006-07-27 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-07-17 Cont ID  
Sent By adarroug Date 2006-07-17 Time 15:35 Rev Time 0.00
Received By adarroug Date 2006-07-17 Time 15:35 Sent To Z
Notes
2006-07-17 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-05-26 Cont ID  
Sent By adarroug Date 2006-05-26 Time 10:52 Rev Time 0.00
Received By adarroug Date 2006-05-26 Time 10:52 Sent To E
Notes
2006-05-26 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-05-16 Cont ID  
Sent By adarroug Date 2006-05-16 Time 15:07 Rev Time 0.00
Received By adarroug Date 2006-05-16 Time 15:07 Sent To Z
Notes
2006-05-16 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-03-21 Cont ID  
Sent By dpalmer Date 2006-03-21 Time 15:42 Rev Time 0.00
Received By dpalmer Date 2006-03-21 Time 15:42 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2006-04-05 Time   Rev Time 0.00
Received By adarroug Date 2006-03-04 Time 14:02 Sent To  
Notes
2006-03-04 00:00:00TO "E" BOX

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2006-06-05 Cont ID  
Sent By tgordon Date 2006-06-05 Time 11:27 Rev Time 0.15
Received By tgordon Date 2006-06-05 Time 11:27 Sent To B
Notes
2006-06-05 00:00:00NO MECHANICAL PLANS SUBMITTED, AND NO
 MECHANICAL PERMIT NUMBER APPLIED FOR AT
 THIS TIME.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2006-03-21 Cont ID  
Sent By btrobaug Date 2006-03-08 Time 07:32 Rev Time 0.25
Received By tgordon Date 2006-03-21 Time 16:18 Sent To P
Notes
2006-03-21 00:00:00*** DENIED ***
 1) PLEASE SUBMIT PLANS SHOWING EXISTING
 FLOOR PLAN LAY-OUT OF ROOMS AND PROPOSED
 FLOOR PLAN.
  
 2) PLEASE PROVIDE VENTING FOR CLOTHS
 DRYER IF NOT EXISTING.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.
  

Review Stop P PLUMBING
Rev No 4 Status P Date 2006-09-15 Cont ID  
Sent By mperson Date 2006-09-15 Time 15:04 Rev Time 0.33
Received By mperson Date 2006-09-15 Time 15:00 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2006-08-03 Cont ID  
Sent By mperson Date 2006-08-03 Time 13:40 Rev Time 1.25
Received By mperson Date 2006-08-03 Time 13:39 Sent To B
Notes
2006-08-03 00:00:00******DENIED 3RD TIME******
 REFERENCE: FBC-2004 PLUMBING
  
 THE FOLLOWING INFORMATION IS STILL
 REQUIRED FOR PLUMBING PLAN REVIEW:
  
 1. PER FBC-2004, PLUMBING, SECTION 909.1
 WET VENT PERMITTED: ONLY THE FIXTURES
 WITHIN THE BATHROOM GROUPS SHALL CONNECT
 TO THE WET-VENTED HORIZONTAL BRANCH
 DRAIN. ANY ADDITIONAL FIXTURES SHALL
 DISCHARGE DOWNSTREAM OF THE WET VENT.
 PLEASE SEE CORECTED DRAWING OF KITCHEN
 SINK.
 2. PER FBC-2004,PLUMBING, SECTION 905.3
 VENT CONNECTIONS TO DRAINAGE SYSTEM.
 EVERY DRY VENT CONNECTING TO A
 HORIZONTAL DRAIN SHALL CONNECT ABOVE THE
 CENTERLINE OF THE HORIZONTAL DRAIN PIPE.
 PLEASE SEE CORRECTED DRAWING OF 3"
 HORIZONTAL VENT BRANCH DOWNSTREAM OF THE
 W.C.
 3. PER FBC-2004 PLUMBING, SECTION
 901.2.1 VENTING REQUIRED: EVERY TRAP AND
 TRAPPED FIXTURE SHALL BE VENTED IN
 ACCORDANCE WITH ONE OF THE VENTING
 METHODS SPECIFIED IN THIS CHAPTER.
 PLEASE SEE WHERE THE HORIZONTAL BRANCH
 TO THE BATH LAV. MOVED ABOVE THE TUB.
 4. PER FBC-2004 PLUMBING, SECTION 708.7,
 EXCEPTION 1, CLEANOUT NOT REQUIRED ON
 KITCHEN SINK DUE TO THE FACT TRAP IS NOT
 MORE THAN ONE PIPE SIZE SMALLLER THAN
 THE DRAIN SERVED. PLEASE SEE CORRECTED
 DRAWING WHERE CLEANOUT INDICATED ON
 KITCHEN SINK P-TRAP.
  
 **IN ORDER TO EXPIDITE PLAN REVIEW: WHEN
 RESUBMITTING, PLEASE REPLACE ONLY SHEETS
 WHICH HAVE CHANGED AND PROVIDE ONE COPY
 OF ALL OLD/VOIDED SHEETS FOR REFERENCE
 ONLY. (NOTE: PLEASE SEE CORRECTED
 DRAWING IN RED INK FOR REFERENCE FOR
 RESUBMITTAL, ONLY ONE CORRECTED DRAWING
 IN RED INK)
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721
  
  
  
  
  
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2006-06-05 Cont ID  
Sent By mperson Date 2006-06-05 Time 09:24 Rev Time 1.00
Received By mperson Date 2006-06-05 Time 09:24 Sent To M
Notes
2006-06-05 00:00:00******DENIED 2ND TIME******
 REFERENCE: FBC-2004 PLUMBING
 FBC-2004 CHAPTER 1
  
 THE FOLLOWING INFORMATION IS STILL
 REQUIRED FROM PLUMBING PLAN REVIEW:
  
 1. PER CHAPTER 1, SECTION 106:
 MORE INFORMATION REQUIRED. PLEASE
 INDICATE ON DRAWING EXISTING PLUMBING
 LAYOUT, AND ON A SEPERATE DRAWING
 INDICATE ON THE DRAWING THE NEW PROPOSED
 PLUMBING LAYOUT. IF NEW PROPOSED
 PLUMBING LAYOUT IS DIFFERENT FROM
 EXISTING PLEASE FOLLOW WHAT IS REQUIRED
 IN #2. IF PLUMBING LAYOUT IS THE SAME
 WITH NO CHANGES, PLEASE INDICATE THIS ON
 THE DRAWING. IF PLUMBING LAYOUT IS THE
 SAME AND THE PLUMBING FIXTURES ARE TO BE
 CHANGED, PLEASE INDCATE ON DRAWING
 FIXTURE CHANGE OUT ONLY.
 2. 106.3.5.4 RESIDENTIAL (ONE AND TWO
 FAMILY) SUBMIT A PLUMBING SANITARY
 ISOMETRIC RISER DIAGRAM INDICATING ALL
 WASTE, VENTS, TRAPS WITH SIZES, AND
 CLEANOUT LOCATIONS.(NOTE: PLEASE SEE
 CORRECTED DRAWING IN RED INK FOR
 REFERENCE FOR RESUBMITTAL)
 3. THE FOLLOWING IS REQUIRED FOR CLEAN-
 OUT LOCATIONS PLEASE SEE CORRECTED
 DRAWING IN RED INK FOR REFERENCE FOR
 RESUBMITTAL.
 (A) 708.3.4 BASE OF STACK. A CLEANOUT
 SHALL BE PROVIDED AT THE BASE OF EACH
 WASTE OR SOIL STACK(NOTE: SEE CORRECTED
 DRAWING IN RED INK FOR REFERENCE FOR
 RESUBMITTAL)
 (B) 708.3.5 BUILDING DRAIN AND BUILDING
 SEWER JUNCTION. THERE SHALL BE A
 CLEANOUT NEAR THE JUNCTION OF THE
 BUILDING DRAIN AND THE BUILDING SEWER.
 (NOTE: SEE CORRECTED DRAWING IN RED INK
 FOR REFERENCE FOR RESUBMITTAL)
 (C) 708.9 ACCESS. ACCESS SHALL BE
 PROVIDED TO ALL CLEANOUTS.(NOTE: SEE
 LOCATION OF WASHING MACHINE CLEANOUT
 LOCATION IN RED INK OF CORRECTED DRAWING
 FOR REFERENCE FOR RESUBMITTAL)
 4. CHANGE S.V. ON KITCHEN SINK TO
 AUTOMATIC AIR VENT (A.A.V.) SEE
 CORRECTED DRAWING IN RED INK FOR
 REFERENCE FOR RESUBMITTAL.
 5. THERE IS ONLY ONE CORRECTED DRAWING
 IN RED INK OF THE PLUMBING ISOMETRIC
 RISER DIAGARAM. TWO RESUBMITTED DRAWINGS
 OF THE ISOMETRIC PLUMBING RISER DIAGRAM
 INDICATING THE ABOVE CORRECTIONS AND
 THOSE CORRECTIONS INDICATED ON THE
 CORRECTED RISER DIAGRAM ARE REQUIRED FOR
 RESUBMITTAL.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721
  
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2006-03-22 Cont ID  
Sent By mperson Date 2006-03-22 Time 09:50 Rev Time 1.00
Received By mperson Date 2006-03-22 Time 09:49 Sent To B
Notes
2006-03-22 00:00:00****DENIED****
 REFERENCE: FBC-2004 PLUMBING AND CITY OF
 WEST PALM BEACH, AMENDMENTS TO FBC,
 CHAPTER 1:
  
 PLEASE REFLECT THE FOLLOWING INFORMATION
 REQUIRED FOR PLAN REVIEW:
  
 1. A PLUMBING PERMIT IS REQUIRED FOR THE
 SCOPE OF THIS PROJECT. THE PLUMBING
 CONTRACTER SHALL SUBMIT THE FOLLOWING
 INFORMATION WITH APPLICATION.
 2. PER CHAPTER 1, SEC. 106, PLEASE
 SUBMIT DRAWING SHOWING EXISTING FLOOR
 PLAN LAY-OUT OF ROOMS AND A DRAWING IN-
 DICATING PROPOSED FLOOR PLAN.
 3. PER CHAPTER 1, SEC. 106.3.5.4 RESI-
 DENTIAL (ONE-AND TWO-FAMILY) ANY NEW OR
 CHANGES TO EXISTING PLUMBING A SANITARY
 ISOMETRIC RISER DIAGRAM REQUIRED.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 (561)805-6730
 FAX (561)805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561)805-6721

Review Stop Z ZONING
Rev No 5 Status P Date 2006-09-11 Cont ID  
Sent By mmclean Date 2006-09-11 Time 13:46 Rev Time 0.00
Received By mmclean Date 2006-09-11 Time 13:46 Sent To I
Notes
2006-09-11 00:00:00NOTE: THE NONCONFORMING STRUCTURE SHALL
 NOT BE IMPROVED, CONSTRUCTRED, ENLARGED
 OR ALTERED IN ANY MANNER TO CREATE A NEW
 NONCONFORMITY OR TO INCREASE AN EXISTING
 NONCONFORMITY.STRUCTURE MUST STAY AS A
 APT WITH GARAGE. MUST HAVE INTERIOR
 ACCESS FROM THE APT TO THE GARAGE.

Review Stop Z ZONING
Rev No 4 Status F Date 2006-07-31 Cont ID  
Sent By mmclean Date 2006-07-31 Time 14:41 Rev Time 0.00
Received By mmclean Date 2006-07-31 Time 14:41 Sent To I
Notes
2006-07-31 00:00:00DENIED,
 1. THE PROPOSED SCOPE OF WORK MUST BE
 CORRECTED ON THE PERMIT APPLICATION AND
 COMPUTER SYSTEM. PLEASE HAVE STAFF TO
 CORRECT IN THE SYSTEM AND MAKE CHANGES.
 2. THE PLANS MUST ALL MATCH TO THE SCOPE
 OF WORK.THE EXISTING PLANS THAT DOES
 NOT PROVIDE/SHOW THE INTERIOR ACCESS
 FROM THE APT TO GARAGE (ELECTRICAL PLANS
 AND EXISTING FLOOR PLANS). PLEASE
 PROVIDE TWO SETS AND REMOVE THE OLD
 PLANS AND INDICATE ON PLANS OLD COPIES.
 3. THE NONCONFORMING STRUCTURE SHALL NOT
 BE IMPROVED, CONSTRUCTRED, ENLARGED OR
 ALTERED IN ANY MANNER TO CREATE A NEW
 NONCONFORMITY OR TO INCREASE AN EXISTING
 NONCONFORMITY.STRUCTURE MUST STAY AS A
 APT WITH GARAGE.
  
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720

Review Stop Z ZONING
Rev No 3 Status F Date 2006-07-19 Cont ID  
Sent By mmclean Date 2006-07-19 Time 11:12 Rev Time 0.00
Received By mmclean Date 2006-07-18 Time 18:35 Sent To  
Notes
2006-07-19 00:00:00DENIED, SEC 94-513 (2) ZONED SF7
 1. NONCONFORMING STRUCTURE SHALL NOT BE
 IMPROVED, CONSTRCUTRED, ENLARGED OR
 ALTERED IN ANY MANNER TO CREATE A NEW
 NONCONFORMITY OR TO INCREASE AN EXISTING
 NONCONFORMITY.
 2. THE STRUCTURE MUST STAY AS IS (APT
 WITH GARAGE), CANNOT INCREASE THE LIVING
 SPACE TO INCREASE THE NONCONFORMITY.
 3. IF THE PROPOSED WORK IS JUST INTERIOR
 (GARAGE DOOR CANNOT BE ENCLOSED) AND
 WOULD NEED TO PROVIDE A EXISTING FLOOR
 PLAN, DEMO OF THE EXISTING FLOOR PLAN
 AND A PROPOSED, PLUMBING PLANS WOULD BE
 NEEDED IF PLUMBING IS BEING REPLACE,
 RELOCATED ETC.
  
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720
  
 GREEN CARD PULLED SHOWS A RES & GARAGE
 APT.

Review Stop Z ZONING
Rev No 2 Status F Date 2006-05-25 Cont ID  
Sent By mmclean Date 2006-05-25 Time 13:09 Rev Time 0.00
Received By mmclean Date 2006-05-25 Time 13:09 Sent To  
Notes
2006-05-25 00:00:00DENIED, 2ND REQUEST.
 1. PLEASE PROVIDE TWO COPY OF SURVEY
 SHOWING THE LOCATION OF THE PROPOSED
 WORK (HIGHLIGHT THE AREA OF GARAGE DOOR
 BEING REPLACED).
 2. NEED TO SEE THE ADDRESSING STAFF
 (LILLY AT 822-1239) REGARDING THE
 ADDRESS 505 45TH STREET. PROPERTY
 ADDRESS IS 501 45TH STREET.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720

Review Stop Z ZONING
Rev No 1 Status F Date 2006-03-17 Cont ID  
Sent By mmclean Date 2006-03-17 Time 14:28 Rev Time 0.00
Received By mmclean Date 2006-03-17 Time 14:28 Sent To I
Notes
2006-03-17 00:00:00DENIED,
 1. PLEASE PROVIDE TWO COPY OF SURVEY
 SHOWING THE LOCATION OF THE PROPOSED
 WORK (HIGHLIGHT THE AREA OF GARAGE DOOR
 BEING REPLACED).
 2. MUST PROVIDE A TWO FULL COPY OF FLOOR
 PLANS IDENTIFYING ALL AREA OF THE HOUSE.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720