Plan Review Details - Permit 06030007
| Plan Review Stops For Permit 06030007 |
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2006-04-25 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-04-25 |
Time |
11:27 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2006-04-25 |
Time |
11:27 |
Sent To |
PC |
|
| Notes |
| 2006-04-25 00:00:00 | REVISION: CHANGED METER LOCATION. ALSO | | | CHANGED PIPING TO COMBINATION PE | | | UNDERGROUND AND GALVANIZED ABOVE GROUND. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2006-03-23 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-03-23 |
Time |
11:19 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2006-03-23 |
Time |
11:19 |
Sent To |
PC |
|
| Notes |
| 2006-03-23 00:00:00 | MASTER RES-GEN #05081388 |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2006-03-13 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-03-13 |
Time |
08:54 |
Rev Time |
1.00 |
| Received By |
mperson |
Date |
2006-03-13 |
Time |
08:54 |
Sent To |
PC |
|
| Notes |
| 2006-03-13 00:00:00 | DENIED | | | REFERENCE: FBC-2004 FUEL GAS | | | | | | THE FOLLOWING INFORMATION IS REQUIRED | | | FOR GAS PERMIT. | | | | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2004 | | | FUEL GAS. | | | 2. SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE BEING USED. | | | 3. TYPE OF GAS, (LP OR NATURAL) | | | 4. BTU LOAD OF EACH APPLIANCE AND THE | | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | | THE FBC-2004 FUEL GAS CODE SECS. 401.8 | | | THRU 402.6.1 AND TABLES 402.4(1) THRU | | | 402.4(33).(NOTE: THE BTU LOAD FOR THE | | | GENERATOR IS 1,020,000 NOT 600,000 | | | PLEASE CORRECT) | | | 5. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES A.3.1(4). | | | | | | END OF COMMENTS: | | | REVIEW BY MIKE PERSON | | | (561)805-6730 | | | FAX (561)805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-04-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-24 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-24 |
Time |
11:42 |
Sent To |
G |
|
| Notes |
| 2006-04-24 00:00:00 | TO "G" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-03-23 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-03-23 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2006-03-02 |
Time |
19:52 |
Sent To |
|
|
| Notes |
| 2006-03-02 00:00:00 | TO "G" BOX |
|
|
|