Plan Review Details - Permit 06021248
Plan Review Stops For Permit 06021248
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2006-03-01 Cont ID  
Sent By lursu Date 2006-03-01 Time 10:51 Rev Time 0.00
Received By lursu Date 2006-03-01 Time 10:50 Sent To  
Notes
2006-03-01 00:00:00NEW ADDRESS ISSUED FOR THE VACANT
 PARCEL: 2737 TECUMSEH DR.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2006-08-28 Cont ID  
Sent By jgomez Date 2006-08-28 Time 16:57 Rev Time 2.00
Received By jgomez Date 2006-08-28 Time 16:57 Sent To  
Notes
2006-08-28 00:00:00BUILDING REVIEW THIRD CHECKLIST:
 1- ENGINEERING FIRM MUST PROVIDE THE
 CERTIFICAATE OF AUTHORIZATION NUMBER IN
 THE SOIL TEST REPORT AS REQUIRED BY SEC.
 61G15-23.002 OF THE FLORIDA
 ADMINISTRATIVE CODE.
 ***REQUESTED ON PREVIOUS CHECKLIST AND
 NOT DONE.
  
 2- AS REQUIRED BY DCA RULE 9B-72,
 PROVIDE FLORIDA OR LOCAL PRODUCT
 APPROVAL FOR:
 A) POCKET SLIDING GLASS DOORS AS SHOWN
 ON PLANS. INFORMATION SUBMITTED DOESN'T
 HAVE ANY DRAWINGS.
  
 B) ENGINEER TO CLARIFY WHY APPROVING
 THESE SLIDING GLASS DOORS IF THERE ARE
 NOT DRAWINGS SHOWING SPECIFIC SLIDING
 GLASS DOORS AND THE DESIGN PRESSURES
 THEY WERE DESIGNED FOR).
  
 3- STORM SHUTTERS:
 A) STRUCTURE TO BE ATTACHED TO IS
 CONCRETE BLOCK NOT CONCRETE. REVISE
 ANCHOR SPACING AS REQUIRED. SEE
 INSTALLATION SCHEDULE SHOWN ON
 ENGINEERED DRAWINGS FOR ANCHOR SPACING
 ACCORDING TO THE DESIGN PRESSURES AND
 STRUCTURE TO BE ATTACHED TO (CONCRETE
 BLOCK). AND, REVISE INSTALLATION
 SCHEDULE AS REQUIRED.
 ***NOTE: THERE IS NOT SUCH THING AS
 SOLID CONRETE BLOCK. PROVIDE COMPLETE
 ENGINEERING ANALYSIS FOR SOLID CONCRETE
 BLOCK INSTALLATIONS. SEE SHUTTERS
 ENGINEERED DRAWINGS.
  
 4- CONTRACTOR TO UPDATE LICENSE RECORDS.
 ACCORDING TO THE STATE RECORDS, LICENSE
 # CGC059256 IS FOR WELLINGTON EQUESTRIAN
 DEVELOPMENT. PERMIT APPLICATION SAYS NEW
 ENGLAND BUILDERS. NEED TO CORRECT
 INFORMATION TO MATCH.
  
 5- ENERGY CALCULATIONS:
 A) SEE MECHANICAL PLAN REVIEWER
 COMMENTS AND REVISE AS REQUIRED.
  
 B) CALCULATIONS NEED TO BE DONE FOR
 WORST CASE SCENARIO OR MUST BE DONE FOR
 CORRECT HOUSING ORIENTATION.
 CALCULATIONS DON'T COMPLY WITH EITHER
 ONE. SEE SURVEY FOR CORRECT HOUSE
 ORIENTAION AND REVISE AS REQUIRED.
  
 C) REVISE OVERHANG LENGHT AND HEIGHT.
 SEE SEC. 13-601 FBC 2004 FOR CORRECT WAY
 OF CALCULATING OVERHANG LENGTH AND
 HEIGHT AND REVISE CALCULATIONS AS
 REQUIRED.
  
 D) PROVIDE COMPLETE ADDRESS AND OWNER
 INFORMATION.
  
 E) REVISE NAME OF CONTRACTOR. SEE ITEM
 #4 ABOVE.
  
 6- NEED TO REVISE NOTICE OF COMMENCEMENT
 WITH CORRECT CONTRACTOR'S NAME. SEE ITEM
 #4 ABOVE.
 ALSO, NOC IS EXPIRED AFTER 90 DAYS IF
 WORK IS NOT STARTED. SEC. 713.13(2)
 FLORIDA STATUTES.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2006-07-05 Cont ID  
Sent By jgomez Date 2006-07-03 Time 16:52 Rev Time 2.00
Received By jgomez Date 2006-07-03 Time 16:52 Sent To  
Notes
2006-07-03 00:00:001- PROVIDE COPY OF IMPACT FEES PAID
 RECEIPT. NOT PROVIDED WITH SUBMITTAL.
 PLEASE MAKE SURE REVISED DRAWINGS HAVE
 IMPACT FEES STAMP WHEN RE-SUBMITTING
 PLANS.
  
 2- DESIGNER OF RECORD TO SPECIFY ROOF
 TILE FASTENING AS REQUIRED BY SEC.
 106.1.1.2 CITY AMENDMENTS TO FBC 2004.
 PRODUCT APPROVAL IS TO VERIFY THAT
 PRODUCT MEETS THE DESIGN CRITERIA
 SPECIFIED BY THE DESIGNER. DESIGNER
 STILL NEEDS TO SPECIFY METHOD OF
 ATTACHMENT.
  
 3- SOIL TEST REPORT NEEDS:
 A) CERTIFICATE OF AUTHORIZATION IN THE
 LETTER HEAD OR TITLE BLOCK AS REQUIRED
 BY SEC. 61G15-23.002 OF FLORIDA
 ADMINISTRATIVE CODE.
 B) ORIGINAL SIGNATURE. NO COPY. SEC.
 61G15-23.002 F.A.C.
 C) REVISE CODE SPECIFIED. NEED TO REFER
 TO FBC 2004 NOT 2001.
  
 4- PROVIDE 2 COPIES OF PRODUCT APPROVALS
 FOR:
 A) POCKET SLIDING GLASS DOORS AS SHOWN
 ON PLANS. ONE SUBMITTED DOESN'T MATCH
 DOORS SHOWN ON PLANS.
 B) SINGLE HUNG WINDOWS. PROVIDE CURRENT
 NOA THAT MATCHES ONE SUBMITTED FOR
 FLORIDA PRODUCT APPROVAL. GO TO THE DCA
 WEBSITE WWW.FLORIDABUILDING.ORG TO
 DOWNLOAD CORRECT NOA.
 C) FRENCH DOORS. PROVIDE NOA THAT
 MATCHES ONE SUBMITTED FOR FLORIDA
 PRODUCT APPROVAL.SEE DCA WEBSITE ABOVE
 TO DOWNLOAD CORRECT NOA.
 D) FIXED WINDOWS. NEED MATCHING NOA
 ALSO. SEE COMMENTS ABOVE.
  
 5- PROVIDE APPROVED LISTING AND SPECS
 FOR EXTERIOR HOOD ABOVE BBQ GRILL. ONE
 SUBMITTED DOESN'T LIST THE HOOD FOR
 EXTERIOR INSTALLATION. HOOD MUST BE
 SPECIFICALLY DESIGNED FOR OUTDOOR USE.
  
 6- STORM SHUTTERS:
 A) PRODUCT APPROVAL DRAWINGS ARE NOT
 LEGIBLE. PROVIDE CLEAR & LEGIBLE DWGS.
 B) SPECIFY WHICH PANELS ARE TO BE USED.
 22 OR 24 GAUGE TO VERIFY COMPLIANCE WITH
 PANEL SPANS, ETC.
 C) MINIMUM PANEL SPAN TO BE 48". SEE
 PAGE 3 OF DRAWINGS AND REVISE OPENINGS 4
 AND 5 AS REQUIRED. THEY ARE 40" LONG.
 D) STRUCTURE TO BE ATTACHED IS CONCRETE
 BLOCK NOTCONCRETE. REVISE AS REQUIRED.
 E) REVISE ANCHOR SPACING FOR PANELS
 THAT ARE LARGER THAN 72". SEE ANCHOR
 SCHEDULE IN DRAWINGS.
  
 7- A) REVISE ROOF SHEATHING FASTENER
 SPACING. SEE TABLE 2304.9.1 FBC 2004 FOR
 FASTENER SPACING IN ROOF ZONE #3.
 B) REVISE DRAWING 1/8. ROOF SHEATHING
 INFORMATION TO MATCH.
  
  
 NOTE:
 WHEN RE-SUBMITTING PACKAGE, PLEASE PUT
 TOGETHER 2 COMPLETE SETS. DRAWINGS 1
 THRU 16.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-03-31 Cont ID  
Sent By jgomez Date 2006-03-31 Time 19:18 Rev Time 3.00
Received By jgomez Date 2006-03-31 Time 19:18 Sent To  
Notes
2006-03-31 00:00:00BUILDING REVIEW CHECKLIST:
 1- NEED RECORDED NOTICE OF COMMENCEMENT.
  
 2- PAY IMPACT FEES TO PALM BEACH COUNTY.
 BRING BACK STAMPED PLANS & PAID RECEIPT.
  
 3- PROVIDE SOIL TEST REPORT. 2 COPIES.
  
 4- SURVEY: A) REVISE FLOOD ZONE. FLOOD
 ZONE IS "B" NOT A8 AS PER FEMA LETTER OF
 MAP REVISION.
 B) SURVEY TO HAVE ORIGINAL SIGNATURE
 AS REQUIRED BY CHAPTER 472 FLORIDA
 STATUTE & FL. ADMINISTRATIVE CODE.
  
 5- PROVIDE 2 COPIES FLORIDA OR LOCAL
 PRODUCT APPROVAL (DADE COUNTY NOA ALONE
 IS NOT AUTOMATICALLY AN STATEWIDE
 FLORIDA PRODUCT APPROVAL) FOR:
 A) POCKET SLIDING GLASS DOORS.
 B) SINGLE HUNG WINDOWS. IMPACT OR
 NON-IMPACT. NO BOTH
 C) FRENCH DOORS. IMPACT OR NON-IMPACT.
 NOT BOTH.
 D) WINDOW MULLIONS.
 E) FIXED WINDOWS AS SHOWN ON PLANS.
 IMPACT OR NON-IMPACT. NOT BOTH.
 F) ENTRY DOORS.
 G) ROOF TILE.
 H) GARAGE DOOR THAT MEETS THE DESIGN
 PRESSURES CALCULATED BY THE ENGINEER.
 I) ALL SIMPSON STRUCTURAL CONNECTORS
 SPECIFIED ON PLANS.
  
 6- ENGINEER OF RECORD TO REVIEW AND
 APPROVE IN WRITTING ALL PRODUCT
 APPROVALS AS REQUIRED BY SEC. 106.3.3 OF
 CITY AMENDMENTS TO FBC 2004.
  
 7- PROVIDE APPROVED LISTING AND SPECS
 FOR EXTERIOR HOOD ABOVE BBQ GRILL.
  
 8- WINDOWS IN 2ND FLOOR LOFT ROOM DON'T
 MEET THE EGRESS REQUIREMENTS OF SECTION
 R310 2004 RESIDENTIAL CODE. PROVIDE AT
 LEAST ONE WINDOW THAT COMPLIES WITH THIS
 SECTION OR CONSPICUOUSLY WRITE DOWN ON
 ROOM THAT SUCH ROOM CAN'B BE USED FOR
 SLEEPING.
  
 9- SPECIFY FASTENING FOR ROOF TILE AS
 REQUIRED BY SEC. 106.1.1.2 OF CITY
 AMENDMENTS TO FBC 2004
  
 10- PROVIDE SMOKE DETECTOR ON EACH FLOOR
 AS REQUIRED BY SEC. R313.1 OF 2004
 RESIDENTIAL CODE.
  
 11- ENERGY CALCULATIONS:
 A) NEED TO USE FORM 2004, NOT 2001.
 B) CALCULATIONS DON'T MATCH ACTUAL
 ORIENTATION OF THE HOUSE. SEE SURVEY FOR
 HOUSE ORIENTATION.CALCULATIONS MUST
 MATCH HOUSE ORIENTATION OR DONE FOR
 WORST CASE SCENARIO. REVISE AS REQUIRED.
 C) OWNER/AGENT TO SIGN AND DATE FORM
 D) COMPLETE ALL INFORMATION ON TOP OF
 FORM.
  
 12- STORM SHUTTERS:
 A) PROVIDE 2004 FLORIDA PRODUCT
 APPROVAL, NOT 2001.
 B) PROVIDE KEY PLAN AND COMPLETE
 INSTALLATION SCHEDULE. SEE ATTACHED
 SAMPLE THAT CONTAINS ALL REQUIRED
 INFORMATION FOR PLAN REVIEW.
  
 13- A) PROVIDE FIREPLACE COMPLETE
 APPROVED LISTING AND SPECS. SEC. R1004
 2004 RESIDENTIAL CODE.
 B) HEARTH IS REQUIRED. SEE SEC.
 R1004.2 2004 RESIDENTIAL CODE. REVISE
 NOTE ON PLANS AS REQUIRED.
 C) FLOOR PLAN TO SHOW FIREPLACE
 DIMENSIONS.
  
 14- SPECIFY ATTIC ACCESS SIZE ABOVE
 GARAGE AND ABOVE MASTER BEDROOM CLOSET.
 SEC. R807 2004 RESIDENTIAL CODE.
  
 15- IF NOT USING IMPACT GLASS, THEN
 SPECIFY SAFETY GLASS IN KITCHEN AREA,
 STUDY AREA, MASTER BATH AND 2ND FLOOR
 BATH AS REQUIRED BY SEC. R308.4 2004
 RESIDENTIAL CODE. SEE PLANS.
  
 16- A) STAIR WINDERS TO HAVE 6" MIN.
 WIDTH AT NARROWER SIDE AS REQUIRED BY
 SEC. R311.5.3.2 2004 RESIDENTIAL CODE.
 REVISE PLANS AS REQUIRED.
 B) STAIR SECTION ON SHEET #11: SHOW
 FIREBLOCKING MATERIAL AND LOCATION AS
 REQ'D BY SEC. R602.8 2004 RES. CODE.
  
 17- ROOF SHEATHING NOTE ON DRAWING 1 AND
 ROOF SHEATHING SPECS ON DETAIL 1/8 DON'T
 MATCH. REVISE AS REQUIRED.
  
 18- DRAWING #6: A) CONNECTOR #1
 SPECIFIED FOR GIRDER TRUSS ABOVE KITCHEN
 ROOF IS A WOOD TO MASONRY CONNECTOR.
 NEED TO SPECIFY WOOD TO WOOD CONNECTOR
 BECAUSE GIRDER TRUSS IS RESTING ON WOOD
 BEARING WALL. REVISE AS REQUIRED.
 B) CONNECTOR #7 DOESN'T RESIST THE
 LATERAL LOADS. REVISE AS REQUIRED. SEC.
 106.1.2 CITY AMENDMENTS TO FBC 2004.
  
 19- DRAWING #13 AND #14: PROVIDE DESIGN
 PRESSURES FOR 16'-0" X 8'-0" GARAGE
 DOOR. CALCULATIONS SHOWN ARE FOR DOORS
 LESS THAN 12'-0" WIDE. REVISE AS REQ'D.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-03-24 Cont ID  
Sent By jgomez Date 2006-03-24 Time 17:19 Rev Time 0.00
Received By jgomez Date 2006-03-24 Time 17:19 Sent To  
Notes
2006-03-24 00:00:00BUILDING REVIEW CHECKLIST:
  
 1- ACCORDING TO THE PERMIT FEE RECORDS
 CONTRACTOR DIDN'T PAID THE PERMIT FEES
 REQUIRED BY SEC. 108 OF CITY AMENDMENTS
 TO FBC 2004 WHEN PERMIT APPLICATION WAS
 SUBMITTED. REVIEW PROCESS IS STOPPED
 UNTIL FEES ARE PAID.
 FEES WERE UPDATED TO $467.105. SECTION
 108.3 CITY AMENDMENTS TO FBC 2004.
 THEREFORE, TOTAL OWED FEES ARE $5280.12
 WHICH INCLUDES UPDATED VALUATION AND
 RADON FEES.
 BUILDING REVIEW WILL RESUME AFTER FEES
 ARE PAID TO COMPLETE THE FIRST TIME
 AROUND COMPLETE REVIEW (PER DISCUSSION
 WITH ROBERT BROWN, LICENSE & PERMIT
 SERVICES MANAGER/ABO).
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-06-05 Cont ID  
Sent By btrobaug Date 2006-06-05 Time 17:15 Rev Time 0.50
Received By btrobaug Date 2006-06-05 Time 15:26 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-03-07 Cont ID  
Sent By btrobaug Date 2006-03-07 Time 14:50 Rev Time 0.50
Received By btrobaug Date 2006-03-07 Time 12:37 Sent To Z
Notes
2006-03-07 00:00:00 
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} NO LOAD IS SHOWN FOR THE 100 AMP SUB
 PANEL. PLEASE SUBMIT PANEL SCHEDULES FOR
 ALL PANELS SO THAT BRANCH CIRCUIT
 COMPLIANCE MAY BE REVIEWED.
  
 2} PLEASE LABEL THE ROOMS ON THE
 ELECTRICAL PLANS.
  
 3} HER BATH REQUIRES A RECEPTACLE AT THE
 SINK TO COMPLY WITH 210.52(D).
  
 4} BEDROOM #3 NEEDS RECEPTACLES ADDED TO
 COMPLY WITH 210.52(A)(1)&(2).
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-08-12 Cont ID  
Sent By adarroug Date 2006-08-12 Time 16:10 Rev Time 0.00
Received By adarroug Date 2006-08-12 Time 16:10 Sent To M
Notes
2006-08-12 00:00:00TO "M" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-08-08 Cont ID  
Sent By adarroug Date 2006-08-08 Time 10:05 Rev Time 0.00
Received By adarroug Date 2006-08-08 Time 10:05 Sent To Z
Notes
2006-08-08 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-06-02 Cont ID  
Sent By adarroug Date 2006-06-02 Time 08:29 Rev Time 0.00
Received By adarroug Date 2006-06-02 Time 08:29 Sent To E
Notes
2006-06-02 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-05-26 Cont ID  
Sent By adarroug Date 2006-05-26 Time 11:33 Rev Time 0.00
Received By adarroug Date 2006-05-26 Time 11:33 Sent To Z
Notes
2006-05-26 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-03-24 Cont ID  
Sent By jgomez Date 2006-03-24 Time 17:34 Rev Time 0.00
Received By jgomez Date 2006-02-28 Time 08:42 Sent To  
Notes
2006-02-28 00:00:00TO SFR RACK.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2006-08-14 Cont ID  
Sent By tgordon Date 2006-08-14 Time 16:19 Rev Time 1.00
Received By tgordon Date 2006-08-14 Time 16:19 Sent To P
Notes
2006-08-14 00:00:00*** DENIED ***
 1) SEE ENERGY CALCULATIONS HEATER 13A
 EQUALS 2.45 KW, HEATER B&C EQUALS 7.3
 KW, MECHANICAL PLANS ARE SHOWING 10 KW
 AND TWO 5 KW, PLEASE CORRECT ENERGY
 CAL'S..
  
 2) ENERGY CALCULATIONS NEED A WET
 SINGATUER ON THEM NOT A PHOTO COPY.
  
 3) SEE MANUAL J CALCULATIONS SYSTEM ONE,
 CHECK SQUARE FOOTAGE, IF NOT CORREST FOR
 THE ZONE THEN PLEASE CORRECT.
  
 4)SEE MANUAL J CALCULATIONS 2 SYSTEMS,
 THESE CALCULATIONS CAN NOT BE FOR THE
 TWO ZONES AS THE SQUARE FOOTAGE AND
 DESIGN ARE NOT THE SAME FOR THESE ZONES.
  
 5) SEE MANUAL J CAL'S. 2 SYSTEMS AREA
 AND VOLUME 15,000 DIVIDEND BY 881 EQUALS
 A CEILING HIGHT OF 17 FEET, PLEASE
 CORRECT.
  
 6) SEE MANUAL J CAL'S AREA 2388 + 881=
 3269 SQ. FEET. BUILDING PLANS SHOW FIRST
 FLOOR AT 3234.5 SQ. FEET, PLEASE
 RECALCULATE MANUAL J'S.
  
 7) ALL CHANGES TO PLANS NEED TO BE
 SIGNED AND DATED AT EACH CHANGE OR
 RECOPIED.
  
 8) IS THE LOFT ON THE SECOND FLOOR GOING
 TO HAVE A/C, IF SO PLEASE ADD TO PLANS.
  
 9) CONSTRUCTION DOCUMENTS SHALL BE OF
 SUFFICIENT CLARITY. PER 2004 FBC 106.1.1
 .
  
 10) ALL INFORMATION, DRAWINGS,
 SPECIFICATIONS AND ACCOMPANYING DATA
 SHALL BEAR THE NAME AND SIGNATURE OF THE
 PERSON RESPONSIBLE FOR THE DESIGN. PER
 FBC 104.2.1 .
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2006-06-14 Cont ID  
Sent By tgordon Date 2006-06-14 Time 16:06 Rev Time 0.45
Received By tgordon Date 2006-06-14 Time 16:06 Sent To B
Notes
2006-06-14 00:00:00*** DENIED ***
 1) PLEASE SUBMIT MANUAL J CAL'S. FOR
 SECOND FLOOR ALSO.
  
 2) MANUAL J CAL'S. FOR SYSTEM 2 IS
 CALCULATED AT 4 1/2 FOOT HIGH CEILINGS,
 PLEASE CORRECT.
  
 3) ENERGY CALCULATIONS ARE CALLING FOR A
 18 KW HEATER IN ONE UNIT, AND ELECTRICAL
 PLANS ARE SHOWING THE HEATER AT 10 KW,
 PLEASE CORRECT.
  
 4) PLEASE SHOW ON MECHANICAL PLANS THE
 A/C EQUIPMENT LISTING WITH ALL PERTINENT
 INFORMATION.
  
 5) SHOW THE SIZE OF THE SUPPLY AIR DUCT
 FROM MIXING BOX TO MIXING BOX ON THE
 FIRST FLOOR.
  
 6) PLEASE SHOW ALL GRILL SIZES ON THE
 MECHANICAL PLANS.
  
 7) PLEASE SHOW ALL BATHROOM EXHAUST FANS
 ON THE MECHANICAL PLANS.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2006-03-09 Cont ID  
Sent By tgordon Date 2006-03-09 Time 09:51 Rev Time 0.30
Received By tgordon Date 2006-03-09 Time 09:51 Sent To Z
Notes
2006-03-09 00:00:00 
 *** DENIED ***
 1) MECHANICAL PLANS HAVE TO MUCH FLOOR
 PLAN INFOMATION ON THEM AND RAE
 DIFFICULT TO READ. CONSTRUCTION
 DOCUMENTS SHALL BE OF SUFFICIENT
 CLARITY. PER 2004 FBC 106.1.1 .
  
 2) ENERGY CALCULATIONS NEED TO BE ON
 FORM 600A-04 (2004) PER FBC 13-600.3.A .
 AND NEED TO BE SIGNED BY OWNER/AGENT.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop P PLUMBING
Rev No 3 Status F Date 2006-08-23 Cont ID  
Sent By jleech Date 2006-08-23 Time 08:12 Rev Time 0.00
Received By jleech Date 2006-08-23 Time 08:12 Sent To B
Notes
2006-08-23 00:00:00DENIED;
 NO CHANGES TO THE SANITARY RISER DIAGRAM
 SINCE LAST REVIEW.
 1.FLOOR PLAN DOES NOT MATCH SANITARY
 RISER DIAGRAM. THERE IS NO BATHROOM #2
 ON FLOOR PLAN, BUT THERE IS ON RISER
 DIAGRAM.
 2.HORIZONTAL DRY VENTS ARE NOT PERMITED
 IN THE DRAINAGE SYSTEM, MASTER BATH
 HERS, SEC 905.3.
 3.BIDET IN HIS BATH IS NOT VENTED.
 4.THE BRANCH DRAIN FOR THE AUTOMATIC
 CLOTHES WASHER IS REQUIRED TO BE 3"
 SEC.403.6.
 5.CABANA BATH; SINK SHOWN ON RISER
 DIAGRAM NOT SHOWN ON FLOOR PLAN.
 SEE ONE SET OF PLANS MARKED IN RED.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop P PLUMBING
Rev No 2 Status F Date 2006-06-10 Cont ID  
Sent By jleech Date 2006-06-10 Time 10:02 Rev Time 0.00
Received By jleech Date 2006-06-10 Time 10:02 Sent To M
Notes
2006-06-10 00:00:00DENIED;
 FLOOR PLAN AND SANITARY RISER DIAGRAM DO
 NOT MATCH;
 1.BATH # (CABANA BATH) ONLY HAS ONE
 LAVATORY.
 2.BATH #2 DOES NOT EXIST ON FLOOR PLAN.
  
 RISER DIAGRAM CODE VIOLATIONS;
 1.AUTOMATIC CLOTHES WASHER FIXTURE DRAIN
 TO BE 3" PER. FBC-2004 PLUMBING SEC.
 406.3.
 2.BIDET AND SHOWER IN HIS MASTER BATH
 ARE NOT VENTED. (VENT REQUIRED TO BE UP
 STREAM OF W/C)
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop P PLUMBING
Rev No 1 Status F Date 2006-03-08 Cont ID  
Sent By jleech Date 2006-03-08 Time 13:07 Rev Time 0.00
Received By jleech Date 2006-03-08 Time 13:07 Sent To  
Notes
2006-03-08 00:00:00DENIED;
 SANITARY RISER DIAGRAM REQUIRED. SEE
 FBC-2004 CHAPTER 1 SEC.106.3.5.4(9).
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop Z ZONING
Rev No 3 Status P Date 2006-08-12 Cont ID  
Sent By mmclean Date 2006-08-12 Time 08:20 Rev Time 0.00
Received By mmclean Date 2006-08-12 Time 08:20 Sent To I
Notes
2006-08-12 00:00:00PROVISO: THE PROPOSED A/C IN THE REAR OF
 THE PROPERTY SHALL NOT BE CLOSER THAN
 6FT REAR PROPERTY LINE.

Review Stop Z ZONING
Rev No 2 Status F Date 2006-06-01 Cont ID  
Sent By mmclean Date 2006-06-01 Time 16:26 Rev Time 0.00
Received By mmclean Date 2006-06-01 Time 16:26 Sent To I
Notes
2006-06-01 00:00:00DENIED.
 1. MUST SHOW THE LOCATION OF THE A/C
 EQUIPMENT ON THE TWO COPY OF SURVEY WITH
 SETBACKS.
 2. THE A/C UNIT IS LOCATED WITHIN THE
 FRONT PROPERTY (SENECA CIRCLE) WHICH IS
 THE SHORTEST PORTION OF THE LOT.
 3. A/C UNIT CANNOT BE LOCATED WITHIN THE
 FRONT SETBACK.
 4. PLEASE INDICATE ON THE SURVEY THE
 DISTANCE OF THE UNIT FROM THE STRUCTURE
 & PROPERTY LINE.
  
 SEC 94-305 (4)
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720

Review Stop Z ZONING
Rev No 1 Status P Date 2006-03-22 Cont ID  
Sent By mmclean Date 2006-03-22 Time 13:55 Rev Time 0.00
Received By mmclean Date 2006-03-22 Time 13:55 Sent To B
Notes
***NONE***